Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 63(3): 853-860, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38294401

RESUMO

We present the simulation and design optimization of an integrated light-emitting-diode/photodetector (LED-PD) sensor system for monitoring of light absorbance changes developing in analyte-sensitive compounds. The sensor integrates monolithically both components in a single chip, offering advantages such as downsizing, reduced assembly complexity, and lower power consumption. The changes in the optical parameters of the analyte-sensitive ink are detected by monitoring the power transmission from the LED to the PD. Ray tracing and coupled modeling approach (CMA) simulations are employed to investigate the interaction of the emitted light with the ink. In highly absorbing media, CMA predicts more accurate results by considering evanescent waves. Simulations also suggest that an approximately 39% change in optical transmission can be achieved by adjusting the ink-deposited layer thickness and varying the extinction coefficient from 10-4 to 3×10-4.

2.
Opt Express ; 31(8): 12072-12082, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37157374

RESUMO

Electro-optic (EO) modulators are typically made of inorganic materials such as lithium niobate; the replacement of these modulators with organic EO materials is a promising alternative due to their lower half-wave voltage (Vπ), ease of handling, and relatively low cost. We propose the design and fabrication of a push-pull polymer electro-optic modulator with voltage-length parameters (VπL) of 1.28 V·cm. The device uses a Mach-Zehnder structure and is made of a second-order nonlinear optical host-guest polymer composed of a CLD-1 chromophore and PMMA polymer. The experimental results show that the loss is 1.7 dB, Vπ drops to 1.6 V, and the modulation depth is 0.637 dB at 1550 nm. The results of a preliminary study show that the device is capable of efficiently detecting electrocardiogram (ECG) signals with performance on par with that of commercial ECG devices.

3.
Sensors (Basel) ; 20(3)2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32033470

RESUMO

In this work, we present conductometric gas sensors based on p-type calcium iron oxide (CaFe2O4) nanoparticles. CaFe2O4 is a metal oxide (MOx) with a bandgap around 1.9 eV making it a suitable candidate for visible light-activated gas sensors. Our gas sensors were tested under a reducing gas (i.e., ethanol) by illuminating them with different light-emitting diode (LED) wavelengths (i.e., 465-640 nm). Regardless of their inferior response compared to the thermally activated counterparts, the developed sensors have shown their ability to detect ethanol down to 100 ppm in a reversible way and solely with the energy provided by an LED. The highest response was reached using a blue LED (465 nm) activation. Despite some responses found even in dark conditions, it was demonstrated that upon illumination the recovery after the ethanol exposure was improved, showing that the energy provided by the LEDs is sufficient to activate the desorption process between the ethanol and the CaFe2O4 surface.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA