Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Audiol Neurootol ; : 1-7, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38402865

RESUMO

INTRODUCTION: Several studies have reported that the number of patients with Bell's palsy varied significantly by month and season. However, few studies have reported the monthly variation in Bell's palsy based on the whole population. We investigated the monthly variation in Bell's palsy in Korea during a long-term period based on whole population data. METHODS: This retrospective study used the data of the National Health Insurance Service of Korea, which included the entire Korean population from 2008 to 2020. The monthly incidence of Bell's palsy per 100,000 was evaluated in total and according to sex, age, and residence. RESULTS: The total average monthly incidence differed significantly by month, with the highest observed in January (9.1 per 100,000) and the lowest in June (7.7 per 100,000) (p < 0.001). The average monthly incidence according to sex, age, and residence also varied significantly by month, with most of the highest values noted in January and the lowest in June. CONCLUSION: There was significant monthly variation in the incidence of Bell's palsy, with the highest in January during the winter and the lowest in June during the summer, based on whole population data over a long-term period in Korea.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38700539

RESUMO

PURPOSE: Facial nerve schwannomas (FNSs) are rare intracranial tumors, and the optimal management of these tumors remains unclear. We investigated the long-term follow-up results of FNS with good facial nerve function. METHODS: At nine medical centers in the Korean Facial Nerve Study Group, 43 patients undergoing observation periods longer than 12 months for FNS with good facial nerve function (House-Brackmann grade ≤ II) were enrolled, and clinical and radiographic data were obtained for these cases. RESULTS: The mean follow-up period was 63 months. In the majority of cases, tumors involved multiple segments (81.4%) and only eight cases were confined to a single site. There were no cases where the tumor was confined to the extratemporal region. Tumor size increased slightly, with an average estimated change of 0.48 mm/year. Twenty (46.5%) of 43 patients showed no change in tumor size. Seven patients (16.3%) showed worsening House-Brackmann (H-B) grade, of which two patients deteriorated from H-B grade I to II, four worsened to grade III, and one deteriorated to grade IV. The remaining 36 patients (83.7%) showed no change in facial nerve function. There was no difference in H-B grade according to tumor size at the time of diagnosis or change in tumor size. CONCLUSION: We conducted a large-scale observational study of FNS with good facial nerve function. Our study showed that many patients maintained facial nerve function during long-term follow-up. Conservative management with regular examination and imaging can be an appropriate option for managing FNS with good facial nerve function.

3.
J Korean Med Sci ; 37(23): e182, 2022 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-35698836

RESUMO

BACKGROUND: The aim of this study is to investigate the clinical effectiveness of Ponto in Korea, a recently released percutaneous bone-anchored hearing implant. METHODS: 16 patients with single-sided deafness (SSD) and mixed or conductive hearing loss who underwent Ponto implantation from December 2018 to September 2020 were enrolled in the study. Puretone audiometry, the Korean version of the Hearing in Noise Test (K-HINT), sound localization test (SLT), and Pupillometry were performed pre- and three months post-operation. Standardized questionnaires, the Hearing Handicap Inventory for the Elderly (HHIE) and Speech, Spatial and Qualities of Hearing Scale (SSQ), were administered. RESULTS: The mean age of subjects was 55.5 (range, 48-67) years. Four males and 12 females participated in the study. The mean puretone average was 73.17 dB hearing level (HL) before surgery and significantly improved to 36.72 dB HL three months after surgery. The mean word recognition score improved from 26.0% to 90.75% after implantation. In the case of K-HINT, there was a significant difference in summation (Z = -2.250, P = 0.024) and head shadow effects (Z = -3.103, P = 0.002). There was no significant difference in root mean square error degree (RMSE) and hemifield identification scores for SLT testing. Pupillometry was performed to measure listening effort and the results revealed that the degree of pupillary dilatation decreased under the condition of quiet, 0 dB signal to noise ratio (SNR) and 3 dB SNR. The total score for HHIE decreased significantly (Z = -3.130, P = 0.002) while the SSQ score increased significantly (Z = -2.216, P = 0.027). CONCLUSIONS: The Ponto bone-anchored hearing system showed significant clinical benefit in Korean patients with conductive and mixed hearing loss and SSD.


Assuntos
Auxiliares de Audição , Percepção da Fala , Idoso , Feminino , Audição , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/cirurgia , Testes Auditivos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
J Korean Med Sci ; 37(2): e11, 2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35014225

RESUMO

BACKGROUND: The purpose of this study was two-fold: 1) to identify differences in the characteristics of adopters and non-adopters of hearing aids (HAs); and 2) to investigate factors influencing the purchase of HA. METHODS: This study was conducted among 1,464 subjects (818 male and 646 female) with hearing loss. A national face-to-face survey was performed from August 2019 to October 2020 by otologists or HA experts. The questionnaire consisted of three domains: demographic, audiological, and HA-related domains. Multivariate logistic regression analysis was performed after adjusting for degree of hearing loss. RESULTS: The mean age of the participants was 70.4 ± 12.2 years. Of the 1,464 respondents, 1,190 (81.3%) had already purchased HA. We identified educational level, household income, hearing loss period, place of HA purchase, and government HA assistance program status as factors influencing HA adoption. Among these factors, third party reimbursement was the most important factor affecting HA purchase intent. The main reasons for not adopting HA were feeling that their hearing was adequate, inability to afford HA, and perceptions that HA are uncomfortable. CONCLUSION: Various factors are involved in the purchase of HA, but disabled registration status and third party reimbursement were identified as the most critical factors. In the future, the government should take a more active role in increasing the distribution of HA to patients with hearing loss.


Assuntos
Auxiliares de Audição , Perda Auditiva/psicologia , Perda Auditiva/reabilitação , Aceitação pelo Paciente de Cuidados de Saúde , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia , Estudos Retrospectivos
5.
J Korean Med Sci ; 37(12): e94, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35347902

RESUMO

BACKGROUND: Hearing loss (HL) is the most common chronic disease and has been linked to negative health outcomes. Hearing aids (HAs) are regarded as the gold standard for HL management, however, the adoption rate of HAs is relatively low for various reasons. With this background, hearing devices, such as personal sound amplification products (PSAPs) received significant attention as an alternative to conventional HAs. This study aimed to evaluate the clinical efficacy of PSAPs in patients with mild to moderately severe HL. METHODS: Nineteen patients with mild hearing loss (MHL), 23 with moderate hearing loss (MDHL), and 15 with moderately severe hearing loss (MSHL) participated in the study. Electroacoustic analysis, simulated real-ear measurements (REMs), and three clinical evaluations were implemented. RESULTS: All devices satisfied the electroacoustic tolerances. All devices provided sufficient gain for MHL and MDHL audiograms. However, in MSHL audiogram, the gains of PSAPs were insufficient, especially for high frequencies. In terms of clinical evaluations, sound-field audiometry showed significant improvements between aided and unaided thresholds in all groups for all devices (P < 0.001). Significant improvements of word recognition scores were only shown for HAs between aided and unaided conditions. The Korean version of the Hearing In Noise Test did not show any consistent findings for all devices and groups. CONCLUSION: Certain PSAPs are beneficial for improving hearing and speech perception in patients with HL. Well-chosen PSAPs could be an alternative hearing rehabilitation option for these patients.


Assuntos
Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Audição , Testes Auditivos , Humanos
6.
Eur Arch Otorhinolaryngol ; 279(3): 1243-1249, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33834275

RESUMO

PURPOSE: Although the estimated prevalence is extremely low, facial nerve schwannoma (FNS) is the most common primary tumor of the facial nerve (FN). In the present study, the outcome of surgical management in 18 patients with FNS was analyzed and an appropriate time for surgery was proposed. MATERIALS AND METHODS: A total of 18 patients with FNS who underwent surgical management by a single surgeon from 1999 to 2018 were retrospectively analyzed. RESULTS: Among the 18 patients, five had no facial paralysis before surgery. Near-total removal was performed in three cases, and two cases were managed with decompression. In 13 cases with various degree of preoperative facial palsy, nerve continuity was lost during surgery. FN was reconstructed using cable graft in ten cases, direct anastomosis in one case, and facial-hypoglossal nerve transfer in one case. Facial reanimation surgery without FN reconstruction was performed in one case due to a long-standing facial paralysis before surgery. Preoperative House-Brackmann (H-B) grade in all patients was significantly worse as tumor size increased. The correlation was not observed between the duration and severity of preoperative facial palsy. Analysis of 12 patients who underwent FN reconstruction revealed that all patients with good preoperative facial function (H-B grade II-III) recovered to H-B grade III after surgery (7/7, 100%). However, patients with poor preoperative facial function (H-B grade IV or worse) had only a 40% (2/5) chance of improving to grade III after surgery. Preoperative tumor size and duration of facial palsy did not affect postoperative final facial function. CONCLUSION: We suggest that H-B grade III facial palsy is the best time for surgical intervention, regardless of the tumor size or duration of facial palsy.


Assuntos
Neoplasias dos Nervos Cranianos , Paralisia Facial , Neurilemoma , Neoplasias dos Nervos Cranianos/cirurgia , Nervo Facial , Paralisia Facial/etiologia , Paralisia Facial/patologia , Paralisia Facial/cirurgia , Humanos , Neurilemoma/patologia , Neurilemoma/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
J Med Internet Res ; 23(9): e29678, 2021 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-34546181

RESUMO

BACKGROUND: Recently, the analysis of endolymphatic hydropses (EHs) via inner ear magnetic resonance imaging (MRI) for patients with Ménière disease has been attempted in various studies. In addition, artificial intelligence has rapidly been incorporated into the medical field. In our previous studies, an automated algorithm for EH analysis was developed by using a convolutional neural network. However, several limitations existed, and further studies were conducted to compensate for these limitations. OBJECTIVE: The aim of this study is to develop a fully automated analytic system for measuring EH ratios that enhances EH analysis accuracy and clinical usability when studying Ménière disease via MRI. METHODS: We proposed the 3into3Inception and 3intoUNet networks. Their network architectures were based on those of the Inception-v3 and U-Net networks, respectively. The developed networks were trained for inner ear segmentation by using the magnetic resonance images of 124 people and were embedded in a new, automated EH analysis system-inner-ear hydrops estimation via artificial intelligence (INHEARIT)-version 2 (INHEARIT-v2). After fivefold cross-validation, an additional test was performed by using 60 new, unseen magnetic resonance images to evaluate the performance of our system. The INHEARIT-v2 system has a new function that automatically selects representative images from a full MRI stack. RESULTS: The average segmentation performance of the fivefold cross-validation was measured via the intersection of union method, resulting in performance values of 0.743 (SD 0.030) for the 3into3Inception network and 0.811 (SD 0.032) for the 3intoUNet network. The representative magnetic resonance slices (ie, from a data set of unseen magnetic resonance images) that were automatically selected by the INHEARIT-v2 system only differed from a maximum of 2 expert-selected slices. After comparing the ratios calculated by experienced physicians and those calculated by the INHEARIT-v2 system, we found that the average intraclass correlation coefficient for all cases was 0.941; the average intraclass correlation coefficient of the vestibules was 0.968, and that of the cochleae was 0.914. The time required for the fully automated system to accurately analyze EH ratios based on a patient's MRI stack was approximately 3.5 seconds. CONCLUSIONS: In this study, a fully automated full-stack magnetic resonance analysis system for measuring EH ratios was developed (named INHEARIT-v2), and the results showed that there was a high correlation between the expert-calculated EH ratio values and those calculated by the INHEARIT-v2 system. The system is an upgraded version of the INHEARIT system; it has higher segmentation performance and automatically selects representative images from an MRI stack. The new model can help clinicians by providing objective analysis results and reducing the workload for interpreting magnetic resonance images.


Assuntos
Aprendizado Profundo , Hidropisia Endolinfática , Doença de Meniere , Inteligência Artificial , Hidropisia Endolinfática/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Doença de Meniere/diagnóstico por imagem
8.
ORL J Otorhinolaryngol Relat Spec ; 83(3): 172-180, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33626533

RESUMO

HYPOTHESIS: The endolymphatic hydrops (EH) does not affect hearing loss significantly at low frequencies, whereas the hydrops affects the diplacusis. BACKGROUND: There have been many arguments whether the EH cause the Meniere disease. Despite a lot of experimental studies to investigate the Meniere disease, there have been little modeling studies, which are helpful to understand the mechanism. METHODS: A 3D finite element model of the human cochlea and the middle ear was used for investigation of the relationship between EH and hearing loss at low frequencies and diplacusis (2 specific symptoms of Meniere disease). While the cochlear geometry was simplified as a tapered box shape, the middle ear was based on the real geometry obtained from µCT images. EH is implemented by prestress on the basilar membrane surface in the simulation. RESULTS: The EH did not cause significant hearing loss at low frequencies in both air- and bone-conducted hearing. Rather, this disorder caused a shift in best frequency (BF) position to the base at low frequencies below about 250 Hz. The BF shift can explain the diplacusis because a low-frequency sound can be perceived as a slightly higher frequency so that Meniere patients can perceive 2 different frequency sounds corresponding to a given single-frequency sound. CONCLUSION: The EH cannot be a sufficient condition for Meniere disease, whereas the hydrops can cause the diplacusis.


Assuntos
Hidropisia Endolinfática , Doença de Meniere , Acústica , Hidropisia Endolinfática/diagnóstico , Hidropisia Endolinfática/diagnóstico por imagem , Audição , Testes Auditivos , Humanos , Imageamento por Ressonância Magnética , Doença de Meniere/complicações , Doença de Meniere/diagnóstico
9.
J Nanosci Nanotechnol ; 19(10): 6398-6407, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31026968

RESUMO

Polymeric nanoparticles with sufficient solid concentration could be synthesized by emulsion polymerization without using surfactants. The polymeric nano-colloids with surface functional groups were synthesized to obtain carboxylated polystyrene beads or amidine polystyrene nanoparticles. Sodium styrene sulfonate was also adopted for the synthesis of sulfonated polystyrene nanoparticles less than 50 nm in diameter using KPS as an initiator. The diameter of the carboxylated particles could be controlled by adjusting the reaction parameters such as the amount of monomer, cross-linker, and polymerization temperature. The range of the diameter of the resulting polymeric beads was 100 to 200 nm, which is useful size range for bio-sensing purposes. Amidine polystyrene nanoparticles less than 50 nm could be fabricated using a cationic comonomer, MTC. As an application of the polymeric beads, the porous inorganic particles could be synthesized by colloidal templating using emulsions as micro-reactors.

10.
J Nanosci Nanotechnol ; 18(9): 6112-6121, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29677752

RESUMO

We report on the synthesis of porous silica particles by self-assembly routes in a continuous manner for application to thermal insulators. A continuous process was employed to produce tiny droplets containing precursor materials such as silica and organic templates for self-organization to fabricate particles with well defined pores. A rotating cylinder system or a spray drying process was adopted to form emulsions or aerosol droplets as micro-reactors for self-assembly, and the physical properties including the thermal conductivity of the resulting porous particles were compared between the two methods. The porous particles could be coated as a thick film by solution dripping, and the fluorination treatment using a silane coupling agent was performed to produce superhydrophobic surfaces of insulating layers by a lotus effect.

11.
J Chem Phys ; 144(2): 024311, 2016 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-26772575

RESUMO

All available "conventional" absorption/emission spectroscopic data have been combined with photodissociation data and translational spectroscopy data in a global analysis that yields analytic potential energy and Born-Oppenheimer breakdown functions for the X(1)Σ(+) and A(1)Π states of CH(+) and its isotopologues that reproduce all of the data (on average) within their assigned uncertainties. For the ground X(1)Σ(+) state, this fully quantum mechanical "Direct-Potential-Fit" analysis yielded an improved empirical well depth of 𝔇e = 34 362.8(3) cm(-1) and equilibrium bond length of re = 1.128 462 5 (58) Å. For the A(1)Π state, the resulting well depth and equilibrium bond length are 𝔇e = 10 303.7(3) cm(-1) and re = 1.235 896 (14) Å, while the electronic isotope shift from the hydride to the deuteride is ΔTe = - 5.99(±0.08) cm(-1).

14.
Clin Exp Otorhinolaryngol ; 17(1): 37-45, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38228133

RESUMO

OBJECTIVES: As cochlear implantation (CI) experiences rapid innovations and its indications expand, the characteristics of revision CI (RCI) are evolving. This study investigated changes in the RCI profile and explored their clinical implications. METHODS: A retrospective chart review was conducted of all CIs performed at a tertiary medical institution between October 2001 and January 2023. The rates of and reasons for RCI were evaluated in relation to the manufacturer and device model. Kaplan-Meier analysis was employed to examine cumulative and device survival curves. Cumulative and device survival rates were additionally analyzed based on age group, period of primary CI, and manufacturer. A Cox proportional hazards model was employed to evaluate the association between RCI and the device manufacturer. RESULTS: Among 1,430 CIs, 73 (5.1%) required RCI. The predominant reason for RCI was device failure (40 of 73 RCIs [54.8%]), with an overall device failure rate of 2.8%. This was followed by flap-associated problems and migration (nine of 73 RCIs each [12.3%]). Flap retention issues emerged as a new cause in three cases (two involving the CI 632 and one involving the SYNCHRONY 2 implant), and six instances of electrode tip fold-over arose (four for the CI 600 series and two for the CI 500 series). The overall 10-year cumulative and device survival rates were 93.4% and 95.8%, respectively. After excluding models with recall issues, significant differences in cumulative (P =0.010) and device (P =0.001) survival rates were observed across manufacturers. CONCLUSION: While the overall CI survival rate is stable, device failure persists as the predominant reason for RCI. Moreover, the types of complications leading to revision (including issues with flap retention and electrode tip fold-over) have shifted, particularly for newer implant models. Given the clinical importance of device failure and subsequent reoperation, clinicians should remain informed about and responsive to these trends.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38738912

RESUMO

OBJECTIVE: To examine the clinical characteristics and auditory performance of patients with CHARGE syndrome following cochlear implantation (CI), as well as the prognostic factors affecting auditory outcomes. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary academic center. METHODS: A retrospective chart review was performed in patients with CHARGE syndrome who underwent CI from 2007 to 2022. The category of auditory performance (CAP) score was used to assess the CI outcomes, and factors that may affect the speech outcomes were also evaluated. RESULTS: In 14 children with CHARGE syndrome, 22 CIs were performed, 6 unilaterally and 8 bilaterally. The mean age at CI was 25.9 months (range: 10-62). All patients had ear abnormalities and developmental delays, and cochlear nerve deficiency (CND) was present in all ears. At the last follow-up (mean: 49.6 months), the mean CAP score improved significantly compared to the preoperative measure (from 0.36 ± 0.81 to 3.21 ± 1.70, P = .001), with 6 patients (42.9%) achieving a CAP score of 4 points or higher. However, between the unilateral and bilateral CI groups, the final CAP score or change in CAP score was similar. Factors including age, coloboma, and CND did not significantly affect speech outcomes (all P > .05). CONCLUSION: Even though CHARGE syndrome features challenging anomalies, CI can be conducted safely and can offer effective contribution to significant speech improvement. Patients with CHARGE syndrome should be given the opportunity to undergo CI to maximize their audiological progress.

16.
Brain Behav ; 14(2): e3389, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38391108

RESUMO

OBJECTIVES: Persistent postural-perceptual dizziness (PPPD) is a chronic functional vestibular disorder for which the Bárány Society has established diagnostic criteria. This nationwide multicenter study aims to investigate the clinical features of individuals with definite PPPD and clinical variant PPPD who do not fully meet the diagnostic criteria, with a particular focus on visual exaggeration. METHODS: Between September 2020 and September 2021, a total of 76 individuals with definite PPPD and 109 individuals with clinical variant PPPD who did not meet all three exacerbating factors outlined in Criterion B were recruited from 18 medical centers in South Korea. The study gathered information on demographic factors, clinical manifestations, balance scales, and personality assessments. RESULTS: Comparative analysis between groups with definite PPPD and clinical variant with visual exacerbation revealed no significant differences in sociodemographic characteristics, clinical course, dizziness impact, and specific precipitants. Only disease duration was significantly longer in definite PPPD compared with variant with visual exacerbation. However, the variant without visual exacerbation displayed significantly reduced rates of panic disorder, diminished space-motion discomfort, lesser impact of dizziness, and decreased prevalence of depression when compared with the definitive PPPD. CONCLUSION: This is the first comprehensive nationwide study examining clinical features of both definite PPPD patients and its clinical variants, considering visual exacerbating factors. Differences in dizziness and personality traits emerged between definite PPPD and its potential variant without visual issues. Our results highlight the possibility of a distinct clinical variant of PPPD influenced by visual dependency.


Assuntos
Tontura , Doenças Vestibulares , Humanos , Tontura/diagnóstico , Tontura/epidemiologia , Estudos Transversais , Vertigem , Doenças Vestibulares/diagnóstico , Doenças Vestibulares/epidemiologia , República da Coreia/epidemiologia
17.
Yonsei Med J ; 64(10): 618-624, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37727921

RESUMO

PURPOSE: Tinnitus is one of the most common health conditions worldwide. Although various methods of treatment have been used, the condition is still difficult to manage or cure. This study aimed to evaluate the therapeutic effects of transcutaneous trigeminal electrical stimulation (TTES) combined with notched sound therapy (NST) on patients with tinnitus. MATERIALS AND METHODS: A clinical trial was conducted prospectively from September 2020 to September 2021 at a single center in South Korea. In total, 14 patients took part in this trial. Periodic visits and tele-monitoring were used to assess treatment compliance and collect data, including electroencephalography (EEG), photoplethysmography (PPG), tinnitus handicap inventory (THI), tinnitus magnitude index, Beck Depression Inventory (BDI), Pittsburgh Sleep Quality Index (PSQI), and 36-item short-form survey (SF-36) results. RESULTS: Changes after intervention were analyzed with paired t-test. This study showed that alpha waves in the left hemisphere measured by EEG (p=0.024), autonomic nervous system balance (p=0.007), and stress level (p=0.022) measured by PPG significantly changed after intervention. Also, THI scores especially emotional symptoms (p=0.029) and catastrophic symptoms (p=0.043) decreased after treatment. The SF-36 score, both mental component summary and physical component summary score (each p<0.001), increased significantly, whereas the PSQI score (p<0.001) and BDI score (p<0.001) decreased after TTES and NST. CONCLUSION: Based on the results of our study, we could confirm that TTES combined with NST can significantly improve tinnitus, catastrophic symptoms, and the overall quality of life of patients.


Assuntos
Qualidade de Vida , Zumbido , Humanos , Zumbido/terapia , Sistema Nervoso Autônomo , Emoções , Estimulação Elétrica
18.
Clin Exp Otorhinolaryngol ; 16(4): 334-341, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37641856

RESUMO

OBJECTIVES: Acute low-tone sensorineural hearing loss (ALHL) is thought to have a different etiology from that of idiopathic sudden sensorineural hearing loss. We hypothesized that endolymphatic hydrops (EH) in the inner ear organ contributes to ALHL, even in patients without vertigo. This study investigated the presence of EH in ALHL and compared the clinical characteristics of patients with or without EH. METHODS: We retrospectively reviewed 38 patients diagnosed with ALHL without vertigo from January 2017 to March 2022. EH was measured in all patients using inner ear magnetic resonance imaging (MRI). In addition, we selected patients who showed only mid- or high-frequency hearing loss and had available MRI data as a control group and compared the ALHL and control groups. RESULTS: After treatment, the pure-tone average at low frequencies significantly improved compared to the initial hearing (P<0.001). Hearing recovery was observed in 63.1% of patients; however, the recovery rate did not differ based on the treatment method. During the follow-up period, six patients (15.8%) progressed to Meniere's disease, and 18 (47.4%) experienced recurrence. In the ALHL group, the cochlear hydrops ratio on the affected side (0.34±0.09) was significantly higher than on the contralateral side (0.29±0.12) (P=0.005), and most patients showed hydrops in the apex area of the cochlea. Compared with the control group (0.25±0.15), the ALHL group showed a significantly higher cochlear hydrops ratio (P=0.043). The correlation analysis showed a tendency for hearing thresholds at low frequencies to increase as the hydrops ratio increased, albeit without statistical significance. CONCLUSION: The cochlear hydrops ratio, especially in the apex area on the affected side, was significantly higher in patients with ALHL, suggesting that EH in the cochlea contributes to the pathogenesis of ALHL.

19.
J Clin Med ; 12(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37762724

RESUMO

Tinnitus is the perception of abnormal sounds in the ears or head without external auditory stimulation. While classical test theory is often used in tinnitus questionnaire development, it has limitations in assessing item characteristics. Item response theory (IRT) offers more precise individual ability estimations and identifies key and less important items, making it superior for reliable measurement tools. This study investigated the suitability of the Korean version of the Tinnitus Handicap Inventory (K-THI) as a patient-reported outcome measure (PROM) for clinical trials. Using Rasch analysis based on IRT, we evaluated K-THI's measurement of tinnitus-related disability in 545 patients (40.4% men, 59.6% women). Five items (2, 7, 8, 19, and 24) did not fit the Rasch model, yet a unidimensional scale and good fit for person and item data emerged (person: 0.89; item: 0.98). The three-point rating scale in K-THI proved suitable. IRT allowed precise evaluation of K-THI's properties, vital for reliable PROMs in patient-centered care. Our findings highlight IRT's role in questionnaire development, contributing to the advancement of PROMs.

20.
ACS Biomater Sci Eng ; 9(6): 3512-3521, 2023 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-37126860

RESUMO

This study aimed to investigate the effect of electrical stimulation on poly(d,l-lactide-co-ε-caprolactone) nerve guidance conduits (NGCs) in promoting the recovery of facial function and nerve regeneration after facial nerve (FN) injury in a rat model. In the experimental group, both the NGC and transcutaneous electrical nerve stimulation (ES) were used simultaneously; in the control group, only NGC was used. ES groups were divided into two groups, and direct current (DC) and charge-balanced pulse stimulation (Pulse) were applied. The ES groups showed significantly improved whisker movement than the NGC-only group. The number of myelinated neurons was higher in ES groups, and the myelin sheath was also thicker and more uniform. In addition, the expression of neurostructural proteins was also higher in ES groups than in the NGC-only group. This study revealed that FN regeneration and functional recovery occurred more efficiently when ES was applied in combination with NGCs.


Assuntos
Nervo Facial , Regeneração Tecidual Guiada , Ratos , Animais , Ratos Sprague-Dawley , Nervo Isquiático/lesões , Nervo Isquiático/cirurgia , Regeneração Nervosa/fisiologia , Estimulação Elétrica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA