Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Synchrotron Radiat ; 30(Pt 3): 650-654, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36952235

RESUMO

This work introduces a novel setup for computed tomography of heavy and bulky specimens at the SYRMEP beamline of the Italian synchrotron Elettra. All the key features of the setup are described and the first application to off-center computed tomography scanning of a human chest phantom (approximately 45 kg) as well as the first results for vertical helical acquisitions are discussed.


Assuntos
Síncrotrons , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
2.
J Synchrotron Radiat ; 29(Pt 1): 247-253, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34985442

RESUMO

Virtual histology is increasingly utilized to reconstruct the cell mechanisms underlying dental morphology for fragile fossils when physical thin sections are not permitted. Yet, the comparability of data derived from virtual and physical thin sections is rarely tested. Here, the results from archaeological human deciduous incisor physical sections are compared with virtual ones obtained by phase-contrast synchrotron radiation computed microtomography (SRµCT) of intact specimens using a multi-scale approach. Moreover, virtual prenatal daily enamel secretion rates are compared with those calculated from physical thin sections of the same tooth class from the same archaeological skeletal series. Results showed overall good visibility of the enamel microstructures in the virtual sections which are comparable to that of physical ones. The highest spatial resolution SRµCT setting (effective pixel size = 0.9 µm) produced daily secretion rates that matched those calculated from physical sections. Rates obtained using the lowest spatial resolution setup (effective pixel size = 2.0 µm) were higher than those obtained from physical sections. The results demonstrate that virtual histology can be applied to the investigated samples to obtain reliable and quantitative measurements of prenatal daily enamel secretion rates.


Assuntos
Fósseis , Síncrotrons , Esmalte Dentário/diagnóstico por imagem , Feminino , Humanos , Gravidez , Microtomografia por Raio-X , Raios X
3.
Proc Biol Sci ; 288(1963): 20212079, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34814754

RESUMO

Modern humans have a slow and extended period of childhood growth, but to what extent this ontogenetic pathway was present in Neanderthals is debated. Dental development, linked to the duration of somatic growth across modern primates, is the main source for information about growth and development in a variety of fossil primates, including humans. Studies of Neanderthal permanent teeth report a pace of development either similar to recent humans or relatively accelerated. Neanderthal milk teeth, which form and emerge before permanent teeth, provide an opportunity to determine which pattern was present at birth. Here we present a comparative study of the prenatal and early postnatal growth of five milk teeth from three Neanderthals (120 000-130 000 years ago) using virtual histology. Results reveal regions of their milk teeth formed quickly before birth and over a relatively short period of time after birth. Tooth emergence commenced towards the earliest end of the eruption schedules displayed by extant human children. Advanced dental development is consistent with expectations for Neanderthal infant feeding.


Assuntos
Hominidae , Homem de Neandertal , Dente , Animais , Croácia , Fósseis , Humanos
4.
J Synchrotron Radiat ; 28(Pt 2): 410-418, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33650552

RESUMO

It has been shown previously both in vitro and in vivo that microbeam irradiation (MBI) can control malignant tumour cells more effectively than the clinically established concepts of broad beam irradiation. With the aim to extend the international capacity for microbeam research, the first MBI experiment at the biomedical beamline SYRMEP of the Italian synchrotron facility ELETTRA has been conducted. Using a multislit collimator produced by the company TECOMET, arrays of quasi-parallel microbeams were successfully generated with a beam width of 50 µm and a centre-to-centre distance of 400 µm. Murine melanoma cell cultures were irradiated with a target dose of approximately 65 Gy at a mean photon energy of ∼30 keV with a dose rate of 70 Gy s-1 and a peak-to-valley dose of ∼123. This work demonstrated a melanoma cell reduction of approximately 80% after MBI. It is suggested that, while a high energy is essential to achieve high dose rates in order to deposit high treatment doses in a short time in a deep-seated target, for in vitro studies and for the treatment of superficial tumours a spectrum in the lower energy range might be equally suitable or even advantageous.


Assuntos
Fótons , Síncrotrons , Animais , Camundongos , Método de Monte Carlo
5.
Int J Mol Sci ; 22(23)2021 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-34884675

RESUMO

Tannin-furanic rigid foams are bio-based copolymers of tannin plant extract and furfuryl alcohol, promising candidates to replace synthetic insulation foams, as for example polyurethanes and phenolics, in eco-sustainable buildings thanks to their functional properties, such as lightness of the material and fire resistance. Despite their relevance as environmental-friendly alternatives to petroleum derivatives, many aspects of the polymerization chemistry still remain unclear. One of the open issues is on the spatial heterogeneity of the foam, i.e., whether the foam constituents prevalently polymerize in spatially segregated blocks or distribute almost homogenously in the foam volume. To address this matter, here we propose a multiscale FTIR study encompassing 1D FTIR spectroscopy, 2D FTIR imaging and 3D FTIR micro-tomography (FTIR-µCT) on tannin-furanic rigid foams obtained by varying the synthesis parameters in a controlled way. Thanks to the implementation of the acquisition and processing pipeline of FTIR-µCT, we were able for the first time to demonstrate that the polymer formulations influence the spatial organization of the foam at the microscale and, at the same time, prove the reliability of FTIR-µCT data by comparing 2D FTIR images and the projection of the 3D chemical images on the same plane.


Assuntos
Furanos/química , Taninos/química , Espectroscopia de Infravermelho com Transformada de Fourier , Microtomografia por Raio-X
6.
J Synchrotron Radiat ; 27(Pt 2): 503-506, 2020 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-32153291

RESUMO

The vertical intensity distribution of synchrotron-based X-ray beams usually has a Gaussian profile encompassing large intensity variations. For biomedical imaging applications this may entail sub-optimal dose distributions and large fluctuations in terms of image noise. Commonly, planar metallic filters coupled with absorbing slits systems are applied to adjust the delivered flux and to limit intensity variations, respectively. The latter results in a reduction of the effective beam size. A flattening filter that counterbalances the transverse inhomogeneity, while retaining a sufficient flux, has been developed in the context of a monochromatic phase-contrast breast computed tomography application, ongoing at the Elettra synchrotron facility. The implementation of the new filtration system results in homogeneous intensity (hence dose) distribution and signal-to-noise ratio across the imaged volume. Finally, and most importantly, it allows a wider portion of the beam to be used, directly translating into a major (∼40%) reduction of the overall scan time for samples requiring a field of view larger than the beam size (i.e. multiple translation steps).


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Mamografia/instrumentação , Doses de Radiação , Razão Sinal-Ruído , Síncrotrons
7.
Eur Radiol ; 30(5): 2740-2750, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31974689

RESUMO

OBJECTIVES: To evaluate and compare the image quality of propagation-based phase-contrast computed tomography (PB-CT) using synchrotron radiation and conventional cone-beam breast computed tomography (CBBCT) based on various radiological image quality criteria. METHODS: Eight excised breast tissue samples of various sizes and containing different lesion types were scanned using PB-CT at a synchrotron facility and using CBBCT at a university-affiliated breast imaging centre. PB-CT scans were performed at two different mean glandular dose (MGD) levels: standard (5.8 mGy) and low (1.5 mGy), for comparison with CBBCT scans at the standard MGD (5.8 mGy). Image quality assessment was carried out using six quality criteria and six independent medical imaging experts in a reading room with mammography workstations. The interobserver agreement between readers was evaluated using intraclass correlation coefficient (ICC), and image quality was compared between the two breast imaging modalities using the area under the visual grading characteristic curve (AUCVGC). RESULTS: Interobserver agreement between the readers showed moderate reliability for five image criteria (ICC: ranging from 0.488 to 0.633) and low reliability for one criterion (image noise) (ICC 0.307). For five image quality criteria (overall quality, perceptible contrast, lesion sharpness, normal tissue interfaces, and calcification visibility), both standard-dose PB-CT images (AUCVGC 0.958 to 1, p ≤ .05) and low dose PB-CT images (AUCVGC 0.785 to 0.834, p ≤ .05) were of significantly higher image quality than standard-dose CBBCT images. CONCLUSIONS: Synchrotron-based PB-CT can achieve a significantly higher radiological image quality at a substantially lower radiation dose compared with conventional CBBCT. KEY POINTS: • PB-CT using synchrotron radiation results in higher image quality than conventional CBBCT for breast imaging. • PB-CT using synchrotron radiation requires a lower radiation dose than conventional CBBCT for breast imaging. • PB-CT can help clinicians diagnose patients with breast cancer.


Assuntos
Doenças Mamárias/diagnóstico , Mama/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Mamografia/métodos , Síncrotrons , Feminino , Humanos , Doses de Radiação , Reprodutibilidade dos Testes
8.
J Synchrotron Radiat ; 26(Pt 2): 510-516, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30855262

RESUMO

In the case of single-distance propagation-based phase-contrast X-ray computed tomography with synchrotron radiation, the conventional reconstruction pipeline includes an independent 2D phase retrieval filtering of each acquired projection prior to the actual reconstruction. In order to compensate for the limited height of the X-ray beam or the small sensitive area of most modern X-ray photon-counting detectors, it is quite common to image large objects with a multi-stage approach, i.e. several acquisitions at different vertical positions of the sample. In this context, the conventional reconstruction pipeline may introduce artifacts at the margins of each vertical stage. This article presents a modified computational protocol where a post-reconstruction 3D volume phase retrieval is applied. By comparing the conventional 2D and the proposed 3D reconstructions of a large mastectomy specimen (9 cm in diameter and 3 cm in height), it is here shown that the 3D approach compensates for the multi-stage artifacts, it avoids refined projection stitching, and the image quality in terms of spatial resolution, contrast and contrast-to-noise ratio is preserved.

9.
J Synchrotron Radiat ; 26(Pt 4): 1343-1353, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274463

RESUMO

Breast computed tomography (BCT) is an emerging application of X-ray tomography in radiological practice. A few clinical prototypes are under evaluation in hospitals and new systems are under development aiming at improving spatial and contrast resolution and reducing delivered dose. At the same time, synchrotron-radiation phase-contrast mammography has been demonstrated to offer substantial advantages when compared with conventional mammography. At Elettra, the Italian synchrotron radiation facility, a clinical program of phase-contrast BCT based on the free-space propagation approach is under development. In this paper, full-volume breast samples imaged with a beam energy of 32 keV delivering a mean glandular dose of 5 mGy are presented. The whole acquisition setup mimics a clinical study in order to evaluate its feasibility in terms of acquisition time and image quality. Acquisitions are performed using a high-resolution CdTe photon-counting detector and the projection data are processed via a phase-retrieval algorithm. Tomographic reconstructions are compared with conventional mammographic images acquired prior to surgery and with histologic examinations. Results indicate that BCT with monochromatic beam and free-space propagation phase-contrast imaging provide relevant three-dimensional insights of breast morphology at clinically acceptable doses and scan times.


Assuntos
Mamografia/métodos , Microscopia de Contraste de Fase/métodos , Microtomografia por Raio-X/métodos , Compostos de Cádmio/química , Feminino , Humanos , Síncrotrons , Telúrio/química
10.
J Synchrotron Radiat ; 25(Pt 6): 1827-1832, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30407195

RESUMO

In-line free propagation phase-contrast synchrotron tomography of the lungs has been shown to provide superior image quality compared with attenuation-based computed tomography (CT) in small-animal studies. The present study was performed to prove the applicability on a human-patient scale using a chest phantom with ventilated fresh porcine lungs. Local areas of interest were imaged with a pixel size of 100 µm, yielding a high-resolution depiction of anatomical hallmarks of healthy lungs and artificial lung nodules. Details like fine spiculations into surrounding alveolar spaces were shown on a micrometre scale. Minor differences in artificial lung nodule density were detected by phase retrieval. Since we only applied a fraction of the X-ray dose used for clinical high-resolution CT scans, it is believed that this approach may become applicable to the detailed assessment of focal lung lesions in patients in the future.


Assuntos
Pulmão/diagnóstico por imagem , Imagens de Fantasmas , Síncrotrons , Algoritmos , Pontos de Referência Anatômicos , Animais , Humanos , Processamento de Imagem Assistida por Computador , Técnicas In Vitro , Estudo de Prova de Conceito , Suínos , Tomografia Computadorizada por Raios X
11.
J Hum Evol ; 74: 96-113, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24852385

RESUMO

Fieldwork performed during the last 15 years in various Early Pleistocene East African sites has significantly enlarged the fossil record of Homo erectus sensu lato (s.l.). Additional evidence comes from the Danakil Depression of Eritrea, where over 200 late Early to early Middle Pleistocene sites have been identified within a ∼1000 m-thick sedimentary succession outcropping in the Dandiero Rift Basin, near Buia. Along with an adult cranium (UA 31), which displays a blend of H. erectus-like and derived morpho-architectural features and three pelvic remains, two isolated permanent incisors (UA 222 and UA 369) have also been recovered from the 1 Ma (millions of years ago) Homo-bearing outcrop of Uadi Aalad. Since 2010, our surveys have expanded to the nearby (4.7 km) site of Mulhuli-Amo (MA). This is a fossiliferous area that has been preliminarily surveyed because of its exceptional concentration of Acheulean stone tools. So far, the site has yielded 10 human remains, including the unworn crown of a lower permanent molar (MA 93). Using diverse analytical tools (including high resolution µCT and µMRI), we analysed the external and internal macromorphology and microstructure of the three specimens, and whenever possible compared the results with similar evidence from early Homo, H. erectus s.l., H. antecessor, H. heidelbergensis (from North Africa), Neanderthals and modern humans. We also assessed the UA 369 lower incisor from Uadi Aalad for root completion timing and showed that it compares well with data for root apex closure in modern human populations.


Assuntos
Fósseis/anatomia & histologia , Hominidae/anatomia & histologia , Incisivo/anatomia & histologia , Dente Molar/anatomia & histologia , Animais , Eritreia , Fósseis/diagnóstico por imagem , Imageamento por Ressonância Magnética , Microtomografia por Raio-X
12.
Sci Rep ; 14(1): 6024, 2024 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-38472259

RESUMO

The peopling of Europe during the Middle Pleistocene is a debated topic among paleoanthropologists. Some authors suggest the coexistence of multiple human lineages in this period, while others propose a single evolving lineage from Homo heidelbergensis to Homo neanderthalensis. The recent reassessment of the stratigraphy at the Sedia del Diavolo (SdD) site (Latium, Italy), now dated to the beginning of marine isotope stage (MIS) 8, calls for a revision of the human fossils from the site. In this paper, we present the morphometric, biomechanical and palaeopathological study of the second right metatarsal SdD2, to both re-evaluate its taxonomical affinities and possibly determine the levels of physical activity experienced by the individual during lifetime. Results demonstrate the persistence of archaic features in SdD2 suggesting new insights into the technology and hunting strategies adopted by Homo between MIS 9 and MIS 8.


Assuntos
Hominidae , Ossos do Metatarso , Homem de Neandertal , Animais , Humanos , Cidade de Roma , Itália , Fósseis , Evolução Biológica
13.
Front Med (Lausanne) ; 11: 1338846, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410752

RESUMO

Introduction: Synchrotron-based propagation-based imaging (PBI) is ideally suited for lung imaging and has successfully been applied in a variety of in vivo small animal studies. Virtually all these experiments were tailored to achieve extremely high spatial resolution close to the alveolar level while delivering high x-ray doses that would not permit longitudinal studies. However, the main rationale for performing lung imaging studies in vivo in small animal models is the ability to follow disease progression or monitor treatment response in the same animal over time. Thus, an in vivo imaging strategy should ideally allow performing longitudinal studies. Methods: Here, we demonstrate our findings of using PBI-based planar and CT imaging with two different detectors-MÖNCH 0.3 direct conversion detector and a complementary metal-oxide-semiconductor (CMOS) detector (Photonics Science)-in an Ovalbumin induced experimental allergic airway disease mouse model in comparison with healthy controls. The mice were imaged free breathing under isoflurane anesthesia. Results: At x-ray dose levels below those once used by commercial small animal CT devices at similar spatial resolutions, we were able to resolve structural changes at a pixel size down to 25 µm and demonstrate the reduction in elastic recoil in the asthmatic mice in cinematic planar x-ray imaging with a frame rate of up to 100 fps. Discussion: Thus, we believe that our approach will permit longitudinal small animal lung disease studies, closely following the mice over longer time spans.

14.
Opt Express ; 21(1): 647-61, 2013 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-23388958

RESUMO

We present a quantitative, non-interferometric, X-ray differential phase contrast imaging technique based on the edge illumination principle. We derive a novel phase retrieval algorithm which requires only two images to be acquired and verify the technique experimentally using synchrotron radiation. The technique is useful for planar imaging but is expected to be important for quantitative phase tomography also. The properties and limitations of the technique are studied in detail.

15.
Appl Opt ; 52(28): 6940-7, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24085208

RESUMO

We derive a Fourier formulation of coded-aperture x-ray phase-contrast imaging, based on the wave theory of optics in the Fresnel approximation. We use this model to develop a flexible, efficient, and general simulation algorithm that can be easily adapted to other implementations of x-ray phase contrast imaging. Likewise, the algorithm enables a simple extension to 2D aperture designs, different acquisition schemes, etc. Problems related to numerical implementation of the algorithm are analyzed in detail, and simple rules are derived that enable us to avoid or at least mitigate them. Finally, comparisons with experimental data and data obtained with a different simulation algorithm are presented to validate the model and demonstrate its advantages in practical implementations. This also enabled us to demonstrate an increase in computational speed of more than one order of magnitude over a previous algorithm.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Difração de Raios X/métodos , Difração de Raios X/instrumentação
16.
Sci Rep ; 13(1): 4788, 2023 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-36959233

RESUMO

Absorption-based clinical computed tomography (CT) is the current imaging method of choice in the diagnosis of lung diseases. Many pulmonary diseases are affecting microscopic structures of the lung, such as terminal bronchi, alveolar spaces, sublobular blood vessels or the pulmonary interstitial tissue. As spatial resolution in CT is limited by the clinically acceptable applied X-ray dose, a comprehensive diagnosis of conditions such as interstitial lung disease, idiopathic pulmonary fibrosis or the characterization of small pulmonary nodules is limited and may require additional validation by invasive lung biopsies. Propagation-based imaging (PBI) is a phase sensitive X-ray imaging technique capable of reaching high spatial resolutions at relatively low applied radiation dose levels. In this publication, we present technical refinements of PBI for the characterization of different artificial lung pathologies, mimicking clinically relevant patterns in ventilated fresh porcine lungs in a human-scale chest phantom. The combination of a very large propagation distance of 10.7 m and a photon counting detector with [Formula: see text] pixel size enabled high resolution PBI CT with significantly improved dose efficiency, measured by thermoluminescence detectors. Image quality was directly compared with state-of-the-art clinical CT. PBI with increased propagation distance was found to provide improved image quality at the same or even lower X-ray dose levels than clinical CT. By combining PBI with iodine k-edge subtraction imaging we further demonstrate that, the high quality of the calculated iodine concentration maps might be a potential tool for the analysis of lung perfusion in great detail. Our results indicate PBI to be of great value for accurate diagnosis of lung disease in patients as it allows to depict pathological lesions non-invasively at high resolution in 3D. This will especially benefit patients at high risk of complications from invasive lung biopsies such as in the setting of suspected idiopathic pulmonary fibrosis (IPF).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Animais , Suínos , Humanos , Raios X , Pulmão/diagnóstico por imagem , Pulmão/patologia , Tomografia Computadorizada por Raios X/métodos , Doenças Pulmonares Intersticiais/patologia , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Fibrose Pulmonar Idiopática/patologia , Imagens de Fantasmas
17.
J Synchrotron Radiat ; 19(Pt 5): 836-45, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22898966

RESUMO

Synchrotron-radiation computed tomography has been applied in many research fields. Here, PITRE (Phase-sensitive X-ray Image processing and Tomography REconstruction) and PITRE_BM (PITRE Batch Manager) are presented. PITRE supports phase retrieval for propagation-based phase-contrast imaging/tomography (PPCI/PPCT), extracts apparent absorption, refractive and scattering information of diffraction enhanced imaging (DEI), and allows parallel-beam tomography reconstruction for conventional absorption CT data and for PPCT phase retrieved and DEI-CT extracted information. PITRE_BM is a batch processing manager for PITRE: it executes a series of tasks, created via PITRE, without manual intervention. Both PITRE and PITRE_BM are coded in Interactive Data Language (IDL), and have a user-friendly graphical user interface. They are freeware and can run on Microsoft Windows systems via IDL Virtual Machine, which can be downloaded for free and does not require a license. The data-processing principle and some examples of application will be presented.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
18.
PLoS One ; 17(8): e0272023, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35925896

RESUMO

The investigation of jellyfish gastrovascular systems mainly focused on stain injections and dissections, negatively affected by thickness and opacity of the mesoglea. Therefore, descriptions are incomplete and data about tridimensional structures are scarce. In this work, morphological and functional anatomy of the gastrovascular system of Rhizostoma pulmo (Macri 1778) was investigated in detail with innovative techniques: resin endocasts and 3D X-ray computed microtomography. The gastrovascular system consists of a series of branching canals ending with numerous openings within the frilled margins of the oral arms. Canals presented a peculiar double hemi-canal structure with a medial adhesion area which separates centrifugal and centripetal flows. The inward flow involves only the "mouth" openings on the internal wing of the oral arm and relative hemi-canals, while the outward flow involves only the two outermost wings' hemi-canals and relative "anal" openings on the external oral arm. The openings differentiation recalls the functional characteristics of a through-gut apparatus. We cannot define the gastrovascular system in Rhizostoma pulmo as a traditional through-gut, rather an example of adaptive convergence, that partially invalidates the paradigm of a single oral opening with both the uptake and excrete function.


Assuntos
Cnidários , Cifozoários , Animais , Cifozoários/química , Microtomografia por Raio-X
19.
Radiology ; 259(3): 684-94, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21436089

RESUMO

PURPOSE: To prospectively evaluate the diagnostic contribution of mammography with synchrotron radiation in patients with questionable or suspicious breast abnormalities identified at combined digital mammography (DM) and ultrasonography (US). MATERIALS AND METHODS: The ethics committee approved this prospective study, and written informed consent was obtained from all patients. Mammography with synchrotron radiation was performed with a phase-detection technique at a synchrotron radiation laboratory. Forty-nine women who met at least one of the inclusion criteria (palpable mass, focal asymmetry, architectural distortion, or equivocal or suspicious mass at DM; none clarified at US) were enrolled. Forty-seven women (mean age, 57.8 years ± 8.8 [standard deviation]; age range, 43-78 years) completed the study protocol, which involved biopsy or follow-up for 1 year as the reference standard. Breast Imaging Reporting and Data System (BI-RADS) scores of 1-3 were considered to indicate a negative result, while scores 4-5 were considered to indicate a positive result. The visibility of breast abnormalities and the glandular parenchymal structure at DM and at mammography with synchrotron radiation was compared by using the Wilcoxon signed rank test. RESULTS: In 29 of the 31 patients with a final diagnosis of benign entity, mammography with synchrotron radiation yielded BI-RADS scores of 1-3. In 13 of the remaining 16 patients with a final diagnosis of malignancy, mammography with synchrotron radiation yielded BI-RADS scores of 4-5. Therefore, a sensitivity of 81% (13 of 16 patients) and a specificity of 94% (29 of 31 patients) were achieved with use of the described BI-RADS dichotomization system. CONCLUSION: These study results suggest that mammography with synchrotron radiation can be used to clarify cases of questionable or suspicious breast abnormalities identified at DM. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100745/-/DC1.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Síncrotrons , Adulto , Idoso , Biópsia , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade , Estatísticas não Paramétricas
20.
Phys Med Biol ; 65(5): 055016, 2020 03 06.
Artigo em Inglês | MEDLINE | ID: mdl-31995530

RESUMO

K-edge subtraction (KES) imaging is a technique able to map a specific element such as e.g. a contrast agent within the tissues, by exploiting the sharp rise of its absorption coefficient at the K-edge energy. Whereas mainly explored at synchrotron radiation sources, the energy discrimination properties of modern x-ray photon counting detectors (XPCDs) pave the way for an implementation of single-shot KES imaging with conventional polychromatic sources. In this work we present an x-ray CT imaging system based on the innovative Pixie-III detector and discrete reconstruction. The results reported here show that a reliable automatic localization of Barium (above a certain concentration) is possible with a few dozens of tomographic projections for a volume having an axial slice of 512 [Formula: see text] 512 pixels. The final application is a routine high-fidelity 3D mapping of a specific element ready for further morphological quantification by means of x-ray CT with potential promising applications in vivo.


Assuntos
Neoplasias da Mama/patologia , Processamento de Imagem Assistida por Computador/métodos , Fótons , Síncrotrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Animais , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Camundongos , Células Tumorais Cultivadas , Raios X , Ensaios Antitumorais Modelo de Xenoenxerto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA