RESUMO
PURPOSE: To develop a nuclear medicine specific patient journey audit tool (PJAT) to survey and audit patient journeys in a nuclear medicine department such as staff interaction with patients, equipment, quality of imaging and laboratory procedures, patient protection, infection control and radiation safety, with a view to optimising patient care and providing a high-quality nuclear medicine service. METHODS: The PJAT was developed specifically for use in nuclear medicine practices. Thirty-two questions were formulated in the PJAT to test the department's compliance to the Australian National Safety and Quality Health Service Standards, namely clinical governance, partnering with consumers, preventing and controlling health care infection, medication safety, comprehensive care, communicating for safety, blood management and recognising and responding to acute deterioration. The PJAT was also designed to test our department's adherence to diagnostic reference levels (DRL). A total of 60 patient journey audits were completed for patients presenting for nuclear medicine, positron emission tomography and bone mineral density procedures during a consecutive 4-week period to audit the range of procedures performed. A further 120 audits were captured for common procedures in nuclear medicine and positron emission tomography during the same period. Thus, a total of 180 audits were completed. A subset of 12 patients who presented for blood labelling procedures were audited to solely assess the blood management standard. RESULTS: The audits demonstrated over 85% compliance for the Australian national health standards. One hundred percent compliance was noted for critical aspects such as correct patient identification for the correct procedure prior to radiopharmaceutical administration, adherence to prescribed dose limits and distribution of the report within 24 h of completion of the imaging procedure. CONCLUSION: This PJAT can be applied in nuclear medicine departments to enhance quality programmes and patient care. Austin Health has collaborated with the IAEA to formulate the IAEA PJAT, which is now available globally for nuclear medicine departments to survey patient journeys.
Assuntos
Medicina Nuclear , Medicina Nuclear/normas , Humanos , Indicadores de Qualidade em Assistência à Saúde , Auditoria Médica , AustráliaRESUMO
AIM: The aim of this study was to assess the recovery rates of diagnostic cardiac procedure volumes in the Oceania Region, midway through the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A survey was performed comparing procedure volumes between March 2019 (pre-pandemic), April 2020 (during first wave of COVID-19 pandemic), and April 2021 (1 year into the COVID-19 pandemic). A total of 31 health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, as well as teaching and non-teaching hospitals. A comparison was made with 549 centres in 96 countries in the rest of the world (RoW) outside of Oceania. The total number and median percentage change in procedure volume were measured between the three timepoints, compared by test type and by facility. RESULTS: A total of 11,902 cardiac diagnostic procedures were performed in Oceania in April 2021 as compared with 11,835 pre-pandemic in March 2019 and 5,986 in April 2020; whereas, in the RoW, 499,079 procedures were performed in April 2021 compared with 497,615 pre-pandemic in March 2019 and 179,014 in April 2020. There was no significant difference in the median recovery rates for total procedure volumes between Oceania (-6%) and the RoW (-3%) (p=0.81). While there was no statistically significant difference in percentage recovery been functional ischaemia testing and anatomical coronary testing in Oceania as compared with the RoW, there was, however, a suggestion of poorer recovery in anatomical coronary testing in Oceania as compared with the RoW (CT coronary angiography -16% in Oceania vs -1% in RoW, and invasive coronary angiography -20% in Oceania vs -9% in RoW). There was no statistically significant difference in recovery rates in procedure volume between metropolitan vs regional (p=0.44), public vs private (p=0.92), hospital vs outpatient (p=0.79), or teaching vs non-teaching centres (p=0.73). CONCLUSIONS: Total cardiology procedure volumes in Oceania normalised 1 year post-pandemic compared to pre-pandemic levels, with no significant difference compared with the RoW and between the different types of health care facilities.
Assuntos
COVID-19 , Cardiologia , Humanos , COVID-19/epidemiologia , Pandemias , Inquéritos e Questionários , Angiografia Coronária , Teste para COVID-19RESUMO
BACKGROUND: In patients with multi-vessel disease presenting with ST elevation myocardial infarction (STEMI), the efficacy and safety of ischemia-guided, vs routine non-culprit vessel angioplasty has not been adequately studied. METHODS: We conducted an international, randomized, non-inferiority trial comparing ischemia-guided non-culprit vessel angioplasty to routine non-culprit vessel angioplasty, following primary PCI for STEMI. The primary outcome was the between-group difference in percent ischemic myocardium at follow-up stress MPI. All MPI images were processed and analyzed at a central core lab, blinded to treatment allocation. RESULTS: In all, 109 patients were enrolled from nine countries. In the ischemia-guided arm, 25/48 (47%) patients underwent non-culprit vessel PCI following stress MPI. In the routine non-culprit PCI arm, 43/56 (77%) patients underwent angioplasty (86% within 6 weeks of randomization). The median percentage of ischemic myocardium on follow-up imaging (mean 16.5 months) was low, and identical (2.9%) in both arms (difference 0.13%, 95%CI - 1.3%-1.6%, P < .0001; non-inferiority margin 5%). CONCLUSION: A strategy of ischemia-guided non-culprit PCI resulted in low ischemia burden, and was non-inferior to a strategy of routine non-culprit vessel PCI in reducing ischemia burden. Selective non-culprit PCI following STEMI offers the potential for cost-savings, and may be particularly relevant to low-resource settings. (CTRI/2018/08/015384).
Assuntos
Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Angioplastia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do TratamentoRESUMO
OBJECTIVES: The INCAPS COVID Oceania study aimed to assess the impact caused by the COVID-19 pandemic on cardiac procedure volume provided in the Oceania region. METHODS: A retrospective survey was performed comparing procedure volumes within March 2019 (pre-COVID-19) with April 2020 (during first wave of COVID-19 pandemic). Sixty-three (63) health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, and 846 facilities outside of Oceania. The percentage change in procedure volume was measured between March 2019 and April 2020, compared by test type and by facility. RESULTS: In Oceania, the total cardiac diagnostic procedure volume was reduced by 52.2% from March 2019 to April 2020, compared to a reduction of 75.9% seen in the rest of the world (p<0.001). Within Oceania sites, this reduction varied significantly between procedure types, but not between types of health care facility. All procedure types (other than stress cardiac magnetic resonance [CMR] and positron emission tomography [PET]) saw significant reductions in volume over this time period (p<0.001). In Oceania, transthoracic echocardiography (TTE) decreased by 51.6%, transoesophageal echocardiography (TOE) by 74.0%, and stress tests by 65% overall, which was more pronounced for stress electrocardiograph (ECG) (81.8%) and stress echocardiography (76.7%) compared to stress single-photon emission computerised tomography (SPECT) (44.3%). Invasive coronary angiography decreased by 36.7% in Oceania. CONCLUSION: A significant reduction in cardiac diagnostic procedure volume was seen across all facility types in Oceania and was likely a function of recommendations from cardiac societies and directives from government to minimise spread of COVID-19 amongst patients and staff. Longer term evaluation is important to assess for negative patient outcomes which may relate to deferral of usual models of care within cardiology.
Assuntos
COVID-19 , Cardiologia , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND: Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. METHODS: The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. RESULTS: Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. CONCLUSIONS: In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.
Assuntos
Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Países em Desenvolvimento , Teste de Esforço , Feminino , Geografia , Coração , Ventrículos do Coração , Humanos , Cooperação Internacional , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Variações Dependentes do Observador , Tomografia por Emissão de Pósitrons/métodos , Pobreza , Risco , Volume Sistólico , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/normas , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular EsquerdaRESUMO
There remains a clinical question of which patients benefit from revascularization of non-culprit coronary artery stenosis in the setting of acute ST-segment elevation myocardial infraction (STEMI). This is a large population of patients with prior studies showing 40 to 70% of patients with STEMI having non-culprit stenosis. This article reviews the current state of the literature evaluating outcomes of those previously randomized to revascularization of non-culprit stenosis around the time of the STEMI. We propose a new study design to utilize gated-SPECT in the decision process by using an ischemic burden of > 5% as a cut-off for revascularization vs. complete revascularization without ischemia assessment.
Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Estenose Coronária/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Guias de Prática Clínica como Assunto , Infarto do Miocárdio com Supradesnível do Segmento ST/terapiaRESUMO
BACKGROUND: Combined assessment of perfusion and function improves diagnostic and prognostic power of gated-SPECT in patients with coronary artery disease. The aim of this study was to investigate whether the presence of stress-induced ischemia is associated with abnormal resting left ventricular (LV) function and intraventricular dyssynchrony. METHODS AND RESULTS: Gated-SPECT myocardial perfusion imaging (MPI) at rest and 15 min post-stress was performed in 101 patients, who were divided into three groups: those with stress-induced ischemia (Group 1, n = 58), those with normal scans (Group 2, n = 28), and those with scar but no ischemia (Group 3, n = 15). More extensive perfusion defects were found in patients of Groups 1 and 3 [Summed stress score (SSS): 13 ± 8 and 21 ± 9, respectively]. In Group 2, the mean SSS was 1.5. The mean change in LV ejection fraction (LVEF at stress - LVEF at rest) was higher in Group 1 v. Group 2 patients: -5.54% ± 6.24% vs -2.46% ± 5.56%, p = 0.02. Group 3 patients also had higher values, similar to Group 1: -6.47% ± 8.82%. Patients with ischemia had almost 50% higher end-diastolic volumes than patients with normal MPI. Similarly, end-systolic volumes were almost twice as high in this group (p < 0.0001). In addition, the histogram bandwidth, a measure of intraventricular dyssynchrony, was greater in Group 1. CONCLUSIONS: Baseline differences in left ventricular volumes and degree of dyssynchrony are associated with inducible ischemia on stress testing in a gated-SPECT MPI. Stress-induced ischemia increases the degree of intraventricular dyssynchrony.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Cicatriz/diagnóstico por imagem , Estudos Transversais , Teste de Esforço , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular EsquerdaRESUMO
The burden of cardiovascular diseases (CVDs) in the world is ever growing. They represent the first cause of death worldwide and in Latin America. Nuclear cardiology has a well-established role in the management of patient with CVDs and is being increasingly integrated into the healthcare systems in the region. However, there remains variability as to the infrastructure available across the countries, in terms of existing technology, radiopharmaceuticals, and human resources. The approximate number of gamma (γ) cameras in the region is 1348, with an average of 2.25 per million population; Argentina and Brazil having the largest number. Nearly 80% of the existing cameras are single-photon emission tomography (SPECT), of which 8% are hybrid SPECT-CT systems. Positron emission tomography technology is steadily increasing, and currently, there is an average of 0.25 scanners per million inhabitants, indicating that there is a potential to expand the capacities in order to cover the needs. Four countries have nuclear reactors for research purposes, which allow the production of technetium-99 m (Argentina, Chile, Mexico and Peru), while four (Argentina, Brazil, Cuba, and Mexico) assemble 99Mo-99mTc generators. As for the nuclear cardiology studies, about 80% of studies performed are gated SPECT myocardial perfusion imaging; less than 10% are multi-gated acquisition (mainly for evaluation of cardiac toxicity in cancer patients), and the other 10% correspond to other types of studies, such as viability detection, and adrenergic innervation studies with 123I-MIBG. Physical stress is preferred, when possible, based on the clinical condition of the patient. Regarding human resources, there is an average of 1.1 physicians and 1.3 technologists per γ camera, with 0.1 medical physicists and 0.1 radiopharmacists per center in the region. The future of nuclear cardiology in Latin America and the Caribbean is encouraging, with great potential and possibilities for growth. National, regional, and international cooperation including support from scientific societies and organizations such as International Atomic Energy Agency, American Society of Nuclear Cardiology, and Latin American Association of Biology and Nuclear Medicine Societies, as well as governmental commitment are key factors for the development of the specialty. A multimodality approach in cardiac imaging will contribute to a better management of patients with CVDs.
Assuntos
Técnicas de Imagem Cardíaca/estatística & dados numéricos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/epidemiologia , Cintilografia/estatística & dados numéricos , Revisão da Utilização de Recursos de Saúde , Cardiologia/estatística & dados numéricos , Região do Caribe/epidemiologia , Humanos , América Latina/epidemiologia , Medicina Nuclear/estatística & dados numéricos , PrevalênciaRESUMO
BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.
Assuntos
Cardiologia/normas , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada de Emissão/estatística & dados numéricos , Cardiologia/estatística & dados numéricos , Fidelidade a Diretrizes/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde , Humanos , Internacionalidade , América Latina/epidemiologia , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Padrões de Prática Médica/normas , Melhoria de Qualidade , Proteção Radiológica/normas , Tomografia Computadorizada de Emissão/normas , Revisão da Utilização de Recursos de SaúdeRESUMO
OBJECTIVE: To test the hypothesis that, in the initial evaluation of patients with suspected coronary artery disease (CAD), stress myocardial perfusion imaging (MPI) would result in less downstream testing than coronary computed tomographic angiography (CCTA). METHODS: In this international, randomized trial, mildly symptomatic patients with an intermediate likelihood of having CAD, and asymptomatic patients at intermediate risk of cardiac events, underwent either initial stress-rest MPI or CCTA. The primary outcome was downstream noninvasive or invasive testing at 6 months. Secondary outcomes included cumulative effective radiation dose (ERD) and costs at 12 months. RESULTS: We recruited 303 patients (151 MPI and 152 CTA) from 6 centers in 6 countries. The initial MPI was abnormal in 29% (41/143) and CCTA in 56% (79/141) of patients. Fewer patients undergoing initial stress-rest MPI had further downstream testing at 6 months (adjusted OR 0.51, 95% CI 0.28-0.91, P = 0.023). There was a small increase in the median cumulative ERD with MPI (9.6 vs. 8.8 mSv, P = 0.04), but no difference in costs between the two strategies at 12 months. CONCLUSION: In the management of patients with suspected CAD, a strategy of initial stress MPI is substantially less likely to require further downstream testing than initial testing with CCTA. TRIAL REGISTRATION: clinicaltrials.gov identification number NCT01368770.
Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Testes de Função Cardíaca/métodos , Programas de Rastreamento/métodos , Imagem de Perfusão do Miocárdio/métodos , Diagnóstico Precoce , Feminino , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.MethodsâandâResults:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.
Assuntos
Imagem de Perfusão do Miocárdio/efeitos adversos , Padrões de Prática Médica/normas , Exposição à Radiação/estatística & dados numéricos , Idoso , Ásia , Cardiologia/métodos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medicina Nuclear/métodos , Qualidade da Assistência à Saúde , Doses de Radiação , Tecnécio/administração & dosagem , Tálio/administração & dosagemRESUMO
BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.
Assuntos
Imagem de Perfusão do Miocárdio/efeitos adversos , Doses de Radiação , Exposição à Radiação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , OceaniaRESUMO
PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.
Assuntos
Técnicas de Imagem Cardíaca/métodos , Tomografia por Emissão de Pósitrons/métodos , Guias de Prática Clínica como Assunto , Doses de Radiação , Técnicas de Imagem Cardíaca/efeitos adversos , Técnicas de Imagem Cardíaca/instrumentação , Técnicas de Imagem Cardíaca/normas , Cardiologia/organização & administração , União Europeia , Medicina Nuclear/organização & administração , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/normas , Sociedades CientíficasRESUMO
The recent publication of the results of 3 small trials, and as many as 5 case reports on dogs producing clear and intelligible alerts in the presence of their owners' hypoglycemia, opens an intriguing clinical scenario for management of diabetes. The skill seems attributable to the ability of dogs to identify patterns in skin and breath odors as well as to understand and interpret visual cues from humans during hypoglycemia. Provided that further trials can confirm the findings, the use of diabetes alert dogs that are trained to detect the onset of hypoglycemia can be regarded as a fast, versatile, reliable, and cost-effective approach for safeguarding the health of individuals with diabetes.
Assuntos
Comportamento Animal , Ensaios Clínicos como Assunto , Diabetes Mellitus , Hipoglicemia/diagnóstico , Animais , Automonitorização da Glicemia/economia , Cães , Vínculo Humano-Animal , Humanos , Hipoglicemia/sangueRESUMO
AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.
Assuntos
Fidelidade a Diretrizes/normas , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Guias de Prática Clínica como Assunto/normas , Doses de Radiação , Exposição à Radiação/análise , Idoso , Cardiologia/normas , Protocolos Clínicos/normas , Estudos Transversais , Feminino , Saúde Global , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Tomografia por Emissão de Pósitrons/normas , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Prática Profissional/normas , Prática Profissional/estatística & dados numéricos , Qualidade da Assistência à Saúde/normas , Qualidade da Assistência à Saúde/estatística & dados numéricos , Análise de Regressão , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricosAssuntos
Betacoronavirus , Cardiologia , Infecções por Coronavirus/epidemiologia , Medicina Nuclear , Pneumonia Viral/epidemiologia , Guias de Prática Clínica como Assunto , COVID-19 , Teste para COVID-19 , Cardiologia/educação , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/prevenção & controle , Humanos , Laboratórios , Medicina Nuclear/educação , Pandemias/prevenção & controle , Equipamento de Proteção Individual , Pneumonia Viral/prevenção & controle , SARS-CoV-2 , Sociedades MédicasRESUMO
BACKGROUND: Transient post-ischemic LV dysfunction due to myocardial stunning in patients with coronary artery disease can be missed by conventional gated SPECT (GSPECT) acquisitions. The aim of this IAEA-sponsored multi-center study was to determine whether early post-exercise imaging is more likely to detect stunning than conventional without adversely affecting image quality or perfusion information. METHODS AND RESULTS: Patients undergoing exercise/rest GSPECT were enrolled in this international multicenter study. Post-exercise studies were acquired at 15 ± 5 minutes after radiotracer injection (Stress-1) and repeated at 60 ± 15 minutes (Stress-2). Rest studies (R) were acquired at 60 minutes post injection. A core laboratory quantitatively assessed perfusion pattern and LV blinded to the acquisition time. Ischemia was defined as summed stress score (SDS) ≥4, and stunning was defined as the difference between rest and post-stress LVEF (Δ-LVEF). In the 229 patients enrolled into the study, both image quality and perfusion information were similar between Stress-1 and Stress-2. Post-stress LVEF was associated with both ischemia and time of acquisition, with a significant correlation between SDS and Δ-LVEF, which was stronger at Stress-1 than Stress-2 in the ischemic compared to the non-ischemic population (r = 0.23 vs 0.08, P = 0.10). CONCLUSIONS: Early post-exercise imaging is feasible, and can potentially improve the detection of post-ischemic stunning without compromising image quality and perfusion data.
Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio Atordoado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/complicações , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/etiologia , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
An adult pet tawny owl (Strix aluco) presented to a veterinary hospital at Parma University with a history of head trauma. After a critical care protocol including thermal, oxygen and fluid support aimed at stabilizing the patient, a neurological examination was performed. During neurological evaluation, marked lethargy and an inability to rise from a recumbent position was noted. Anisocoria was also present, with a mydriatic left pupil exhibiting no pupillary light response (PLR) even on direct illumination of both eyes. On ocular fundus examination, retinal hemorrhage and retinal detachment were observed. Based on these clinical findings, a complete work-up was performed, including hematological exams and total body X-ray studies followed by a computed tomography (CT) scan. Additional examinations, such as brainstem auditory evoked response (BAER) measurement and flash visual evoked potential (FVEP) recording, were performed. FVEP measurements performed on the left eye exhibited no peaks in either series of stimulations, indicating an altered functional integration within the visual pathway. A CT scan revealed a large hypoattenuating lesion within the right cerebral hemisphere, suspected to be intraparenchymal edema. The BAER test demonstrated an altered trace consistent with brainstem involvement and left hypoacusis due to cranial nerve VIII deficiency. Head trauma can result in significant neurological impairments in birds, impacting their behavior, mobility, and cognitive abilities. FVEP recordings, BAER tests and CT scans may be useful diagnostic tools in clinical practice. Understanding the causes and neurologic presentation of avian traumas is essential for effective prevention, diagnosis and treatment of affected birds.
RESUMO
Quality Management Audits in Nuclear Medicine (QUANUM) is an initiative conceived by the International Atomic Energy Agency to enhance global standards in Nuclear Medicine practices. Acknowledging the intricate regulatory frameworks and the necessity for multidisciplinary collaboration, QUANUM has gained global acceptance, demonstrating widespread implementation and positive impacts on patient care. This manuscript critically evaluates the QUANUM program through the lens of quality improvement (QI), by employing established and validated QI tools. Our analysis identifies areas of conformance, underscores key strengths inherent to QUANUM, and pinpoints further learning opportunities for continuous enhancement. Additionally, we assert that the insights derived from scrutinizing this global project within Nuclear Medicine, have valuable implications for departments aspiring for establishing good quality management systems, thereby contributing to the improvement of patient care.