Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Extra Corpor Technol ; 43(2): 70-4, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21848175

RESUMO

In April 2009, novel H1N1 influenza A pneumonia was initially identified in young adults by the Mexican Health Ministry. Previously healthy patients progressing to multisystem organ failure were common. Worldwide, hospitals reported surges in intensive care admissions during the initial phase of the pandemic. In patients with H1N1 pneumonia refractory to mechanical ventilation, centers were initially reporting low survival rates despite the use of extracorporeal membrane oxygenation (ECMO). The initial poor outcomes and protracted ECMO treatment epochs resulted in centers limiting or withholding the use of ECMO in this population. With respect to children with H1N1 infection there was uncertainty concerning optimal incorporation of ECMO as a therapeutic option. In children with rapidly progressive pneumonia and hypoxia refractory to mechanical ventilation, venovenous (VV) ECMO has been successfully used with survival ranging from 40-60% depending on the etiology. We report the successful use of VV ECMO in two children with confirmed novel H1N1 complicated by bacterial pneumonia or morbid obesity. Our Institutional Review Board waived the need for consent. Prompt initiation of VV ECMO resulted in rapid clinical improvement, radiographic resolution of diffuse consolidation, and return of full neurocognitive function. For children with rapidly progressive respiratory distress on conventional ventilation, VV ECMO can be used to improve outcomes when initiated early in the disease process even in children with a significant co-morbidity.


Assuntos
Oxigenação por Membrana Extracorpórea , Vírus da Influenza A Subtipo H1N1 , Influenza Humana/terapia , Influenza Humana/virologia , Pneumonia Viral/terapia , Pneumonia Viral/virologia , Respiração Artificial , Criança , Oxigenação por Membrana Extracorpórea/instrumentação , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Humanos , Masculino , Oximetria , Adulto Jovem
2.
J Extra Corpor Technol ; 36(4): 364-7, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15679280

RESUMO

The Terumo Baby-RX, a new-generation low prime oxygenator, recently has entered the perfusion market in North America. This oxygenator is designed exclusively for neonates and infants and has the smallest priming volume of any clinically available oxygenator. The BABY-RX also is treated with X Coating, Terumo's biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The oxygenator has a blood flow range of 0.1 to 1500 mL/min and operates with a minimum reservoir volume of 15 mL. A 3.2-kg patient, status post-Stage 1 Norwood, Palliation was placed on cardiopulmonary support after thrombus formation within the modified Blalock-Taussig shunt during a general surgery procedure. The extended support circuit incorporated the Baby-RX oxygenator for 17.5 hours. The oxygenator performed well over this time period at flows of 600-800 mL/min, sweep rates of 100-300 mL/min, FiO2 of 30-40%, and ACTs of 140-200 seconds. There were no indices of oxygenator failure noted within the time frame of support. After placement of a new systemic to pulmonary shunt, the patient was removed from support and the oxygenator drained of residual blood. No evidence of fiber damage or clot formation was noted. The patient had a successful support run without complications related to cardiopulmonary support.


Assuntos
Ponte Cardiopulmonar/instrumentação , Oxigenação por Membrana Extracorpórea/instrumentação , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Oxigenadores de Membrana , Gasometria , Materiais Revestidos Biocompatíveis , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Humanos , Lactente , Terapia Intensiva Neonatal , Reperfusão Miocárdica/instrumentação , Fatores de Tempo
3.
J Extra Corpor Technol ; 36(4): 324-8, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15679272

RESUMO

New technology and advances in extracorporeal bypass circuitry and surgical techniques have drastically improved outcomes in infants with congenital heart defects. Hypothermia with circulatory arrest has fallen out of favor in many institutions over the last decade in part from data implicating even short circulatory arrest times to long-term neurologic sequelae. Implementing continuous cerebral perfusion techniques for aortic arch reconstruction is desirable in ameliorating neurologic complications because long-term survival of complex defects can be more routinely achieved. Many centers have implemented alternative means of alleviating cerebral ischemic periods by incorporating selective antegrade or retrograde cerebral perfusion techniques. The incidence of post-operative neurologic events is low when alternative cerebral perfusion techniques are used. Many techniques used to perform continuous cerebral perfusion involve brief periods of circulatory arrest, usually for perfusion cannula repositioning. Herein we describe a technique for performing continuous antegrade cerebral perfusion without a need to interrupt forward flow.


Assuntos
Aorta Torácica/cirurgia , Encéfalo/irrigação sanguínea , Ponte Cardiopulmonar/métodos , Cardiopatias Congênitas/cirurgia , Perfusão/métodos , Fluxo Pulsátil , Aorta Torácica/anormalidades , Ponte Cardiopulmonar/instrumentação , Criança , Humanos , Hipotermia Induzida , Perfusão/instrumentação , Fatores de Tempo
4.
Ann Thorac Surg ; 96(5): 1721-6; discussion 1726, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23998412

RESUMO

BACKGROUND: A clinically driven transition in perfusion technique occurred at Children's Hospital and Medical Center, Omaha, Nebraska, from primarily selective cerebral perfusion bracketed by brief periods of deep hypothermic circulatory arrest to a technique of dual arterial perfusion including innominate artery and descending aortic cannulation (DAC), with continuous mildly hypothermic (>30 °C) full-flow cardiopulmonary bypass to the entire body. This study retrospectively compared outcomes in a recent cohort of neonates undergoing aortic arch reconstruction with the two techniques. METHODS: The clinical records of 142 consecutive neonates undergoing operations involving aortic arch reconstruction at a single institution between April 2004 and September 2012 were reviewed. Renal function changes were graded according to the pediatric RIFLE score (based on risk, injury, failure, loss, and end-stage kidney disease). Sixteen patients, 8 supported with selective cerebral perfusion bracketed by brief periods of deep hypothermic circulatory arrest and 8 with DAC, required immediate postoperative extracorporeal membrane oxygenation and were excluded from renal function analysis. Multivariable regression models evaluated predictors of pediatric RIFLE score. RESULTS: Patients with DAC had shorter median bypass support (113 versus 172 minutes; p < 0.001) and myocardial ischemic time (43 versus 81 minutes; p < 0.001). Patients with DAC had less median fluid gain at 24 hours (37 versus 69 mL/kg; p < 0.001), and lower incidence of acute kidney injury (5% versus 31%; p < 0.001). Fewer patients with DAC (31% versus 58%; p = 0.001) required open chest. Use of selective cerebral perfusion bracketed by brief periods of deep hypothermic circulatory arrest, single-ventricular physiology, and aortic cross-clamp time were found to be multivariable predictors of serious kidney dysfunction. CONCLUSIONS: Multisite arterial perfusion, including DAC, and maintenance of continuous mildly hypothermic full-flow cardiopulmonary bypass may offer advantages as a perfusion strategy for neonatal arch reconstruction. Prospective investigation of this technique is warranted.


Assuntos
Aorta Torácica/cirurgia , Ponte Cardiopulmonar , Parada Circulatória Induzida por Hipotermia Profunda , Rim/fisiologia , Cateterismo , Feminino , Humanos , Recém-Nascido , Masculino , Período Pós-Operatório , Estudos Retrospectivos
5.
World J Pediatr Congenit Heart Surg ; 4(4): 418-21, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24327637

RESUMO

A technique is described for exposure of the descending aorta, allowing separate arterial cannulation for perfusion of the upper and lower body during reconstruction of the aortic arch, maintaining continuous full-flow cardiopulmonary bypass to the entire body. This single technique is applicable to all aortic arch pathologies and allows an unhurried aortic reconstruction in an unobstructed field.


Assuntos
Aorta Torácica/cirurgia , Tronco Braquiocefálico/cirurgia , Ponte Cardiopulmonar/métodos , Hipotermia Induzida/métodos , Malformações Vasculares/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Aorta Torácica/anormalidades , Criança , Pré-Escolar , Humanos , Lactente , Perfusão/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA