Front Syst Neurosci ; 14: 79, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33328910

RESUMO

Background: Quality of life measurements indicate that independent performance of activities of daily living, such as reaching to manipulate objects, is a high priority of individuals living with motor impairments due to spinal cord injury (SCI). In a small number of research participants with SCI, electrical stimulation applied to the dorsal epidural surface of the spinal cord, termed epidural spinal electrical stimulation (ES), has been shown to improve motor functions, such as standing and stepping. However, the impact of ES on seated reaching performance, as well as the approach to identifying stimulation parameters that improve reaching ability, have yet to be described. Objective: Herein, we characterize the effects of ES on seated reaching performance in two participants with chronic, complete loss of motor and sensory functions below thoracic-level SCI. Additionally, we report the effects of delivering stimulation to discrete cathode/anode locations on a 16-contact electrode array spanning the lumbosacral spinal segments on reach distance while participants were seated on a mat and/or in their wheelchair. Methods: Two males with mid-thoracic SCI due to trauma, each of which occurred more than 3 years prior to study participation, were enrolled in a clinical trial at Mayo Clinic, Rochester, MN, USA. Reaching performance was assessed, with and without ES, at several time points throughout the study using the modified functional reach test (mFRT). Altogether, participant 1 performed 1,164 reach tests over 26-time points. Participant 2 performed 480 reach tests over 17-time points. Results: Median reach distances during ES were higher for both participants compared to without ES. Forward reach distances were greater than lateral reach distances in all environments, mat or wheelchair, for both participants. Stimulation delivered in the caudal region of the array resulted in improved forward reach distance compared to stimulation in the rostral region. For both participants, when stimulation was turned off, no significant changes in reach distance were observed throughout the study. Conclusion: ES enhanced seated reaching-performance of individuals with chronic SCI. Additionally, electrode configurations delivering stimulation in caudal regions of the lumbosacral spinal segments may improve reaching ability compared to rostral regions.

2.
Artigo em Inglês | MEDLINE | ID: mdl-25571566

RESUMO

A detailed design, fabrication, characterization and test of a flexible multi-site platinum/polyimide based electrode array for electrical epidural stimulation in spinal cord prosthesis is described in this paper. Carefully designed 8.4 µm-thick structure fabrication flow achieves an electrode surface modification with 3.8 times enhanced effective surface area without extra process needed. Measured impedance and phase of two type of electrodes are 2.35±0.21 KΩ and 2.10±0.11 KΩ, -34.25±8.07° and -27.71±8.27° at 1K Hz, respectively. The fabricated arrays were then in-vitro tested by a multichannel neural stimulation system in physiological saline to validate the capability for electrical stimulation. The measured channel isolation on adjacent electrode is about -34dB. Randles cell model was used to investigate the charging waveforms, the model parameters were then extracted by various methods. The measured charge transfer resistance, double layer capacitance, and solution resistance are 1.9 KΩ, 220 nF and 15 KΩ, respectively. The results show that the fabricated array is applicable for electrical stimulation with well characterized parameters. Combined with a multichannel stimulator, this system provides a full solution for versatile neural stimulation applications.


Assuntos
Estimulação Elétrica/instrumentação , Eletrodos Implantados , Espaço Epidural/fisiologia , Processamento de Sinais Assistido por Computador , Medula Espinal/fisiologia , Animais , Capacitância Elétrica , Impedância Elétrica , Estimulação Elétrica/métodos , Desenho de Equipamento , Teste de Materiais , Microscopia de Força Atômica , Modelos Teóricos , Neurônios/fisiologia , Polímeros/química , Próteses e Implantes , Ratos
3.
J Appl Physiol (1985) ; 110(3): 807-19, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21164150

RESUMO

The orientation of muscle fibers influences the physiological cross-sectional area, the relationship between fiber shortening and aponeurosis shear, and the total force produced by the muscle. Such architectural parameters are challenging to determine particularly in vivo in multicompartment structures such as the human soleus with a complex arrangement of muscle fibers. The objective of this study was to map the fiber architecture of the human soleus in vivo at rest in both neutral and plantarflexed ankle positions using an MRI-based method of diffusion tensor imaging (DTI). Six subjects were imaged at 3 Tesla with the foot at rest in the two ankle positions. Eigenvalues, fractional anisotropy (FA), and eigenvector orientations of fibers in the different soleus subcompartments were evaluated after denoising of the diffusion tensor. The fiber architecture from DTI was similar to earlier studies based on a 3D fiber model from cadavers. The three eigenvalues of the diffusion tensor increased by ∼14% on increasing the joint plantarflexion angle in all of the soleus subcompartments, whereas FA showed a trend to decrease in the posterior and marginal soleus and to increase in the anterior soleus. The angle change in the lead eigenvector between the two foot positions was significant: ∼41° for the posterior soleus and ∼48° for the anterior soleus. Fibers tracked from the subcompartments support these changes seen in the eigenvector orientations. DTI-derived, subject-specific, muscle morphological data could potentially be used to model a more complete description of muscle performance and changes from disease.


Assuntos
Articulação do Tornozelo/anatomia & histologia , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Anatômicos , Fibras Musculares Esqueléticas/citologia , Músculo Esquelético/anatomia & histologia , Adulto , Simulação por Computador , Feminino , Humanos , Masculino