Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 137(5): 1111-9, 2012 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-22273712

RESUMO

Raman microscopy is employed to spectroscopically image biological cells previously exposed to fluorescently labelled polystyrene nanoparticles and, in combination with K-means clustering and principal component analysis (PCA), is demonstrated to be capable of localising the nanoparticles and identifying the subcellular environment based on the molecular spectroscopic signatures. The neutral nanoparticles of 50 nm or 100 nm, as characterised by dynamic light scattering, are shown to be non-toxic to a human lung adenocarcinoma cell-line (A549), according to a range of cytotoxicity assays including Neutral Red, Alamar Blue, Coomassie Blue and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Confocal fluorescence microscopy identifies intracellular fluorescence due to the nanoparticle exposure, but the fluorescence distribution is spatially diffuse, potentially due to detachment of the dye from the nanoparticles, and the technique fails to unambiguously identify the distribution of the nanoparticles within the cells. Raman spectroscopic mapping of the cells in combination with K-means cluster analysis is used to clearly identify and localise the polystyrene nanoparticles in exposed cells, based on their characteristic spectroscopic signatures. PCA identifies the local environment as rich in lipidic signatures which are associated with localisation of the nanoparticles in the endoplasmic reticulum. The importance of optimised cell growth conditions and fixation processes is highlighted. The preliminary study demonstrates the potential of the technique to unambiguously identify and locate nonfluorescent nanoparticles in cells and to probe not only the local environment but also changes in the cell metabolism which may be associated with cytotoxic responses.


Assuntos
Espaço Intracelular/química , Nanopartículas/análise , Nanopartículas/química , Análise Espectral Raman , Linhagem Celular Tumoral , Humanos , Espaço Intracelular/efeitos dos fármacos , Espaço Intracelular/metabolismo , Microscopia Confocal , Nanopartículas/toxicidade , Poliestirenos/química , Análise de Componente Principal
2.
J Biophotonics ; 11(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28700142

RESUMO

For several decades, a multitude of studies have documented the ability of Raman spectroscopy (RS) to differentiate between tissue types and identify pathological changes to tissues in a range of diseases. Furthermore, spectroscopists have illustrated that the technique is capable of detecting disease-specific alterations to tissue before morphological changes become apparent to the pathologist. This study draws comparisons between the information that is obtainable using RS alongside immunohistochemistry (IHC), since histological examination is the current GOLD standard for diagnosing a wide range of diseases. Here, Raman spectral maps were generated using formalin-fixed, paraffin-embedded colonic tissue sections from healthy patients and spectral signatures from principal components analysis (PCA) were compared with several IHC markers to confirm the validity of their localizations. PCA loadings identified a number of signatures that could be assigned to muscle, DNA and mucin glycoproteins and their distributions were confirmed with antibodies raised against anti-Desmin, anti-Ki67 and anti-MUC2, respectively. The comparison confirms that there is excellent correlation between RS and the IHC markers used, demonstrating that the technique is capable of detecting compositional changes in tissue in a label-free manner, eliminating the need for antibodies.


Assuntos
Antígenos/análise , Análise Espectral Raman/métodos , Colo/citologia , Formaldeído , Humanos , Inclusão em Parafina , Fixação de Tecidos
3.
J Raman Spectrosc ; 48(1): 119-125, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28163358

RESUMO

Raman spectroscopy (RS) is a powerful technique that permits the non-destructive chemical analysis of cells and tissues without the need for expensive and complex sample preparation. To date, samples have been routinely mounted onto calcium fluoride (CaF2) as this material possesses the desired mechanical and optical properties for analysis, but CaF2 is both expensive and brittle and this prevents the technique from being routinely adopted. Furthermore, Raman scattering is a weak phenomenon and CaF2 provides no means of increasing signal. For RS to be widely adopted, particularly in the clinical field, it is crucial that spectroscopists identify an alternative, low-cost substrate capable of providing high spectral signal to noise ratios with good spatial resolution. Results show that these desired properties are attainable when using mirrored stainless steel as a Raman substrate. When compared with CaF2, data show that stainless steel has a low background signal and provides an average signal increase of 1.43 times during tissue analysis and 1.64 times when analyzing cells. This result is attributed to a double-pass of the laser beam through the sample where the photons from the source laser and the forward scattered Raman signal are backreflected and retroreflected from the mirrored steel surface and focused towards collection optics. The spatial resolution on stainless steel is at least comparable to that on CaF2 and it is not compromised by the reflection of the laser. Steel is a fraction of the cost of CaF2 and the reflection and focusing of photons improve signal to noise ratios permitting more rapid mapping. The low cost of steel coupled with its Raman signal increasing properties and robust durability indicates that steel is an ideal substrate for biological and clinical RS as it possesses key advantages over routinely used CaF2. © 2016 The Authors. Journal of Raman Spectroscopy Published by John Wiley & Sons Ltd.

4.
Nat Protoc ; 11(4): 664-87, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26963630

RESUMO

Raman spectroscopy can be used to measure the chemical composition of a sample, which can in turn be used to extract biological information. Many materials have characteristic Raman spectra, which means that Raman spectroscopy has proven to be an effective analytical approach in geology, semiconductor, materials and polymer science fields. The application of Raman spectroscopy and microscopy within biology is rapidly increasing because it can provide chemical and compositional information, but it does not typically suffer from interference from water molecules. Analysis does not conventionally require extensive sample preparation; biochemical and structural information can usually be obtained without labeling. In this protocol, we aim to standardize and bring together multiple experimental approaches from key leaders in the field for obtaining Raman spectra using a microspectrometer. As examples of the range of biological samples that can be analyzed, we provide instructions for acquiring Raman spectra, maps and images for fresh plant tissue, formalin-fixed and fresh frozen mammalian tissue, fixed cells and biofluids. We explore a robust approach for sample preparation, instrumentation, acquisition parameters and data processing. By using this approach, we expect that a typical Raman experiment can be performed by a nonspecialist user to generate high-quality data for biological materials analysis.


Assuntos
Materiais Biocompatíveis/análise , Análise Espectral Raman/métodos , Animais , Coleta de Dados , Processamento Eletrônico de Dados , Mamíferos , Plantas , Manejo de Espécimes/métodos , Análise Espectral Raman/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA