1.
AIDS Res Hum Retroviruses ; 36(1): 65-74, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31516025

RESUMO

We investigated the use of a system with an ingestible sensor (Proteus Digital Health Feedback system) coencapsulated with antiretrovirals (ARVs) to measure real-time adherence. To assess the safety and impact, if any, coencapsulation might have on ARV concentrations, we evaluated the pharmacokinetics of ARVs coencapsulated with an ingestible sensor for eight commonly used fixed-dose combination ARVs: emtricitabine (FTC)/tenofovir disoproxil fumarate (TDF); FTC/tenofovir alafenamide (TAF); efavirenz (EFV)/FTC/TDF; abacavir (ABC)/lamivudine (3TC); dolutegravir (DTG)/ABC/3TC; rilpivirine (RPV)/TAF/FTC; elvitegravir (EVG)/cobicistat (COBI)/FTC/TAF; and bictegravir (BIC)/FTC/TAF. The steady-state apparent peak plasma concentration (Cmax) and area under the concentration-time curve (AUC) were determined from plasma concentrations measured at predose, 1, 2, 4, and 6 h postdose, and compared with literature values. A total of 49 unique patients on stable regimens for at least 12 weeks with undetectable viral loads were recruited. Cmax and AUC values were not statistically significantly different from literature values for all of the formulations except the Cmax of FTC/TDF, Cmax of BIC, and the Cmax of RPV. In a subsequent evaluation of FTC/TDF and BIC/FTC/TAF using a crossover design, the geometric mean ratio (GMR) between the coencapsulated and the unencapsulated formulations for FTC/TDF were the following: FTC, 84.6% (90% confidence interval [CI] 66.6-107.4) for AUC and 77.5% (60.1-99.9) for Cmax. For tenofovir (TFV), the GMR was 96.2% (90% CI 89.2-103.8) for AUC and 87.3% (64.2-118.7) for Cmax. The GMR for BIC (from the BIC/FTC/TAF formulation) was 98.0% (90% CI 84.5-113.5) for AUC and 89.9% (84.5-95.7) for Cmax. The observed deviation in FTC/TDF (Truvada) may be due to participant characteristics, fasted/fed conditions, and/or random variation and may warrant further investigations with a larger sample size. These findings provide assurance for use of coencapsulated ARVs for future HIV treatment-adherence research.


Assuntos
Fármacos Anti-HIV/farmacocinética , Técnicas Biossensoriais , Monitoramento de Medicamentos/instrumentação , Infecções por HIV/tratamento farmacológico , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Adulto , Fármacos Anti-HIV/administração & dosagem , Fármacos Anti-HIV/sangue , Estudos Cross-Over , Portadores de Fármacos , Composição de Medicamentos , Monitoramento de Medicamentos/métodos , Ingestão de Alimentos , Feminino , Humanos , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Carga Viral
2.
Clin Transl Sci ; 13(1): 189-194, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31536156

RESUMO

Adherence with antiretroviral therapy is important for preventing disease progression and HIV transmission. The co-encapsulated pill sensor system sends a signal through a cutaneous patch and allows real-time monitoring of pill ingestion. A 16-week pilot study used a sensor system in 15 HIV-infected individuals with real-time monitoring of pill-taking with a personalized short message system text. System acceptability was assessed by survey at weeks 4, 8, 12, and 16. Follow-up occurred in 80% of subjects through 8 weeks. The system effectively collected measures of pill ingestion, which triggered text message reminders. Only 2 of 14 participants stated that co-encapsulated pills were "unable to take" or "poorly tolerated." At least 75% of respondents stated at each visit that the patch was very or somewhat comfortable. With regard to text message reminders, only 10-15% of the participants at any visit did not find the messages to be helpful. Larger studies will define the utility of this system to assess antiretroviral adherence relative to standard measures.


Assuntos
Fármacos Anti-HIV/administração & dosagem , Composição de Medicamentos/métodos , Infecções por HIV/tratamento farmacológico , Adesão à Medicação , Monitorização Ambulatorial/métodos , Administração Oral , Adulto , Cápsulas/efeitos adversos , Deglutição , Composição de Medicamentos/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Satisfação do Paciente , Projetos Piloto , Envio de Mensagens de Texto , Dispositivos Eletrônicos Vestíveis , Tecnologia sem Fio/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA