Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Proteomics ; 21(1): 5, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267848

RESUMO

BACKGROUND: The 2022 consensus statement of the European Atherosclerosis Society (EAS) on lipoprotein(a) (Lp(a)) recognizes the role of Lp(a) as a relevant genetically determined risk factor and recommends its measurement at least once in an individual's lifetime. It also strongly urges that Lp(a) test results are expressed as apolipoprotein (a) (apo(a)) amount of substance in molar units and no longer in confounded Lp(a) mass units (mg/dL or mg/L). Therefore, IVD manufacturers should transition to molar units. A prerequisite for this transition is the availability of an Lp(a) Reference Measurement Procedure (RMP) that allows unequivocal molecular detection and quantification of apo(a) in Lp(a). To that end an ISO 17511:2020 compliant LC-MS based and IFCC-endorsed RMP has been established that targets proteotypic peptides of apolipoprotein(a) (apo(a)) in Lp(a). The RMP is laborious and requires highly skilled operators. To guide IVD-manufacturers of immunoassay-based Lp(a) test kits in the transition from mass to molar units, a Designated Comparison Method (DCM) has been developed and evaluated. METHODS: To assess whether the DCM provides equivalent results compared to the RMP, the procedural designs were compared and the analytical performance of DCM and RMP were first evaluated in a head-to-head comparison. Subsequently, apo(a) was quantified in 153 human clinical serum samples. Both DCM and RMP were calibrated using external native calibrators that produce results traceable to SRM2B. Measurement uncertainty (MU) was checked against predefined allowable MU. RESULTS: The major difference in the design of the DCM for apo(a) is the use of only one enzymatic digestion step. The analytical performance of the DCM and RMP for apo(a) is highly similar. In a direct method comparison, equivalent results were obtained with a median regression slope 0.997 of and a median bias of - 0.2 nmol/L (- 0.2%); the intermediate imprecision of the test results was within total allowable error (TEa) (CVa of 10.2% at 90 nmol/L). CONCLUSIONS: The semi-automated, higher throughput, LC-MS-based method for Lp(a) meets the predefined analytical performance specifications and allowable MU and is hence applicable as a higher order Designated Comparison Method, which is ideally suited to guide IVD manufacturers in the transition from Lp(a) mass to molar units.

2.
Crit Rev Clin Lab Sci ; 60(7): 483-501, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37128734

RESUMO

In the past decade a remarkable rebirth of serum/plasma lipoprotein(a) (Lp(a)) as an independent risk factor of cardiovascular disease (CVD) occurred. Updated evidence for a causal continuous association in different ethnic groups between Lp(a) concentrations and cardiovascular outcomes has been published in the latest European Atherosclerosis Society (EAS) Lp(a) consensus statement. Interest in measuring Lp(a) at least once in a person's lifetime moreover originates from the development of promising new Lp(a) lowering drugs. Accurate and clinically effective Lp(a) tests are of key importance for the timely detection of high-risk individuals and for future evaluation of the therapeutic effects of Lp(a) lowering medication. To this end, it is necessary to improve the performance and standardization of existing Lp(a) tests, as is also noted in the Lp(a) consensus statement. Consequently, a state-of-the-art internationally endorsed reference measurement system (RMS) must be in place that allows for performance evaluation of Lp(a) field tests in order to certify their validity and accuracy. An ELISA-based RMS from Northwest Lipid Research Laboratory (University of Washington, Seattle, USA) has been available since the 1990s. A next-generation apo(a)/Lp(a) RMS is now being developed by a working group from the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). The envisioned apo(a) RMS is based on the direct measurement of selected proteotypic fragments generated after proteolytic digestion using quantitative protein mass spectrometry (MS). The choice for an MS-based RMS enables selective measurement of the proteotypic peptides and is by design apo(a) isoform insensitive. Clearly, the equimolar conversion of apo(a) into the surrogate peptide measurands is required to obtain accurate Lp(a) results. The completeness of proteolysis under reaction conditions from the candidate reference measurement procedure (RMP) has been demonstrated for the quantifying apo(a) peptides. Currently, the candidate apo(a) RMP is endorsed by the IFCC and recommendations for suitable secondary reference materials have been made in a recent commutability study paper. Ongoing efforts toward a complete apo(a) RMS that is listed by the Joint Committee on Traceability in Laboratory Medicine (JCTLM) are focused on the peptide-based calibration and the establishment of a network of calibration laboratories running the apo(a) RMS in a harmonized way. Once completed, it will be the holy grail for evaluation and certification of Lp(a) field methods.

3.
J Appl Lab Med ; 2024 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-39239905

RESUMO

BACKGROUND: To evaluate the clinical performance and effectiveness of a multiplex apolipoprotein panel in the context of cardiovascular precision diagnostics, clinical samples of patients with recent acute coronary syndrome in the ODYSSEY OUTCOMES trial were measured by quantitative clinical chemistry proteomics (qCCP). The ISO15189-accredited laboratory setting, including the total testing process (TTP), served as a foundation for this study. Consequently, tailored quality assurance measures needed to be designed and implemented to suit the demands of a multiplex LC-MS/MS test. METHODS: Nine serum apolipoproteins were measured in 23 376 samples with a laboratory-developed multiplex apolipoprotein test on 4 Agilent 6495 LC-MS/MS systems. A fit-for-purpose process was designed with tailored additions enhancing the accredited laboratory infrastructure and the TTP. Quality assurance was organized in 3 steps: system suitability testing (SST), internal quality control (IQC) evaluation with adjusted Westgard rules to fit a multiplex test, and interpeptide agreement analysis. Data was semi-automatically evaluated with a custom R script. RESULTS: LC-MS/MS analyses were performed with the following between-run CVs: for apolipoprotein (Apo) (a) 6.2%, Apo A-I 2.3%, Apo A-II 2.1%, Apo A-IV 2.9%, Apo B 1.9%, Apo C-I 3.3%, Apo C-II 3.3%, Apo C-III 2.7%, and for Apo E 3.3% and an average interpeptide agreement Pearson r of 0.981. CONCLUSIONS: This is the first study of its kind in which qCCP was performed at this scale. This research successfully demonstrates the feasibility of high-throughput LC-MS/MS applications in large clinical trials. ClinicalTrials.gov Registration Number: NCT01663402.

4.
J Mass Spectrom Adv Clin Lab ; 27: 49-55, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36619217

RESUMO

In the pursuit of personalized diagnostics and tailored treatments, quantitative protein tests contribute to a more precise definition of health and disease. The development of new quantitative protein tests should be driven by an unmet clinical need and performed in a collaborative effort that involves all stakeholders. With regard to the analytical part, mass spectrometry (MS)-based platforms are an excellent tool for quantification of specific proteins in body fluids, for example focused on cancer. The obtained readouts have great potential in determining tumor aggressiveness to facilitate treatment decisions, and can furthermore be used to monitor patient response. Internationally standardized TNM classifications of malignant tumors are beneficial for diagnosis, however treatment outcome and survival of cancer patients is poorly predicted. To this end, the importance of the tumor microenvironment has endorsed the introduction of the tumor-stroma ratio as a prognostic parameter in solid primary tumor types. Currently, the stromal content of tumor tissues is determined via routine diagnostic pathology slides. With the development of liquid chromatography (LC)-MS methods we aim at quantification of tumor-stroma specific proteins in body fluids. In this mini-review the analytical aspect of this developmental trajectory is further detailed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA