Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Indoor Air ; 29(4): 686-697, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30921480

RESUMO

We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ) parameters, including carbon monoxide (CO), nitrogen dioxide (NO2 ), formaldehyde (CH2 O), selected volatile organic compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX), radon, and microbial content in settled dust were measured before and after the retrofits. After the retrofits, heating energy consumption decreased by an average of 24% and 49% in Finnish and Lithuanian buildings, respectively. After the retrofits of Finnish buildings, there was a significant increase in BTEX concentrations (estimated mean increase of 2.5 µg/m3 ), whereas significant reductions were seen in fungal (0.6-log reduction in cells/m2 /d) and bacterial (0.6-log reduction in gram-positive and 0.9-log reduction in gram-negative bacterial cells/m2 /d) concentrations. In Lithuanian buildings, radon concentrations were significantly increased (estimated mean increase of 13.8 Bq/m3 ) after the retrofits. Mechanical ventilation was associated with significantly lower CH2 O concentrations in Finnish buildings. The results and recommendations presented in this paper can inform building retrofit studies and other programs and policies aimed to improve indoor environment and health.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/prevenção & controle , Conservação de Recursos Energéticos/métodos , Ventilação , Microbiologia do Ar , Poeira/análise , Ambiente Controlado , Monitoramento Ambiental , Finlândia , Habitação , Humanos , Lituânia , Ventilação/métodos
2.
Build Environ ; 46(11): 2303-2313, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21874085

RESUMO

Asthma can be exacerbated by environmental factors including airborne particulate matter (PM) and environmental tobacco smoke (ETS). We report on a study designed to characterize PM levels and the effectiveness of filters on pollutant exposures of children with asthma. 126 households with an asthmatic child in Detroit, Michigan, were recruited and randomized into control or treatment groups. Both groups received asthma education; the latter also received a free-standing high efficiency air filter placed in the child's bedroom. Information regarding the home, emission sources, and occupant activities was obtained using surveys administered to the child's caregiver and a household inspection. Over a one-week period, we measured PM, carbon dioxide (CO(2)), environmental tobacco smoke (ETS) tracers, and air exchange rates (AERs). Filters were installed at midweek. Before filter installation, PM concentrations averaged 28 µg m(-3), number concentrations averaged 70,777 and 1,471 L(-1) in 0.3-1.0 and 1-5 µm size ranges, respectively, and the median CO(2) concentration was 1,018 ppm. ETS tracers were detected in 23 of 38 homes where smoking was unrestricted and occupants included smokers and, when detected, PM concentrations were elevated by an average of 15 µg m(-3). Filter use reduced PM concentrations by an average of 69 to 80%. Simulation models representing location conditions show that filter air flow, room volume and AERs are the key parameters affecting PM removal, however, filters can achieve substantial removal in even "worst" case applications. While PM levels in homes with asthmatic children can be high, levels can be dramatically reduced using filters.

3.
Sci Total Environ ; 621: 398-406, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29190562

RESUMO

Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO2) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use.

4.
Environ Int ; 79: 74-84, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25797585

RESUMO

Sixteen existing multi-family buildings (94 apartments) in Finland and 20 (96 apartments) in Lithuania were investigated prior to their renovation in order to develop and test out a common protocol for the indoor environmental quality (IEQ) assessment, and to assess the potential for improving IEQ along with energy efficiency. Baseline data on buildings, as well as data on temperature (T), relative humidity (RH), carbon dioxide (CO2), carbon monoxide (CO), particulate matter (PM), nitrogen dioxide (NO2), formaldehyde, volatile organic compounds (VOCs), radon, and microbial content in settled dust were collected from each apartment. In addition, questionnaire data regarding housing quality and health were collected from the occupants. The results indicated that most measured IEQ parameters were within recommended limits. However, different baselines in each country were observed especially for parameters related to thermal conditions and ventilation. Different baselines were also observed for the respondents' satisfaction with their residence and indoor air quality, as well as their behavior related to indoor environment. In this paper, we present some evidence for the potential in improving IEQ along with energy efficiency in the current building stock, followed by discussion of possible IEQ indicators and development of the assessment protocol.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Habitação/normas , Dióxido de Carbono/análise , Monóxido de Carbono/análise , Monitoramento Ambiental/métodos , Finlândia , Formaldeído/análise , Humanos , Lituânia , Dióxido de Nitrogênio/análise , Material Particulado/análise , Ventilação/normas , Compostos Orgânicos Voláteis/análise
5.
Air Qual Atmos Health ; 6(4): 759-767, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24436726

RESUMO

This study characterizes the use of HEPA air filters provided to 89 households participating in an intervention study investigating the respiratory health of children with asthma. Freestanding filters were placed in the child's bedroom and monitored continuously for nearly a year in each household. Filter use was significantly affected by study phase, season and monitoring week. During the "intensive" weeks when a community education worker and a field technician visited the household, the use rate averaged 70±33%. During season-long "non-intensive" periods between seasonal visits, use dropped to 34±30%. Filter use rapidly decreased during the 3 to 4 weeks following each intensive, was slightly higher in spring, summer, and in the evening and at night when the child was likely to be home, although households did not follow consistent diurnal patterns. While participants expressed an understanding of the benefits of filter use and reported good experiences with them, use rates were low, particularly during unobserved non-intensive periods. The provision of freestanding air filters to individuals or households must be considered an active intervention that requires monitoring and evaluation, otherwise unknown and unexpected patterns of filter use may alter and possibly bias results due to exposure misclassification.

6.
Int J Environ Res Public Health ; 9(12): 4639-61, 2012 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-23235286

RESUMO

Air change rates (ACRs) and interzonal flows are key determinants of indoor air quality (IAQ) and building energy use. This paper characterizes ACRs and interzonal flows in 126 houses, and evaluates effects of these parameters on IAQ. ACRs measured using weeklong tracer measurements in several seasons averaged 0.73 ± 0.76 h(-1) (median = 0.57 h(-1), n = 263) in the general living area, and much higher, 1.66 ± 1.50 h(-1) (median = 1.23 h(-1), n = 253) in bedrooms. Living area ACRs were highest in winter and lowest in spring; bedroom ACRs were highest in summer and lowest in spring. Bedrooms received an average of 55 ± 18% of air from elsewhere in the house; the living area received only 26 ± 20% from the bedroom. Interzonal flows did not depend on season, indoor smoking or the presence of air conditioners. A two-zone IAQ model calibrated for the field study showed large differences in pollutant levels between the living area and bedroom, and the key parameters affecting IAQ were emission rates, emission source locations, air filter use, ACRs, interzonal flows, outdoor concentrations, and PM penetration factors. The single-zone models that are commonly used for residences have substantial limitations and may inadequately represent pollutant concentrations and exposures in bedrooms and potentially other environments other where people spend a substantial fraction of time.


Assuntos
Movimentos do Ar , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental/métodos , Habitação , Pesquisa Participativa Baseada na Comunidade , Michigan , Modelos Teóricos , Estações do Ano , Sensibilidade e Especificidade , Tempo (Meteorologia)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA