RESUMO
BACKGROUND: To date, there are no randomized, double-blinded clinical trials comparing catheter ablation to DC cardioversion (DCCV) with medical therapy in patients with persistent atrial fibrillation (PersAF). Conducting a large-scale trial to address this question presents considerable challenges, including recruitment, blinding, and implementation. We conducted a pilot study to evaluate the feasibility of conducting a definitive placebo-controlled trial. METHODS: This prospective trial was carried out at Barts Heart Centre, United Kingdom, employing a randomized, double-blinded, placebo-controlled design. Twenty patients with PersAF (duration <2 years) were recruited, representing 10% of the proposed larger trial as determined by a power calculation. The patients were randomized in a 1:1 ratio to receive either PVI ± DCCV (PVI group) or DCCV + Placebo (DCCV group). The primary endpoint of this feasibility study was to evaluate patient blinding. Patients remained unaware of their treatment allocation until end of study. RESULTS: During the study, 35% of patients experienced recurrence of PersAF prior to completion of 12 months follow-up. Blinding was successfully maintained amongst both patients and medical staff. The DCCV group had a trend to higher recurrence and repeat procedure rate compared to the PVI group (recurrence of PersAF 60% vs 30%; p = .07 and repeat procedure 70% vs 40%; p = .4). The quality of life experienced by individuals in the PVI group showed improvement, as evidenced by enhanced scores on the AF specific questionnaire (AF PROMS) (3 [±4] vs 21 [±8]) and SF-12 mental-component raw score (51.4 [±7] vs 43.24 [±15]) in patients who maintained sinus rhythm at 12 months. CONCLUSION: This feasibility study establishes the potential for conducting a blinded, placebo-controlled trial to evaluate the efficacy of PVI versus DCCV in patients with PersAF.
Assuntos
Angina Estável , Fibrilação Atrial , Ablação por Cateter , Intervenção Coronária Percutânea , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos de Viabilidade , Qualidade de Vida , Estudos Prospectivos , Angina Estável/cirurgia , Projetos Piloto , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , RecidivaRESUMO
AIMS: Successful ventricular arrhythmia (VA) ablation requires identification of functionally critical sites during contact mapping. Estimation of the peak frequency (PF) component of the electrogram (EGM) may improve correct near-field (NF) annotation to identify circuit segments on the mapped surface. In turn, assessment of NF and far-field (FF) EGMs may delineate the three-dimensional path of a ventricular tachycardia (VT) circuit. METHODS AND RESULTS: A proprietary NF detection algorithm was applied retrospectively to scar-related re-entry VT maps and compared with manually reviewed maps employing first deflection (FDcorr) for VT activation maps and last deflection (LD) for substrate maps. Ventricular tachycardia isthmus location and characteristics mapped with FDcorr vs. NF were compared. Omnipolar low-voltage areas, late activating areas, and deceleration zones (DZ) in LD vs. NF substrate maps were compared. On substrate maps, PF estimation was compared between isthmus and bystander sites. Activation mapping with entrainment and/or VT termination with radiofrequency (RF) ablation confirmed critical sites. Eighteen patients with high-density VT activation and substrate maps (55.6% ischaemic) were included. Near-field detection correctly located critical parts of the circuit in 77.7% of the cases compared with manually reviewed VT maps as reference. In substrate maps, NF detection identified deceleration zones in 88.8% of cases, which overlapped with FDcorr VT isthmus in 72.2% compared with 83.3% overlap of DZ assessed by LD. Applied to substrate maps, PF as a stand-alone feature did not differentiate VT isthmus sites from low-voltage bystander sites. Omnipolar voltage was significantly higher at isthmus sites with longer EGM durations compared with low-voltage bystander sites. CONCLUSION: The NF algorithm may enable rapid high-density activation mapping of VT circuits in the NF of the mapped surface. Integrated assessment and combined analysis of NF and FF EGM-components could support characterization of three-dimensional VT circuits with intramural segments. For scar-related substrate mapping, PF as a stand-alone EGM feature did not enable the differentiation of functionally critical sites of the dominant VT from low-voltage bystander sites in this cohort.
Assuntos
Algoritmos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/diagnóstico , Humanos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Potenciais de Ação , Idoso , Frequência Cardíaca , Valor Preditivo dos Testes , Processamento de Sinais Assistido por ComputadorRESUMO
AIMS: The SMART Pass™ (SP) algorithm is a high-pass filter that aims to reduce inappropriate therapy (IT) in subcutaneous internal cardiac defibrillator (S-ICD), but SP can deactivate due to low amplitude sensed R waves or asystole. The association between IT and SP deactivation and management strategies were evaluated, hypothesizing SP deactivation increases the risk of IT and device re-programming, or lead/generator re-positioning could reduce this risk. METHODS AND RESULTS: Retrospective single-centre audit of Emblem™ S-ICD devices implanted 2016 to 2020 utilizing health records and remote monitoring data. Cox regression models evaluated associations between SP deactivation and IT. A total of 348 patients (27 ± 16.6 months follow-up) were studied: 73% primary prevention. Thirty-eight patients (11.8%) received 83 shocks with 27 patients (7.8%) receiving a total of 44 IT. Causes of IT were oversensing (98%) and aberrantly conducted atrial fibrillation (2%). SP deactivation occurred in 32 of 348 patients (9%) and was significantly associated with increased risk of IT (hazard ratio 5.36, 95% CI 2.37-12.13). SP deactivation was due to low amplitude R waves (94%), associated with a higher defibrillation threshold at implant and presence of arrhythmogenic right ventricular cardiomyopathy. No further IT occurred 16 ± 15.5 months after corrective interventions, with changing the sensing vector being successful in 59% of cases. CONCLUSION: To reduce the risk of IT, the cause of the SP deactivation should be investigated, and appropriate reprogramming, device, or lead modifications made. Utilizing the alert for SP deactivation and electrograms could pro-actively prevent IT.
Assuntos
Displasia Arritmogênica Ventricular Direita , Fibrilação Atrial , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Cardioversão Elétrica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Displasia Arritmogênica Ventricular Direita/terapiaRESUMO
INTRODUCTION: Ethanol ablation (EA) is an alternative option for subjects with ventricular arrhythmias (VAs) refractory to conventional medical and ablative treatment. However, data on the efficacy and safety of EA remain sparse. METHODS: A systematic literature search was conducted. The primary outcomes were 1) freedom from the targeted VA and 2) freedom from any VAs post-EA. Additional safety outcomes were also analyzed. RESULTS: Ten studies were selected accounting for a population of 174 patients (62.3 ± 12.5 years, 94% male) undergoing 185 procedures. The overall acute success rate of EA was 72.4% (confidence interval [CI95% ]: 65.6-78.4). After a mean follow-up of 11.3 ± 5.5 months, the incidence of relapse of the targeted VA was 24.4% (CI95% : 17.1-32.8), while any VAs post-EA occurred in 41.3% (CI95% : 33.7-49.1). The overall incidence of procedural complications was 14.1% (CI95% : 9.8-19.8), with pericardial complications and complete atrioventricular block being the most frequent. An anterograde transarterial approach was associated with a higher rate of VA recurrences and complications compared to a retrograde transvenous route; however, differences in the baseline population characteristics and in the targeted ventricular areas should be accounted. CONCLUSION: EA is a valuable therapeutic option for VAs refractory to conventional treatment and can result in 1-year freedom from VA recurrence in 60%-75% of the patients. However, anatomical or technical challenges preclude acute success in almost 30% of the candidates and the rate of complication is not insignificant, highlighting the importance of well-informed patient selection. The certainty of the evidence is low, and further research is necessary.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Etanol/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do TratamentoRESUMO
AIMS: Cardiac tamponade is a high morbidity complication of transseptal puncture (TSP). We examined the associations of TSP-related cardiac tamponade (TRCT) for all patients undergoing left atrial ablation at our center from 2016 to 2020. METHODS AND RESULTS: Patient and procedural variables were extracted retrospectively. Cases of cardiac tamponade were scrutinized to adjudicate TSP culpability. Adjusted multivariate analysis examined predictors of TRCT. A total of 3239 consecutive TSPs were performed; cardiac tamponade occurred in 51 patients (incidence: 1.6%) and was adjudicated as TSP-related in 35 (incidence: 1.1%; 68.6% of all tamponades). Patients of above-median age [odds ratio (OR): 2.4 (1.19-4.2), p = .006] and those undergoing re-do procedures [OR: 1.95 (1.29-3.43, p = .042] were at higher risk of TRCT. Of the operator-dependent variables, choice of transseptal needle (Endrys vs. Brockenbrough, p > .1) or puncture sheath (Swartz vs. Mullins vs. Agilis vs. Vizigo vs. Cryosheath, all p > .1) did not predict TRCT. Adjusting for operator, equipment and demographics, failure to cross the septum first pass increased TRCT risk [OR: 4.42 (2.45-8.2), p = .001], whilst top quartile operator experience [OR: 0.4 (0.17-0.85), p = .002], transoesophageal echocardiogram [TOE prevalence: 26%, OR: 0.51 (0.11-0.94), p = .023], and use of the SafeSept transseptal guidewire [OR: 0.22 (0.08-0.62), p = .001] reduced TRCT risk. An increase in transseptal guidewire use over time (2016: 15.6%, 2020: 60.2%) correlated with an annual reduction in TRCT (R2 = 0.72, p < .001) and was associated with a relative risk reduction of 70%. CONCLUSIONS: During left atrial ablation, the risk of TRCT was reduced by operator experience, TOE-guidance, and use of a transseptal guidewire, and was increased by patient age, re-do procedures, and failure to cross the septum first pass.
Assuntos
Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Tamponamento Cardíaco/diagnóstico por imagem , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Humanos , Punções/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do TratamentoRESUMO
AIM: Evaluate the novel PolarX Cryoballoon in atrial fibrillation (AF) catheter ablation through a propensity-matched comparison with the Arctic Front Advance (AFA). The aim was also to identify cryoablation metrics that are predictive of successful pulmonary vein isolation (PVI) with the PolarX Cryoballoon. METHODS AND RESULTS: This prospective multi-centre study included patients that underwent cryoablation for AF. All patients underwent PVI with reconnection assessed after a 30-min waiting period and adenosine. Safety, efficacy, and cryoablation metrics were compared between PolarX and a propensity-matched AFA cohort. Seventy patients were included with 278 veins treated. In total, 359 cryoablations were performed (1.3 ± 0.6 per vein) to achieve initial PVI with 205 (73.7%) veins isolating with a single cryoablation. Independent predictors for achieving initial PVI included temperature at 30â s [odds ratio (OR) 1.26; P = 0.003] and time to reach -40°C (OR 1.88; P < 0.001) with an optimal cut-off of ≤-38.5°C at 30â s [area under the curve (AUC) 0.79; P < 0.001] and ≤-40°C at ≤32.5â s (AUC 0.77; P < 0.001), respectively. Of the 278 veins, 46 (16.5%) veins showed acute reconnection. Temperature at 30â s (≤-39.5°C, OR 1.24; P = 0.002), nadir temperature (≤-53.5°C, OR 1.35; P = 0.003), and time to isolation (≤38.0â s, OR 1.18; P = 0.009) were independent predictors of sustained PVI. Combining two of these three targets was associated with reconnection in only 2-5% of PVs. Efficacy and safety of the PolarX Cryoballoon were comparable to AFA Cryoballoon, however, cryoablation metrics were significantly different. CONCLUSIONS: The PolarX Cryoballoon has a different cryoablation profile to AFA Cryoballoon. Prospective testing of these proposed targets in large outcomes studies is required.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Adenosina , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Benchmarking , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve implantation (TAVI). The optimum timing of PPM implantation is still unclear as conduction abnormalities evolve and a balance needs to be struck between conservative delays in the hope of conduction recovery and overutilization of pacing. This study aimed to assess the safety and efficacy of early PPM implantation, without an observation period, among TAVI patients. METHODS: This is a retrospective, observational study of 1398 TAVI patients. Clinical and pacing data were collected at baseline, 30 days and at a median of 15 (4-21) months post-TAVI. Study endpoints included PPM-related complications, pacing utilization and hospital length of stay. RESULTS: One hundred five patients (8.2%) required a PPM, of which 13 were implanted pre and 92 post-TAVI. Seventy-six percent required pacing for either second- or third-degree heart block. Time to implantation for post-TAVI PPM was 1 (0-3) day. Six patients experienced a pacing-related complication- lead displacement (n = 3), hematoma (n = 2), and device infection (n = 1). Pacing utilization defined as pacing >10% of the time or a pacing requirement at the time of the pacing check was demonstrated in 83% of patients. Multivariate analysis revealed complete heart block (CHB) was the only independent predictor of pacing utilization. Hospital length of stay for the post-TAVI PPM group was longer than the group without PPM (4 [2-8] vs. 3 [2-4] days; p < .001). CONCLUSIONS: Early PPM implantation in TAVI patients is safe and majority of patients require pacing in the short and mid-term.
Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos RetrospectivosRESUMO
AIMS: Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. METHODS AND RESULTS: Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52-0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. CONCLUSION: Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation.
Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do TratamentoRESUMO
AIMS: Optimum timing of pacemaker implantation following cardiac surgery is a clinical challenge. European and American guidelines recommend observation, to assess recovery of atrioventricular block (AVB) (up to 7 days) and sinus node (5 days to weeks) after cardiac surgery. This study aims to determine rates of cardiac implantable electronic devices (CIEDs) implants post-surgery at a high-volume tertiary centre over 3 years. Implant timing, patient characteristics and outcomes at 6 months including pacemaker utilization were assessed. METHODS AND RESULTS: All cardiac operations (n = 5950) were screened for CIED implantation following surgery, during the same admission, from 2015 to 2018. Data collection included patient, operative, and device characteristics; pacing utilization and complications at 6 months. A total of 250 (4.2%) implants occurred; 232 (3.9%) for bradycardia. Advanced age, infective endocarditis, left ventricle systolic impairment, and valve surgery were independent predictors for CIED implants (P < 0.0001). Relative risk (RR) of CIED implants and proportion of AVB increased with valve numbers operated (single-triple) vs. non-valve surgery: RR 5.4 (95% CI 3.9-7.6)-21.0 (11.4-38.9) CIEDs. Follow-up pacing utilization data were available in 91%. Significant utilization occurred in 82% and underutilization (<1% A and V paced) in 18%. There were no significant differences comparing utilization rates in early (≤day 5 post-operatively) vs. late implants (P = 0.55). CONCLUSION: Multi-valve surgery has a particularly high incidence of CIED implants (14.9% double, 25.6% triple valve). Age, left ventricle systolic impairment, endocarditis, and valve surgery were independent predictors of CIED implants. Device underutilization was infrequent and uninfluenced by implant timing. Early implantation (≤5 days) should be considered in AVB post-multi-valve surgery.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do TratamentoRESUMO
BACKGROUND: Anatomical studies demonstrate significant variation in cavotricuspid isthmus (CTI) architecture. METHODS: Thirty-eight patients underwent CTI ablation at two tertiary centers. Operators delivered 682 lesions with a target ablation index (AI) of 600 Wgs. Ablation parameters were recorded every 10-20 ms. Post hoc, Visitags were trisected according to CTI position: inferior vena cava (IVC), middle (Mid), or ventricular (V) lesions. RESULTS: There were no complications. 92.1% of patients (n = 35) remained in sinus rhythm after 14.6 ± 3.4 months. For the whole CTI, peak AI correlated with mean impedance drop (ID) (R2 = 0.89, p < .0001). However, analysis by anatomical site demonstrated a non-linear relationship Mid CTI (R2 = 0.15, p = .21). Accordingly, while mean AI was highest Mid CTI (IVC: 473.1 ± 122.1 Wgs, Mid: 539.6 ± 103.5 Wgs, V: 486.2 ± 111.8 Wgs, ANOVA p < .0001), mean ID was lower (IVC: 10.7 ± 7.5Ω, Mid: 9.0 ± 6.5Ω, V: 10.9 ± 7.3Ω, p = .011), and rate of ID was slower (IVC: 0.37 ± 0.05 Ω/s, Mid: 0.18 ± 0.08 Ω/s, V: 0.29 ± 0.06 Ω/s, p < .0001). Mean contact force was similar at all sites; however, temporal fluctuations in contact force (IVC: 19.3 ± 12.0 mg/s, Mid: 188.8 ± 92.1 mg/s, V: 102.8 ± 32.3 mg/s, p < .0001) and catheter angle (IVC: 0.42°/s, Mid: 3.4°/s, V: 0.28°/s, p < .0001) were greatest Mid CTI. Use of a long sheath attenuated these fluctuations and improved energy delivery. CONCLUSIONS: Ablation characteristics vary across the CTI. At the Mid CTI, higher AI values do not necessarily deliver more effective ablation; this may reflect localized fluctuations in catheter angle and contact force.
Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Valva Tricúspide/cirurgia , Idoso , Feminino , Humanos , MasculinoRESUMO
INTRODUCTION: Patients with hypertrophic cardiomyopathy (HCM) and atrial fibrillation (AF) require chronic anticoagulation due to high thromboembolic risk. Evidence supporting the use of non-vitamin K oral anticoagulants (NOACs) in patients with HCM remains sparse, and there are no data regarding the use of NOACs in patients with HCM undergoing catheter ablation of AF. METHODS: Observational nonrandomized study in four European centers. We aimed to investigate the safety and efficacy of NOACs compared with vitamin K antagonists (VKAs) in patients with HCM undergoing catheter ablation for AF. RESULTS: A total of 137 patients with HCM (mean age: 55.0 ± 13.4, 29.1% female) underwent 230 catheter ablations for AF (1.7 ± 1.0 per patient). A total of 55 patients (39.4%) underwent 70 procedures (30.4%) on NOAC, while the remaining were on VKA. Warfarin (97.6%) and rivaroxaban (56.4%) were the most frequently used agents in the respective groups. No procedure-related deaths were reported. We observed no significant difference in the rate of thromboembolism (VKA: 0.6%; NOAC: 0%; p = 1.0) or minor bleeding (VKA: 0.6%; NOAC: 1.4%; p = .54). There was a nonsignificant trend towards a lower incidence of major bleeding (VKA: 6.9%; NOAC: 1.4%; p = .09). CONCLUSION: These preliminary data suggest that NOACs are at least as safe and effective as VKAs in patients with HCM undergoing catheter ablation for AF.
Assuntos
Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vitamina KRESUMO
AIMS: Differences of action potential duration (APD) in regions of myocardial scar and their borderzones are poorly defined in the intact human heart. Heterogeneities in APD may play an important role in the generation of ventricular tachycardia (VT) by creating regions of functional block. We aimed to investigate the transmural and planar differences of APD in patients admitted for VT ablation. METHODS AND RESULTS: Six patients (median age 53 years, five male); (median ejection fraction 35%), were studied. Endocardial (Endo) and epicardial (Epi) 3D electroanatomic mapping was performed. A bipolar voltage of <0.5 mV was defined as dense scar, 0.5-1.5 mV as scar borderzone, and >1.5 mV as normal. Decapolar catheters were positioned transmurally across the scar borderzone to assess differences of APD and repolarization time (RT) during restitution pacing from Endo and Epi. Epi APD was 173 ms in normal tissue vs. 187 ms at scar borderzone and 210 ms in dense scar (P < 0.001). Endocardial APD was 210 ms in normal tissue vs. 222 ms in the scar borderzone and 238 ms in dense scar (P < 0.01). This resulted in significant transmural RT dispersion (ΔRT 22 ms across dense transmural scar vs. 5 ms in normal transmural tissue, P < 0.001), dependent on the scar characteristics in the Endo and Epi, and the pacing site. CONCLUSION: Areas of myocardial scar have prolonged APD compared with normal tissue. Heterogeneity of regional transmural and planar APD result in localized dispersion of repolarization, which may play an important role in initiating VT.
Assuntos
Potenciais de Ação , Ablação por Cateter , Cicatriz/fisiopatologia , Endocárdio/fisiopatologia , Pericárdio/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatias/complicações , Cicatriz/etiologia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Miocardite/complicações , Miocárdio , Recidiva , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de TempoRESUMO
BACKGROUND: Transseptal puncture (TSP) is commonly performed under fluoroscopic guidance in left atrial ablation procedures. This exposes patients and healthcare professionals to deleterious ionizing radiation. We describe a novel technique for performing TSP non-fluoroscopically using a three-dimensional (3D) mapping system only. The safety and efficacy of this technique is compared to traditional fluoroscopy guided TSP. METHODS: Retrospective, single-center study of patients undergoing TSP for left atrial ablation. Those undergoing TSP using 3D mapping system alone (nonfluoroscopy group) were compared to those undergoing fluoroscopic guided TSP (Fluoroscopy group). Clinical, procedural data and complications were analyzed from a prospective registry. RESULTS: Twenty patients (32 TSPs) in the nonfluoroscopy (NF) group were compared to 14 patients (25 TSPs) in fluoroscopy (F) group. TSP success rates were similar across the groups (88% vs 96% in the NF and F groups, P = 0.97). In the NF group, there was one cardiac tamponade, two unsuccessful TSPs (previous cardiac surgery-required TOE guided TSP), and one patient required fluoroscopy on a background of CRTD device to avoid lead displacement. The mean fluoroscopy time and dose were significantly lower in the nonfluoroscopy group (0.75 ± 0.50 vs 5.32 ± 3.23 min, P < 0.001; 92.5 ± 60.7 vs 394.3 ± 182.7 cGy/cm2 , P < 0.001). CONCLUSION: Our study shows that TSPs can be performed safely and effectively using this non-fluoroscopic novel technique in a select group of patients. Radiation exposure is reduced significantly without compromising patient safety. Larger studies are required to substantiate these results. Patients with cardiac implantable devices and previous cardiac surgery may pose a challenge to using this technique.
Assuntos
Fibrilação Atrial/cirurgia , Septo Interatrial/cirurgia , Ablação por Cateter/métodos , Mapeamento Epicárdico/métodos , Punções , Estudos de Casos e Controles , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Exposição à Radiação , Estudos RetrospectivosRESUMO
OBJECTIVES: To evaluate utility of Doppler echocardiography in the assessment of left ventricular (LV) mid-cavity obstructive (LVMCO) hypertrophic cardiomyopathy (HCM). BACKGROUND: LVMCO is a relatively under-diagnosed complication of HCM and may occur alone or in combination with LV outflow tract obstruction (LVOTO). Identifying and quantifying LVMCO and differentiating it from LVOTO has important implications for patient management. We aimed to assess diagnostic performance of Doppler echocardiography in the assessment of suspected LV obstruction. METHODS: Forty symptomatic HCM patients with suspected obstruction underwent cardiac catheterization, and comparison of location and magnitude of Doppler derived gradients with synchronous invasive measurements (reference standard), at rest and isoprenaline stress (IS). RESULTS: Doppler's diagnostic accuracy for any obstruction (≥30 mmHg) in this cohort was 75% with false positive and false negative rates of 2.5 and 22.5%, respectively. During subanalysis, Doppler's diagnostic accuracy for isolated LVOTO in this selected cohort is 83% with false positive and false negative rates of 4 and 12.5%, respectively. For LVMCO, the accuracy is only 50%, with false positive and false negative rates of 10 and 40%, respectively. Doppler gradients for isolated LVOTO were similar to invasive: 85 ± 51 and 87 ± 35 mmHg, respectively (P = 0.77). Doppler gradients in LVMCO were consistently lower than invasive: 45 ± 38 and 81 ± 31 mmHg, respectively (P = 0.0002). Mid-systolic flow cessation and/or contamination of spectral signals were identified as causes of Doppler-derived inaccuracies. CONCLUSIONS: Doppler echocardiography under-diagnoses and underestimates severity of LVMCO in symptomatic HCM patients. Recognition of abrupt mid-systolic flow cessation and invasive measurements may improve detection of LVMCO in HCM.
Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Doppler em Cores , Ecocardiografia sob Estresse/métodos , Função Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Agonistas Adrenérgicos beta/administração & dosagem , Adulto , Idoso , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica/epidemiologia , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos Transversais , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Isoproterenol/administração & dosagem , Londres/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Obstrução do Fluxo Ventricular Externo/epidemiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologiaRESUMO
Aims: Endocardial left ventricular (LV) pacing is a viable alternative in patients with failed coronary sinus (CS) lead implantation. However, long-term thrombo-embolic risk remains unknown. Much of the data have come from a small number of centres. We examined the safety and efficacy of endocardial LV pacing to determine the long-term thrombo-embolic risk. Methods and results: Registries from four UK centres were combined to include 68 patients with endocardial leads with a mean follow-up of 20 months. These were compared to a matched 1:2 control group with conventional CS leads. Medical records were reviewed, and patients contacted for follow-up. Ischaemic stroke occurred in four patients (6%) in the endocardial arm providing an annual event rate (AER) of 3.6% over a 20 month follow-up; compared to 9 patients (6.6%) amongst controls with an AER of 3.4% over a 23-month follow-up. Regression analyses showed a significant association between sub-therapeutic international normalized ratio and stroke (P = 0.0001) in the endocardial arm. There was no association between lead material and mode of delivery (transatrial/transventricular) and stroke. Mortality rate was 12 and 15 per 100 patient years in the endocardial and control arm respectively with end-stage heart failure being the commonest cause. Conclusion: Endocardial LV lead in heart failure patients has a good success rate at 1.6 year follow-up. However, it is associated with a thrombo-embolic risk (which is not different from conventional CS leads) attributable to sub-therapeutic anticoagulation. Randomized control trials and studies on non-vitamin K antagonist oral anticoagulants are required to ascertain the potential of widespread clinical application of this therapeutic modality.
Assuntos
Isquemia Encefálica/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Endocárdio/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/etiologia , Função Ventricular Esquerda , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Coagulação Sanguínea/efeitos dos fármacos , Isquemia Encefálica/sangue , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/sangue , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/sangue , Tromboembolia/diagnóstico , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Reino UnidoRESUMO
BACKGROUND: Many patients undergoing ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation receive antithrombotic medications. Their uninterrupted use has the potential to affect complication rates. We assessed the incidence of complications in a large cohort of patients undergoing these procedures, according to antithrombotic medication use. METHODS: From June 2014 to June 2016, 201 VT and PVC ablations were performed at a single center. We allocated patients to three groups: (A) anticoagulation group (international normalized ratio ≥ 1.5 or non-vitamin K anticoagulant or full-dose low-molecular-weight (LMW) heparin on day of procedure); (B) antithrombotic group (antiplatelet therapy and/or prophylactic LMW heparin on day of procedure); and (C) no antithrombotics group. We assessed periprocedural complication rates in each group. Multivariable analysis was performed. RESULTS: Group A (47 patients) had 8.5% procedural complication rate: one stroke, one pseudoaneurysm, one femoral artery occlusion, and one access site hematoma. In this group, 37 patients had femoral arterial and 18 had epicardial access. In Group B (46 patients), the complication rate was 6.5%: two cardiac tamponades and one pericardial effusion without compromise. Group C (108 patients) had a 5.6% complication rate: three cardiac tamponades (with one periprocedural death and one concomitant gastric vessel injury), one pericardial effusion without compromise, one stomach perforation, and two access site hematomas. Multivariable analysis did not show any significant predictors of complications, though age approached significance. CONCLUSIONS: Complication rates were not significantly different between groups. These findings suggest that VT and PVC ablation can be performed safely in patients with uninterrupted antithrombotic medications.
Assuntos
Anticoagulantes/administração & dosagem , Ablação por Cateter/métodos , Complicações Pós-Operatórias/epidemiologia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/tratamento farmacológico , Complexos Ventriculares Prematuros/cirurgia , Idoso , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de RiscoRESUMO
BACKGROUND: Telomeres are known to provide genomic stability and telomere length has been associated with cardiovascular diseases. Moreover, a higher telomerase activity has been shown to be associated with ventricular arrhythmias (VA) in ischemic cardiomyopathy. Increasing evidence suggests that genetic variation in key telomere genes has an impact on telomerase activity. Each copy of the minor allele of SNP rs12696304, at a locus including TERC (telomerase), has been associated with â¼75 base pairs reduction in mean telomere length likely mediated by an effect on TERC expression. We investigated the impact of genetic variation of this SNP on telomerase and its association with VA in ischemic cardiomyopathy patients. METHODS AND RESULTS: Ninety ischemic cardiomyopathy patients with primary prevention implantable cardioverter defibrillators (ICDs) were recruited. Thirty-five received appropriate ICD therapy for potentially fatal VA (cases), while the remaining 55 patients did not (controls). No significant differences in baseline demographics were seen between the groups. TS was measured by qPCR, telomerase activity by TRAP assay, and SNP genotyping with Taqman probes. Telomerase was highest in C homozygous allele and had a significant association with VA in this group only (C/C,C/G,G/G; P-value 0.04, 0.33, 0.43). CONCLUSION: The present study is the first to examine the association between telomerase, a SNP at a locus including TERC, and VA in ischemic cardiomyopathy patients. Homozygosity for C-allele significantly effects telomerase expression and its association with VA in this cohort. Large-scale prospective studies are required to determine if this genetic variation predisposes patients to greater arrhythmic tendency post-MI.
Assuntos
Arritmias Cardíacas/genética , Cardiomiopatias/genética , Isquemia Miocárdica/genética , Polimorfismo de Nucleotídeo Único , Telomerase/genética , Telômero/genética , Idoso , Alelos , Arritmias Cardíacas/enzimologia , Cardiomiopatias/enzimologia , Estudos de Casos e Controles , Estudos Transversais , Desfibriladores Implantáveis , Feminino , Variação Genética , Genótipo , Humanos , Masculino , Isquemia Miocárdica/enzimologia , Reação em Cadeia da Polimerase , Estudos RetrospectivosRESUMO
BACKGROUND: Current consensus guidelines suggest direct oral anticoagulants (DOACs) are interrupted periprocedurally for catheter ablation (CA) of atrial fibrillation (AF). However, this may predispose patients to thromboembolic complications. This study investigates the safety of CA for AF on uninterrupted DOACs compared to uninterrupted warfarin. METHODS: This was a single-center, retrospective study of consecutive patients undergoing CA for AF. All patients were heparinized prior to transseptal puncture with a target-activated clotting time (ACT) of 300-350 seconds. Patients who had procedures performed on continuous DOAC were compared to those on continuous warfarin. Clinical, procedural data, and complications occurring up to 3 months were analyzed from a prospective registry with additional review of electronic health records. RESULTS: A total of 1,884 procedures were performed over 28 months: 761 (609 patients) on uninterrupted warfarin and 1,123 (900 patients) on uninterrupted DOAC (rivaroxaban 64%, apixaban 32%, and dabigatran 4%). There was no difference in the composite endpoint of death, thromboembolism, or major bleeding complication (2.2% vs 1.4%, P = 0.20). There was no difference in the complications comprising this, including tamponade, hematoma, pseudoaneurysm, and transfusion (P-values 0.28, 0.13, 0.45, and 0.36). There were no strokes, transient ischemic attacks, or other thromboembolic complications. There was no difference between groups in the proportion of tamponades requiring reversal of oral anticoagulation, the volume of blood lost, the proportion transfused, or the proportion drained percutaneously (P-values 0.50, 0.51, 0.36, and 0.38). CONCLUSION: Catheter ablation for AF can be performed safely and effectively in patients anticoagulated with DOACs and heparinized with a therapeutic ACT. There is no increased risk of periprocedural bleeding when compared to uninterrupted warfarin.
RESUMO
AIMS: Radiofrequency (RF) catheter ablation (CA) is superior to standard medical therapy in controlling recurrent ventricular tachycardia (VT). The majority of procedures have been performed in a middle-aged population. The outcome of VT ablation in the elderly has not been described. METHODS AND RESULTS: We retrospectively studied the outcome and safety of CA of VT in octogenarians performed in four European centres. The population consisted of patients presenting with recurrent VT refractory to medical therapy. Patients aged over 80 years were compared with younger patients undergoing CA. Clinical characteristics, procedural data, complications, and outcomes were examined. Implantable cardioverter-defibrillator (ICD) therapy data were collected. A total of 54 consecutive octogenarian patients underwent RF CA of VT and represented the study group (42 males, age 82.8 ± 2.7 years) compared with a control group of 104 younger patients (85 males, age 66.7 ± 8.9 years). Mean follow-up was 33 ± 48 months. Implantable cardioverter-defibrillators were present in 81 and 86% of patients, respectively (P = 0.93). Left ventricular ejection fraction was 29% ± 8.2 in octogenarians vs. 34% ± 10.2 in the younger group (P < 0.01). More major complications occurred in octogenarians (18 vs. 2%, P < 0.01). During follow-up, there were more ICD shocks in the octogenarians (28 vs. 15%, P < 0.01). The Kaplan-Meier curve of survival after VT ablation confirms comparable survival rates at 1 year, but the elderly have poor survival in the mid-term. Survival in the elderly post VT ablation is comparable with that in an age-matched cohort with ICDs but no VT storm. CONCLUSION: Octogenarians undergoing CA of VT have more risk factors, higher risk of complications and ICD shocks, but demonstrate comparable short-term survival rates.
Assuntos
Taquicardia Ventricular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Distribuição de Qui-Quadrado , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Inglaterra , Feminino , França , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Complicações Pós-Operatórias/etiologia , Pontuação de Propensão , Modelos de Riscos Proporcionais , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: Dual-site right ventricular pacing (Dual RV) has been proposed as an alternative for patients with heart failure undergoing cardiac resynchronization therapy (CRT) with a failure to deliver a coronary sinus (CS) lead. Only short-term hemodynamic and echocardiographic results of Dual RV are available. We aimed to assess the long-term results of Dual RV and its impact on survival. METHODS: Multicenter retrospective assessment of all CRT implants during a 12-year period. Patients with failed CS lead implantation, treated with Dual RV, were followed and assessed for the primary endpoint of all-cause mortality and/or heart transplant. A control group was obtained from contemporary patients using propensity matching for all available baseline variables. RESULTS: Ninety-three patients were implanted with Dual RV devices and compared with 93 matched controls. During a median of 1,273 days (interquartile range 557-2,218), intention-to-treat analysis showed that all-cause mortality and/or heart transplant was higher in the Dual RV group (adjusted hazard ratio [HR] = 1.66, 95% confidence interval [CI] 1.12-2.47, P = 0.012). As-treated analysis yielded similar results (HR = 1.97, 95% CI 1.31-2.96, P = 0.001). Cardiac device-related infections occurred seven times more frequently in the Dual RV site group (HR = 7.60, 95% CI 1.51-38.33, P = 0.014). Among Dual RV nonresponders, four had their apical leads switched off, five required an epicardial LV lead insertion, a transseptal LV lead was implanted in two, and in nine patients, after reviewing the CS venogram, a new CS lead insertion was successfully attempted. CONCLUSION: Dual RV pacing is associated with worse clinical outcomes and higher complication rates than conventional CRT.