Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39041319

RESUMO

OBJECTIVE: To assess the relative position of mini-implants to retain a mandibular overdenture, according to the surgical protocol, technical and anatomical factors. METHODS: Mandibular cone-beam computed tomography (CBCT) scans were analyzed for 73 patients who received four one-piece titanium-zirconium mini-implants. Drilling was performed using a 1.6 mm needle drill and a 2.2 mm Pilot Drill, according to the bone density with a surgical stent. Post-insertion CBCT images in DICOM format were analyzed using the E-Vol-DX software with BAR filters. Divergence angle between implants and between implants and the overdenture path of insertion was measured using CliniView 10.2.6 software. RESULTS: Divergence between implants ranged from 0° to 22.3° (mean = 4.2; SD = 3.7) in the lateral and from 0° to 26.2° (mean = 5.3; SD = 4.1) in the frontal projections (p < .001). Only 1 (0.2%) and 3 (0.7%) of the measurements were higher than 20° in the lateral and frontal views, respectively. The mean angulations between the implant and the path of insertion for the overdenture were 9.3° (SD = 7.5) and 4.0° (SD = 2.9) for the lateral and frontal views, respectively (p < .001). Regression analyses showed a significant association between the divergence of implants and the frontal view projection (p < .001), greater distance between the paired implants (p = .017), the flapped surgical protocol (p = .002), higher final insertion torque (p = .011), and deeper preparation with the needle drill (p < .001). CONCLUSIONS: The mini-implants were placed with low divergence angles and satisfactory parallelism. Factors including shorter distances between the implants, higher density bone, and a flapless surgical approach all contributed positively to improved parallelism of the mini-implants.

2.
Clin Oral Investig ; 28(6): 330, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38772987

RESUMO

OBJECTIVES: The aim of this multi-center pilot study was to assess the viability and feasibility of a novel treatment concept - the canine-positioned single implant mandibular overdenture (c-SIMO), with the single implant placed on the patient's preferred chewing side instead of the midline. MATERIALS AND METHODS: Participants received a single implant in the canine region of their preferred chewing side, based on an Asymmetry Index observed during mastication. The pre-existing mandibular denture was transformed into a c-SIMO on a spherical attachment. The primary outcome was oral health-related quality of life (OHRQoL), measured with GOHAI and OHIP-EDENT. Secondary outcomes included denture satisfaction index (DSI), chewing efficiency (CE), maximum bite force (MBF), implant survival and success, and prosthetic maintenance. Data analysis included descriptive statistics and bivariate comparison tests. RESULTS: Fifteen participants received the c-SIMO treatment (mean age: 69.9 ± 7.0). Implant success and survival rates were 100% at 1 year. Patient-reported outcome measures improved significantly compared to pre-treatment values (OHIP-EDENT: p = 0.001; DSI: p = 0.001; GOHAI: p = 0.002). Masticatory outcomes also improved significantly (CE: p = 0.001; overall MBF: p = 0.005). Post-implant, MBF was significantly higher in the ipsilateral side compared to the contralateral side at 2 weeks (p = 0.019) and 3 months (p = 0.015), but no longer at T3 (p = 0.730). Common prosthodontic events included denture base adjustments (n = 17) and matrix activation (n = 9). CONCLUSIONS: This pilot study concludes that c-SIMO is a promising treatment option, and a potential alternative to the single midline implant overdenture. CLINICAL RELEVANCE: The novel treatment concept of a canine-positioned single implant mandibular overdenture could be a viable treatment alternative to the midline positioning.


Assuntos
Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Estudos de Viabilidade , Mastigação , Qualidade de Vida , Humanos , Projetos Piloto , Idoso , Masculino , Feminino , Mastigação/fisiologia , Dente Canino , Implantes Dentários para Um Único Dente , Satisfação do Paciente , Pessoa de Meia-Idade , Mandíbula , Planejamento de Dentadura
3.
J Oral Rehabil ; 51(8): 1459-1467, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38685704

RESUMO

OBJECTIVE: This prospective study is part of a randomised clinical trial and reports the changes in masticatory performance (MP) and bite force, and explores their influential factors, 1 year after the provision of mandibular overdentures retained by four titanium-zirconium mini implants. METHODS: Edentulous patients received conventional complete dentures, followed by placement of four mini implants (Straumann® Mini Implant System) in the anterior mandible and converting the conventional prosthesis into a mandibular overdenture. Treatment protocols were randomised using a 2×2 factorial design combining different surgical (flapped vs. flapless) and loading (immediate vs. delayed) protocols. MP was assessed using a two-colour mixing ability test and a colorimetric analysis to measure the level of colour mixing (Variance of Hue-VoH). Maximum voluntary bite force (MBF) was measured by a digital gnathodynamometer in the posterior and anterior regions. Sex, age, surgical and loading protocols and ridge morphology were tested as independent variables. MP and MBF tests were performed at baseline (pre-treatment) and the 3-, 6- and 12-month after implant loading. Descriptive statistics, independent t-test, and linear mixed-effect model (LMM) regression were used for data analysis. RESULTS: Seventy-four participants were assessed and 73 completed the 1-year follow-up. Statistically significant improvements in functional parameters were observed in all follow-up periods compared to baseline (p < .001). The flapless protocol was associated with higher improvement in MP at the 3-month follow-up (p = .004), while less resorbed ridges were associated with better MP (p = .038) and higher MBF (p < .001). CONCLUSION: The mandibular overdenture protocol using four titanium-zirconium mini implants was effective in improving MP and MBF of edentulous patients, compared to pre-treatment values. The findings also suggest that improvements in chewing function and bite force are impacted by clinical factors since better outcomes were observed for flapless surgeries and less resorbed edentulous ridges. CLINICAL TRIAL REGISTRATION: ClinicalTrials.Gov ID NCT04760457.


Assuntos
Força de Mordida , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Mandíbula , Mastigação , Titânio , Zircônio , Humanos , Masculino , Feminino , Mastigação/fisiologia , Estudos Prospectivos , Idoso , Mandíbula/cirurgia , Pessoa de Meia-Idade , Implantes Dentários , Resultado do Tratamento , Retenção de Dentadura/métodos , Prótese Total Inferior , Arcada Edêntula/reabilitação , Arcada Edêntula/cirurgia
4.
J Prosthodont ; 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38512962

RESUMO

This report of four clinical cases aims to illustrate the use of a lateral implant as a solution for implant overdentures in the mandible in different clinical situations. The first two cases describe the clinical situations of patients wearing two-implant mandibular overdentures until the failure of one of the implants, one due to implant loss and the other due to a fracture of an abutment screw, and how the conditions were managed. The third case illustrates the placement of a single implant to retain an overdenture, where a midline implant, as originally planned, was not feasible due to anatomic reasons. The final case describes the use of a lateral implant to support and retain a single-implant mandibular overdenture. The four cases demonstrate that a single lateral implant can be utilized as sole retention in cases of a failing contra-lateral implant and as an alternative to a single implant in the midline.

5.
J Dent ; 149: 105266, 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39067651

RESUMO

OBJECTIVE: This 2-year prospective study reports the incidence of prosthetic complications and maintenance events after treatment with mandibular overdenture retained by four mini implants opposed to a maxillary denture. METHODS: Implant intervention included flapless or flapped surgery combined with immediate or delayed loading, as part of a randomized clinical trial. Four one-piece titanium-zirconium mini-implants (Straumann Mini Implant System) were inserted, and the retentive PEEK elements (Optiloc) were incorporated into the overdenture using chairside procedures. Prosthodontic complications and maintenance events were recorded over a 2-year follow-up, and the final outcome was defined according to standardized criteria. Data analysis included descriptive statistics, incidence and incidence density rates, and Kaplan-Meier survival. RESULTS: 73 out of 74 patients (64.9 % female), mean age of 64 (SD=8.2) years, completed the study follow-up (one withdrew after 9 months). Implant survival was 100 %. A total of 163 prosthodontic events occurred in 53 patients (72.6 %), and 20 patients had no clinical complaints or maintenance needs. The most common procedures were adjustment/repair of the overdenture base (47.0 %), replacement of retentive inserts (19.8 %), and laboratory relining (12.9 %). A high prosthodontic success rate was achieved (93.2 %), and all patients presented serviceable overdentures and continuous use after the resolution of prosthodontic complications. The incidences of matrix replacement and laboratory relines were low in the first year, while denture base adjustments were common within the first year, especially in the first 6 months. CONCLUSION: The mini implant system showed high prosthodontic success rates. Minor adjustments/repairs during the initial follow-up were common. Relines and matrix replacements tend to occur after one year of overdenture use, and matrix replacements may occur as a consequence of the need for relining.

6.
J Dent ; 149: 105267, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39067647

RESUMO

AIM: The positive impact of implant interventions on dental patient-reported outcomes is an essential parameter of treatment effectiveness. This study assessed the 2-year changes in patient satisfaction and oral health-related quality of life (OHRQoL) of edentulous patients treated with a four mini implant mandibular overdenture (IOD) METHODS: The study was planned as a 2 × 2 factorial randomized clinical trial that tested two surgical approaches (flapped or flapless) and two loading protocols (immediate and delayed) using a titanium-zirconium mini implant (Straumann Mini Implant System®) and a PEEK retentive system (Straumann® Optiloc® Retentive System). Outcome measures (OHIP-Edent scores and the McGill Denture Satisfaction questionnaire) were assessed before treatment and at the 3-, 6-, 12-, and 24-month follow-ups. The Friedman test and multiple regression using Generalized Estimating Equations (GEE) were used for data analysis, considering the per-protocol (PP) and intention-to-treat (ITT) approaches RESULTS: Seventy-four patients were randomized to the study groups. No implant failure occurred during the study period. Marked improvement in all post-treatment periods compared to baseline were observed for the two outcomes. No significant effect of patient's gender, age, and surgical protocol on the study outcomes. The effect of treatment provision was significant for the two outcomes in the PP and ITT approaches (p < 0.001). A barely significant positive effect of the immediate loading was observed for OHIP-Edent in the PP approach (p = 0.020) CONCLUSION: IOD treatment significantly improved patient-reported outcomes measures, with sustained benefits over the two years of overdenture use, and can be considered a promising treatment option in for the edentulous mandible.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA