Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
1.
Europace ; 26(5)2024 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-38743765

RESUMO

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Assuntos
Consenso , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Europa (Continente) , Resultado do Tratamento
2.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646926

RESUMO

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Feminino , Masculino , Recidiva , Europa (Continente) , Pessoa de Meia-Idade
3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584423

RESUMO

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Fatores de Risco , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidência , Insuficiência Cardíaca/complicações , Ásia/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações
4.
Circulation ; 145(25): 1829-1838, 2022 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-35369700

RESUMO

BACKGROUND: Optimal timing for catheter ablation of ventricular tachycardia is an important unresolved issue. There are no randomized trials evaluating the benefit of ablation after the first implantable cardioverter defibrillator (ICD) shock. METHODS: We conducted a 2-phase, prospective, multicenter, randomized clinical trial. Patients with ischemic or nonischemic dilated cardiomyopathy and primary or secondary prevention indication for ICD were enrolled in an initial observational phase until first appropriate shock (phase A). After reconsenting, patients were randomly assigned 1:1 in phase B to immediate ablation (within 2 months from shock delivery) or continuation of standard therapy. The primary end point was a composite of death from any cause or hospitalization for worsening heart failure. Amiodarone intake was not allowed except for documented atrial tachyarrhythmias. On July 23, 2021, phase B of the trial was interrupted as a result of the first interim analysis on the basis of the Bayesian adaptive design. RESULTS: Of the 517 patients enrolled in phase A, 154 (30%) had ventricular tachycardia, 56 (11%) received an appropriate shock over a median follow-up of 2.4 years (interquartile range, 1.4-4.4), and 47 of 56 (84%) agreed to participate in phase B. After 24.2 (8.5-24.4) months, the primary end point occurred in 1 of 23 (4%) patients in the ablation group and 10 of 24 (42%) patients in the control group (hazard ratio, 0.11 [95% CI, 0.01-0.85]; P=0.034). The results met the prespecified termination criterion of >99% Bayesian posterior probability of superiority of treatment over standard therapy. No deaths were observed in the ablation group versus 8 deaths (33%) in the control group (P=0.004); there was 1 worsening heart failure hospitalization in the ablation group (4%) versus 4 in the control group (17%; P=0.159). ICD shocks were less frequent in the ablation group (9%) than in the control group (42%; P=0.039). CONCLUSIONS: Ventricular tachycardia ablation after first appropriate shock was associated with a reduced risk of the combined death or worsening heart failure hospitalization end point, lower mortality, and fewer ICD shocks. These findings provide support for considering ventricular tachycardia ablation after the first ICD shock. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01547208.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Teorema de Bayes , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/terapia , Humanos , Prognóstico , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 34(1): 99-107, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36335638

RESUMO

OBJECTIVES: Pulsed electric field (PEF) therapies employ punctuated energy delivery to kill cells in a volume of tissue through mechanisms that are not dependent on thermal processes. A key component to successful cardiac ablation procedures is ensuring the generation of transmural, contiguous ablation zones, which requires in-depth knowledge regarding treatment sizes for a given therapeutic application. METHODS: In this study, a series of acute treatments were delivered to porcine ventricles, where triphenyl tetrazolium chloride (TTC) vitality stain was used to identify treatment effect sizes for the three focal monopolar CENTAURI PEF cardiac ablation energy settings. RESULTS: Treatment depths were 5.7, 7.2, and 8.2 mm for the 19, 22, and 25 A energy settings, respectively. Gross pathology indicated umbral zones of hemorrhage surrounded by pale avital TTC-negative-negative tissue, which contrasted significantly from radiofrequency ablation (RF) controls. Histologically, treatment zones are identified by regions of contraction band necrosis and cardiomyocytolysis, which contrasted with RF control lesions composed primarily of coagulation necrosis. CONCLUSIONS: Together, these data indicate the ability for focal monopolar PEF treatments to generate deep treatment zones in cardiac ablation without incurring the gross or histological coagulative characteristics of RF thermal lesions.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Necrose , Catéteres , Ventrículos do Coração
6.
J Cardiovasc Electrophysiol ; 34(1): 82-89, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36321661

RESUMO

INTRODUCTION: Aim of this study was to evaluate the incidence of ablation-induced endoscopically detected esophageal lesions (EDEL) and gastroparesis in patients undergoing high-power short-duration (HPSD) atrial fibrillation (AF) ablation using different target ablation index (AI) values. METHODS AND RESULTS: Consecutive patients undergoing AF ablation were included. Radiofrequency (RF) ablation was performed using HPSD ablation (50 W, target AI of 320 and 350 (group 1) and 380 (group 2) at posterior wall). Postablation endoscopy was performed in all patients. In total, 233 patients (66.8 ± 10 years; 52% male) were included consecutively (n = 137 patients in group 1 and n = 96 patients in group 2). Mean AI values und RF time at posterior wall was significantly higher and longer in group 2 compared to group 1 patients (413 ± 9 vs. 392 ± 19 AI, p < 0.01; 9.0 ± 0.8 s vs. 7.8 ± 0.7 s, p < 0.01). Esophageal endoscopy revealed esophageal lesions or gastroparesis in 43 of 233 patients (18.5%) in the total cohort (13.1% in group 1 and 26.0% in group 2; p = 0.02). Incidence of EDEL was 8.0% and 13.5% in group 1 and group 2, respectively. According to logistic analysis incidence of EDEL and/or gastroparesis was significantly lower in patients with a higher body mass index and higher in group 2 patients compared to group 1 patients. CONCLUSION: The incidence of EDEL or gastroparesis in patients undergoing HPSD AF ablation was 18.5% in the total cohort. The risk of EDEL and gastroparesis was associated with a higher AI target value of 380 compared to 320 and 350 at posterior wall and was reversely associated with body mass index.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Gastroparesia , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Incidência , Gastroparesia/diagnóstico , Gastroparesia/epidemiologia , Gastroparesia/etiologia , Esôfago/diagnóstico por imagem , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
Europace ; 25(4): 1379-1391, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36881791

RESUMO

AIMS: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427-16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. CONCLUSION: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Seguimentos , Resultado do Tratamento , Esôfago/cirurgia , Inteligência Artificial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
8.
Europace ; 25(1): 199-210, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36753478

RESUMO

To develop a suite of quality indicators (QIs) for the management of patients with ventricular arrhythmias (VA) and the prevention of sudden cardiac death (SCD). The Working Group comprised experts in heart rhythm management including Task Force members of the 2022 European Society of Cardiology (ESC) Clinical Practice Guidelines for the management of patients with VA and the prevention of SCD, members of the European Heart Rhythm Association, international experts, and a patient representative. We followed the ESC methodology for QI development, which involves (i) the identification of the key domains of care for the management of patients with VA and the prevention of SCD by constructing a conceptual framework of care, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. We identified eight domains of care for the management of patients with VA and the prevention of SCD: (i) structural framework, (ii) screening and diagnosis, (iii) risk stratification, (iv) patient education and lifestyle modification, (v) pharmacological treatment, (vi) device therapy, (vii) catheter ablation, and (viii) outcomes, which included 17 main and 4 secondary QIs across these domains. Following a standardized methodology, we developed 21 QIs for the management of patients with VA and the prevention of SCD. The implementation of these QIs will improve the care and outcomes of patients with VA and contribute to the prevention of SCD.


Assuntos
Cardiologia , Indicadores de Qualidade em Assistência à Saúde , Humanos , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle
9.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208301

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Assuntos
Monitorização Fisiológica , Telemetria , Humanos
10.
J Cardiovasc Electrophysiol ; 33(7): 1596-1598, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35612359

RESUMO

It has been shown that endocardial occlusion of the left atrial appendage (LAA) is equally effective in preventing embolic events compared to oral anticoagulation in patients with nonvalvular atrial fibrillation. An 82-year-old female patient was admitted for LAA occlusion for repetitive GI bleeding. She had high CHADSVASC Score and HASBLED with long persistent atrial fibrillation with many comorbities. The preprocedural transesophageal echo revealed a great mass in the left atrium (Picture 1). Cardiac surgery was denied, we performed an epicardial only ligation for closing the LAA. For this approach we performed an epicardial puncture and contrast injection within the pericardial space to delineate the LAA. An epicardial wire with a suction mechanism at its distal end was attached to the anterior lobe of the LAA. Using this epicardial wire the snare could be advanced over the appendage and closed down. Complete exclusion of the LAA was achieved. There were no procedural complications and the patient is doing well after 3 months.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Ligadura , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 33(10): 2174-2180, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35938384

RESUMO

INTRODUCTION: To investigate whether the current standard voltage cut-off of <0.5 for dense scar definition on endocardial bipolar voltage mapping (EBVM), using a high-resolution multipoint mapping catheter with microelectrodes (HRMMC), correctly identifies the actual scar area described on CT with myocardial thinning (CT MT). METHODS: Forty patients (39 men; 67.0 ± 9.0 y/o) with a history of transmural myocardial infarction (mean time interval since MI 15.0 ± 7.9 years) and sustained ventricular tachycardia (VT) were consecutively enrolled. A CT MT was performed in each patient before VT ablation. The CT MT 3D anatomical model, including MT layers, was merged with the 3D electroanatomical and EBVM. Different predefined cut-off settings for scar definition on EBVM were used to identify the optimal ones, which showed the best overlap in terms of scar area with the different MT layers. RESULTS: A cut-off value of <0.2 mV demonstrated the best correlation in terms of scar area with the 2 mm thinning on CT MT (p = .04) and a cut-off of <1 mV best overlapped with the 5 mm thinning (p = .003). The currently used <0.5 mV cut-off for scar definition on EBVM proved to be the best area correlation with 3 mm thinning (p = .0002). CONCLUSION: In order to better identify the real extent of scar areas after transmural MI as described on preprocedural CT MT, higher cut-off values for scar definition should be applied if the EBVM is performed using a HRMMC.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Catéteres , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Endocárdio , Humanos , Masculino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Tomografia Computadorizada por Raios X
12.
J Cardiovasc Electrophysiol ; 33(7): 1425-1434, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35441414

RESUMO

INTRODUCTION: Data about atrial fibrillation (AF) ablation using high-power short duration (HPSD) radiofrequency ablation in the elderly population is still scarce. The aim of our study was to investigate the efficacy and safety of HPSD ablation in patients over 75 years compared to younger patients. METHODS: Consecutive patients older than 75 years with paroxysmal or persistent AF undergoing a first-time AF ablation using 50 W HPSD ablation approach were analyzed in this retrospective observational analysis and compared to a control group <75 years. Short-term endpoints included intraprocedural reconnection of at least one pulmonary vein (PV) and intrahospital and AF recurrence during 3 months blanking period, as well as a long-term endpoint of freedom from atrial arrhythmias of antiarrhythmic drugs after 12 months. RESULTS: A total of 540 patients underwent a first AF ablation with HPSD (66 ± 10 years; 58% male; 47% paroxysmal AF). Mean age was 78 ± 2.4 and 63 ± 6.3 years (p < .001), respectively. Elderly patients were significantly more often women (p < .001). The procedure, fluoroscopy, and ablation were comparable. Elderly patients revealed significantly more often extra-PV low-voltage areas requiring additional left atrial ablations (p < .001). Overall complication rates were low; however, elderly patients revealed higher major complication rates mainly due to unmasking sick sinus syndrome (p = .003). Freedom from arrhythmia recurrences was comparable (68% vs. 76%, log-rank p = .087). Only in the subgroup of paroxysmal AF, AF recurrences were more common after 12 months (69% vs. 82%; log-rank p = .040; hazard ratio: 1.462, p = .044) in the elderly patients. In multivariable Cox regression analysis of the whole cohort persistent AF, female gender, diabetes mellitus and presence of left atrium low-voltage areas, but not age >75 years were associated with AF recurrences. CONCLUSION: HPSD AF ablation of patients >75 years in experienced centers is safe and effective. Therefore, age alone should not be the reason to withhold AF ablation from vital elderly patients due to only a slightly worse outcome and safety profile. In paroxysmal AF, elderly patients have more recurrences compared to the younger control group.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 33(5): 920-927, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233883

RESUMO

INTRODUCTION: High power short duration (HPSD) ablation proved to be an effective and safe ablation technique for atrial fibrillation (AF). In former case series, a significant amount of postablation coagulation at the catheter tip as well as silent cerebral lesions (SCL) in postprocedural cerebral magnetic resonance (cMRI) have been identified in patients undergoing de-novo AF ablations with very high power 90 W short duration (vHPvSD) ablations using the QDot ablation catheter in combination with a novel RF generator (nGEN, Biosense Webster). Therefore, the RF generator software has been recently modified. METHODS AND RESULTS: Consecutive patients undergoing a first AF ablation including pulmonary vein isolation (PVI) with vHPvSD (90 W, with a predefined ablation time of 3 s at posterior left atrium (LA) wall sites and 4 s at other ablation sites) using the QDOT Micro ablation catheter (Biosense Webster) in conjunction with the technically modified nGEN RF generator (software V1c; Biosense Webster) were included. Procedural characteristics including first-pass isolation per pulmonary vein (PV) pair and early reconnection location within the 30-min waiting period were recorded. In all patients postablation endoscopy to document any thermal esophageal injury (EDEL) and in eligible patients a cMRI to detect silent cerebral events (SCEs)/lesions were performed. All acute procedure-related complications were recorded during the time until hospital discharge. Furthermore, short-term and midterm success after 3 and 6-12 months of follow-up was investigated. In total, 34 consecutive patients (67 ± 9 years; 62% male; 68% paroxysmal AF) were included. First-pass isolation of all PVs was achieved in 6/34 (18%) patients. First-pass isolation was seen in 37/68 (54%) of PV pairs. Early reconnection occurred in 11 (32%) patients (including reconnections at posterior LA wall sites n = 6 and at nonposterior sites n = 5). No patient had an EDEL (0%). In 6/23 (26%) patients undergoing postablation cerebral MRI SCEs were identified. In six patients, coagulation on the catheter tip was detected at the end of the procedure. No further peri- or postprocedural complications were detected. Early AF recurrence before discharge was seen in 1/34 (3%) of the patients included in this study. Within 3 months 10/34 (29%) revealed AF recurrence during blanking period. After a mean follow-up of 7 months, 31/34 (88%) patients revealed sinus rhythm. CONCLUSION: AF ablation using 90 W vHPvSD with a specialized ablation catheter in conjunction with a recently modified RF generator was associated with no EDEL in the whole study cohort and 26% SCEs in a subgroup of patients undergoing acute postablation cerebral MRI. Accordingly, to our previously published results, a relevant number of catheter tip coagulations was identified in this patient cohort even after modifications of the RF generator. The vHPvSD ablation technique using the present and the previous generator seems to be associated with a very low rate of esophageal injury. However, the recently revised generator software also produced a relevant number of catheter tip coagulum formation and SCEs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago , Feminino , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 33(12): 2504-2513, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36124396

RESUMO

BACKGROUND: This study sought to evaluate the short and midterm efficacy and safety of the novel very high power very short duration (vHPvSD) 90 W approach compared to HPSD 50 W for atrial fibrillation (AF) ablation as well as reconnection patterns of 90 W ablations. METHODS AND RESULTS: Consecutive patients undergoing first AF ablation with vHPvSD (90 W; predefined ablation time of 3 s for posterior wall ablation and 4 s for anterior wall ablation) were compared to patients using HPSD (50 W; ablation index-guided; AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) retrospectively. A total of 84 patients (67.1 ± 9.8 years; 58% male; 47% paroxysmal AF) were included (42 with 90 W, 42 with 50 W) out of a propensity score-matched cohort. 90 W ablations revealed shorter ablation times (10.5 ± 6.7 min vs. 17.4 ± 9.9 min; p = .001). No major complication occurred. 90 W ablations revealed lower first pass PVI rates (40% vs. 62%; p = .049) and higher AF recurrences during blanking period (38% vs. 12%; p = .007). After 12 months, both ablation approaches revealed comparable midterm outcomes (62% vs. 70%; log-rank p = .452). In a multivariable Cox regression model, persistent AF (hazard ratio [HR]: 1.442, 95% confidence interval [CI]: 1.035-2.010, p = .031) and increased procedural duration (HR: 1.011, 95% CI: 1.005-1.017, p = .001) were identified as independent predictors of AF recurrence during follow-up. CONCLUSIONS: AF ablation using 90 W vHPvSD reveals a similar safety profile compared to 50 W ablation with shorter ablation times. However, vHPvSD ablation was associated with lower rates of first-pass isolations and increased AF recurrences during the blanking period. After 12 months, 90 W revealed comparable efficacy results to 50 W ablations in a nonrandomized, propensity-matched comparison.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Recidiva , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
Europace ; 24(6): 928-937, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35134155

RESUMO

AIMS: Pulmonary vein isolation (PVI) using radiofrequency (RF) ablation is an effective treatment option for patients with atrial fibrillation (AF). This study aims to investigate the safety of high-power short duration (HPSD) with emphasis on oesophageal lesions after PVI. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index (AI)-guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) using the ThermoCool SmartTouch SF catheter were included. Patients underwent post-ablation oesophageal endoscopy to detect and categorize thermal oesophageal injury (EDEL). Occurrence and risk factors of oesophageal lesions and perforating complications were analysed. A total of 1033 patients underwent AF ablation with HPSD. Of them, 953 patients (67.6 ± 9.6 years; 58% male; 43% paroxysmal AF; 68% first PVI) underwent post-procedural oesophageal endoscopy and were included in further analyses. Median procedure time was 82.8 ± 24.4 min with ablation times of 16.1 ± 9.2 min. Thermal oesophageal injury was detected in 58 patients (6%) (n = 29 Category 1 erosion, n = 29 Category 2 ulcerous). One patient developed oesophageal perforation (redo, 4th AF ablation). No patient died. Using multivariable regression models, increased total ablation time [odds ratio (OR) 1.029, P = 0.010] and history of stroke (OR 2.619, P = 0.033) were associated with increased incidence of EDEL after AF ablation, whereas increased body mass index was protective (OR 0.980, P = 0.022). CONCLUSION: Thermal oesophageal lesions occur in 6% of HPSD AF ablations. The risk for development of perforating complications seems to be low. Incidence of atrio-oesophageal fistula (0.1%) is comparable to other reported series about RF ablation approaches.


Assuntos
Fibrilação Atrial , Queimaduras , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Queimaduras/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esofagoscopia/efeitos adversos , Esôfago/lesões , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
16.
Europace ; 24(12): 1909-1916, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35851917

RESUMO

AIMS: Left atrial ablation using radiofrequency (RF) is associated with endoscopically detected thermal oesophageal lesions (EDELs). The aim of this study was to compare EDEL occurrence after conventional contact force-guided (CFG) RF ablation vs. an ablation index-guided (AIG) approach in clinical routine of voltage-guided ablation (VGA). Predictors of EDEL were also assessed. METHODS AND RESULTS: This study compared CFG (n = 100) with AIG (n = 100) in consecutive atrial fibrillation ablation procedures, in which both pulmonary vein isolation and VGA were performed. In the AIG group, AI targets were ≥500 anteriorly and ≥350-400 posteriorly. Upper endoscopy was performed after ablation.The CFG and AIG groups had comparable baseline characteristics. The EDEL occurred in 6 and 5% (P = 0.86) in the CFG and AIG groups, respectively. Category 2 lesions occurred in 4 and 2% (P = 0.68), respectively. All EDEL healed under proton pump inhibitor therapy. The AI > 520 was the only predictor of EDEL [odds ratio (OR) 3.84; P = 0.039]. The more extensive Category 2 lesions were predicted by: AI max > 520 during posterior ablation (OR 7.05; P = 0.042), application of posterior or roof lines (OR 5.19; P = 0.039), existence of cardiomyopathy (OR 4.93; P = 0.047), and CHA2DS2-VASc score (OR 1.71; P = 0.044). The only Category 2 lesion with AI max < 520 (467) occurred in a patient with low body mass index. CONCLUSIONS: Both methods were comparable with respect to clinical complications and EDEL. In consideration of previous reconnection data and our study results regarding oesophageal safety, optimal AI target range might be between 400 and 450.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Esôfago , Átrios do Coração/cirurgia , Resultado do Tratamento , Recidiva
17.
Europace ; 24(9): 1372-1383, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35640917

RESUMO

Digital technology is now an integral part of medicine. Tools for detecting, screening, diagnosis, and monitoring health-related parameters have improved patient care and enabled individuals to identify issues leading to better management of their own health. Wearable technologies have integrated sensors and can measure physical activity, heart rate and rhythm, and glucose and electrolytes. For individuals at risk, wearables or other devices may be useful for early detection of atrial fibrillation or sub-clinical states of cardiovascular disease, disease management of cardiovascular diseases such as hypertension and heart failure, and lifestyle modification. Health data are available from a multitude of sources, namely clinical, laboratory and imaging data, genetic profiles, wearables, implantable devices, patient-generated measurements, and social and environmental data. Artificial intelligence is needed to efficiently extract value from this constantly increasing volume and variety of data and to help in its interpretation. Indeed, it is not the acquisition of digital information, but rather the smart handling and analysis that is challenging. There are multiple stakeholder groups involved in the development and effective implementation of digital tools. While the needs of these groups may vary, they also have many commonalities, including the following: a desire for data privacy and security; the need for understandable, trustworthy, and transparent systems; standardized processes for regulatory and reimbursement assessments; and better ways of rapidly assessing value.


Assuntos
Cardiologia , Doenças Cardiovasculares , Insuficiência Cardíaca , Telemedicina , Dispositivos Eletrônicos Vestíveis , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Inteligência Artificial , Glucose , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos
18.
Europace ; 24(3): 400-405, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34757432

RESUMO

AIMS: Very high-power short-duration (vHPSD) via temperature-controlled ablation (TCA) is a new modality to perform radiofrequency pulmonary vein isolation (PVI), conceivably at the cost of a narrower safety margin towards the oesophagus. In this two-centre trial, we aimed to determine the safety of vHPSD-based PVI with specific emphasis on silent oesophageal injury. METHODS AND RESULTS: Ninety consecutive patients with atrial fibrillation (AF) underwent vHPSD-PVI (90 W, 3-4 s, TCA) using the QDOT MICRO catheter, in conjunction with the nGEN (Bad Neustadt, n = 45) or nMARQ generator (Bruges, n = 45). All patients underwent post-ablation oesophageal endoscopy. Procedural parameters and complications were recorded. A subgroup of 21 patients from Bad Neustadt underwent cerebral magnetic resonance imaging (cMRI) to detect silent cerebral events (SCEs). Mean age was 67 ± 9 years, 59% patients were male, and 66% patients had paroxysmal AF. Pulmonary vein isolation was obtained in all cases after 96 ± 29 min. No steam pop, cardiac tamponade, stroke, or fistula was reported. None of the 90 patients demonstrated oesophageal ulceration (0%). Charring was not observed in the nMARQ cohort (0% vs. 11% in the nGEN group). In 5 out of 21 patients (24%), cMRI demonstrated SCE (exclusively nGEN cohort). CONCLUSION: Temperature-controlled vHPSD catheter ablation allows straightforward PVI without evidence of oesophageal ulcerations or symptomatic complications. Catheter tip charring and silent cerebral lesions when using the nGEN generator have led to further modification.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Ablação por Radiofrequência , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Esôfago/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Resultado do Tratamento
19.
Europace ; 24(6): 959-969, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34922350

RESUMO

AIMS: Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. METHODS AND RESULTS: (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. CONCLUSION: Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Animais , Ablação por Cateter/métodos , Estudos Retrospectivos , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
20.
Europace ; 24(2): 313-330, 2022 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-34878119

RESUMO

We aim to provide a critical appraisal of basic concepts underlying signal recording and processing technologies applied for (i) atrial fibrillation (AF) mapping to unravel AF mechanisms and/or identifying target sites for AF therapy and (ii) AF detection, to optimize usage of technologies, stimulate research aimed at closing knowledge gaps, and developing ideal AF recording and processing technologies. Recording and processing techniques for assessment of electrical activity during AF essential for diagnosis and guiding ablative therapy including body surface electrocardiograms (ECG) and endo- or epicardial electrograms (EGM) are evaluated. Discussion of (i) differences in uni-, bi-, and multi-polar (omnipolar/Laplacian) recording modes, (ii) impact of recording technologies on EGM morphology, (iii) global or local mapping using various types of EGM involving signal processing techniques including isochronal-, voltage- fractionation-, dipole density-, and rotor mapping, enabling derivation of parameters like atrial rate, entropy, conduction velocity/direction, (iv) value of epicardial and optical mapping, (v) AF detection by cardiac implantable electronic devices containing various detection algorithms applicable to stored EGMs, (vi) contribution of machine learning (ML) to further improvement of signals processing technologies. Recording and processing of EGM (or ECG) are the cornerstones of (body surface) mapping of AF. Currently available AF recording and processing technologies are mainly restricted to specific applications or have technological limitations. Improvements in AF mapping by obtaining highest fidelity source signals (e.g. catheter-electrode combinations) for signal processing (e.g. filtering, digitization, and noise elimination) is of utmost importance. Novel acquisition instruments (multi-polar catheters combined with improved physical modelling and ML techniques) will enable enhanced and automated interpretation of EGM recordings in the near future.


Assuntos
Fibrilação Atrial , Cardiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Mapeamento Potencial de Superfície Corporal , Átrios do Coração , Humanos , América Latina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA