Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Curr Opin Cardiol ; 38(6): 478-483, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37556404

RESUMO

PURPOSE OF REVIEW: Coronary artery disease is the third leading cause of mortality worldwide. Coronary artery surgery is an important treatment option. Certain groups such as people of color, those from lower socioeconomic backgrounds and women tend to have lower rates of receiving the surgery they need ( Fig. 1 ). RECENT FINDINGS: Still there are disparities in treatment options for coronary artery disease among different groups, due to geographic location, economical situation, institutional tradition and sex. SUMMARY: Through continued research, awareness and utilization of innovative technologies, we can improve access and equity in healthcare for all patients, including patients in need of coronary surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doença da Artéria Coronariana , Humanos , Feminino , Doença da Artéria Coronariana/cirurgia , Ponte de Artéria Coronária , Procedimentos Cirúrgicos Vasculares , Disparidades em Assistência à Saúde
2.
Scand Cardiovasc J ; 54(4): 220-226, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32408833

RESUMO

Objectives. In grading of aortic stenosis, two-dimensional transthoracic echocardiography (2D TTE) routinely results in underestimation of the left ventricular outflow tract (LVOT) area, and hence the aortic valve area (AVA). We investigated whether three-dimensional (3D) TTE measurements of the LVOT would be more accurate. We evaluated the feasibility, agreement and inter-observer variability of 3D TTE LVOT measurements with computed tomography (CT) and Haegar sizers as reference. Design. Sixty-one patients with severe aortic stenosis were examined with 2D and 3D TTE. 41 had CT and 13 also had perioperative Haegar sizing. Pearson's correlation and Bland-Altman plots were used to compare methods. Inter-observer variability was tested for 2D and 3D TTE. Trial registration: Current research information system in Norway (CRISTIN). Id: 555249. Results. Feasibility was 67% with 3D TTE and 100% with 2D TTE and CT. Mean LVOT area for 2D, 3D, CT and Haegar sizers were 3.7 ± 0.6 cm2, 4.0 ± 0.9 cm2, 5.2 ± 0.8 cm2 and 4.4 ± 1.0 cm2 respectively. Bias and limits of agreements for 2D TTE was 1.5 ± 1.3 cm2, compared with CT and 0.4 ± 1.5 cm2 with Haegar sizers. Corresponding results for 3D TTE were 1.2 ± 1.6 cm2 and 0.2 ± 1.8 cm2. Intraclass correlation coefficients for LVOT area were 0.62 for 3D and 0.86 for 2D. Conclusions. 2D TTE showed better feasibility and inter-observer variability in measurements of LVOT than 3D TTE. Both echocardiographic methods underestimated LVOT area compared to CT and Haegar sizers. These observations suggest that 2D TTE is still preferable to 3D TTE in the assessment of aortic stenosis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Estudos Transversais , Estudos de Viabilidade , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
Circulation ; 137(4): 388-399, 2018 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-29358344

RESUMO

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.


Assuntos
Bioprótese/classificação , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas/classificação , Valvas Cardíacas/cirurgia , Falha de Prótese , Terminologia como Assunto , Substituição da Valva Aórtica Transcateter/instrumentação , Remoção de Dispositivo , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Humanos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Scand Cardiovasc J ; 52(1): 43-50, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29233022

RESUMO

OBJECTIVES: The inflammatory response to on-pump cardiac surgery is well known. Systemic inflammatory response syndrome after transcatheter valve implantation (TAVI) has been reported. The objective of this study was to study the inflammatory response during TAVI, and compare with the response during surgical aortic valve replacement. METHODS: Eighteen patients undergoing transcatheter implantation, either by a transfemoral (n = 9) or transaortal (n = 9) approach were compared with eighteen patients admitted for surgical replacement. Blood samples per- and postoperatively were analysed for C3bc, terminal complement complex, myeloperoxidase, macrophage inflammatory protein-1ß, monocyte chemo-attractant peptide-1, eotaxin, IL-6 and troponin-T. All markers were measured at defined time points and the areas under the curve were compared. RESULTS: Activation of complement, granulocytes, monocytes and eosinophils were significantly lower in the transcatheter group as compared to the surgical group (<0.01). There was no difference in generation of troponin T and IL-6. A small difference in complement activation was observed between the transfemoral and transaortal placement of TAVI. There was no significant difference in clinical outcomes between the TAVI and surgical groups. DISCUSSION: Activation and release of inflammatory markers was significantly less during with TAVI as compared to SAVR, particularly for markers associated with extracorporeal circulation. TAVI and SAVR generated the same degree of IL-6 and troponin T, indicating that the burden on the myocardial tissue was the same. Clinical Trials: Gov ID: NCT03074838 Unique protocol ID: 2012/7919.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Ativação do Complemento , Citocinas/sangue , Feminino , Humanos , Mediadores da Inflamação/sangue , Masculino , Estudos Prospectivos , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/sangue , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue
7.
Catheter Cardiovasc Interv ; 86(5): 897-902, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25600032

RESUMO

Transcatheter valve implantation in the pulmonary valve has been established as a valuable treatment option for patients with conduit failure in the right ventricular outflow tract, most often with the use of the Melody valve. Transcatheter valve-in-valve (VIV) implantation in the tricuspid position is restricted to single case reports, most often with the implantation of the Edwards SAPIEN valve. A 67 years old male with carcionoid syndrome and previously implanted bioprosthesis in the pulmonary and tricuspid valve now presented with worsening symptoms due to degeneration of both bioprostheses. The risk of new open surgery was deemed to high. We report of the first transatrial double VIV implantation using the balloon expandable Edwards SAPIEN XT in pulmonary and tricuspid position.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Valva Tricúspide/cirurgia , Idoso , Ecocardiografia Doppler em Cores , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia
8.
J Cardiothorac Vasc Anesth ; 29(1): 115-20, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25620143

RESUMO

OBJECTIVE: Transcatheter aortic valve implantation in patients turned down for surgical aortic valve replacement is a high-risk procedure. Severe aortic stenosis is associated with impaired left ventricular longitudinal motion, and myocardial peak systolic velocity is a measure of left ventricular function in these patients. The present study aimed to quantify the acute changes in left ventricular function during the procedure by using myocardial tissue Doppler imaging and transthoracic cardiac output measurements. DESIGN: Prospective observational study. SETTING: Tertiary care university hospital. PARTICIPANTS: 40 patients with severe aortic stenosis scheduled for transcatheter aortic valve implantation. INTERVENTIONS: Transesophageal 4-chamber and 2-chamber echocardiograms were performed immediately before and ~15 minutes after valve implantation. Longitudinal myocardial peak systolic velocity was obtained by tissue Doppler imaging from 8 basal segments and averaged. Cardiac output was measured by the lithium dilution method, and systemic vascular resistance index and stroke volume were calculated. MEASUREMENTS AND MAIN RESULTS: Longitudinal myocardial peak systolic velocity improved immediately after valve implantation, from -2.3±0.8 to -3.0±1.1 cm/sec (p<0.001); this represented an average increase of 31%±33%. Cardiac output increased from 3.2±0.8 L/min to 3.6±0.9 L/min (15%±33%; p = 0.04). This was due to increased heart rate (59±9 beats/min to 72±12 beats/min; p<0.001) and not to an improved stroke volume. Systemic vascular resistance index was reduced from 2,937±984 dynes*sec/cm(5)/m(2) to 2,436±730 dynes*sec/cm(5)/m(2) (p = 0.003). CONCLUSION: Intraoperative echocardiography tissue Doppler imaging detected immediate improvement in left ventricular long-axis motion after transcatheter aortic valve implantation. The method provided detailed information not obtainable by routine hemodynamic monitoring.


Assuntos
Ecocardiografia Doppler/métodos , Monitorização Intraoperatória/métodos , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Prospectivos , Função Ventricular Esquerda/fisiologia
9.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007829

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/mortalidade , Masculino , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Fatores de Risco , Pessoa de Meia-Idade
10.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38152923

RESUMO

OBJECTIVES: Relevant paravalvular leakage (PVL) due to prosthesis dislodgement is a rare but potentially severe complication after transcatheter mitral valve implantation (TMVI). Due to the epicardial anchoring mechanism of the Tendyne® TMVI system, repositioning of the valve stent may be possible by retensioning of the tether. This multicentre study aimed to investigate the procedural and short-term safety as well as efficacy of retensioning manoeuvres. METHODS: From 2017 to 2021, N = 18 patients who underwent secondary tether retensioning were identified. Baseline, procedural and follow-up data were available from N = 11 patients and analysed according to the Mitral Valve Research Consortium definitions. Continuous variables are shown as median with interquartile range. RESULTS: All patients [age 75 years (73.5, 85.0), 64% male (N = 7), EuroSCORE II 6.2% (5.8, 11.6)] presented with post-procedural PVL [63.6% (N = 7) with PVL ≥3+]. Of these, 54% (N = 6) showed signs of haemolysis. The majority were severely symptomatic [New York Heart Association ≥III (91%, N = 10)]. Procedural outcomes revealed no acute complications and no mortality. At discharge, PVL was completely eliminated in 91% (N = 10) of patients with 1 case of remaining moderate PVL. At 30 days, Mitral Valve Research Consortium device success was achieved in 82% (N = 9) of patients. Two patients required open surgical mitral valve replacement due to persistent and recurrent PVL. In 89% (N = 8) of patients with successful retensioning procedure, New York Heart Association class was I/II. There was no 30-day mortality. CONCLUSIONS: This multicentre study demonstrates technical feasibility, procedural safety and acute efficacy of retensioning procedures in the majority of patients. The potential to retension the tether in transapical TMVI may provide additional management advantages in populations at high surgical risk.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , New York , Cateterismo Cardíaco/métodos
11.
Eur J Heart Fail ; 25(6): 890-901, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36519634

RESUMO

Over the past decade, transcatheter mitral valve replacement (TMVR) technologies have evolved with the objective of improving outcomes for patients with severe mitral regurgitation (MR) deemed unsuitable for conventional mitral valve surgery. Although the safety and efficacy of transcatheter edge-to-edge mitral valve repair (TEER) is well-established, there is a sense amongst innovators that a major advantage of TMVR may be to offer a more complete solution for the correction of MR in patients whose complex anatomy means that the likelihood of achieving grade 0 or 1 MR with TEER is low. However, abrupt correction of MR in a poorly prepared left ventricle poses a number of unique haemodynamic challenges, particularly when sudden elimination of regurgitant flow causes a relative increase in left ventricular (LV) afterload. Rapid reduction in LV cavity size following MR elimination may itself result in relative LV outflow tract obstruction (LVOTO), irrespective of the intrinsic risk of LVOTO associated with TMVR. Nevertheless, TMVR on a beating heart affords the opportunity to study real-time invasive cardiac indices in high-risk patients with acute reversal of severe MR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Fatores de Risco , Insuficiência Cardíaca/cirurgia , Resultado do Tratamento
12.
AsiaIntervention ; 9(1): 78-86, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36936096

RESUMO

Background: A comparison of 30-day and 1-year clinical outcomes in patients with pre-existing left ventricular (LV) dysfunction undergoing transcatheter mitral valve edge-to-edge repair (TEER) or transcatheter transapical mitral valve replacement (TMVR) has not previously been reported. Aims: We aimed to compare 30-day and 1-year rates of all-cause and cardiovascular mortality as well as rehospitalisation for heart failure (HFH). Methods: All patients with severe (≥3+) symptomatic mitral regurgitation (MR) and an LV ejection fraction ≤50% who underwent TEER or TMVR over a 5-year period were evaluated. Results: Ninety-six patients (50 TEER, age 80±9 years, 70% secondary MR and 46 TMVR, age 72±9 years, 91% secondary MR) were studied. Baseline demographic and transthoracic echocardiogram characteristics were well-matched, with the exception of age (TEER 80±9 vs TMVR 72±9; p=0.01). Successful device implantation occurred in 96% of TEER patients and 97.8% of TMVR patients. Ninety-two percent of TEER patients had ≤2+MR predischarge, whilst no TMVR patient had ≥1+MR (p<0.01). No significant difference in the combined endpoint of 30-day all-cause mortality or HFH was observed (p>0.05). At 1 year, freedom from all-cause mortality and HFH was 79.2% across the entire study population but was significantly higher in patients undergoing TEER (TEER: n=45 [90%] hazard ratio 11.26, 95% confidence interval [CI]: 10.59-11.93 vs TMVR: n=39 [67.4%] 95% CI: 10.09-11.33; p=0.008). Conclusions: Despite comparable rates of successful device implantation, MR reduction, and 30-day all-cause mortality/HFH, TEER patients had lower all-cause mortality and HFH rates at 1 year.

13.
J Heart Lung Transplant ; 42(8): 1005-1014, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37023840

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) provide circulatory blood pump support for severe heart failure patients. Pump inflow obstructions may lead to stroke and pump malfunction. We aimed to verify in vivo that gradual inflow obstructions, representing prepump thrombosis, are detectable by a pump-attached accelerometer, where the routine use of pump power (PLVAD) is deficient. METHOD: In a porcine model (n = 8), balloon-tipped catheters obstructed HVAD inflow conduits by 34% to 94% in 5 levels. Afterload increases and speed alterations were conducted as controls. We computed nonharmonic amplitudes (NHA) of pump vibrations captured by the accelerometer for the analysis. Changes in NHA and PLVAD were tested by a pairwise nonparametric statistical test. Detection sensitivities and specificities were investigated by receiver operating characteristics with areas under the curves (AUC). RESULTS: NHA remained marginally affected during control interventions, unlike PLVAD. NHA elevated during obstructions within 52-83%, while mass pendulation was most pronounced. Meanwhile, PLVAD changed far less. Increased pump speeds tended to amplify the NHA elevations. The corresponding AUC was 0.85-1.00 for NHA and 0.35-0.73 for PLVAD. CONCLUSION: Elevated NHA provides a reliable indication of subclinical gradual inflow obstructions. The accelerometer can potentially supplement PLVAD for earlier warnings and localization of pump.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Suínos , Animais , Coração Auxiliar/efeitos adversos , Trombose/diagnóstico , Curva ROC , Acelerometria , Insuficiência Cardíaca/cirurgia , Insuficiência Cardíaca/diagnóstico
14.
Ann Thorac Surg ; 2023 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-37717882

RESUMO

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

15.
EuroIntervention ; 19(6): 512-525, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37235388

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) using dedicated devices is an alternative therapy for high-risk patients with symptomatic mitral regurgitation (MR). AIMS: This study aimed to assess the 2-year outcomes and predictors of mortality in patients undergoing TMVR from the multicentre CHOICE-MI Registry. METHODS: The CHOICE-MI Registry included consecutive patients with symptomatic MR treated with 11 different dedicated TMVR devices at 31 international centres. The investigated endpoints included mortality and heart failure hospitalisation rates, procedural complications, residual MR, and functional status. Multivariable Cox regression analysis was applied to identify independent predictors of 2-year mortality. RESULTS: A total of 400 patients, median age 76 years (interquartile range [IQR] 71, 81), 59.5% male, EuroSCORE II 6.2% (IQR 3.8, 12.0), underwent TMVR. Technical success was achieved in 95.2% of patients. MR reduction to ≤1+ was observed in 95.2% at discharge with durable results at 1 and 2 years. New York Heart Association Functional Class had improved significantly at 1 and 2 years. All-cause mortality was 9.2% at 30 days, 27.9% at 1 year and 38.1% at 2 years after TMVR. Chronic obstructive pulmonary disease, reduced glomerular filtration rate, and low serum albumin were independent predictors of 2-year mortality. Among the 30-day complications, left ventricular outflow tract obstruction, access site and bleeding complications showed the strongest impact on 2-year mortality. CONCLUSIONS: In this real-world registry of patients with symptomatic MR undergoing TMVR, treatment with TMVR was associated with a durable resolution of MR and significant functional improvement at 2 years. Two-year mortality was 38.1%. Optimised patient selection and improved access site management are mandatory to improve outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Masculino , Idoso , Feminino , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Fatores de Risco , Sistema de Registros
16.
Eur J Heart Fail ; 25(3): 399-410, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36883620

RESUMO

AIMS: This study aimed to compare outcomes after transcatheter mitral valve replacement (TMVR) and mitral valve transcatheter edge-to-edge repair (M-TEER) for the treatment of secondary mitral regurgitation (SMR). METHODS AND RESULTS: The CHOICE-MI registry included 262 patients with SMR treated with TMVR between 2014 and 2022. The EuroSMR registry included 1065 patients with SMR treated with M-TEER between 2014 and 2019. Propensity score (PS) matching was performed for 12 demographic, clinical and echocardiographic parameters. Echocardiographic, functional and clinical outcomes out to 1 year were compared in the matched cohorts. After PS matching, 235 TMVR patients (75.5 years [70.0, 80.0], 60.2% male, EuroSCORE II 6.3% [interquartile range 3.8, 12.4]) were compared to 411 M-TEER patients (76.7 years [70.1, 80.5], 59.0% male, EuroSCORE II 6.7% [3.9, 12.4]). All-cause mortality was 6.8% after TMVR and 3.8% after M-TEER at 30 days (p = 0.11), and 25.8% after TMVR and 18.9% after M-TEER at 1 year (p = 0.056). No differences in mortality after 1 year were found between both groups in a 30-day landmark analysis (TMVR: 20.4%, M-TEER: 15.8%, p = 0.21). Compared to M-TEER, TMVR resulted in more effective mitral regurgitation (MR) reduction (residual MR ≤1+ at discharge for TMVR vs. M-TEER: 95.8% vs. 68.8%, p < 0.001), and superior symptomatic improvement (New York Heart Association class ≤II at 1 year: 77.8% vs. 64.3%, p = 0.015). CONCLUSION: In this PS-matched comparison between TMVR and M-TEER in patients with severe SMR, TMVR was associated with superior reduction of MR and superior symptomatic improvement. While post-procedural mortality tended to be higher after TMVR, no significant differences in mortality were found beyond 30 days.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Pontuação de Propensão , Resultado do Tratamento , Cateterismo Cardíaco/métodos
17.
Circ Cardiovasc Interv ; 16(6): e013045, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37194288

RESUMO

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. METHODS: The CHOICE-MI registry (Choice of Optimal Transcatheter Treatment for Mitral Insufficiency) included patients with MR undergoing TMVR using dedicated devices. Patients with MR pathogeneses other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation). We compared outcomes between the TMVR and GDMT groups, using propensity score matching to adjust for baseline differences. RESULTS: After propensity score matching, 97 patient pairs undergoing TMVR (72.9±8.7 years; 60.8% men; transapical access, 91.8%) versus GDMT (73.1±11.0 years; 59.8% men) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared with 6.9% and 7.7%, respectively, in those receiving GDMT alone (both P<0.001). The 2-year rate of heart failure hospitalization was significantly lower in the TMVR group (32.8% versus 54.4%; hazard ratio, 0.59 [95% CI, 0.35-0.99]; P=0.04). Among survivors, a higher proportion of patients were in the New York Heart Association functional class I or II in the TMVR group at 1 year (78.2% versus 59.7%; P=0.03) and at 2 years (77.8% versus 53.2%; P=0.09). Two-year mortality was similar in the 2 groups (TMVR versus GDMT, 36.8% versus 40.8%; hazard ratio, 1.01 [95% CI, 0.62-1.64]; P=0.98). CONCLUSIONS: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for heart failure, and similar mortality compared with GDMT. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT04688190 (CHOICE-MI) and NCT01626079 (COAPT).


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Feminino , Humanos , Masculino , Cateterismo Cardíaco/efeitos adversos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Pontuação de Propensão , Resultado do Tratamento
18.
Scand Cardiovasc J ; 46(6): 345-52, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22917262

RESUMO

OBJECTIVE: Transcatheter aortic valve implantation (TAVI) offers a new treatment option for patients with severe symptomatic aortic valve stenosis, classified as "inoperable". The purpose of the study was to reveal the association between ascertained hospital costs with the actual patient Diagnosis-Related Group (DRG). METHOD: We examined 50 consecutive patients who underwent either transapical TAVI, (TAVI-TA) or transfemoral TAVI (TAVI-TF) with the Edwards SAPIEN valve and CoreValve(®) between September 2009 and August 2011. RESULTS: Fourty-nine patients had successful valve deployment. Seven patients died within 30 days of the operation. The mean length of hospital stay for TAVI-TA was 199 hours (range 77-362), and the mean costs for TAVI-TA were 55,690 US$. For TAVI-TF the mean length of hospital stay was 170 hours (range 49-276) and the mean costs were 52,087 US$. CONCLUSION: There was no significant difference between TAVI-TA and TAVI-TF patient characteristics. There was a significant discrepancy between actual hospital costs and the current Norwegian DRG reimbursement for the TAVI procedure. This discrepancy can be partly explained by excessive costs related to the introduction of a new program with new technology. Costly innovations should be considered in price-setting of reimbursement for novel technology.


Assuntos
Estenose da Valva Aórtica/economia , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/economia , Implante de Prótese de Valva Cardíaca/economia , Custos Hospitalares , Reembolso de Seguro de Saúde , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Grupos Diagnósticos Relacionados , Difusão de Inovações , Feminino , Próteses Valvulares Cardíacas/economia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Tempo de Internação/economia , Masculino , Pessoa de Meia-Idade , Modelos Econômicos , Análise Multivariada , Análise de Regressão , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
19.
Front Med (Lausanne) ; 9: 1055465, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36405607

RESUMO

Extrapulmonary infections with Legionella species are rare, but important to acknowledge. We report a case of infective endocarditis (IE) with Legionella bozemanae in a 66-year-old immunocompetent man with an aortic homograft. The diagnosis was made by direct 16S rRNA gene amplification from valve material, confirmed by a targeted Legionella-PCR in serum and the detection of L. bozemanae specific antibodies. To our knowledge, this is the first confirmed case of IE with L. bozemanae as causative pathogen. The infected aortic prosthesis was replaced by a homograft, and the patient was successfully treated with levofloxacin and azithromycin for 6 weeks.

20.
Eur J Heart Fail ; 24(5): 899-907, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35064722

RESUMO

AIMS: Transcatheter mitral valve implantation (TMVI) is a new treatment option for patients with symptomatic mitral valve (MV) disease. Real-world data have not yet been reported. This study aimed to assess procedural and 30-day outcomes of TMVI in a real-world patient cohort. METHOD AND RESULTS: All consecutive patients undergoing implantation of a transapically delivered self-expanding valve at 26 European centres from January 2020 to April 2021 were included in this retrospective observational registry. Among 108 surgical high-risk patients included (43% female, mean age 75 ± 7 years, mean STS-PROM 7.2 ± 5.3%), 25% was treated for an off-label indication (e.g. previous MV intervention or surgery, mitral stenosis, mitral annular calcification). Patients were highly symptomatic (New York Heart Association [NYHA] functional class III/IV in 86%) and mitral regurgitation (MR) was graded 3+/4+ in 95% (38% primary, 37% secondary, and 25% mixed aetiology). Technical success rate was 96%, and MR reduction to ≤1+ was achieved in all patients with successful implantation. There were two procedural deaths and 30-day all-cause mortality was 12%. At early clinical follow-up, MR reduction was sustained and there were significant reductions of pulmonary pressure (systolic pulmonary artery pressure 52 vs. 42 mmHg, p < 0.001), and tricuspid regurgitation severity (p = 0.013). Heart failure symptoms improved significantly (73% in NYHA class I/II, p < 0.001). Procedural success rate according to MVARC criteria was 80% and was not different in patients treated for an off-label indication (74% vs. 81% for off- vs. on-label, p = 0.41). CONCLUSION: In a real-world patient population, TMVI has a high technical and procedural success rate with efficient and durable MR reduction and symptomatic improvement.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Insuficiência Cardíaca/etiologia , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA