Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 220
Filtrar
1.
Stroke ; 55(2): 454-462, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38174570

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a frequent underlying cause of cryptogenic stroke (CS) and its detection can be increased using implantable cardiac monitoring (ICM). We sought to evaluate different risk scores and assess their diagnostic ability in identifying patients with CS with underlying AF on ICM. METHODS: Patients with CS, being admitted to a single tertiary stroke center between 2017 and 2022 and receiving ICM, were prospectively evaluated. The CHA2DS2-VASc, HAVOC, Brown ESUS-AF, and C2HEST scores were calculated at baseline. The primary outcome of interest was the detection of AF, which was defined as at least 1 AF episode on ICM lasting for 2 consecutive minutes or more. The diagnostic accuracy measures and the net reclassification improvement were calculated for the 4 risk scores. Stroke recurrence was evaluated as a secondary outcome. RESULTS: A total of 250 patients with CS were included, and AF was detected by ICM in 20.4% (n=51) during a median monitoring period of 16 months. Patients with CS with AF detection were older compared with the rest (P=0.045). The median HAVOC, Brown ESUS-AF, and C2HEST scores were higher among the patients with AF compared with the patients without AF (all P<0.05), while the median CHA2DS2-VASc score was similar between the 2 groups. The corresponding C statistics for CHA2DS2-VASc, HAVOC, Brown ESUS-AF, and C2HEST for AF prediction were 0.576 (95% CI, 0.482-0.670), 0.612 (95% CI, 0.523-0.700), 0.666 (95% CI, 0.587-0.746), and 0.770 (95% CI, 0.699-0.839). The C2HEST score presented the highest diagnostic performance based on C statistics (P<0.05 after correction for multiple comparisons) and provided significant improvement in net reclassification for AF detection (>70%) compared with the other risk scores. Finally, stroke recurrence was documented in 5.6% of the study population, with no difference regarding the 4 risk scores between patients with and without recurrent stroke. CONCLUSIONS: The C2HEST score was superior to the CHA2DS2-VASc, HAVOC, and Brown ESUS-AF scores for discriminating patients with CS with underlying AF using ICM.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , AVC Isquêmico/complicações
2.
Circulation ; 145(1): 61-78, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34965168

RESUMO

Inflammation plays a prominent role in the development of atherosclerosis and other cardiovascular diseases, and anti-inflammatory agents may improve cardiovascular outcomes. For years, colchicine has been used as a safe and well-tolerated agent in diseases such as gout and familial Mediterranean fever. The widely available therapeutic has several anti-inflammatory effects, however, that have proven effective in a broad spectrum of cardiovascular diseases as well. It is considered standard-of-care therapy for pericarditis, and several clinical trials have evaluated its role in postoperative and postablation atrial fibrillation, postpericardiotomy syndrome, coronary artery disease, percutaneous coronary interventions, and cerebrovascular disease. We aim to summarize colchicine's pharmacodynamics and the mechanism behind its anti-inflammatory effect, outline thus far accumulated evidence on treatment with colchicine in cardiovascular disease, and present ongoing randomized clinical trials. We also emphasize real-world clinical implications that should be considered on the basis of the merits and limitations of completed trials. Altogether, colchicine's simplicity, low cost, and effectiveness may provide an important addition to other standard cardiovascular therapies. Ongoing studies will address complementary questions pertaining to the use of low-dose colchicine for the treatment of cardiovascular disease.


Assuntos
Doenças Cardiovasculares/tratamento farmacológico , Colchicina/uso terapêutico , Supressores da Gota/uso terapêutico , Colchicina/farmacologia , Supressores da Gota/farmacologia , Humanos
3.
J Cardiovasc Electrophysiol ; 33(3): 527-539, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34951496

RESUMO

INTRODUCTION: Early arrhythmia recurrence within the 3-month blanking period is a common event that historically has been attributed to reversible phenomena. While its mechanistic links remain obscure, accumulating evidence support the argument of shortening the blanking period. We aimed to elucidate the association between early and late arrhythmia recurrence after atrial fibrillation cryoablation. METHODS: The MEDLINE database, ClinicalTrials. gov, medRxiv, and Cochrane Library were searched for studies evaluating early and late arrhythmia recurrence rates in patients undergoing cryoablation for atrial fibrillation. Data were pooled by meta-analysis using a random-effects model. The primary endpoint was late arrhythmia recurrence. RESULTS: Early arrhythmia recurrence was found predictive of decreased arrhythmia-free survival after evaluating 3975 patients with paroxysmal or persistent atrial fibrillation who underwent cryoablation (odds ratio [OR]: 5.31; 95% confidence interval [CI]: 3.75-7.51). This pattern remained unchanged after subanalyzing atrial fibrillation type (paroxysmal; OR: 7.16; 95% CI: 4.40-11.65 and persistent; OR: 7.63; 95% CI: 3.62-16.07) as well as cryoablation catheter generation (first generation; OR: 5.15, 95% CI: 2.39-11.11 and advanced generation; OR: 5.83, 95% CI: 3.68-9.23). Studies permitting antiarrhythmic drug utilization during the blanking period or examining early recurrence as a secondary outcome were found to be a significant source of statistical heterogeneity. CONCLUSION: Our findings suggest that early arrhythmia recurrence is predictive of late outcomes after cryoablation for atrial fibrillation. Identifying which patients deserve earlier reintervention is an open research avenue.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 45(6): 717-725, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35554947

RESUMO

OBJECTIVES: Many of the complications arising from cardiac device implantation are associated to the venous access used for lead placement. Previous analyses reported that cephalic vein cutdown (CVC) is safer but less effective than subclavian vein puncture (SVP). However, comparisons between these techniques and axillary vein puncture (AVP) - guided either by ultrasound or fluoroscopy - are lacking. Thus, we aimed to compare safety and efficacy of these approaches. METHODS: We searched for articles assessing at least two different approaches regarding the incidence of pneumothorax and/or lead failure (LF). When available, bleeding and infectious complications as well as procedural success were analyzed. A frequentist random effects network meta-analysis model was adopted. RESULTS: Thirty-six studies were analyzed. Most articles assessed SVP versus CVC. Compared to SVP, both CVC and AVP were associated with reduced odds of pneumothorax (OR: 0.193, 95%CI: 0.136-0.275 and OR: 0.128, 95%CI: 0.050-0.329; respectively) and LF (OR: 0.63, 95%CI: 0.406-0.976 and OR: 0.425, 95%CI: 0.286-0.632; respectively). No significant differences between AVP and CVC were demonstrated. Limited data suggests no major impact of different approaches on infectious and bleeding complications. Initial CVC approach required significantly more often an alternate/additional venous access for lead placement, compared to both AVP and SVP. No differences between these two were identified. CONCLUSION: Both AVP and CVC seem to decrease incident pneumothorax and LF, compared to SVP. Initial AVP approach seems to decrease the need of alternate venous access, compared to CVC. These results suggest that AVP should be further clinically tested.


Assuntos
Cateterismo Venoso Central , Pneumotórax , Cateterismo Venoso Central/métodos , Eletrônica , Humanos , Metanálise em Rede , Veia Subclávia , Venostomia/métodos
5.
Ann Neurol ; 88(5): 946-955, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32827232

RESUMO

OBJECTIVE: In this study, we sought to evaluate the impact of implantable cardiac monitoring (ICM) in the prevention of stroke recurrence after a cryptogenic ischemic stroke or transient ischemic attack (TIA). METHODS: We evaluated consecutive patients with cryptogenic ischemic stroke or TIA admitted in a comprehensive stroke center during an 8-year period. We compared the baseline characteristics and outcomes between patients receiving conventional cardiac monitoring with repeated 24-hour Holter-monitoring during the first 5 years in the outpatient setting and those receiving continuous cardiac monitoring with ICM during the last 3 years. Associations on the outcomes of interest were further assessed in multivariable regression models adjusting for potential confounders. RESULTS: We identified a total of 373 patients receiving conventional cardiac monitoring and 123 patients receiving ICM. Paroxysmal atrial fibrillation (PAF) detection was higher in the ICM cohort compared to the conventional cardiac monitoring cohort (21.1% vs 7.5%, p < 0.001). ICM was independently associated with an increased likelihood of PAF detection during follow-up (hazard ratio [HR] = 1.94, 95% confidence interval [CI] = 1.16-3.24) in multivariable analyses. Patients receiving ICM were also found to have significantly higher rates of anticoagulation initiation (18.7% vs 6.4%, p < 0.001) and lower risk of stroke recurrence (4.1% vs 11.8%, p = 0.013). ICM was independently associated with a lower risk of stroke recurrence during follow-up (HR = 0.32, 95% CI = 0.11-0.90) in multivariable analyses. INTERPRETATION: ICM appears to be independently associated with a higher likelihood of PAF detection and anticoagulation initiation after a cryptogenic ischemic stroke or TIA. ICM was also independently related to lower risk of stroke recurrence in our cryptogenic stroke / TIA cohort. ANN NEUROL 2020;88:946-955.


Assuntos
Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Coração/fisiopatologia , AVC Isquêmico/prevenção & controle , Próteses e Implantes , Prevenção Secundária/métodos , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Diagnóstico Precoce , Eletrocardiografia Ambulatorial , Feminino , Humanos , Ataque Isquêmico Transitório/prevenção & controle , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Prospectivos , Recidiva , Resultado do Tratamento
6.
Cardiovasc Drugs Ther ; 35(2): 293-308, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33400054

RESUMO

PURPOSE: We sought to indirectly compare and rank antiarrhythmic agents focusing exclusively on adults with paroxysmal atrial fibrillation in order to identify the most effective for pharmacologic cardioversion over different time settings (4 h as primary, and 12, 24 h as secondary outcomes). METHODS: We searched several databases from inception to March 2020 without language restrictions, ClinicalTrials.gov, references of reviews, and meeting abstract material. We included randomized controlled trials of patients with AF lasting ≤7 days comparing either two or more intravenous (i.v.) or oral (p.o.) pharmacologic cardioversion agents or an agent against placebo. For each outcome, we performed network meta-analysis based on the frequentist approach. RESULTS: Forty-one trials (6013 patients) were included in our systematic review. Moderate confidence evidence suggests that i.v. vernakalant and flecainide have the highest conversion rate within 4 h, possibly allowing discharge from the emergency department and reducing hospital admissions. Intravenous and p.o. formulations of class IC antiarrhythmics (flecainide more so than propafenone) are superior regarding conversion rates within 12 h, while amiodarone efficacy is exhibited in a delayed fashion (within 24 h), especially if ranolazine is added. CONCLUSION: Our network meta-analysis identified with sufficient power and consistency the most effective antiarrhythmics for pharmacologic cardioversion over different time settings, with vernakalant and flecainide exhibiting a safer and more efficacious profile toward faster cardioversion.


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Anisóis/uso terapêutico , Antiarrítmicos/administração & dosagem , Antiarrítmicos/efeitos adversos , Flecainida/uso terapêutico , Humanos , Pirrolidinas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Curr Atheroscler Rep ; 22(6): 21, 2020 05 28.
Artigo em Inglês | MEDLINE | ID: mdl-32468244

RESUMO

PURPOSE OF REVIEW: In this review article, we focus on the mechanisms and features of acute coronary syndromes (ACS) with no ruptured plaque (NONRUPLA) highlighting the uncertainties over diagnostic evaluation and treatment. RECENT FINDINGS: The most common cause of ACS is obstruction due to atherosclerotic plaque ruptured or erosion. In 14% of patients who present in the Emergency Department as myocardial infarction, the final diagnosis is ACS with NONRUPLA. Although the clinical presentation of NONRUPLA may mimic myocardial infarction, the underlying pathogenesis is different, and it may guide therapeutic approaches and overall prognosis that vary according to etiology. The possible mechanisms of ACS with NONRUPLA are coronary embolism, acute dissection of the aorta or coronary artery, vasospasm, microvascular dysfunction, the imbalance between oxygen demand and supply, coronary trauma and stent complications, direct cellular toxicity and damage, Takotsubo syndrome, and myocardial infarction with non-obstructive coronary arteries (MINOCA).


Assuntos
Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/diagnóstico , Infarto do Miocárdio/diagnóstico , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
8.
J Cardiovasc Electrophysiol ; 30(7): 991-998, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30938914

RESUMO

BACKGROUND: Isolation of the pulmonary veins (PVI) has become a mainstay in atrial fibrillation (AFib) therapy. Lesions in left atrial tissue lead to scar formation and this may affect left atrial function. METHODS: Patients with paroxysmal AFib were randomly assigned in a 1:2 allocation scheme to radiofrequency (RF) ablation or cryoballoon. Real-time three-dimensional echocardiography was performed (under sinus rhythm in all cases) before ablation and at 1 and 3 months to evaluate the left atrial functional indices. The primary outcome measure was change in left atrial ejection fraction (LAEF) at 1 month. RESULTS: 120 patients were randomized (80 to cryoballoon, 40 to RF). The absolute change in LAEF at 1 month was 4.0 (Q1-Q3, -0.1to 7.6)% in the cryoballoon group and -0.8 (Q1-Q3, -1.9 to 0.9)% in the RF group (P < 0.001 for the comparison between groups). At 3 months, the corresponding changes were 6.7 (Q1-Q3, 3.4-11.2)% and 0.7 (Q1-Q3, -0.7 to 3.5)%, respectively (P < 0.001). Overall, the rate of patients with lower LAEF at 3 months compared to baseline was 2.5% in the cryoballoon group and 32.5% in the RF group (P < 0.001). AFib recurrence rate at 6 months was higher in patients with decreased LAEF (odds ratio, 6.2; 95% confidence interval, 2.0-19.5; P = 0.002). CONCLUSION: The Cryo-LAEF study prospectively compared the effects of RF and cryoballoon ablation on left atrial function. Both at 1 and 3 months postablation, LAEF was either improved or stable in both ablation groups.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Ecocardiografia Tridimensional , Feminino , Grécia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recuperação de Função Fisiológica , Recidiva , Fatores de Tempo , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 30(11): 2362-2369, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31502366

RESUMO

INTRODUCTION: Electronatomical mapping allows direct and accurate visualization of myocardial abnormalities. This study investigated whether high-density endocardial bipolar voltage mapping of the right ventricular outflow tract (RVOT) during sinus rhythm may guide catheter ablation of idiopathic ventricular arrhythmias (VAs). METHODS AND RESULTS: Forty-four patients (18 males, mean age: 38.1 ± 13.8 years) with idiopathic RVOT VAs and negative cardiac magnetic resonance imaging underwent a stepwise mapping approach for the identification of the site of origin (SOO). High-density electronatomical mapping (1096.6 ± 322.3 points) was performed during sinus rhythm and identified at least two low bipolar voltage areas less than 1 mV (mean amplitude of 0.20 ± 0.10 mV) in 39 of 44 patients. The mean low-voltage surface area was 1.4 ± 0.8 cm2 . Group 1 consisted of 28 patients exhibiting low-voltage areas and high-arrhythmia burden during the procedure. Pace match to the clinical VAs was produced in one of these low-voltage areas. Activation mapping established the SOO at these sites in 27 of 28 cases. Group 2 comprised 11 patients exhibiting abnormal electroanatomical mapping, but very low-arrhythmia burden during the procedure. Pace mapping produced a near-perfect or perfect match to the clinical VAs in one of these areas in 9 of 11 patients which was marked as potential SOO and targeted for ablation. During the follow-up period, 25 of 28 patients from group 1 (89%) and 7 of 9 patients from group 2 (78%) were free from VAs. CONCLUSIONS: Small but detectable very low-voltage areas during mapping in sinus rhythm characterize the arrhythmogenic substrate of idiopathic RVOT VAs and may guide successful catheter ablation.


Assuntos
Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/diagnóstico , Função Ventricular Direita , Complexos Ventriculares Prematuros/diagnóstico , Adulto , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia
10.
Europace ; 21(12): 1911-1918, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638693

RESUMO

AIMS: Risk stratification in Brugada syndrome (BrS) still represents an unsettled issue. In this multicentre study, we aimed to evaluate the clinical characteristics and the long-term clinical course of patients with BrS. METHODS AND RESULTS: A total of 111 consecutive patients (86 males; aged 45.3 ± 13.3 years) diagnosed with BrS were included and followed-up in a prospective fashion. Thirty-seven patients (33.3%) were symptomatic at enrolment (arrhythmic syncope). An electrophysiological study (EPS) was performed in 59 patients (53.2%), and ventricular arrhythmias were induced in 32 (54.2%). A cardioverter defibrillator was implanted in 34 cases (30.6%). During a mean follow-up period of 4.6 ± 3.5 years, appropriate device therapies occurred in seven patients. Event-free survival analysis (log-rank test) showed that spontaneous type-1 electrocardiogram pattern (P = 0.008), symptoms at presentation (syncope) (P = 0.012), family history of sudden cardiac death (P < 0.001), positive EPS (P = 0.024), fragmented QRS (P = 0.004), and QRS duration in lead V2 > 113 ms (P < 0.001) are predictors of future arrhythmic events. Event rates were 0%, 4%, and 60% among patients with 0-1 risk factor, 2-3 risk factors, and 4-5 risk factors, respectively (P < 0.001). Current multiparametric score models exhibit an excellent negative predictive value and perform well in risk stratification of BrS patients. CONCLUSIONS: Multiparametric models including common risk factors appear to provide better risk stratification of BrS patients than single factors alone.


Assuntos
Síndrome de Brugada/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Taquicardia Ventricular/epidemiologia , Fibrilação Ventricular/epidemiologia , Adulto , Síndrome de Brugada/complicações , Síndrome de Brugada/terapia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Anamnese , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Medição de Risco , Fatores de Risco , Síncope/etiologia , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia
11.
Vasa ; 48(3): 236-243, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30526401

RESUMO

Background: The 2017 ACC/AHA blood pressure (BP) guidelines generated controversies due to the new proposed BP cut-off values defining hypertension. We aimed to assess aortic stiffness of subjects who are reclassified as stage 1 hypertensive according to the new guidelines and compare them with the subjects of "elevated BP" category. Patients and methods. Data from the "Corinthia" study, an observational, cross-sectional survey of 2,043 participants were analyzed. Subjects were classified into 4 groups: group A: systolic pressure (SBP) 120-129 and diastolic pressure (DBP) < 80 mmHg, group B: SBP 130-139 or DBP 80-89 mmHg, group B1: SBP 130-139 and DBP < 80 mmHg and group B2: SBP 130-139 and DBP 80-89 mmHg. Aortic stiffness was assessed by carotid-to-femoral pulse wave velocity (PWV). A value of PWV > 10m/s was consider indicative of asymptomatic organ damage while values of PWV exceeded the 90 % percentile for each age group were consider as abnormal. Results: Groups B, B1 and B2 have significantly increased PWV compared to group A, independently from age and other risk factors (PWV: 9.2 ± 2.8 vs 9.4 ± 2.7 vs 8.6 ± 2.5 vs 8.1 ± 2.3 m/s, p < 0.01, respectively). The prevalence of PWV > 10 m/s and abnormal PWV values in group A was significantly lower than the corresponding prevalence in randomly selected, age-matched subjects from group B (13.5 % vs 24.4 %, p = 0.027 and 5.6 % vs 14.2 %, p = 0.022, respectively). Conclusions: The reclassified subjects as stage 1 hypertensive by the new guidelines have a significantly increased aortic stiffness and greater prevalence in asymptomatic aortic damage compared to subjects with elevated BP. This finding may indirectly explain the increased cardiovascular risk of this group.


Assuntos
Hipertensão , Rigidez Vascular , Pressão Sanguínea , Estudos Transversais , Humanos , Análise de Onda de Pulso
12.
Stroke ; 49(8): 1992-1995, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29991656

RESUMO

Background and Purpose- Scarce data indicate that statin pretreatment (SP) in patients with acute cerebral ischemia because of large artery atherosclerosis may be related to lower risk of recurrent stroke because of a decreased incidence of microembolic signals (MES) during transcranial Doppler monitoring. Methods- We performed a systematic review and meta-analysis of available observational studies reporting MES presence/absence or MES burden, categorized according to SP status, in patients with acute cerebral ischemia because of symptomatic (≥50%) large artery atherosclerosis. In studies with partially-published data, authors were contacted for previously unpublished information. We also performed a sensitivity analysis of studies with data on MES burden categorized according to SP status, and an additional subgroup analysis in patients receiving higher-dose SP (atorvastatin 80 mg or rosuvastatin 40 mg daily). Results- Seven eligible study protocols were identified (610 patients, 54% with SP). SP was associated with a reduced risk of MES detection during transcranial Doppler monitoring (risk ratio=0.67; 95% CI, 0.45-0.98), with substantial heterogeneity between studies ( I2=52%). In studies reporting MES burden (n=4), a significantly lower number of MES were identified in patients with compared with those without SP (mean difference=-0.92; 95% CI, -1.64 to -0.19), with no evidence of heterogeneity between studies ( I2=49%). Subgroup analysis revealed that higher-dose SP reduced the risk of detecting MES (risk ratio=0.23; 95% CI, 0.06-0.88), with no evidence of heterogeneity between studies ( I2=0%). Conclusions- SP seems to be associated with a lower incidence and burden of MES in patients with acute cerebral ischemia because of large artery atherosclerosis.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Arteriosclerose Intracraniana/diagnóstico por imagem , Embolia Intracraniana/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Isquemia Encefálica/tratamento farmacológico , Humanos , Arteriosclerose Intracraniana/tratamento farmacológico , Embolia Intracraniana/tratamento farmacológico , Microvasos/efeitos dos fármacos
13.
Arterioscler Thromb Vasc Biol ; 37(7): 1415-1422, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28450295

RESUMO

OBJECTIVE: Although statin pretreatment (SP) is associated with better outcomes in patients with acute cerebral ischemia after an ischemic stroke/transient ischemic attack, data on the underlying mechanism of this beneficial effect are limited. APPROACH AND RESULTS: We sought to evaluate the potential association between SP and microembolic signal (MES) burden in acute cerebral ischemia because of large artery atherosclerosis (LAA). We prospectively evaluated consecutive patients with first-ever acute cerebral ischemia because of LAA in 3 tertiary stroke centers over a 2-year period. All patients underwent continuous 1-hour transcranial Doppler monitoring of the relevant vessel at baseline (≤24 hours). SP was recorded and dichotomized as high dose or low-to-moderate dose. SP was documented in 43 (41%) of 106 LAA patients (mean age, 65.4±10.3 years; 72% men; low-to-moderate dose, 32%; high dose, 8%). There was a significant (P=0.022) dose-dependent effect between SP and MES prevalence: no SP (37%), SP with low-to-moderate dose (18%), and SP with high dose (0%). Similarly, a significant (P=0.045) dose-dependent effect was documented between SP and MES burden: no SP (1.1±1.8), SP with low-to-moderate dose (0.7±1.6), and SP with high dose (0±0). In multivariable logistic regression analysis adjusting for demographics, vascular risk factors, location of LAA, stroke severity, and other prevention therapies, SP was associated with lower likelihood of MES presence (odds ratio, 0.29; 95% confidence interval, 0.09-0.92; P=0.036). In addition, SP was found also to be independently related to higher odds of functional improvement (common odds ratio, 3.33; 95% confidence interval, 1.07-10.0; P=0.037). CONCLUSIONS: We found that SP in patients with acute LAA is related with reduced MES presence and lower MES burden with an apparently dose-dependent association.


Assuntos
Isquemia Encefálica/prevenção & controle , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Arteriosclerose Intracraniana/tratamento farmacológico , Embolia Intracraniana/prevenção & controle , Ataque Isquêmico Transitório/prevenção & controle , Idoso , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/epidemiologia , Angiografia Cerebral/métodos , Distribuição de Qui-Quadrado , Angiografia por Tomografia Computadorizada , Relação Dose-Resposta a Droga , Feminino , Alemanha/epidemiologia , Grécia/epidemiologia , Humanos , Arteriosclerose Intracraniana/diagnóstico por imagem , Arteriosclerose Intracraniana/epidemiologia , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/epidemiologia , Modelos Logísticos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Prevalência , Estudos Prospectivos , Fatores de Risco , Singapura/epidemiologia , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
14.
J Cardiovasc Pharmacol ; 72(6): 285-290, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30520854

RESUMO

BACKGROUND: Statins have been proposed as a means to prevent postablation atrial fibrillation (AF) recurrences, mainly on the basis of their pleiotropic effects. The objective of this subanalysis of a prospectively randomized controlled study population of patients undergoing radiofrequency ablation for paroxysmal AF was to test the hypothesis that statin treatment is associated with longer time to recurrence. METHODS AND RESULTS: This is a subanalysis over an extended follow-up period of a prospective randomized study (ClinicalTrials.gov Identifier NCT01791699). Among 291 patients, 2 propensity score-matched subgroups of patients who received or did not receive statins after pulmonary vein isolation were created. In the unmatched cohort, there was no difference in the rate of recurrence between statin-treated and not treated patients, with a 1-year recurrence estimate of 19% and 23%, respectively (Gehan statistic 0.59, P = 0.443). In the propensity-matched cohort (N = 166, 83 per group), recurrence-free survival did not differ significantly between groups (839 days, 95% confidence interval 755-922 days, in the no statin group vs. 904 days, 95% confidence interval 826-983 in the statin group; P = 0.301). The 1-year recurrence rate estimate was 30% in the no statin group versus 27% in the statin group (Gehan statistic 0.56, P = 0.455). CONCLUSION: Statin treatment does not seem to affect AF recurrence in following radiofrequency ablation for paroxysmal AF, over a follow-up time of about 2.5 years.


Assuntos
Fibrilação Atrial/cirurgia , Inibidores de Hidroximetilglutaril-CoA Redutases/administração & dosagem , Veias Pulmonares/cirurgia , Ablação por Radiofrequência , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Grécia , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Ablação por Radiofrequência/efeitos adversos , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Europace ; 20(1): 134-139, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28087596

RESUMO

Aims: The early repolarization (ER) pattern has been linked to an increased risk for arrhythmic death in various clinical settings. There are limited and conflicting data regarding the prognostic significance of ER pattern in Brugada syndrome (BS). The aim of this meta-analysis was to provide a detailed analysis of the currently available studies regarding the arrhythmic risk in patients with BS and ER pattern. Methods and results: Current databases were searched until May 2015. A random-effect meta-analysis of the effect of ER pattern on the incidence of arrhythmic events in patients with BS was performed. Five studies were included comprising a total of 1375 patients with BS. An ER pattern was reported in 177 patients (12.8%). During follow-up (44.9-93 months), 143 patients (10.4%) suffered an arrhythmic event. Overall, BS patients with ER pattern displayed an increased risk of arrhythmic events compared to patients without ER (OR 3.29, 95% CI: 2.06 to 5.26, P < 0.00001; Heterogeneity: P = 0.11, I2 = 48%). Three studies provided data regarding ER pattern location. Inferior, lateral, or inferolateral ER pattern location was observed in 20.3%, 32.2%, and 48%, respectively. An inferolateral ER location conferred the higher arrhythmic risk (OR 4.87, 95% CI: 2.64 to 9.01, P< 0.00001; Heterogeneity: P = 0.85, I2 = 0%). Conclusion: This meta-analysis suggests that the ER pattern is associated with a high risk of arrhythmic events in patients with BS. In particular, BS patients with inferolateral ER (global ER pattern) displayed the highest arrhythmic risk.


Assuntos
Síndrome de Brugada/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Potenciais de Ação , Adulto , Idoso , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/mortalidade , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Prognóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo
17.
Pacing Clin Electrophysiol ; 41(9): 1129-1135, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30028029

RESUMO

BACKGROUND: Left atrial appendage (LAA) functional modification in the context of pulmonary vein isolation has been a focus point of research and LAA emptying flow velocity (LAAEFV) is considered to reflect LAA contractility, stunning, and fibrosis. OBJECTIVE: In the present study, we sought to prospectively evaluate short-term LAAEFV changes after radiofrequency (RF) or cryoballoon ablation in paroxysmal AF. METHODS: This was a prospective substudy of the Effect of Cryoballoon and RF Ablation on Left Atrial Function (CryoLAEF) study (ClinicalTrials.gov Identifier: NCT02611869). Thirty patients, randomly assigned to RF or cryoablation, were prospectively followed. Transesophageal echocardiograms were performed at baseline and at 3 months postablation to measure LAAEFV. RESULTS: All measurements were performed in sinus rhythm. Overall, LAAEFV was 44.2 [38.5-62.8] cm/s at baseline and was increased to 70.8 [64.8-77.6] cm/s at 3 months' postablation (P < 0.001). Baseline LAAEFV was 52.5 [37.7-68.0] cm/s in the RF group and 42.8 [38.7-52.9] cm/s in the CryoBalloon group (P  =  0.653). At 3 months, the corresponding values were 68.5 [61.9-76.6] cm/s and 73.9 [69.2-79.9] cm/s, respectively (P  =  0.081 for the difference between the two groups at 3 months). The median change in LAAEFV was 11.0 [4.7-26.2] cm/s in the RF group versus 29.6 [15.8-37.0] cm/s in the CryoBalloon group (P  =  0.033). CONCLUSION: LAA function is improved after catheter ablation with RF or balloon cryoablation in patients with paroxysmal AF, evaluated while in sinus rhythm both at baseline and on follow-up.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
18.
J Surg Res ; 207: 164-173, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27979473

RESUMO

BACKGROUND: The adverse effects of myocardial ischemia and reperfusion during cardiopulmonary bypass (CPB) have been thoroughly described. Lazaroid U-74389G, a 21 aminosteroid, has been shown to attenuate ischemia and reperfusion injury and improve recovery in a variety of experimental models. METHODS: Sixteen male swine were randomly divided in two groups. All animals underwent 45 min of ischemic cardioplegic arrest, with U-74389G addition to the standard cardioplegic solution, whereas controls underwent the same procedure without U-74389G. Creatine kinase-MB isoenzyme (CK-MB) and cardiac troponin T levels were measured immediately before CPB (time point 0), during the ischemic period (time point 1) and 30 (time point 2), 60 (time point 3), and 120 (time point 4) min after reperfusion. Myocardial biopsies were obtained at time points 0 and 4. RESULTS: CK-MB levels (in U/L) at time points 0-4 were 205 (186-235) versus 219 (196-269; P = 0.72), 215 (167-248) versus 253 (193-339; P = 0.23), 234 (198-255) versus 338 (249-441; P = 0.02), 244 (217-272) versus 354 (269-496; P = 0.01), and 285 (230-321) versus 439 (432-530; P < 0.01) in lazaroid-treated animals versus controls, respectively. Cardiac troponin T levels (in ng/L) at time points 0-4 were 58 (26-287) versus 237 (26-395; P = 0.72), 129 (61-405) versus 265 (145-525; P = 0.23), 261 (123-467) versus 474 (427-1604; P = 0.04), 417 (204-750) versus 841 (584-1818; P = 0.11), and 643 (353-1259) versus 1600 (1378-2313; P < 0.01), respectively. Necrosis grades at time point 4 were 0.0 (0.0-1.0) versus 1.5 (1.0-2.0; P < 0.01) in lazaroid-treated animals versus controls, respectively. CONCLUSIONS: The present study, in addition to reconfirming the well-described adverse effects of CPB, demonstrates the efficacy of the newer generation lazaroid U-74389G in alleviating these effects.


Assuntos
Cardiotônicos/uso terapêutico , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Pregnatrienos/uso terapêutico , Animais , Biomarcadores/metabolismo , Biópsia , Masculino , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Miocárdio/metabolismo , Miocárdio/patologia , Necrose , Distribuição Aleatória , Suínos , Resultado do Tratamento
20.
Europace ; 19(12): 1967-1972, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29194518

RESUMO

AIMS: Vagal responses (VR) during left atrial ablation for atrial fibrillation (AF) treatment have been reported to be associated with less recurrences, presumably because they are a sign of ganglionated plexi modification. Our objective was to evaluate whether coincidentally elicited VR during left atrial ablation are associated with lower AF recurrence rates. METHODS AND RESULTS: This is a post hoc analysis of a prospective study of 291 patients with paroxysmal AF undergoing radiofrequency pulmonary vein isolation (PVI). Vagal responses were defined as episodes of heart rate <40 bpm or asystole lasting >5 s elicited during energy application. Sixty-eight patients (23.4%) had a VR during ablation. In Kaplan-Meier analysis, mean recurrence-free survival was 449 days (95% confidence interval 411-488) in patients with VR when compared with 435 days (95% confidence interval 415-455) in those without (P = 0.310). The 12-month recurrence rate estimates were 25 and 27%, respectively. In an unadjusted Cox model, VR was associated with an odds ratio for recurrence of 0.77 (95% confidence interval 0.46-1.28). CONCLUSION: Coincidentally elicited VR during radiofrequency PVI in patients with paroxysmal AF do not appear to be related to lower risk of arrhythmia recurrence. This may mean that, even if a VR is truly a sign of coincidental ablation of a ganglionated plexus, this does not necessarily mean that a therapeutic modification has been effected, at least to a degree associated with clinical benefit.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Gânglios Parassimpáticos/cirurgia , Veias Pulmonares/cirurgia , Nervo Vago/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Intervalo Livre de Doença , Feminino , Gânglios Parassimpáticos/fisiopatologia , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Veias Pulmonares/inervação , Veias Pulmonares/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Nervo Vago/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA