Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Innov ; 22(6): 621-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25712086

RESUMO

INTRODUCTION: The proximity of instrumentation in single-incision laparoscopic surgery (SILS) creates ergonomic challenges. An innovative method to reduce external collisions between instruments and handles is to use instruments of different lengths. This study evaluated the impact of instrument and laparoscope length on simulated SILS performance. METHODS: Performance was assessed using peg transfer (PEG) and pattern cutting (CUT) tasks from the Fundamentals of Laparoscopic Surgery (FLS) curriculum. Following baseline testing, surgeons were randomized into 3 trial arms: Control--standard length instruments and standard length laparoscope; group 1--one long instrument, one standard length instrument and standard length laparoscope; and group 2--standard length instruments and long laparoscope. Two phases were undertaken using a validated SILS-modified FLS box trainer: phase 1--25 repetitions of PEG and phase 2--5 repetitions of CUT. FLS scoring parameters measured performance and the Imperial College Surgical Assessment Device (ICSAD) captured motion analysis of hands. RESULTS: Twenty-three surgeons were recruited--control (n = 7), group 1 (n = 9), and group 2 (n = 7). No significant differences were observed in operative experience or baseline skills performance. Phase 1: Peak FLS score was significantly higher in group 1 compared with control (P = .009). Comparison of learning curves revealed learning plateau was significantly higher in group 1 compared with control (P = .010). Phase 2: Group 1 revealed a trend toward higher peak FLS scores over the control (P = .067). No significant differences in motion analysis of hands were demonstrated using ICSAD. CONCLUSIONS: This study demonstrates that using instruments of different lengths can improve simulated SILS performance.


Assuntos
Ergonomia/instrumentação , Laparoscopia/educação , Laparoscopia/instrumentação , Curva de Aprendizado , Cirurgiões/educação , Cirurgiões/estatística & dados numéricos , Adulto , Simulação por Computador , Feminino , Humanos , Masculino
2.
J Surg Educ ; 72(1): 1-7, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25218370

RESUMO

OBJECTIVE: In single-incision laparoscopic surgery (SILS), operating through 1 incision presents ergonomic challenges. No consensus exists on whether articulating instruments (ARTs) may help. This study evaluated their effect on simulated SILS, hypothesizing that they would affect performance and workload. DESIGN: Surgeons were randomized to 2 straight instruments (STRs), 1 ART and 1 STR, or 2 ARTs. After baseline testing, 25 repetitions of the Fundamentals of Laparoscopic Surgery (FLS) peg-transfer (PEG) task and 5 repetitions of the short-hand for the FLS pattern-cutting task (CIRCLE) were performed. Primary outcomes were maximum FLS PEG scores, CIRCLE times and errors, and Imperial College Surgical Assessment Device hand motion analysis. National Aeronautics and Space Administration (NASA) Raw Task Load Index (RTLX) questionnaires evaluated a secondary outcome--workload. SETTING: The trial took place in a simulated operating theater within the Academic Surgical Unit at St Mary's Hospital, London, UK. PARTICIPANTS: Eligible surgeons had completed at least 5 laparoscopic cases as a primary operator. Surgeons were stratified by laparoscopic experience into intermediate (less than 25 previous procedures as primary operator) or advanced (25 procedures or more). A total of 21 surgeons were recruited and randomized; 7 of them to each instrument combination group. All surgeons completed PEG, and 5 from each group completed CIRCLE. RESULTS: Groups' baseline PEG scores were similar (p = 0.625). STR-ART achieved higher maximum PEG scores than STR or ART did (median = 236 vs 198 vs 193, respectively, p = 0.002). Fastest CIRCLE times were similar (median = 190s vs 130s vs 186s, p = 0.129) as were minimum errors (median = 1 vs 2 vs 3, p = 0.101). For PEG, Imperial College Surgical Assessment Device demonstrated similar total path lengths (median = 12.3m vs 12.3m vs 16.0m, p = 0.545) and total numbers of movements (median = 89.6 vs 86.4 vs 171, p = 0.080). Groups' NASA Raw Task Load Index scores were similar (p = 0.708). CONCLUSIONS: Combining 1 STR and 1 ART improved SILS performance in the PEG task. Therefore, this may be the optimum instrument configuration for use within some clinical SILS applications.


Assuntos
Cirurgia Geral/educação , Laparoscopia/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Laparoscopia/métodos , Masculino , Análise e Desempenho de Tarefas , Carga de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA