Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(19)2019 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-31623312

RESUMO

Ocean colour is recognised as an Essential Climate Variable (ECV) by the Global Climate Observing System (GCOS); and spectrally-resolved water-leaving radiances (or remote-sensing reflectances) in the visible domain, and chlorophyll-a concentration are identified as required ECV products. Time series of the products at the global scale and at high spatial resolution, derived from ocean-colour data, are key to studying the dynamics of phytoplankton at seasonal and inter-annual scales; their role in marine biogeochemistry; the global carbon cycle; the modulation of how phytoplankton distribute solar-induced heat in the upper layers of the ocean; and the response of the marine ecosystem to climate variability and change. However, generating a long time series of these products from ocean-colour data is not a trivial task: algorithms that are best suited for climate studies have to be selected from a number that are available for atmospheric correction of the satellite signal and for retrieval of chlorophyll-a concentration; since satellites have a finite life span, data from multiple sensors have to be merged to create a single time series, and any uncorrected inter-sensor biases could introduce artefacts in the series, e.g., different sensors monitor radiances at different wavebands such that producing a consistent time series of reflectances is not straightforward. Another requirement is that the products have to be validated against in situ observations. Furthermore, the uncertainties in the products have to be quantified, ideally on a pixel-by-pixel basis, to facilitate applications and interpretations that are consistent with the quality of the data. This paper outlines an approach that was adopted for generating an ocean-colour time series for climate studies, using data from the MERIS (MEdium spectral Resolution Imaging Spectrometer) sensor of the European Space Agency; the SeaWiFS (Sea-viewing Wide-Field-of-view Sensor) and MODIS-Aqua (Moderate-resolution Imaging Spectroradiometer-Aqua) sensors from the National Aeronautics and Space Administration (USA); and VIIRS (Visible and Infrared Imaging Radiometer Suite) from the National Oceanic and Atmospheric Administration (USA). The time series now covers the period from late 1997 to end of 2018. To ensure that the products meet, as well as possible, the requirements of the user community, marine-ecosystem modellers, and remote-sensing scientists were consulted at the outset on their immediate and longer-term requirements as well as on their expectations of ocean-colour data for use in climate research. Taking the user requirements into account, a series of objective criteria were established, against which available algorithms for processing ocean-colour data were evaluated and ranked. The algorithms that performed best with respect to the climate user requirements were selected to process data from the satellite sensors. Remote-sensing reflectance data from MODIS-Aqua, MERIS, and VIIRS were band-shifted to match the wavebands of SeaWiFS. Overlapping data were used to correct for mean biases between sensors at every pixel. The remote-sensing reflectance data derived from the sensors were merged, and the selected in-water algorithm was applied to the merged data to generate maps of chlorophyll concentration, inherent optical properties at SeaWiFS wavelengths, and the diffuse attenuation coefficient at 490 nm. The merged products were validated against in situ observations. The uncertainties established on the basis of comparisons with in situ data were combined with an optical classification of the remote-sensing reflectance data using a fuzzy-logic approach, and were used to generate uncertainties (root mean square difference and bias) for each product at each pixel.

2.
Opt Express ; 25(12): A564-A573, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28788838

RESUMO

Chlorophyll-a specific light volume scattering functions (VSFs) by cultured phytoplankton in visible spectrum range is presented. Chlorophyll-a specific VSFs were determined based on the linear least squares method using a measured VSFs with different chlorophyll-a concentrations. We found obvious variability of it in terms of spectral and angular shapes of VSF between cultures. It was also presented that chlorophyll-a specific scattering significantly affected on spectral variation of the remote sensing reflectance, depending on spectral shape of b. This result is useful for developing an advance algorithm of ocean color remote sensing and for deep understanding of light in the sea.


Assuntos
Clorofila/análise , Fitoplâncton/química , Análise Espectral/métodos , Algoritmos , Clorofila A , Cor , Monitoramento Ambiental/métodos , Espalhamento de Radiação
3.
Appl Opt ; 54(25): 7718-33, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26368897

RESUMO

Backscattering coefficients are frequently estimated from light scattering at one backward angle multiplied by a conversion factor. We determined that the shapes of the volume scattering functions (VSFs), particularly for scattering angles larger than 170°, cause significant variations in the conversion factor at 120°. Our approach uses the ratio of scattering at 170° and at 120°, which is a good indicator of the shape differences of the VSFs for most oceanic waters and wavelengths in the visible range. The proposed method provides significant accuracy improvement in the determination of the backscattering coefficients with a prediction error of 3% of the mean.


Assuntos
Espalhamento de Radiação , Algoritmos , Monitoramento Ambiental/métodos , Luz , Nefelometria e Turbidimetria , Óptica e Fotônica , Material Particulado , Fitoplâncton , Tecnologia de Sensoriamento Remoto , Reprodutibilidade dos Testes , Microbiologia da Água
4.
Opt Express ; 21(16): 18697-711, 2013 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-23938786

RESUMO

We present a novel optical approach to measure the volume scattering function (VSF) by image detection. The instrument design, based upon a combination of two reflectors, uses a unique measurement principle and allows the rapid simultaneous determination of scattering at a wide range of angles. The advantages of the newly developed scattering meter are that: 1) it can determine the scattering function from 8° to 172° at 1° intervals without changing the sensitivity of the detector, without moving any optical parts, and can do so within a few seconds, 2) the unique optical design facilitates determination of the spectral VSF over the full visible spectrum, i.e. it can obtain the VSF at a specific wavelength with an optional wavelength-resolution. Measurements under controlled conditions for the assessment of the instrument agreed well with theoretically predicted scattering functions. Measurements with cultured phytoplankton of different species revealed a significant variety of the VSF together with spectral variation. The observed results will stimulate and improve radiative transfer and/or two-flow models of light in the ocean, which is an important role for ocean color remote sensing algorithm development, particularly for coastal regions.

5.
Opt Express ; 19(11): 10063-72, 2011 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-21643265

RESUMO

We developed a new illumination method called the simultaneous illumination method. This method does not require synchronization between light sources and sensor signals, which drastically simplifies the instrumentation. As a proof-of-concept, we applied this method to an oceanographic fluorometer. In principle, using this method, one can easily increase the number of characterized emission wavelengths by mounting optical sensors for as many emission wavelengths as needed. Our fluorometer has two emission-wavelength channels and twelve excitation wavelengths. The aim of this prototype is to demonstrate a viable in situ N-channel emission fluorometer with multiple wavelengths of excitation, which has not been previously realized.


Assuntos
Oceanografia/métodos , Óptica e Fotônica , Fitoplâncton/fisiologia , Imunofluorescência , Luz , Iluminação , Estimulação Luminosa , Fotometria , Fitoplâncton/metabolismo , Espectrofotometria
6.
Appl Opt ; 44(26): 5549-60, 2005 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-16161671

RESUMO

A prototype point-source integrating cavity absorption meter (PSICAM) is presented and compared with spectrophotometric absorption measurements. Different light collector assemblies of the PSICAM were tested regarding their capability to determine the absorption of water constituents accurately over a wide range of concentrations and scattering properties. The PSICAM setup with a radiance-type sensor showed the best performance. It was compared with a photometric absorption determination using nonscattering dye solutions. The mean difference between both methods was less than 2.4% in the spectral range of 400-700 nm. The absorption determination with the PSICAM, when equipped with a radiance sensor as a light collector, was only little affected by scattering and temperature. We conclude that the PSICAM can be used to determine the absorption of natural seawater samples at ambient temperatures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA