Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Exp Physiol ; 2024 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923603

RESUMO

We evaluated the impacts of COVID-19 on multi-organ and metabolic function in patients following severe hospitalised infection compared to controls. Patients (n = 21) without previous diabetes, cardiovascular or cerebrovascular disease were recruited 5-7 months post-discharge alongside controls (n = 10) with similar age, sex and body mass. Perceived fatigue was estimated (Fatigue Severity Scale) and the following were conducted: oral glucose tolerance (OGTT) alongside whole-body fuel oxidation, validated magnetic resonance imaging and spectroscopy during resting and supine controlled exercise, dual-energy X-ray absorptiometry, short physical performance battery (SPPB), intra-muscular electromyography, quadriceps strength and fatigability, and daily step-count. There was a greater insulin response (incremental area under the curve, median (inter-quartile range)) during the OGTT in patients [18,289 (12,497-27,448) mIU/min/L] versus controls [8655 (7948-11,040) mIU/min/L], P < 0.001. Blood glucose response and fasting and post-prandial fuel oxidation rates were not different. This greater insulin resistance was not explained by differences in systemic inflammation or whole-body/regional adiposity, but step-count (P = 0.07) and SPPB scores (P = 0.004) were lower in patients. Liver volume was 28% greater in patients than controls, and fat fraction adjusted liver T1, a measure of inflammation, was raised in patients. Patients displayed greater perceived fatigue scores, though leg muscle volume, strength, force-loss, motor unit properties and post-exercise muscle phosphocreatine resynthesis were comparable. Further, cardiac and cerebral architecture and function (at rest and on exercise) were not different. In this cross-sectional study, individuals without known previous morbidity who survived severe COVID-19 exhibited greater insulin resistance, pointing to a need for physical function intervention in recovery.

2.
Nephrol Dial Transplant ; 39(2): 233-241, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-37433572

RESUMO

BACKGROUND: Ischaemic end-organ damage during haemodialysis (HD) is a significant problem that may be ameliorated by intradialytic cooling. A randomised trial was performed to compare standard HD (SHD; dialysate temperature 37°C) and programmed cooling of the dialysate [thermocontrolled HD (TCHD)] using multiparametric magnetic resonance imaging (MRI) to assess structural, functional and blood flow changes in the heart, brain and kidneys. METHODS: Prevalent HD patients were randomly allocated to receive either SHD or TCHD for 2 weeks before undergoing serial MRI at four time points: pre-, during (30 min and 180 min) and post-dialysis. MRI measures include cardiac index, myocardial strain, longitudinal relaxation time (T1), myocardial perfusion, internal carotid and basilar artery flow, grey matter perfusion and total kidney volume. Participants then crossed to the other modality to repeat the study protocol. RESULTS: Eleven participants completed the study. Separation in blood temperature between TCHD (-0.1 ± 0.3°C) and SHD (+0.3 ± 0.2°C; P = .022) was observed, although there was no difference in tympanic temperature changes between arms. There were significant intradialytic reductions in cardiac index, cardiac contractility (left ventricular strain), left carotid and basilar artery blood flow velocities, total kidney volume, longitudinal relaxation time (T1) of the renal cortex and transverse relaxation rate (T2*) of the renal cortex and medulla, but no differences between arms. Pre-dialysis T1 of the myocardium and left ventricular wall mass index were lower after 2 weeks of TCHD compared with SHD [1266 ms (interquartile range 1250-1291) versus 1311 ± 58 ms, P = .02; 66 ± 22 g/m2 versus 72 ± 23 g/m2, P = .004]. CONCLUSIONS: HD adversely affects cardiac function, reduces carotid and basilar artery blood flow and total kidney volume, but mild dialysate cooling using a biofeedback module did not result in differences in intradialytic MRI measures compared with SHD.


Assuntos
Falência Renal Crônica , Diálise Renal , Humanos , Diálise Renal/efeitos adversos , Diálise Renal/métodos , Rim , Soluções para Diálise , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem
3.
J Magn Reson Imaging ; 58(6): 1660-1679, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37243378

RESUMO

Renal diseases pose a significant socio-economic burden on healthcare systems. The development of better diagnostics and prognostics is well-recognized as a key strategy to resolve these challenges. Central to these developments are MRI biomarkers, due to their potential for monitoring of early pathophysiological changes, renal disease progression or treatment effects. The surge in renal MRI involves major cross-domain initiatives, large clinical studies, and educational programs. In parallel with these translational efforts, the need for greater (patho)physiological specificity remains, to enable engagement with clinical nephrologists and increase the associated health impact. The ISMRM 2022 Member Initiated Symposium (MIS) on renal MRI spotlighted this issue with the goal of inspiring more solutions from the ISMRM community. This work is a summary of the MIS presentations devoted to: 1) educating imaging scientists and clinicians on renal (patho)physiology and demands from clinical nephrologists, 2) elucidating the connection of MRI parameters with renal physiology, 3) presenting the current state of leading MR surrogates in assessing renal structure and functions as well as their next generation of innovation, and 4) describing the potential of these imaging markers for providing clinically meaningful renal characterization to guide or supplement clinical decision making. We hope to continue momentum of recent years and introduce new entrants to the development process, connecting (patho)physiology with (bio)physics, and conceiving new clinical applications. We envision this process to benefit from cross-disciplinary collaboration and analogous efforts in other body organs, but also to maximally leverage the unique opportunities of renal physiology. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Nefropatias , Rim , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Nefropatias/diagnóstico por imagem , Néfrons , Testes de Função Renal
4.
J Magn Reson Imaging ; 55(2): 323-335, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33140551

RESUMO

BACKGROUND: Phase-contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC-MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC-MRI as a clinically useful tool. PURPOSE: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC-MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies. STUDY TYPE: Systematic consensus process using a modified Delphi method. POPULATION: Not applicable. SEQUENCE FIELD/STRENGTH: Renal fast gradient echo-based 2D PC-MRI. ASSESSMENT: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4-10) years of experience in 2D PC-MRI formulated consensus statements on renal 2D PC-MRI in two rounds of surveys. Starting from a recently published systematic review article, literature-based and data-driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated. STATISTICAL TESTS: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60-74% agreement among the experts. RESULTS: Among 60 statements, 57 (95%) achieved consensus after the second-round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC-MRI data acquisition, processing, and reporting. DATA CONCLUSION: These recommendations might promote a widespread adoption of renal PC-MRI, and may help foster the set-up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC-MRI. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Rim , Imageamento por Ressonância Magnética , Consenso , Técnica Delphi , Humanos , Estudos Multicêntricos como Assunto , Circulação Renal
5.
Crit Care ; 26(1): 262, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36050748

RESUMO

BACKGROUND: Renal hypoperfusion has been suggested to contribute to the development of acute kidney injury (AKI) in critical COVID-19. However, limited data exist to support this. We aim to investigate the differences in renal perfusion, oxygenation and water diffusion using multiparametric magnetic resonance imaging in critically ill COVID-19 patients with and without AKI. METHODS: A prospective case-control study where patients without prior kidney disease treated in intensive care for respiratory failure due to COVID-19 were examined. Kidney Disease: Improving Global Outcomes Creatinine criteria were used for group allocation. Main comparisons were tested using Mann-Whitney U test. RESULTS: Nineteen patients were examined, ten with AKI and nine without AKI. Patients with AKI were examined in median 1 [0-2] day after criteria fulfillment. Age and baseline Plasma-Creatinine were similar in both groups. Total renal blood flow was lower in patients with AKI compared with patients without (median 645 quartile range [423-753] vs. 859 [746-920] ml/min, p = 0.037). Regional perfusion was reduced in both cortex (76 [51-112] vs. 146 [123-169] ml/100 g/min, p = 0.015) and medulla (28 [18-47] vs. 47 [38-73] ml/100 g/min, p = 0.03). Renal venous saturation was similar in both groups (72% [64-75] vs. 72% [63-84], ns.), as was regional oxygenation (R2*) in cortex (17 [16-19] vs. 17 [16-18] 1/s, ns.) and medulla (29 [24-39] vs. 27 [23-29] 1/s, ns.). CONCLUSIONS: In critically ill COVID-19 patients with AKI, the total, cortical and medullary renal blood flows were reduced compared with similar patients without AKI, whereas no differences in renal oxygenation were demonstrable in this setting. Trial registration ClinicalTrials ID: NCT02765191 , registered May 6 2014 and updated May 7 2020.


Assuntos
Injúria Renal Aguda , COVID-19 , Injúria Renal Aguda/diagnóstico por imagem , COVID-19/complicações , Estudos de Casos e Controles , Creatinina , Estado Terminal , Humanos , Espectroscopia de Ressonância Magnética , Perfusão
6.
Magn Reson Med ; 86(2): 1125-1136, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33755256

RESUMO

PURPOSE: Total kidney volume (TKV) is an important measure in renal disease detection and monitoring. We developed a fully automated method to segment the kidneys from T2 -weighted MRI to calculate TKV of healthy control (HC) and chronic kidney disease (CKD) patients. METHODS: This automated method uses machine learning, specifically a 2D convolutional neural network (CNN), to accurately segment the left and right kidneys from T2 -weighted MRI data. The data set consisted of 30 HC subjects and 30 CKD patients. The model was trained on 50 manually defined HC and CKD kidney segmentations. The model was subsequently evaluated on 50 test data sets, comprising data from 5 HCs and 5 CKD patients each scanned 5 times in a scan session to enable comparison of the precision of the CNN and manual segmentation of kidneys. RESULTS: The unseen test data processed by the 2D CNN had a mean Dice score of 0.93 ± 0.01. The difference between manual and automatically computed TKV was 1.2 ± 16.2 mL with a mean surface distance of 0.65 ± 0.21 mm. The variance in TKV measurements from repeat acquisitions on the same subject was significantly lower using the automated method compared to manual segmentation of the kidneys. CONCLUSION: The 2D CNN method provides fully automated segmentation of the left and right kidney and calculation of TKV in <10 s on a standard office computer, allowing high data throughput and is a freely available executable.


Assuntos
Redes Neurais de Computação , Insuficiência Renal Crônica , Humanos , Processamento de Imagem Assistida por Computador , Rim/diagnóstico por imagem , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Insuficiência Renal Crônica/diagnóstico por imagem
7.
Am J Physiol Renal Physiol ; 319(6): F966-F978, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33073586

RESUMO

Circadian regulation of kidney function is involved in maintaining whole body homeostasis, and dysfunctional circadian rhythm can potentially be involved in disease development. Magnetic resonance imaging (MRI) provides reliable and reproducible repetitive estimates of kidney function noninvasively without the risk of adverse events associated with contrast agents and ionizing radiation. The purpose of this study was to estimate circadian variations in kidney function in healthy human subjects with MRI and to relate the findings to urinary excretions of electrolytes and markers of kidney function. Phase-contrast imaging, arterial spin labeling, and blood oxygen level-dependent transverse relaxation rate (R2*) mapping were used to assess total renal blood flow and regional perfusion as well as intrarenal oxygenation in eight female and eight male healthy volunteers every fourth hour during a 24-h period. Parallel with MRI scans, standard urinary and plasma parameters were quantified. Significant circadian variations of total renal blood flow were found over 24 h, with increasing flow from noon to midnight and decreasing flow during the night. In contrast, no circadian variation in intrarenal oxygenation was detected. Urinary excretions of electrolytes, osmotically active particles, creatinine, and urea all displayed circadian variations, peaking during the afternoon and evening hours. In conclusion, total renal blood flow and kidney function, as estimated from excretion of electrolytes and waste products, display profound circadian variations, whereas intrarenal oxygenation displays significantly less circadian variation.


Assuntos
Ritmo Circadiano/fisiologia , Rim/fisiologia , Imageamento por Ressonância Magnética , Circulação Renal/fisiologia , Adulto , Eletrólitos/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Masculino , Consumo de Oxigênio/fisiologia , Fatores Sexuais , Adulto Jovem
8.
Nephrol Dial Transplant ; 35(6): 955-964, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31257440

RESUMO

BACKGROUND: Multi-parametric magnetic resonance imaging (MRI) provides the potential for a more comprehensive non-invasive assessment of organ structure and function than individual MRI measures, but has not previously been comprehensively evaluated in chronic kidney disease (CKD). METHODS: We performed multi-parametric renal MRI in persons with CKD (n = 22, 61 ± 24 years) who had a renal biopsy and measured glomerular filtration rate (mGFR), and matched healthy volunteers (HV) (n = 22, 61 ± 25 years). Longitudinal relaxation time (T1), diffusion-weighted imaging, renal blood flow (phase contrast MRI), cortical perfusion (arterial spin labelling) and blood-oxygen-level-dependent relaxation rate (R2*) were evaluated. RESULTS: MRI evidenced excellent reproducibility in CKD (coefficient of variation <10%). Significant differences between CKD and HVs included cortical and corticomedullary difference (CMD) in T1, cortical and medullary apparent diffusion coefficient (ADC), renal artery blood flow and cortical perfusion. MRI measures correlated with kidney function in a combined CKD and HV analysis: estimated GFR correlated with cortical T1 (r = -0.68), T1 CMD (r = -0.62), cortical (r = 0.54) and medullary ADC (r = 0.49), renal artery flow (r = 0.78) and cortical perfusion (r = 0.81); log urine protein to creatinine ratio (UPCR) correlated with cortical T1 (r = 0.61), T1 CMD (r = 0.61), cortical (r = -0.45) and medullary ADC (r = -0.49), renal artery flow (r = -0.72) and cortical perfusion (r = -0.58). MRI measures (cortical T1 and ADC, T1 and ADC CMD, cortical perfusion) differed between low/high interstitial fibrosis groups at 30-40% fibrosis threshold. CONCLUSION: Comprehensive multi-parametric MRI is reproducible and correlates well with available measures of renal function and pathology. Larger longitudinal studies are warranted to evaluate its potential to stratify prognosis and response to therapy in CKD.


Assuntos
Testes de Função Renal/métodos , Rim/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Circulação Renal , Insuficiência Renal Crônica/patologia , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/metabolismo , Reprodutibilidade dos Testes
9.
MAGMA ; 33(1): 163-176, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31758418

RESUMO

To develop technical recommendations on the acquisition and post-processing of renal longitudinal (T1) and transverse (T2) relaxation time mapping. A multidisciplinary panel consisting of 18 experts in the field of renal T1 and T2 mapping participated in a consensus project, which was initiated by the European Cooperation in Science and Technology Action PARENCHIMA CA16103. Consensus recommendations were formulated using a two-step modified Delphi method. The first survey consisted of 56 items on T1 mapping, of which 4 reached the pre-defined consensus threshold of 75% or higher. The second survey was expanded to include both T1 and T2 mapping, and consisted of 54 items of which 32 reached consensus. Recommendations based were formulated on hardware, patient preparation, acquisition, analysis and reporting. Consensus-based technical recommendations for renal T1 and T2 mapping were formulated. However, there was considerable lack of consensus for renal T1 and particularly renal T2 mapping, to some extent surprising considering the long history of relaxometry in MRI, highlighting key knowledge gaps that require further work. This paper should be regarded as a first step in a long-term evidence-based iterative process towards ever increasing harmonization of scan protocols across sites, to ultimately facilitate clinical implementation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Pesquisa Translacional Biomédica/tendências , Consenso , Técnica Delphi , Humanos , Comunicação Interdisciplinar , Imageamento por Ressonância Magnética/instrumentação , Inquéritos e Questionários
10.
MAGMA ; 33(1): 141-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833014

RESUMO

OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.


Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído
11.
Am J Physiol Renal Physiol ; 316(4): F693-F702, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30648907

RESUMO

Noninvasive methods of magnetic resonance imaging (MRI) can quantify parameters of kidney function. The main purpose of this study was to determine baseline values of such parameters in healthy volunteers. In 28 healthy volunteers (15 women and 13 men), arterial spin labeling to estimate regional renal perfusion, blood oxygen level-dependent transverse relaxation rate (R2*) to estimate oxygenation, and apparent diffusion coefficient (ADC), true diffusion (D), and longitudinal relaxation time (T1) to estimate tissue properties were determined bilaterally in the cortex and outer and inner medulla. Additionally, phase-contrast MRI was applied in the renal arteries to quantify total renal blood flow. The results demonstrated profound gradients of perfusion, ADC, and D with highest values in the kidney cortex and a decrease towards the inner medulla. R2* and T1 were lowest in kidney cortex and increased towards the inner medulla. Total renal blood flow correlated with body surface area, body mass index, and renal volume. Similar patterns in all investigated parameters were observed in women and men. In conclusion, noninvasive MRI provides useful tools to evaluate intrarenal differences in blood flow, perfusion, diffusion, oxygenation, and structural properties of the kidney tissue. As such, this experimental approach has the potential to advance our present understanding regarding normal physiology and the pathological processes associated with acute and chronic kidney disease.


Assuntos
Rim/diagnóstico por imagem , Rim/fisiologia , Adulto , Índice de Massa Corporal , Superfície Corporal , Água Corporal/metabolismo , Feminino , Voluntários Saudáveis , Humanos , Rim/anatomia & histologia , Córtex Renal/metabolismo , Medula Renal/metabolismo , Imageamento por Ressonância Magnética , Masculino , Oxigênio/sangue , Circulação Renal , Adulto Jovem
12.
J Magn Reson Imaging ; 49(6): 1577-1586, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30353969

RESUMO

BACKGROUND: Noninvasive assessment of dynamic changes in liver blood flow, perfusion, and oxygenation using MRI may allow detection of subtle hemodynamic alterations in cirrhosis. PURPOSE: To assess the feasibility of measuring dynamic liver blood flow, perfusion, and T2 * alterations in response to meal, hypercapnia, and hyperoxia challenges. STUDY TYPE: Prospective. SUBJECTS: Ten healthy volunteers (HV) and 10 patients with compensated cirrhosis (CC). FIELD STRENGTH/SEQUENCE: 3T; phase contrast, arterial spin labeling, and T2* mapping. ASSESSMENT: Dynamic changes in portal vein and hepatic artery blood flow (using phase contrast MRI), liver perfusion (using arterial spin labeling), and blood oxygenation ( T2* mapping) following a meal challenge (660 kcal), hyperoxia (target PET O2 of 500 mmHg), and hypercapnia (target increase PET CO2 of ∼6 mmHg). STATISTICAL TESTS: Tests between baseline and each challenge were performed using a paired two-tailed t-test (parametric) or Wilcoxon-signed-ranks test (nonparametric). Repeatability and reproducibility were determined by the coefficient of variation (CoV). RESULTS: Portal vein velocity increased following the meal (70 ± 9%, P < 0.001) and hypercapnic (7 (5-11)%, P = 0.029) challenge, while hepatic artery flow decreased (-30 ± 18%, P = 0.005) following the meal challenge in HV. In CC patients, portal vein velocity increased (37 ± 13%, P = 0.012) without the decrease in hepatic artery flow following the meal. In both groups, the meal increased liver perfusion (HV: 82 ± 50%, P < 0.0001; CC: 27 (16-42)%, P = 0.011) with faster arrival time of blood (HV: -54 (-56-30)%, P = 0.074; CC: -42 ± 32%, P = 0.005). In HVs, T2* increased after the meal and in response to hyperoxia, with a decrease in hypercapnia (6 ± 8% P = 0.052; 3 ± 5%, P = 0.075; -5 ± 6%, P = 0.073, respectively), but no change in CC patients. Baseline between-session CoV <15% for blood flow and <10% for T2* measures. DATA CONCLUSION: Dynamic changes in liver perfusion, blood flow, and oxygenation following a meal, hyperoxic, and hypercapnic challenges can be measured using noninvasive MRI and potentially be used to stratify patients with cirrhosis. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:1577-1586.


Assuntos
Alimentos , Hipercapnia/diagnóstico por imagem , Hiperóxia/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Idoso , Artérias/diagnóstico por imagem , Feminino , Fibrose/diagnóstico por imagem , Voluntários Saudáveis , Hemodinâmica , Artéria Hepática/diagnóstico por imagem , Humanos , Hipercapnia/metabolismo , Hiperóxia/metabolismo , Masculino , Microscopia de Contraste de Fase , Pessoa de Meia-Idade , Oxigênio/metabolismo , Perfusão , Veia Porta/diagnóstico por imagem , Período Pós-Prandial , Estudos Prospectivos , Reprodutibilidade dos Testes , Marcadores de Spin , Adulto Jovem
13.
J Hepatol ; 69(5): 1015-1024, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29886155

RESUMO

BACKGROUND & AIMS: Advancing liver disease results in deleterious changes in a number of critical organs. The ability to measure structure, blood flow and tissue perfusion within multiple organs in a single scan has implications for determining the balance of benefit vs. harm for therapies. Our aim was to establish the feasibility of magnetic resonance imaging (MRI) to assess changes in Compensated Cirrhosis (CC), and relate this to disease severity and future liver-related outcomes (LROs). METHODS: A total of 60 patients with CC, 40 healthy volunteers and 7 patients with decompensated cirrhosis were recruited. In a single scan session, MRI measures comprised phase-contrast MRI vessel blood flow, arterial spin labelling tissue perfusion, T1 longitudinal relaxation time, heart rate, cardiac index, and volume assessment of the liver, spleen and kidneys. We explored the association between MRI parameters and disease severity, analysing differences in baseline MRI parameters in the 11 (18%) patients with CC who experienced future LROs. RESULTS: In the liver, compositional changes were reflected by increased T1 in progressive disease (p <0.001) and an increase in liver volume in CC (p = 0.006), with associated progressive reduction in liver (p <0.001) and splenic (p <0.001) perfusion. A significant reduction in renal cortex T1 and increase in cardiac index and superior mesenteric arterial blood flow was seen with increasing disease severity. Baseline liver T1 (p = 0.01), liver perfusion (p <0.01), and renal cortex T1 (p <0.01) were significantly different in patients with CC who subsequently developed negative LROs. CONCLUSIONS: MRI enables the contemporaneous assessment of organs in liver cirrhosis in a single scan without the requirement for a contrast agent. MRI parameters of liver T1, renal T1, hepatic and splenic perfusion, and superior mesenteric arterial blood flow were related to the risk of LROs. LAY SUMMARY: This study assesses the changes to structure, blood flow and perfusion that occur in the key organs (liver, spleen and kidney) associated with severe liver disease (Compensated Cirrhosis), using magnetic resonance imaging. The magnetic resonance imaging measures which changed with disease severity and were related to negative liver-related clinical outcomes are described.


Assuntos
Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Feminino , Humanos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Índice de Gravidade de Doença , Baço/diagnóstico por imagem
14.
J Am Soc Nephrol ; 28(4): 1269-1277, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28122851

RESUMO

Hemodynamic stress during hemodialysis (HD) results in recurrent segmental ischemic injury (myocardial stunning) that drives cumulative cardiac damage. We performed a fully comprehensive study of the cardiovascular effect of dialysis sessions using intradialytic cardiac magnetic resonance imaging (MRI) to examine the comparative acute effects of standard HD versus hemodiafiltration (HDF) in stable patients. We randomly allocated 12 patients on HD (ages 32-72 years old) to either HD or HDF. Patients were stabilized on a modality for 2 weeks before undergoing serial cardiac MRI assessment during dialysis. Patients then crossed over to the other modality and were rescanned after 2 weeks. Cardiac MRI measurements included cardiac index, stroke volume index, global and regional contractile function (myocardial strain), coronary artery flow, and myocardial perfusion. Patients had mean±SEM ultrafiltration rates of 3.8±2.9 ml/kg per hour during HD and 4.4±2.5 ml/kg per hour during HDF (P=0.29), and both modalities provided a similar degree of cooling. All measures of systolic contractile function fell during HD and HDF, with partial recovery after dialysis. All patients experienced some degree of segmental left ventricular dysfunction, with severity proportional to ultrafiltration rate and BP reduction. Myocardial perfusion decreased significantly during HD and HDF. Treatment modality did not influence any of the cardiovascular responses to dialysis. In conclusion, in this randomized, crossover study, there was no significant difference in the cardiovascular response to HDF or HD with cooled dialysate as assessed with intradialytic MRI.


Assuntos
Sistema Cardiovascular/diagnóstico por imagem , Sistema Cardiovascular/fisiopatologia , Imageamento por Ressonância Magnética , Diálise Renal , Estudos Cross-Over , Feminino , Hemodiafiltração , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
15.
Am J Gastroenterol ; 112(2): 346-355, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27958282

RESUMO

OBJECTIVES: Non-invasive biomarkers which identify different mechanisms of disease in subgroups of irritable bowel syndrome (IBS) could be valuable. Our aim was to seek useful magnetic resonance imaging (MRI) parameters that could distinguish each IBS subtypes. METHODS: 34 healthy volunteers (HV), 30 IBS with diarrhea (IBS-D), 16 IBS with constipation (IBS-C), and 11 IBS with mixed bowel habit (IBS-M) underwent whole-gut transit and small and large bowel volumes assessment with MRI scans from t=0 to t=360 min. Since the bowel frequency for IBS-M were similar to IBS-D, IBS-M and IBS-D were grouped together and labeled as IBS non-constipation group (IBS-nonC). RESULTS: Median (interquartile range): fasting small bowel water content in IBS-nonC was 21 (10-42), significantly less than HV at 44 ml (15-70), P<0.01 as was the postprandial area under the curve (AUC) P<0.01. The fasting transverse colon volumes in IBS-C were significantly larger at 253 (200-329) compared with HV, IBS-nonC whose values were 165 (117-255) and 198 (106-270) ml, respectively, P=0.02. Whole-gut transit time for IBS-C was prolonged at 69 (51-111), compared with HV at 34 (4-63) and IBS-D at 34 (17-78) h, P=0.03. Bloating score (VAS 0-10 cm) correlated with transverse colon volume at t=405 min, Spearman r=0.21, P=0.04. CONCLUSIONS: The constricted small bowel in IBS-nonC and the dilated transverse colon in IBS-C point to significant differences in underlying mechanisms of disease.


Assuntos
Colo/diagnóstico por imagem , Constipação Intestinal/diagnóstico por imagem , Diarreia/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Síndrome do Intestino Irritável/diagnóstico por imagem , Adolescente , Adulto , Idoso , Área Sob a Curva , Estudos de Casos e Controles , Colo/patologia , Colo/fisiopatologia , Constipação Intestinal/classificação , Constipação Intestinal/etiologia , Constipação Intestinal/fisiopatologia , Diarreia/classificação , Diarreia/etiologia , Diarreia/fisiopatologia , Jejum , Feminino , Trânsito Gastrointestinal/fisiologia , Humanos , Intestino Delgado/patologia , Intestino Delgado/fisiopatologia , Síndrome do Intestino Irritável/classificação , Síndrome do Intestino Irritável/complicações , Síndrome do Intestino Irritável/fisiopatologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Período Pós-Prandial , Índice de Gravidade de Doença , Adulto Jovem
16.
J Hepatol ; 65(6): 1131-1139, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27475617

RESUMO

BACKGROUND & AIMS: Hepatic venous pressure gradient (HVPG) measurement is currently the only validated technique to accurately evaluate changes in portal pressure. In this study, we evaluate the use of non-contrast quantitative magnetic resonance imaging (MRI) as a surrogate measure of portal pressure. METHODS: Thirty patients undergoing HVPG measurement were prospectively recruited. MR parameters of longitudinal relaxation time (T1), perfusion of the liver and spleen (by arterial spin labelling), and blood flow in the portal, splanchnic and collateral circulation (by phase contrast MRI) were assessed. We estimated the liver stiffness measurement (LSM) and enhanced liver fibrosis (ELF) score. The correlation of all non-invasive parameters with HVPG was evaluated. RESULTS: The mean (range) HVPG of the patients was 9.8 (1-22) mmHg, and 14 patients (48%) had clinically significant portal hypertension (CSPH, HVPG ⩾10mmHg). Liver T1 relaxation time, splenic artery and superior mesenteric artery velocity correlated significantly with HVPG. Using multiple linear regression, liver T1 and splenic artery velocity remained as the two parameters in the multivariate model significantly associated with HVPG (R=0.90, p<0.001). This correlation was maintained in patients with CSPH (R=0.85, p<0.001). A validation cohort (n=10) showed this linear model provided a good prediction of HVPG. LSM and ELF score correlated significantly with HVPG in the whole population but the correlation was absent in CSPH. CONCLUSIONS: MR parameters related to both hepatic architecture and splanchnic haemodynamics correlate significantly with HVPG. This proposed model, confirmed in a validation cohort, could replace the invasive HVPG measurement. LAY SUMMARY: In patients with cirrhosis, the development and progression of portal hypertension is related to worse outcomes. However, the standard technique of assessing portal pressure is invasive and not widely used in clinical practice. Here, we have studied the use of non-invasive MRI in evaluating portal pressure. The MRI measures of liver architecture and blood flow in the splenic artery correlated well with portal pressure. Therefore, this non-invasive method can potentially be used to assess portal pressure in clinical trials and monitoring treatment in practice.


Assuntos
Hipertensão Portal , Humanos , Cirrose Hepática , Imageamento por Ressonância Magnética , Pressão na Veia Porta
17.
J Nutr ; 145(6): 1170-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25926408

RESUMO

BACKGROUND: Intragastric creaming and droplet size of fat emulsions may affect intragastric behavior and gastrointestinal and satiety responses. OBJECTIVES: We tested the hypotheses that gastrointestinal physiologic responses and satiety will be increased by an increase in intragastric stability and by a decrease in fat droplet size of a fat emulsion. METHODS: This was a double-blind, randomized crossover study in 11 healthy persons [8 men and 3 women, aged 24 ± 1 y; body mass index (in kg/m(2)): 24.4 ± 0.9] who consumed meals containing 300-g 20% oil and water emulsion (2220 kJ) with 1) larger, 6-µm mean droplet size (Coarse treatment) expected to cream in the stomach; 2) larger, 6-µm mean droplet size with 0.5% locust bean gum (LBG; Coarse+LBG treatment) to prevent creaming; or 3) smaller, 0.4-µm mean droplet size with LBG (Fine+LBG treatment). The participants were imaged hourly by using MRI and food intake was assessed by using a meal that participants consumed ad libitum. RESULTS: The Coarse+LBG treatment (preventing creaming in the stomach) slowed gastric emptying, resulting in 12% higher gastric volume over time (P < 0.001), increased small bowel water content (SBWC) by 11% (P < 0.01), slowed appearance of the (13)C label in the breath by 17% (P < 0.01), and reduced food intake by 9% (P < 0.05) compared with the Coarse treatment. The Fine+LBG treatment (smaller droplet size) slowed gastric emptying, resulting in 18% higher gastric volume (P < 0.001), increased SBWC content by 15% (P < 0.01), and significantly reduced food intake by 11% (P < 0.05, equivalent to an average of 411 kJ less energy consumed) compared with the Coarse+LBG treatment. These high-fat meals stimulated substantial increases in SBWC, which increased to a peak at 4 h at 568 mL (range: 150-854 mL; P < 0.01) for the Fine+LBG treatment. CONCLUSION: Manipulating intragastric stability and fat emulsion droplet size can influence human gastrointestinal physiology and food intake.


Assuntos
Gorduras na Dieta/administração & dosagem , Gorduras na Dieta/farmacocinética , Trato Gastrointestinal/metabolismo , Saciação/fisiologia , Adulto , Índice de Massa Corporal , Estudos Cross-Over , Digestão , Método Duplo-Cego , Emulsões/química , Ingestão de Energia , Feminino , Esvaziamento Gástrico/fisiologia , Conteúdo Gastrointestinal/química , Voluntários Saudáveis , Humanos , Imageamento por Ressonância Magnética , Masculino , Refeições , Tamanho da Partícula , Período Pós-Prandial/fisiologia , Resposta de Saciedade/fisiologia , Adulto Jovem
18.
J Magn Reson Imaging ; 42(5): 1233-40, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25787269

RESUMO

PURPOSE: To dynamically quantify pancreatic perfusion and flow within the arteries supplying the pancreas in response to secretin stimulation. MATERIALS AND METHODS: Twelve healthy male subjects were scanned at 1.5T with arterial spin labeling to measure tissue perfusion and phase contrast magnetic resonance imaging (MRI) to measure vessel flow. Superior mesenteric (SMA), gastroduodenal (GDA), common hepatic (HA), and splenic (SA) arterial flow and pancreatic perfusion were serially measured for 50 minutes following 1 IU/kg intravenous secretin. The significance of differences between timepoints was tested using a repeated measures one-way analysis of variance (ANOVA). RESULTS: Baseline blood flow (mean ± SEM or median [IQR]) for SMA, HA, SA, and GDA was 7.6 ± 1.3, 4.0 ± 0.5, 8.2 ± 0.8, and 0.9 (0.8-1.4) ml/s, respectively. Baseline pancreatic perfusion was 200 ± 25 ml/100g/min. Blood flow increased in the SMA (234%, P < 0.0001) and GDA (155%, P = 0.015) immediately after secretin injection. Reduced HA blood flow was observed after 10 minutes (P = 0.066) with no change in SA flow (P = 0.533). Increased pancreatic perfusion was maintained for 40 minutes after injection with a maximal increase at 5 minutes (16.8%, P = 0.025). CONCLUSION: Intravenous secretin resulted in significant temporal changes in pancreatic perfusion and arterial blood flow.


Assuntos
Imageamento por Ressonância Magnética , Pâncreas/irrigação sanguínea , Secretina/administração & dosagem , Adulto , Análise de Variância , Meios de Contraste , Fármacos Gastrointestinais/administração & dosagem , Humanos , Aumento da Imagem , Masculino , Pâncreas/efeitos dos fármacos , Pâncreas/fisiologia , Fluxo Sanguíneo Regional/fisiologia , Marcadores de Spin , Tempo , Adulto Jovem
19.
Eur Radiol ; 25(6): 1684-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25577519

RESUMO

OBJECTIVE: To study the association of renal function with renal perfusion and renal parenchymal structure (T1 relaxation) in patients with chronic heart failure (HF). METHODS: After IRB approval, 40 participants were enrolled according to HF and renal function status [10 healthy volunteers < 40 years; 10 healthy age-matched volunteers; 10 HF patients eGFR > 60 ml/min/1.73 m(2); 10 HF patients eGFR < 60 ml/min/1.73 m(2)] and assessed by MRI. To be eligible for enrolment all HF patients with renal dysfunction (RD) needed to be diagnosed as having chronic cardiorenal syndrome based on current guidelines. Patients with primary kidney disease were excluded. RESULTS: Renal cortical perfusion correlated with eGFR values (r = 0.52;p < 0.01) and was similar between HF patients with and without RD (p = 0.27). T1 relaxation correlated negatively with eGFR values (r = -0.41;p > 0.01) and was higher in HF patients compared to volunteers (1121 ± 102 ms vs. 1054 ± 65 ms;p = 0.03). T1 relaxation was selectively prolonged in HF patients with RD (1169 ms ± 100 vs. HF without RD 1067 ms ± 79;p = 0.047). In linear regression analyses coronary artery disease (p = 0.01), hypertension (p = 0.04), and diabetes mellitus (p < 0.01) were associated with T1 relaxation. CONCLUSION: RD in HF is not primarily mediated by decreased renal perfusion. Instead, chronic reno-parenchymal damage, as indicated by prolonged T1 relaxation, appears to underly chronic cardiorenal syndrome. KEY POINTS: • The pathophysiology underlying chronic cardiorenal syndrome is not completely understood. • Chronic cardiorenal syndrome is independent of cardiac output or renal perfusion. • Renal T 1 relaxation appears to be prolonged in HF with renal impairment. • Renal T 1 relaxation is associated with classic cardiovascular risk factors. • Association of renal T 1 relaxation with parenchymal damage should be validated further.


Assuntos
Síndrome Cardiorrenal/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Doenças Cardiovasculares/complicações , Doença Crônica , Feminino , Humanos , Rim/fisiopatologia , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Insuficiência Renal/fisiopatologia , Fatores de Risco
20.
Ann Surg ; 259(5): 881-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24253140

RESUMO

OBJECTIVE: We compared the effects of intravenous administration of 6% hydroxyethyl starch (maize-derived) in 0.9% saline (Voluven; Fresenius Kabi, Runcorn, United Kingdom) and a "balanced" preparation of 6% hydroxyethyl starch (potato-derived) [Plasma Volume Redibag (PVR); Baxter Healthcare, Thetford, United Kingdom] on renal blood flow velocity and renal cortical tissue perfusion in humans using magnetic resonance imaging. BACKGROUND: Hyperchloremia resulting from 0.9% saline infusion may adversely affect renal hemodynamics when compared with balanced crystalloids. This phenomenon has not been studied with colloids. METHODS: Twelve healthy adult male subjects received 1-L intravenous infusions of Voluven or PVR over 30 minutes in a randomized, double-blind manner, with crossover studies 7 to 10 days later. Magnetic resonance imaging proceeded for 60 minutes after commencement of infusion to measure renal artery blood flow velocity and renal cortical perfusion. Blood was sampled, and weight was recorded at 0, 30, 60, 120, 180, and 240 minutes. RESULTS: Mean peak serum chloride concentrations were 108 and 106 mmol/L, respectively, after Voluven and PVR infusion (P = 0.032). Changes in blood volume (P = 0.867), strong ion difference (P = 0.219), and mean renal artery flow velocity (P = 0.319) were similar. However, there was a significant increase in mean renal cortical tissue perfusion after PVR when compared with Voluven (P = 0.033). There was no difference in urinary neutrophil gelatinase-associated liopcalin to creatinine ratios after the infusion (P = 0.164). CONCLUSIONS: There was no difference in the blood volume-expanding properties of the 2 preparations of 6% hydroxyethyl starch. The balanced starch produced an increase in renal cortical tissue perfusion, a phenomenon not seen with starch in 0.9% saline.


Assuntos
Acetatos/administração & dosagem , Volume Sanguíneo/fisiologia , Derivados de Hidroxietil Amido/administração & dosagem , Córtex Renal/fisiologia , Minerais/administração & dosagem , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Cloreto de Sódio/administração & dosagem , Estudos Cross-Over , Relação Dose-Resposta a Droga , Método Duplo-Cego , Combinação de Medicamentos , Seguimentos , Voluntários Saudáveis , Humanos , Infusões Intravenosas , Imageamento por Ressonância Magnética/métodos , Masculino , Substitutos do Plasma/administração & dosagem , Fluxo Sanguíneo Regional/fisiologia , Artéria Renal/efeitos dos fármacos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA