Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med ; 32(12): 1745-1752, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27692753

RESUMO

Peptide receptor therapy with 177Lu-labelled somatostatin analogues is a promising tool in the management of patients with inoperable or metastasized neuroendocrine tumours. The aim of this work was to perform accurate activity quantification of 177Lu in complex anthropomorphic geometry using advanced correction algorithms. Acquisitions were performed on the higher 177Lu photopeak (208keV) using a Philips IRIX gamma camera provided with medium-energy collimators. System calibration was performed using a 16mL Jaszczak sphere surrounded by non-radioactive water. Attenuation correction was performed using µ-maps derived from CT data, while scatter and septal penetration corrections were performed using the transmission-dependent convolution-subtraction method. SPECT acquisitions were finally corrected for dead time and partial volume effects. Image analysis was performed using the commercial QSPECT software. The quantitative SPECT approach was validated on an anthropomorphic phantom provided with a home-made insert simulating a hepatic lesion. Quantitative accuracy was studied using three tumour-to-background activity concentration ratios (6:1, 9:1, 14:1). For all acquisitions, the recovered total activity was within 12% of the calibrated activity both in the background region and in the tumour. Using a 6:1 tumour-to-background ratio the recovered total activity was within 2% in the tumour and within 5% in the background. Partial volume effects, if not properly accounted for, can lead to significant activity underestimations in clinical conditions. In conclusion, accurate activity quantification of 177Lu can be obtained if activity measurements are performed with equipment traceable to primary standards, advanced correction algorithms are used and acquisitions are performed at the 208keV photopeak using medium-energy collimators.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Lutécio , Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído , Técnica de Subtração
2.
Appl Radiat Isot ; 112: 156-64, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27064195

RESUMO

Over the last years (177)Lu has received considerable attention from the clinical nuclear medicine community thanks to its wide range of applications in molecular radiotherapy, especially in peptide-receptor radionuclide therapy (PRRT). In addition to short-range beta particles, (177)Lu emits low energy gamma radiation of 113keV and 208keV that allows gamma camera quantitative imaging. Despite quantitative cancer imaging in molecular radiotherapy having been proven to be a key instrument for the assessment of therapeutic response, at present no general clinically accepted quantitative imaging protocol exists and absolute quantification studies are usually based on individual initiatives. The aim of this work was to develop and evaluate an approach to gamma camera calibration for absolute quantification in tomographic imaging with (177)Lu. We assessed the gamma camera calibration factors for a Philips IRIX and Philips AXIS gamma camera system using various reference geometries, both in air and in water. Images were corrected for the major effects that contribute to image degradation, i.e. attenuation, scatter and dead- time. We validated our method in non-reference geometry using an anthropomorphic torso phantom provided with the liver cavity uniformly filled with (177)LuCl3. Our results showed that calibration factors depend on the particular reference condition. In general, acquisitions performed with the IRIX gamma camera provided good results at 208keV, with agreement within 5% for all geometries. The use of a Jaszczak 16mL hollow sphere in water provided calibration factors capable of recovering the activity in anthropomorphic geometry within 1% for the 208keV peak, for both gamma cameras. The point source provided the poorest results, most likely because scatter and attenuation correction are not incorporated in the calibration factor. However, for both gamma cameras all geometries provided calibration factors capable of recovering the activity in anthropomorphic geometry within about 10% (range -11.6% to +7.3%) for acquisitions at the 208keV photopeak. As a general rule, scatter and attenuation play a much larger role at 113keV compared to 208keV and are likely to hinder an accurate absolute quantification. Acquisitions of only the (177)Lu main photopeak (208keV) are therefore recommended in clinical practice. Preliminary results suggest that the gamma camera calibration factor can be assessed with a standard uncertainty below (or of the order of) 3% if activity is determined with equipment traceable to primary standards, accurate volume measurements are made, and an appropriate chemical carrier is used to allow a homogeneous and stable solution to be used during the measurements.


Assuntos
Câmaras gama , Lutécio , Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Calibragem , Câmaras gama/estatística & dados numéricos , Humanos , Interpretação de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
3.
Appl Radiat Isot ; 81: 255-60, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23582494

RESUMO

In 2011 the joint research project Metrology for Radioactive Waste Management (MetroRWM)(1) of the European Metrology Research Programme (EMRP) started with a total duration of three years. Within this project, new metrological resources for the assessment of radioactive waste, including their calibration with new reference materials traceable to national standards will be developed. This paper gives a review on national, European and international strategies as basis for science-based metrological requirements in clearance and acceptance of radioactive waste.


Assuntos
Guias como Assunto , Proteção Radiológica/legislação & jurisprudência , Proteção Radiológica/normas , Resíduos Radioativos/legislação & jurisprudência , Resíduos Radioativos/prevenção & controle , Gerenciamento de Resíduos/legislação & jurisprudência , Gerenciamento de Resíduos/normas , Descontaminação/legislação & jurisprudência , Descontaminação/normas , Internacionalidade
4.
Appl Radiat Isot ; 70(9): 2075-80, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22464789

RESUMO

A (177)Lu primary standard was developed at the ENEA-INMRI in the frame of an international comparison organized by BIPM and piloted by NIST (USA). The CIEMAT/NIST method with (3)H standard source as tracer was used for standardizing a solution of (177)Lu. The activity value was compared also with the measurements of the same mother solution carried out by the 4πγ integral counting method. Particular efforts were made to identify and quantify the long-lived (177m)Lu impurity in the mother solution. The results obtained by the two methods are in good agreement within their standard uncertainties. The arithmetic mean of the two values is in good agreement with the Comparison Reference Value (CRV). By the new primary standard two well-type ionization chambers (ICs), one fixed and the other one portable, were calibrated with an uncertainty lower than 2%. These ICs are used for routinely applications in the activity measurements of short-lived radionuclides particularly useful for medical applications.


Assuntos
Lutécio/análise , Lutécio/normas , Radioisótopos/análise , Radioisótopos/normas , Radiometria/normas , Meia-Vida , Internacionalidade , Doses de Radiação , Padrões de Referência , Valores de Referência
5.
Appl Radiat Isot ; 70(9): 2119-23, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22476014

RESUMO

The effect of radon diffusion and distribution between a (226)Ra matrix and the top air gap inside sample containers for gamma-ray spectrometry was studied. Containers filled at almost 100% or just 70% of total capacity yielded correction factors of about 7% and 20% respectively. Applying these correction factors allowed activity values calculated from (226)Ra or radon decay products to agree within 2%.


Assuntos
Algoritmos , Artefatos , Radiometria/normas , Radônio/análise , Radônio/normas , Espectrometria gama/métodos , Espectrometria gama/normas , Ar , Meia-Vida , Internacionalidade , Transição de Fase , Doses de Radiação , Radiometria/métodos , Radônio/química , Padrões de Referência , Valores de Referência , Soluções
6.
Appl Radiat Isot ; 70(9): 1825-30, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22445396

RESUMO

An international Key Comparison of (177)Lu has recently been carried out. Twelve laboratories performed assays for radioactivity content on aliquots of a common master solution of (177)Lu, leading to eleven results submitted for entry into the Key Comparison Database of the Mutual Recognition Arrangement. A proposed Comparison Reference Value (CRV) was calculated to be 3.288(4)MBq/g using all eleven results. Degrees of equivalence and their uncertainties were calculated for each laboratory based on the CRV. Most of the values reported by the participating laboratories were within 0.6% of the CRV.


Assuntos
Lutécio/análise , Lutécio/química , Radioisótopos/análise , Radioisótopos/química , Radiometria/instrumentação , Radiometria/normas , Lutécio/normas , Doses de Radiação , Radioisótopos/normas , Padrões de Referência , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA