Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
NMR Biomed ; 35(2): e4636, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34704291

RESUMO

Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle, as they are greatly involved in human daily activities. Fatty infiltration and muscle atrophy are associated with loss of strength, loss of mobility and hip disease. However, these variables have not been widely studied in this muscle group. We aimed to characterize the hip abductor muscles in a group of healthy individuals to establish reference values for volume, intramuscular fat content and shape of this muscle group. To achieve this, we executed a cross-sectional study using Dixon MRI scans of 51 healthy subjects. We used an automated segmentation method to label GMAX, GMED, GMIN and TFL muscles, measured normalized volume (NV) using lean body mass, fat fraction (FF) and lean muscle volume for each subject and computed non-parametric statistics for each variable grouped by sex and age. We measured these variables for each axial slice and created cross-sectional area and FF axial profiles for each muscle. Finally, we generated sex-specific atlases with FF statistical images. We measured median (IQR) NV values of 12.6 (10.8-13.8), 6.3 (5.6-6.7), 1.6 (1.4-1.7) and 0.8 (0.6-1.0) cm3 /kg for GMAX, GMED, GMIN and TFL, and median (IQR) FF values of 12.3 (10.1-15.9)%, 9.8 (8.6-11.2)%, 10.0 (9.0-12.0)% and 10.2 (7.8-13.5)% respectively. FF values were significantly higher for females for the four muscles (p < 0.01), but there were no significant differences between the two age groups. When comparing individual muscles, we observed a significantly higher FF in GMAX than in the other muscles. The reported novel reference values and axial profiles for volume and FF of the hip abductors, together with male and female atlases, are tools that could potentially help to quantify and detect early the deteriorating effects of hip disease or sarcopenia.


Assuntos
Tecido Adiposo/anatomia & histologia , Quadril/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/anatomia & histologia , Adolescente , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem
2.
BMC Musculoskelet Disord ; 23(1): 783, 2022 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-35974363

RESUMO

BACKGROUND: Titanium, which is known to be a highly biologically inert element, is one of the most commonly used metals in orthopaedic implants. While cobalt and chromium blood metal ion testing is routinely used in the clinical monitoring of patients with metal-on-metal hip implants, much less is known about the levels of titanium in patients with other implant types. The aim of this study was to better understand the normal ranges of blood titanium levels in patients implanted with large and sliding titanium constructs by comparison with reference levels from conventional titanium hips. METHODS: This study examined data collected from 136 patients. Over a period of 24 months, whole blood samples were collected from 41 patients implanted with large titanium implants: long (range 15 to 30 cm) spine rods with a sliding mechanism ("spine rods", n = 18), long bone tumour implants ("tumour implants", n = 13) and 3D-printed customised massive acetabular defect implants ("massive acetabular implants", n = 10). This data was compared with standard, uncemented primary titanium hip implants ("standard hips", 15 cm long) (n = 95). Clinical, imaging and blood titanium levels data were collected for all patients and compared statistically between the different groups. RESULTS: The median (range) of blood titanium levels of the standard hip, spine rods, femoral tumour implants and massive acetabular implants were 1.2 ppb (0.6-4.9), 9.7 ppb (4.0-25.4), 2.6 ppb (0.4-104.4) and 5.7 ppb (1.6-31.5) respectively. Spine rods and massive acetabular implants had significantly greater blood titanium levels compared to the standard hips group (p < 0.001). CONCLUSION: This study showed that titanium orthopaedic implants that are large and/or have a sliding mechanism have higher blood titanium levels compared to well-functioning, conventionally sized titanium hips. Reassuringly, the increased levels did not appear to induce adverse metal reactions. This study provides useful baseline data for future studies aimed at assessing blood titanium levels as a biomarker for implant function.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Cromo , Cobalto , Prótese de Quadril/efeitos adversos , Humanos , Metais , Desenho de Prótese , Titânio/efeitos adversos
3.
Skeletal Radiol ; 51(5): 971-980, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34541607

RESUMO

OBJECTIVE: To better understand the impact of long-distance running on runners' lumbar spines by assessing changes before and after their first marathon run. MATERIALS AND METHODS: The lumbar spines of 28 asymptomatic adults (14 males, 14 females, mean age: 30 years old), who registered for their first marathon, the 2019 London Richmond Marathon, were examined 16 weeks before (time point 1) and 2 weeks after (time point 2) the marathon. Participants undertook a pre-race 16-week training programme. Magnetic resonance imaging (MRI) of high-resolution 3.0 Tesla was used at each time point. Senior musculoskeletal radiologists assessed the lower lumbar spine condition. RESULTS: Out of 28 participants, 21 completed both the training and the race and 7 neither completed the training nor started the marathon but not due to spine-related issues. At time point 1, disc degeneration was detected in 17/28 (61%), most predominantly at spinal segments L4-L5 and L5-S1. No back pain/other symptoms were reported. When compared to time point 2, there was no progression in the extent of disc degeneration, including intervertebral disc (IVD) height (p = 0.234), width (p = 0.359), and intervertebral distance (p = 0.641). There was a regression in 2 out of 8 (25%) participants who had pre-marathon sacroiliac joint bone marrow oedema, and a small increase in the size of a pre-marathon subchondral cyst in one participant, all asymptomatic. CONCLUSION: Running 500 miles over 4 months plus a marathon for the first time had no adverse effects on the lumbar spine, even when early degenerative changes were present. Additionally, there was evidence of regression of sacroiliac joint abnormalities.


Assuntos
Degeneração do Disco Intervertebral , Corrida de Maratona , Adulto , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Região Lombossacral , Imageamento por Ressonância Magnética/métodos , Masculino
4.
BMC Musculoskelet Disord ; 22(1): 207, 2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33610170

RESUMO

BACKGROUND: 3D Surgical planning has become a key tool in complex hip revision surgery. The restoration of centre of rotation (CoR) of the hips and leg length (LL) are key factors in achieving good clinical outcome. Pelvic imaging is the gold standard for planning and assessment of LL. We aimed to better understand if 3D planning is effective at equalising LL when large acetabular defects are present. MATERIALS AND METHODS: This was a prospective case study of 25 patients. We report the analysis of pre-operative LL status and planned LL restoration measured on CT, in relation to the achieved LL measured post-operatively in functional, weight bearing position. Our primary objective was the assessment of restoration of CoR as well as the anatomical and functional LL using biplanar full-length standing low-dose radiographs; our secondary objective was to evaluate the clinical outcome. RESULTS: Pre-operative intra-pelvic discrepancy between right and left leg was a mean of 28 mm (SD 17.99, min = 3, max = 60 mm). Post-operatively, the difference between right and left vertical femoral offset (VFO), or CoR discrepancy, was of 7.4 mm on average, significantly different from the functional LL discrepancy (median = 15 mm), p = 0.0024. Anatomical LLD was a median of 15 mm. In one case there was transient foot drop, one dislocation occurred 6 months post-operatively and was treated by closed reduction, none of the patients had had revision surgery at the time of writing. Mean oxford hip score at latest follow up was 32.1/48. DISCUSSION: This is the first study to investigate limb length discrepancy in functional position after reconstruction of large acetabular defects. We observed that VFO is not an optimal surrogate for LL when there is significant bone loss leading to length inequality, fixed flexion of the knee and abduction deformity. CONCLUSIONS: Although challenging, LLD and gait abnormalities can be greatly improved with the aid of an accurate surgical planning. Surgeons and engineers should consider the integration of EOS imaging in surgical planning of reconstruction of large acetabular defects.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Estudos Prospectivos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
5.
MAGMA ; 33(5): 677-688, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32152794

RESUMO

OBJECTIVE: To design, develop and evaluate an automated multi-atlas method for segmentation and volume quantification of gluteus maximus from Dixon and T1-weighted images. MATERIALS AND METHODS: The multi-atlas segmentation method uses an atlas library constructed from 15 Dixon MRI scans of healthy subjects. A non-rigid registration between each atlas and the target, followed by majority voting label fusion, is used in the segmentation. We propose a region of interest (ROI) to standardize the measurement of muscle bulk. The method was evaluated using the dice similarity coefficient (DSC) and the relative volume difference (RVD) as metrics, for Dixon and T1-weighted target images. RESULTS: The mean(± SD) DSC was 0.94 ± 0.01 for Dixon images, while 0.93 ± 0.02 for T1-weighted. The RVD between the automated and manual segmentation had a mean(± SD) value of 1.5 ± 4.3% for Dixon and 1.5 ± 4.8% for T1-weighted images. In the muscle bulk ROI, the DSC was 0.95 ± 0.01 and the RVD was 0.6 ± 3.8%. CONCLUSION: The method allows an accurate fully automated segmentation of gluteus maximus for Dixon and T1-weighted images and provides a relatively accurate volume measurement in shorter times (~ 20 min) than the current gold-standard manual segmentations (2 h). Visual inspection of the segmentation would be required when higher accuracy is needed.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Humanos , Músculo Esquelético , Coxa da Perna
6.
Skeletal Radiol ; 49(8): 1221-1229, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32065245

RESUMO

OBJECTIVE: To evaluate changes in the knee joints of asymptomatic first-time marathon runners, using 3.0 T MRI, 6 months after finishing marathon training and run. MATERIALS AND METHODS: Six months after their participation in a baseline study regarding their knee joints, 44 asymptomatic novice marathoners (17 males, 27 females, mean age 46 years old) agreed to participate in a repeat MRI investigation: 37 completed both a standardized 4-month-long training programme and the marathon (marathon runners); and 7 dropped out during training (pre-race dropouts). The participants already underwent bilateral 3.0 T MRIs: 6 months before and 2 weeks after their first marathon, the London Marathon 2017. This study was a follow-up assessment of their knee joints. Each knee structure was assessed using validated scoring/grading systems at all time points. RESULTS: Two weeks after the marathon, 3 pre-marathon bone marrow lesions and 2 cartilage lesions showed decrease in radiological score on MRI, and the improvement was sustained at the 6-month follow-up. New improvements were observed on MRI at follow-up: 5 pre-existing bone marrow lesions and 3 cartilage lesions that remained unchanged immediately after the marathon reduced in their extent 6 months later. No further lesions appeared at follow-up, and the 2-week post-marathon lesions showed signs of reversibility: 10 of 18 bone marrow oedema-like signals and 3 of 21 cartilage lesions decreased on MRI. CONCLUSION: The knees of novice runners achieved sustained improvement, for at least 6 months post-marathon, in the condition of their bone marrow and articular cartilage.


Assuntos
Traumatismos em Atletas/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Corrida de Maratona , Medula Óssea/diagnóstico por imagem , Cartilagem Articular/diagnóstico por imagem , Edema/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Corrida de Maratona/lesões , Pessoa de Meia-Idade , Estudos Prospectivos
7.
Skeletal Radiol ; 49(7): 1099-1107, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32060622

RESUMO

OBJECTIVE: To identify abnormalities in asymptomatic sedentary individuals using 3.0 Tesla high-resolution MRI. MATERIALS AND METHODS: The cohort comprised of 230 knees of 115 uninjured sedentary adults (51 males, 64 females; median age: 44 years). All participants had bilateral knee 3.0 T MRIs. Two senior musculoskeletal radiologists graded all intraarticular knee structures using validated scoring systems. Participants completed Knee Injury and Osteoarthritis Outcome Score questionnaires at the time of the MRI scan. RESULTS: MRI showed abnormalities in the majority (97%) of knees. Thirty percent knees had meniscal tears: horizontal (23%), complex (3%), vertical (2%), radial (2%) and bucket handle (1%). Cartilage and bone marrow abnormalities were prevalent at the patellofemoral joint (57% knees and 48% knees, respectively). Moderate and severe cartilage lesions were common, in 19% and 31% knees, respectively, while moderate and severe bone marrow oedema in 19% and 31% knees, respectively. Moderate-intensity lesion in tendons was found in 21% knees and high-grade tendonitis in 6% knees-the patellar (11% and 2%, respectively) and quadriceps (7% and 2%, respectively) tendons being most affected. Three percent partial ligamentous ruptures were found, especially of the anterior cruciate ligament (2%). CONCLUSION: Nearly all knees of asymptomatic adults showed abnormalities in at least one knee structure on MRI. Meniscal tears, cartilage and bone marrow lesions of the patellofemoral joint were the most common pathological findings. Bucket handle and complex meniscal tears were reported for the first time in asymptomatic knees.


Assuntos
Doenças Assintomáticas , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Comportamento Sedentário , Adulto , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Doenças da Medula Óssea/diagnóstico por imagem , Doenças das Cartilagens/diagnóstico por imagem , Feminino , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Masculino , Osteoartrite do Joelho/diagnóstico por imagem , Prevalência , Inquéritos e Questionários , Tendinopatia/diagnóstico por imagem
8.
Knee Surg Sports Traumatol Arthrosc ; 28(7): 2027-2035, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32524164

RESUMO

PURPOSE: It was the primary purpose of the present systematic review to identify the optimal protection measures during COVID-19 pandemic and provide guidance of protective measures for orthopedic surgeons. The secondary purpose was to report the protection experience of an orthopedic trauma center in Wuhan, China during the pandemic. METHODS: A systematic search of the PubMed, Cochrane, Web of Science, Google Scholar was performed for studies about COVID-19, fracture, trauma, orthopedic, healthcare workers, protection, telemedicine. The appropriate protective measures for orthopedic surgeons and patients were reviewed (on-site first aid, emergency room, operating room, isolation wards, general ward, etc.) during the entire diagnosis and treatment process of traumatic patients. RESULTS: Eighteen studies were included, and most studies (13/18) emphasized that orthopedic surgeons should pay attention to prevent cross-infection. Only four studies have reported in detail how orthopedic surgeons should be protected during surgery in the operating room. No detailed studies on multidisciplinary cooperation, strict protection, protection training, indications of emergency surgery, first aid on-site and protection in orthopedic wards were found. CONCLUSION: Strict protection at every step in the patient pathway is important to reduce the risk of cross-infection. Lessons learnt from our experience provide some recommendations of protective measures during the entire diagnosis and treatment process of traumatic patients and help others to manage orthopedic patients with COVID-19, to reduce the risk of cross-infection between patients and to protect healthcare workers during work. LEVEL OF EVIDENCE: IV.


Assuntos
Infecções por Coronavirus/prevenção & controle , Infecção Hospitalar/prevenção & controle , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Procedimentos Ortopédicos/métodos , Ortopedia , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Telemedicina/métodos , Filtros de Ar , Betacoronavirus , COVID-19 , Teste para COVID-19 , China , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/transmissão , Procedimentos Cirúrgicos Eletivos , Emergências , Serviço Hospitalar de Emergência , Primeiros Socorros , Fraturas Ósseas/cirurgia , Humanos , Salas Cirúrgicas , Cirurgiões Ortopédicos , Equipamento de Proteção Individual , Pneumonia Viral/diagnóstico , Pneumonia Viral/transmissão , SARS-CoV-2 , Transporte de Pacientes , Centros de Traumatologia
9.
Int Orthop ; 41(12): 2495-2501, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28578471

RESUMO

PURPOSE: We aimed to assess polyethylene liners of retrieved hips of one design of a dual mobility (DM) cup liner and two designs of femoral stems to better understand the role of femoral stem design on polyethylene impingement. METHODS: This was a case-control study involving 70 retrieved highly cross-linked polyethylene (X3) liners used with ABGII (n = 35) and Rejuvenate (n = 35) stems (Stryker). All polyethylene liners were assessed for evidence of rim deformation and the damage quantified using metrology methods. RESULTS: A total of 80% of polyethylene liners paired with ABGII necks had macroscopic evidence of neck impingement resulting in a raised lip whilst 23% of liners paired with Rejuvenate necks had evidence of a raised lip (p < 0.0001). The height of the raised rims of the DM cups paired with ABGII necks had a median (range) of 139 µm (72-255). The height of the raised rims of the DM cups paired with Rejuvenate necks had a median (range) of 52 µm (45-90) (p < 0.0001). CONCLUSION: Our new findings from retrieved dual mobility bearings showed that polyethylene liner rim deformation resulting from impingement with the femoral neck occurs in early in-human function, is circumferential in distribution, and is affected by the stem neck design. We recommend the use of highly polished and non-edged neck designs when used in conjunction with DM cups.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Desenho de Prótese/efeitos adversos , Falha de Prótese/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos de Casos e Controles , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno/efeitos adversos , Fatores de Tempo , Microtomografia por Raio-X
10.
J Orthop Res ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39294102

RESUMO

Statistical shape modeling (SSM) offers the potential to describe the morphological differences in similar shapes using a compact number of variables. Its application in orthopedics is rapidly growing. In this study, an SSM of the intramedullary canal of the proximal femur was built, with the aim to better understanding the complexity of its shape which may, in turn, enhance the preoperative planning of total hip arthroplasty (THA). This includes the prediction of the prosthetic femoral version (PFV) which is known to be highly variable amongst patients who have undergone THA. The model was built on three dimensional (3D) models of 64 femoral canals which were generated from pelvic computed tomography images including the proximal femur in the field of view. Principal component analysis (PCA) was performed on the mean shape derived from the model and each segmented canal. Five prominent modes of variations representing approximately 84% of the total 3D variations in the population of shapes were found to capture variability in size, proximal torsion, intramedullary femoral anteversion, varus/valgus orientation, and distal femoral shaft twist/torsion, respectively. It was established that the intramedullary femoral canal is highly variable in its size, shape, and orientation between different subjects. PCA-driven SSM is beneficial for identifying patterns and extracting valuable features of the femoral canal.

11.
J Orthop Res ; 42(8): 1791-1800, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38408764

RESUMO

In revision total hip arthroplasty, achieving robust fixation is difficult and implant movement may occur over time. Bone may also rearrange around the implant as a result of mechanical loading, making the measurement of migration challenging. The study aimed to quantify changes in bone shape and implant position 1 year following acetabular reconstruction using custom three-dimensional-printed cups. This observational retrospective cohort study involved 23 patients with Paprosky type IIIB defects. Postop computed tomography scans taken within 1 week of surgery and at 1-year postsurgery were co-registered and analyzed. Three co-registration strategies were implemented including bone-to-bone and implant-to-implant. (1) Co-registration of the ipsilateral innominate bone (diseased anatomy) was used to measure changes in implant position. (2) Co-registration of the implant was carried out to quantify changes in the ipsilateral innominate bone shape. (3) Co-registration of the contralateral innominate bone (nondiseased anatomy) was performed to measure changes in the ipsilateral innominate bone shape and implant position. The median centroid distances (interquartile range [IQR]) were 2.3 mm (IQR: 3.7-1.7 mm) for changes in implant position, 2.4 mm (IQR: 3.6-1.6 mm) for changes in ipsilateral innominate bone shape, and 3.7 mm (IQR: 4.6-3.5 mm) for changes in ipsilateral innominate bone shape and implant position. Following acetabular reconstruction, implant movements and periprosthetic bone remodeling are physiological and of a similar extent. Surgeons and engineers should consider this when performing implant monitoring in these patients.


Assuntos
Acetábulo , Artroplastia de Quadril , Remodelação Óssea , Prótese de Quadril , Humanos , Acetábulo/cirurgia , Acetábulo/diagnóstico por imagem , Feminino , Estudos Retrospectivos , Idoso , Masculino , Pessoa de Meia-Idade , Artroplastia de Quadril/instrumentação , Falha de Prótese , Idoso de 80 Anos ou mais , Tomografia Computadorizada por Raios X
12.
J Orthop Res ; 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-38992884

RESUMO

Large acetabular bone defects are challenging in hip revision surgery. Clinical assessment is crucial to evaluate modern technologies in surgical reconstruction. We aimed to better understand the bone remodeling that occurs following acetabular reconstruction. Our objectives were: (1) To characterize changes in the shape of the pelvis by studying sequential computed tomography (CT) scans collected immediately and 1-year postoperatively and (2) to identify which part of the pelvis is most susceptible to remodeling. We used the CT scans taken at two timepoints, of 24 patients with acetabular bone defects classified as Paprosky IIIB, treated with three-dimensional (3D)-printed custom-made acetabular implants. Segmented 3D models of the bony pelvis were co-registered using three different techniques. A global co-registration of the full pelvis was conducted, followed by the co-registration of the innominate bone and then ilium only, on the ipsilateral reconstructed side. The relative movements of the ilium, ischium, and pubis were analyzed from visual inspection and using co-registration metrics (root mean square error and intersection over union). No bone remodeling was found in 14/24 patients (58%). The co-registration of the innominate bone indicated bone remodeling in five cases (21%), while the remaining five cases (21%) presented remodeling in the global co-registration but not the innominate bone co-registration, suggestive of changes occurring at the sacroiliac joint. Changes in the pelvic shape were greatest at the pubis and ischium. Bone remodeling may occur in complex cases of Paprosky type IIIB defects, after acetabular reconstruction (occurrence of 21%, 5/24 cases). Surgeons and engineers should consider this when monitoring implant migration.

13.
J Orthop Res ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39171637

RESUMO

3D printing is a rapidly growing manufacturing method of medical implants. In orthopedics, this method enables the construction of complex porous structures with the aim of improved bone fixation. A known by-product of the 3D printing process is surface adhered particles which are often challenging to remove from the strut surfaces of the porous region. This study investigates the presence of these particles in the porous region of unused 3D printed off-the-shelf acetabular cup from five manufacturers. Scanning Electron Microscopy (SEM) and image analysis software were used to determine the frequency and diameters of particles present on these implants. Surface adhered particles were found in the porous structures of all implants with some exhibiting more particles at the subsurface level than the surface level. Implants manufactured via Selective Laser Melting (SLM) exhibited a higher number of surface adhered particles per mm2 at both the surface and subsurface levels than those manufactured by Electron Beam Melting (EBM). Additionally, and consistent with previous literature, the particle diameter of the SLM cups was found to be smaller than those on the EBM cups, as well as having a visually lower level of adherence which could raise concern about the likelihood of breakage of these particles in-vivo.

14.
3D Print Med ; 10(1): 31, 2024 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-39342047

RESUMO

BACKGROUND: The Trident II Tritanium acetabular shell is additively manufactured (3D printed), based on the established Trident 'I' Tritanium shell, produced using conventional methods; this study characterised their differences. METHODS: We obtained 5 Trident I (T1) and 5 Trident II (T2) shells sized 52 mm, 54 mm (n = 3) and 60 mm. We measured their: mass, shell-liner engaging surface roughness, roundness, wall thickness, the depth of the bone-facing porous layer, porosity, and the number, volume and location of structural voids. RESULTS: The mass varied by up to 13.44 g. The T1 and T2 shells had a median internal roughness of 0.18 µm and 0.43 µm, (p < 0.001) and the median departure from roundness was 6.9 µm and 8.9 µm, (p < 0.001). The 54 mm and 60 mm T2 shell walls were 37% and 29% thinner than their T1 counterparts (p < 0.01). The T2 shells had irregular porous structures, shallower in depth by 11-27% (p < 0.001) than T1 shells, which had repeating mesh units; the overall porosity was comparable (54%). All T2 shells had between 115 and 3415 structural voids, compared with two T1 shells containing 21 and 31 voids. There was no difference in the depth of the porous layer for the 54 mm T2 shells (p = 0.068), whilst T1 shells did show variability (p < 0.01). Both groups showed a variability in surface roughness and roundness (p < 0.01). CONCLUSION: This is the first study to compare shells from a single manufacturer, produced using conventional and additive methods. This data will help interpret the performance of the 3D printed Trident II as longer-term clinical data is generated.

15.
EFORT Open Rev ; 9(9): 862-872, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222334

RESUMO

Three-dimensional printing is a rapidly growing manufacturing method for orthopaedic implants and it is currently thriving in several other engineering industries. It enables the variation of implant design and the construction of complex structures which can be exploited in orthopaedics and other medical sectors. In this review, we develop the vocabulary to characterise 3D printing in orthopaedics from terms defined by industries employing 3D printing, and by fully examining a 3D-printed off-the-shelf acetabular cup (Fig. 1). This is a commonly used 3D-printed implant in orthopaedics, and it exhibits a range of prominent features brought about by 3D printing. The key features and defects of the porous and dense regions of the implant are clarified and discussed in depth to determine reliable definitions and a common understanding of characteristics of 3D printing between engineers and medical experts in orthopaedics. Despite the extensive list of terminology derived here, it is clear significant gaps exist in the knowledge of this field. Therefore, it is necessary for continued investigations of unused implants, but perhaps more significantly, examining those in vivo and retrieved to understand their long-term impact on patients and the effects of certain features (e.g. surface-adhered particles). Analyses of this kind will establish an understanding of 3D printing in orthopaedics and additionally it will help to update the regulatory approach to this new technology.

16.
EFORT Open Rev ; 8(11): 809-817, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37909704

RESUMO

CT is the principal imaging modality used for the pre-operative 3D planning and assessment of total hip arthroplasty (THA). The image quality offered by CT has a radiation penalty to the patient. Higher than necessary radiation exposure is of particular concern when imaging young patients and women of childbearing age, due to the greater risk of radiation-induced cancer in this group. A harmonised low-dose CT protocol is needed, evidenced by the huge variability in the 17 protocols reviewed. The majority of the protocols were incomplete, leading to uncertainty among radiographers when performing the scans. Only three protocols (20%) were optimised for both 'field of view' and image acquisition parameters. 10 protocols (60%) were optimised for 'field of view' only. These protocols included imaging of the relevant landmarks in the bony pelvis in addition to the knees - the reference for femoral anteversion. CT parameters, including the scanner kilovoltage (kV), milliamperage-time product (mAs) and slice thickness, must be optimised with a 'field of view' that includes the relevant bony landmarks. The recommended kV and mAs values were very wide ranging from 100 to 150 and from 100 to 250, respectively. The large variability that exists amongst the CT protocols illustrates the need for a more consistent low-dose CT protocol for the planning of THA. This must provide an optimal balance between image quality and radiation dose to the patient. Current CT scanners do not allow for measurements of functional pelvic orientation and additional upright imaging modalities are needed to augment them.

17.
Artigo em Inglês | MEDLINE | ID: mdl-37197697

RESUMO

The management of massive acetabular defects at the time of revision hip surgery is challenging. Severe pelvic bone loss and the heterogeneity and quality of the remaining bone stock can compromise the fixation and mechanical stability of the implant. Methods: We reviewed a database of consecutive patients who had undergone acetabular reconstruction with the use of a custom 3D-printed implant with a dual-mobility bearing for the treatment of Paprosky type-3B defects between 2016 and 2019. Functional and radiological outcomes were assessed. Results: A total of 26 patients (17 women and 9 men) with a minimum follow-up of 36 months (median, 53 months; range, 36 to 77 months) were identified. The median age at surgery was 69 years (range, 49 to 90 years), and 4 patients had pelvic discontinuity. The cumulative implant survivorship was 100%. The median Oxford Hip Score improved significantly from 8 (range, 2 to 21) preoperatively to 32 (range, 14 to 47) postoperatively (p = 0.0001). One patient had a transient sciatic nerve palsy, 1 hip dislocated 6 months postoperatively and was managed nonoperatively, and 1 infection recurred. No patient had a fracture. Radiographic evaluation showed bone ingrowth at the bone-implant interface in 24 patients (92%) at ≥12 months of follow-up and showed no evidence of implant loosening or migration at the latest follow-up (3 to 6 years). Conclusions: Excellent functional improvement, implant survivorship, and osseointegration were recorded in the patient cohort. Accurate preoperative planning and the adoption of custom 3D-printed implants showed promising results in complex revision hip surgery. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

18.
3D Print Med ; 9(1): 11, 2023 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-37058277

RESUMO

BACKGROUND: Implantation of the femoral component with suboptimal version is associated with instability of the reconstructed hip joint. High variability of Prosthetic Femoral Version (PFV) has been reported in primary Total Hip Arthroplasty (THA). Three-dimensional (3D) Patient-Specific Instrumentation (PSI) has been recently developed and may assist in delivering a PFV within the intended range. We performed a pilot study to better understand whether the intra-operative use of a novel PSI guide, designed to deliver a PFV of 20°, results in the target range of PFV in primary cemented THA. METHODS: We analysed post-operative Computed-Tomography (CT) data of two groups of patients who underwent primary cemented THA through posterior approach; 1. A group of 11 patients (11 hips) for which the surgeon used an intra-operative 3D-printed stem positioning guide (experimental) 2. A group of 24 patients (25 hips) for which the surgeon did not use the guide (control). The surgeon aimed for a PFV of 20°, and therefore the guide was designed to indicate the angle at which the stem was positioned intra-operatively. PFV angles were measured using the post-operative 3D-CT models of the proximal femurs and prosthetic components in both groups. Our primary objective was to compare the PFV in both groups. Our secondary objective was to evaluate the clinical outcome. RESULTS: Mean (± SD) values for the PFV was 21.3° (± 4.6°) and 24.6° (± 8.2°) for the experimental and control groups respectively. In the control group, 20% of the patients reported a PFV outside the intended range of 10° to 30° anteversion. In the experimental group, this percentage dropped to 0%. Satisfactory clinical outcome was recorded in both groups. CONCLUSION: The intra-operative use of a PSI PFV guide helped the surgeon avoid suboptimal PFV in primary cemented THA. Further studies are needed to evaluate if the PSI guide directly contributes to a better clinical outcome.

19.
J Orthop Surg Res ; 18(1): 948, 2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38071336

RESUMO

BACKGROUND: Three-dimensional computed-tomography (3D-CT) planning for primary Total Hip Arthroplasty (THA) typically uses the external femoral surface; as a result, it is difficult to predict the prosthetic femoral version (PFV) for uncemented femoral stems that press-fit to the internal surface of the bone. Cemented fixation allows the surgeon to adjust the version independent of the internal femoral anatomy. We aimed to better understand the effect of the fixation type on PFV. METHODS: This was a case series study including a total of 95 consecutive patients (106 hips), who underwent uncemented (n = 81 hips) and cemented (n = 25 hips) primary THA using the posterior approach. The surgeon aimed for a PFV of 20°. Our primary objective was to compare PFV in both groups; our secondary objective was to evaluate the clinical outcomes. RESULTS: The mean (± SD) PFV was 13° (± 9°) and 23° (± 8°) for the uncemented and cemented THA groups (P < 0.001), respectively. In the uncemented THA group, 36% of the patients had a PFV of < 10°. In the cemented THA group, this clinically important threshold dropped to 8%. Similarly, the Bland-Altman (BA) plots showed wider 95% limits of agreement for the uncemented group. Satisfactory clinical outcomes were recorded. CONCLUSION: We found that the PFV was more clinically acceptable, for the posterior surgical approach, in the cemented group when compared to the uncemented group. Both THA groups reported high variability indicating the need to develop surgical tools to guide the PFV closer to the surgical target.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Falha de Prótese , Desenho de Prótese , Resultado do Tratamento
20.
Med Eng Phys ; 116: 103985, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37230697

RESUMO

Three-Dimensional Computed Tomography (3D-CT) planning can predict the prosthetic femoral size in uncemented primary Total Hip Arthroplasty (THA). Correct sizing usually results in optimal varus/valgus femoral alignment; however, its effect on the Prosthetic Femoral Version (PFV) is poorly understood. Most 3D-CT planning systems use Native Femoral Version (NFV) to plan PFV. We aimed to assess the relationship between PFV and NFV in primary uncemented THA using 3D-CT analysis. Pre- and post-operative CT data was retrospectively collected from 73 patients (81 hips) undergoing primary uncemented THA with a straight-tapered stem. 3D-CT models were used to measure PFV and NFV. The clinical outcomes were evaluated. The discrepancy between PFV and NFV was low (<5°) in 43%, moderate (5-10°) in 40%, high (10-15°) in 11% and very high (>15°) in 6% of the cases. We found that NFV is not a useable guide for planning PFV. The 95% limits of agreement were both high at 17° and 15°, respectively. Satisfactory clinical outcomes were recorded. The discrepancy was large enough to recommend against the use of NFV for planning PFV when using straight-tapered uncemented stems. Further work should focus on the internal bony anatomy and the influence of stem design when planning uncemented femoral stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Artroplastia de Quadril/métodos , Tomografia Computadorizada por Raios X , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA