Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Ultrasound Med Biol ; 49(6): 1465-1475, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36967332

RESUMO

OBJECTIVE: The aim of this work was to evaluate the reliability of power Doppler ultrasound (PD-US) measurements made without contrast enhancement to monitor temporal changes in peripheral blood perfusion. METHODS: On the basis of pre-clinical rodent studies, we found that combinations of spatial registration and clutter filtering techniques applied to PD-US signals reproducibly tracked blood perfusion in skeletal muscle. Perfusion is monitored while modulating hindlimb blood flow. First, in invasive studies, PD-US measurements in deep muscle with laser speckle contrast imaging (LSCI) of superficial tissues made before, during and after short-term arterial clamping were compared. Then, in non-invasive studies, a pressure cuff was employed to generate longer-duration hindlimb ischemia. Here, B-mode imaging was also applied to measure flow-mediated dilation of the femoral artery while, simultaneously, PD-US was used to monitor downstream muscle perfusion to quantify reactive hyperemia. Measurements in adult male and female mice and rats, some with exercise conditioning, were included to explore biological variables. RESULTS: PD-US methods are validated through comparisons with LSCI measurements. As expected, no significant differences were found between sexes or fitness levels in flow-mediated dilation or reactive hyperemia estimates, although post-ischemic perfusion was enhanced with exercise conditioning, suggesting there could be differences between the hyperemic responses of conduit and resistive vessels. CONCLUSION: Overall, we found non-contrast PD-US imaging can reliably monitor relative spatiotemporal changes in muscle perfusion. This study supports the development of PD-US methods for monitoring perfusion changes in patients at risk for peripheral artery disease.


Assuntos
Hiperemia , Masculino , Feminino , Ratos , Camundongos , Animais , Roedores , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo , Músculo Esquelético , Isquemia/diagnóstico por imagem , Ultrassonografia Doppler , Artéria Femoral/diagnóstico por imagem , Dilatação Patológica , Perfusão , Fluxo Sanguíneo Regional
2.
J Nucl Med ; 52(3): 453-60, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21321271

RESUMO

UNLABELLED: Accurate and reproducible SPECT quantification of myocardial molecular processes remains a challenge because of the complication of heterogeneous background and extracardiac activity adjacent to the heart, which causes errors in the estimation of myocardial focal tracer uptake. Our aim in this study was to introduce a heuristic method for the correction of extracardiac activity into SPECT quantification and validate the modified quantification method for accuracy and reproducibility using a canine model. METHODS: Dual-isotope-targeted (99m)Tc and (201)Tl perfusion SPECT images were acquired using a hybrid SPECT/CT camera in 6 dogs at 2 wk after myocardial infarction. Images were reconstructed with and without CT-based attenuation correction, and the reconstructed SPECT images were filtered and quantified simultaneously with incorporation of extracardiac radioactivity correction, gaussian fitting, and total-count sampling. Absolute myocardial focal tracer uptake was quantified from SPECT images using 3 different normal limits (maximum entropy [ME], mean-squared-error minimization [MSEM], and global minimum [GM]). SPECT-quantified percentage injected dose (%ID) was calculated and compared with the well-counted radioactivity measured from the postmortem myocardial tissue. SPECT quantitative processing was performed by 2 different individuals with extensive experience in cardiac image processing, to assess reproducibility of the quantitative analysis. RESULTS: Correlations between SPECT-quantified and well-counted %IDs using 3 different normal limits were excellent (ME: r = 0.82, y = 0.932 x - 0.0102; MSEM: r = 0.73, y = 1.1413 x - 0.0052; and GM: r = 0.7, y = 1.2147 x - 0.0002). SPECT quantification using ME normal limits resulted in an underestimation of %ID, as compared with well-counted %ID. Myocardial focal tracer uptake quantified from SPECT images without CT-based attenuation correction was significantly lower than that with the attenuation correction. The %IDs quantified from attenuation-corrected SPECT images using MSEM and GM normal limits were not significantly different from well-counted %IDs. Reproducibility of the SPECT quantitative analysis was excellent (ME: r = 0.98, y = 0.9221 x + 0.0001; MSEM: r = 0.97, y = 0.9357 x + 0.0004; and GM: r = 0.96, y = 0.9026 x + 0.001). CONCLUSION: Our SPECT/CT quantification algorithm for the assessment of regional radioactivity may allow for accurate and reproducible serial noninvasive evaluation of molecularly targeted tracers in the myocardium.


Assuntos
Imagem Molecular/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/metabolismo , Compostos Radiofarmacêuticos/farmacocinética , Técnica de Subtração , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Cães , Feminino , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Taxa de Depuração Metabólica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual
3.
Med Image Anal ; 13(1): 49-61, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18678521

RESUMO

Modern medical imaging techniques enable the acquisition of in vivo high resolution images of the vascular system. Most common methods for the detection of vessels in these images, such as multiscale Hessian-based operators and matched filters, rely on the assumption that at each voxel there is a single cylinder. Such an assumption is clearly violated at the multitude of branching points that are easily observed in all, but the most focused vascular image studies. In this paper, we propose a novel method for detecting vessels in medical images that relaxes this single cylinder assumption. We directly exploit local neighborhood intensities and extract characteristics of the local intensity profile (in a spherical polar coordinate system) which we term as the polar neighborhood intensity profile. We present a new method to capture the common properties shared by polar neighborhood intensity profiles for all the types of vascular points belonging to the vascular system. The new method enables us to detect vessels even near complex extreme points, including branching points. Our method demonstrates improved performance over standard methods on both 2D synthetic images and 3D animal and clinical vascular images, particularly close to vessel branching regions.


Assuntos
Algoritmos , Angiografia/métodos , Inteligência Artificial , Vasos Sanguíneos/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Reconhecimento Automatizado de Padrão/métodos , Animais , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Tomografia Computadorizada por Raios X/métodos
4.
Am J Pathol ; 169(5): 1886-98, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17071609

RESUMO

We have previously shown that tumor necrosis factor (TNF) acts via its two receptors TNFR1 and TNFR2 to elicit distinct signaling pathways in vascular endothelial cells (ECs). Here we used a femoral artery ligation model to demonstrate that TNFR1-knockout (KO) mice had enhanced, whereas TNFR2-KO had reduced, capacity in clinical recovery, limb perfusion, and ischemic reserve capacity compared with the wild-type mice. Consistently, ischemia-initiated collateral growth (arteriogenesis) in the upper limb and capillary formation and vessel maturation (angiogenesis) in the lower limb were enhanced in TNFR1-KO but were reduced in TNFR2-KO mice. Furthermore, our results suggest that vascular proliferation, but not infiltration of macrophages and lymphocytes, accounted for the phenotypic differences between the TNFR1-KO and TNFR2-KO mice. In wild-type animals TNFR2 protein in vascular endothelium was highly up-regulated in response to ischemia, leading to increased TNFR2-specific signaling as determined by the formation TNFR2-TRAF2 complex and activation of TNFR2-specific kinase Bmx/Etk. In isolated murine ECs, activation of TNFR2 induced nuclear factor-kappaB-dependent reporter gene expression, EC survival, and migration. In contrast, activation of TNFR1 caused inhibition of EC migration and EC apoptosis. These data demonstrate that TNFR1 and TNFR2 play differential roles in ischemia-mediated arteriogenesis and angiogenesis, partly because of their opposite effects on EC survival and migration.


Assuntos
Artérias/embriologia , Isquemia/induzido quimicamente , Neovascularização Patológica , Organogênese , Receptores Tipo II do Fator de Necrose Tumoral/metabolismo , Receptores Tipo I de Fatores de Necrose Tumoral/metabolismo , Transdução de Sinais , Sequência de Aminoácidos , Animais , Vasos Sanguíneos , Bovinos , Movimento Celular , Proliferação de Células , Sobrevivência Celular , Células Endoteliais/citologia , Células Endoteliais/patologia , Endotélio Vascular/patologia , Membro Posterior/citologia , Membro Posterior/patologia , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Dados de Sequência Molecular , Perfusão , Proteínas Tirosina Quinases/metabolismo , Receptores Tipo I de Fatores de Necrose Tumoral/química , Fator 2 Associado a Receptor de TNF/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA