Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Psychol Med ; 48(5): 751-764, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28933314

RESUMO

BACKGROUND: Cognitive remediation (CR) training has emerged as a promising approach to improving cognitive deficits in schizophrenia and related psychosis. The limited availability of psychological services for psychosis is a major barrier to accessing this intervention however. This study investigated the effectiveness of a low support, remotely accessible, computerised working memory (WM) training programme in patients with psychosis. METHODS: Ninety patients were enrolled into a single blind randomised controlled trial of CR. Effectiveness of the intervention was assessed in terms of neuropsychological performance, social and occupational function, and functional MRI 2 weeks post-intervention, with neuropsychological and social function again assessed 3-6 months post-treatment. RESULTS: Patients who completed the intervention showed significant gains in both neuropsychological function (measured using both untrained WM and episodic task performance, and a measure of performance IQ), and social function at both 2-week follow-up and 3-6-month follow-up timepoints. Furthermore, patients who completed MRI scanning showed improved resting state functional connectivity relative to patients in the placebo condition. CONCLUSIONS: CR training has already been shown to improve cognitive and social function in patient with psychosis. This study demonstrates that, at least for some chronic but stable outpatients, a low support treatment was associated with gains that were comparable with those reported for CR delivered entirely on a 1:1 basis. We conclude that CR has potential to be delivered even in services in which psychological supports for patients with psychosis are limited.


Assuntos
Disfunção Cognitiva/reabilitação , Remediação Cognitiva/métodos , Memória de Curto Prazo/fisiologia , Avaliação de Resultados em Cuidados de Saúde , Transtornos Psicóticos/reabilitação , Esquizofrenia/reabilitação , Telemedicina/métodos , Adulto , Disfunção Cognitiva/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Transtornos Psicóticos/complicações , Esquizofrenia/complicações , Método Simples-Cego , Terapia Assistida por Computador/métodos
2.
Age Ageing ; 44(4): 655-61, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25716898

RESUMO

BACKGROUND: older subjects may require higher baseline blood pressures to maintain cerebral perfusion. We investigated whether episodic hypotension is associated with tissue infarction in subjects with syncopal symptoms at stroke onset. METHODS: over 30 months, all acute strokes/TIAs were prospectively screened for symptoms of syncope or presyncope at stroke onset. Subjects with severe large vessel stenosis were excluded, while cases were referred for syncope unit investigation. All underwent 1.5 T MRI acutely, and suspected borderzone infarctions (BZI) were confirmed through Matlab-derived perfusion software. Case-control comparison was derived from stroke controls with no prior syncope history. RESULTS: thirty-eight of 772 stroke patients described presyncope or syncope at stroke onset and had patent large vessels (4.9% of all strokes). Median age was 72 years (IQR 21.4). Twenty-two patients (58%) were prescribed antihypertensive agents at symptom onset. Twenty-six (68.4%) reported focal neurology <24 h in duration. 63.2% (n = 24) of cases reported prior syncope history, compared with 33% (N = 103) of controls, P < 0.001. Cases exhibited greater orthostatic BP drop than controls, P < 0.05 Twenty-four patients were diagnosed with vasovagal syncope through head-up tilt symptom reproduction, 9 with orthostatic hypotension, 4 with cardiac syncope and 1 with carotid sinus syndrome. Nineteen (50%) patients had an acute infarct on MRI, 14 of these were in the arterial borderzone (73.6%). The BZI group were significantly older than the non-BZI group, 79.2 yrs versus 63.3 yrs, P = 0.002. CONCLUSION: subjects reporting hypotensive symptoms at stroke onset have a higher prevalence of borderzone infarction, despite being normotensive or hypertensive at baseline.


Assuntos
Pressão Sanguínea/fisiologia , Hipotensão/complicações , Ataque Isquêmico Transitório/etiologia , Acidente Vascular Cerebral/etiologia , Síncope/complicações , Doença Aguda , Idoso , Estenose das Carótidas , Feminino , Seguimentos , Humanos , Hipotensão/fisiopatologia , Ataque Isquêmico Transitório/diagnóstico , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/diagnóstico , Síncope/diagnóstico , Síncope/fisiopatologia , Fatores de Tempo , Tomografia Computadorizada por Raios X
3.
Am J Med Genet B Neuropsychiatr Genet ; 159B(5): 537-48, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22585743

RESUMO

Experimental studies support a neurotrophic hypothesis of major depressive disorder (MDD). The aim of this study was to determine the effect of Val66Met brain-derived neurotrophic factor (BDNF) polymorphism on the white matter fiber tracts connecting hippocampus and amygdala with the prefrontal lobe in a sample of patients with MDD and healthy controls. Thirty-seven patients with MDD and 42 healthy volunteers were recruited. Diffusion tensor imaging (DTI) data with 61 diffusion directions were obtained with MRI 3 Tesla scanner. Deterministic tractography was applied with ExploreDTI and Val66Met BDNF SNP (rs6265) was genotyped. Fiber tracts connecting the hippocampus and amygdala with the prefrontal lobe, namely uncinate fasciculus (UF), fornix, and cingulum were analyzed. A significant interaction was found in the UF between BDNF alleles and diagnosis. Patients carrying the BDNF met-allele had smaller fractional anisotropy (FA) in the UF compared to those patients homozygous for val-allele and compared to healthy subjects carrying the met-allele. A significant three-way interaction was detected between region of the cingulum (dorsal, rostral, and parahippocampal regions), brain hemisphere and BDNF genotype. Larger FA was detectable in the left rostral cingulum for met-allele carriers when compared to val/val alelle carriers. We provide evidence for the importance of the neurotrophic involvement in limbic and prefrontal connections. The met-allele of the BDNF polymorphism seems to render subjects more vulnerable for dysfunctions associated with the UF, a tract known to be related to negative emotional-cognitive processing bias, declarative memory problems, and autonoetic self awareness.


Assuntos
Alelos , Fator Neurotrófico Derivado do Encéfalo/genética , Encéfalo/patologia , Transtorno Depressivo Maior/genética , Transtorno Depressivo Maior/patologia , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único/genética , Adolescente , Adulto , Idoso , Anisotropia , Estudos de Casos e Controles , Demografia , Transtorno Depressivo Maior/tratamento farmacológico , Imagem de Tensor de Difusão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
Phys Med ; 94: 65-74, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34998134

RESUMO

PURPOSE: Contrast-detail (C-D) and anechoic-target (A-T) detectability are measures of an ultrasound scanner's ability to image lesions of varying contrast and size from background tissue and, as such, they are important tools for grading the imaging capabilities of ultrasound scanners. The objective of this study was to develop a range of contrast- and anechoic-detail phantoms with clinically relevant lesions, of various contrast and sizes, for performance testing of breast ultrasound equipment. METHODS: Tissue mimicking materials that represent the acoustic properties of breast fibroglandular tissue were produced and moulded to construct a range of C-D and A-T phantoms. Two phantom designs were produced, containing cylindrical and spherical targets. Both phantom types were constructed with contrast targets covering the range anechoic, -1, -2, -3 and -4 dB, with lesion diameters of 1-4 mm, positioned at four clinically relevant depths (10, 25, 40 and 55 mm). An image analysis program was developed to objectively analyse the lesion images and to determine the lesion-signal-noise-ratio (LSNR). RESULTS: Both phantoms were used to evaluate the performance of a breast ultrasound scanner. The use of cylindrical phantoms led to an artificially higher image quality performance compared with the more clinically relevant spherical lesion phantom, thus indicating the importance of using the appropriate targets in ultrasound phantoms. CONCLUSION: The spherical lesion phantoms, coupled with the quantitative metric of LSNR, provides a comprehensive approach for performance and quality control testing, as well as the evaluation of advanced ultrasound imaging modes and technologies.


Assuntos
Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Ultrassonografia
5.
Eur J Neurosci ; 31(2): 349-58, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20074216

RESUMO

Neuregulin-1 (NRG1) has been shown to play a role in glutamatergic neurotransmission and is a risk gene for schizophrenia, in which there is evidence for hypoglutamatergic function. Sensitivity to the behavioural effects of the psychotomimetic N-methyl-D-aspartate receptor antagonists MK-801 and phencyclidine (PCP) was examined in mutant mice with heterozygous deletion of NRG1. Social behaviour (sociability, social novelty preference and dyadic interaction), together with exploratory activity, was assessed following acute or subchronic administration of MK-801 (0.1 and 0.2 mg/kg) or PCP (5 mg/kg). In untreated NRG1 mutants, levels of glutamate, N-acetylaspartate and GABA were determined using high-performance liquid chromatography and regional brain volumes were assessed using magnetic resonance imaging at 7T. NRG1 mutants, particularly males, displayed decreased responsivity to the locomotor-activating effects of acute PCP. Subchronic MK-801 and PCP disrupted sociability and social novelty preference in mutants and wildtypes and reversed the increase in both exploratory activity and social dominance-related behaviours observed in vehicle-treated mutants. No phenotypic differences were demonstrated in N-acetylaspartate, glutamate or GABA levels. The total ventricular and olfactory bulb volume was decreased in mutants. These data indicate a subtle role for NRG1 in modulating several schizophrenia-relevant processes including the effects of psychotomimetic N-methyl-D-aspartate receptor antagonists.


Assuntos
Comportamento Animal/efeitos dos fármacos , Neuregulina-1/metabolismo , Esquizofrenia/fisiopatologia , Comportamento Social , Animais , Ácido Aspártico/análogos & derivados , Ácido Aspártico/análise , Encéfalo/anatomia & histologia , Encéfalo/metabolismo , Maleato de Dizocilpina/farmacologia , Antagonistas de Aminoácidos Excitatórios/farmacologia , Feminino , Ácido Glutâmico/análise , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Neuregulina-1/genética , Fenciclidina/farmacologia , Fenótipo , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Fatores Sexuais , Ácido gama-Aminobutírico/análise
6.
Cardiovasc Eng Technol ; 9(3): 489-502, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29589332

RESUMO

Embolus Analogues (EAs) can provide understanding of the mechanical characteristics of blood clots of cardiac origin. Bovine EAs (n = 29) were fabricated with varying concentrations of thrombin (0-20 NIHU/ml blood). Histological staining confirmed that EA composition compared sufficiently with human samples reported in literature. EAs were mechanically described under seven testing conditions: tensile, compression, shear wave ultrasound elastography (SWE), parallel plate rheometry, indentation, creep and relaxation. The Young modulus of bovine EAs in tension varied from 7 kPa (5% strain) to 84 kPa (50% strain). The compressive Young modulus increased with increasing thrombin concentration, which was in agreement with the SWE results. There was no significant difference in Young modulus throughout the clot (p < 0.05). The EAs displayed a non-linear response under parallel plate rheometry, creep and stress relaxation. The 3rd order Mooney-Rivlin constitutive equation and Standard Linear Solid model were used to fit the non-linear stress-strain response and time-dependent properties, respectively. This is the first study in which bovine EAs, with and without addition of thrombin, are histologically and mechanically described with corresponding proposed constitutive equations. The equations and experimental data determined can be applied for future numerical and experimental testing of mammalian EAs and cardiac source clots.


Assuntos
Coagulação Sanguínea , Embolia/sangue , Animais , Fenômenos Biomecânicos , Bovinos , Força Compressiva , Modelos Animais de Doenças , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade , Embolia/diagnóstico por imagem , Embolia/fisiopatologia , Hemorreologia , Modelos Lineares , Modelos Cardiovasculares , Dinâmica não Linear , Resistência à Tração , Trombina/metabolismo , Fatores de Tempo
7.
Ir J Med Sci ; 185(4): 881-886, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26679189

RESUMO

BACKGROUND: Nystagmus in patients with multiple sclerosis (MS) is generally attributed to brainstem disease. Lesions in other regions may result in nystagmus. The identification of these other sites is enhanced by using 3-Tesla magnetic resonance imaging (3TMRI) due to increased signal-to-noise ratio. OBJECTIVE: We sought to evaluate the distribution of structural lesions and disruption of tracts in patients with horizontal nystagmus secondary to MS using 3TMRI. METHODS: Twenty-four patients (20 women, 4 men; age range 26-55 years) with horizontal nystagmus secondary to MS underwent 3TMRI brain scans; and 18 patients had diffusion tensor imaging (DTI) for tractography. RESULTS: Nystagmus was bidirectional in 11, right-sided in 6 and left-sided in 7. We identified 194 lesions in 20 regions within the neural integrator circuit in 24 patients; 140 were within the cortex and 54 were within the brainstem. Only two patients had no lesions in the cortex, and 9 had no lesions in the brainstem. There was no relationship between side of lesion and direction of nystagmus. Thirteen of 18 (72 %) had tract disruption with fractional anisotropy (FA) values below 0.2. FA was significantly lower in bidirectional compared to unidirectional nystagmus (p = 0.006). CONCLUSION: In MS patients with horizontal nystagmus, lesions in all cortical eye fields and their descending connections were evident. Technical improvements in tractography may help identify the specific site(s) resulting in nystagmus in MS.


Assuntos
Imagem de Tensor de Difusão/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Nistagmo Patológico/diagnóstico por imagem , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
Phys Med ; 30(3): 380-4, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24156827

RESUMO

Results from a four-year audit of a Doppler quality assurance (QA) program using a commercially available Doppler string phantom are presented. The suitability of the phantom was firstly determined and modifications were made to improve the reliability and quality of the measurements. QA of Doppler ultrasound equipment is very important as data obtained from these systems is used in patient management. It was found that if the braided-silk filament of the Doppler phantom was exchanged with an O-ring rubber filament and the velocity range below 50 cm/s was avoided for Doppler quality control (QC) measurements, then the maximum velocity accuracy (MVA) error and intrinsic spectral broadening (ISB) results obtained using this device had a repeatability of 18 ± 3.3% and 19 ± 3.5%, respectively. A consistent overestimation of the MVA of between 12% and 56% was found for each of the tested ultrasound systems. Of more concern was the variation of the overestimation within each respective transducer category: MVA errors of the linear, curvilinear and phased array probes were in the range 12.3-20.8%, 32.3-53.8% and 27-40.7%, respectively. There is a dearth of QA data for Doppler ultrasound; it would be beneficial if a multicentre longitudinal study was carried out using the same Doppler ultrasound test object to evaluate sensitivity to deterioration in performance measurements.


Assuntos
Hospitais , Auditoria Médica , Imagens de Fantasmas , Ultrassonografia Doppler/instrumentação , Controle de Qualidade
9.
Phys Med Biol ; 57(12): 3901-14, 2012 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-22643042

RESUMO

A new generation of ultrasound transient elastography (TE) systems have emerged which exploit the well-known correlation between the liver's pathological and mechanical properties through measurements of the Young's elastic modulus; however, little work has been carried out to examine the effect that fatty deposits may have on the TE measurement accuracy. An investigation was carried out on the effects on the measurement accuracy of a TE ultrasound system, the Fibroscan®, caused by overlaying fat layers of varying thickness on healthy liver-mimicking phantoms, simulating in vivo conditions for obese patients. Furthermore, a steatosis effect similar to that in non-alcoholic fatty liver disease (NAFLD) and alcoholic liver disease (ALD) was simulated to investigate its effect on the TE system. A range of novel elastography fat-mimicking materials were developed using 6-10 wt% poly(vinyl alcohol) cryogel capable of achieving a range of acoustic velocities (1482-1530 m s(-1)) and attenuation coefficients (0.4-1 dB MHz(-1) cm(-1)) for simulating different liver states. Laboratory-based acoustic velocities and attenuation coefficients were measured while the Young's modulus was established through a gold standard compression testing method. A significant variation of the Young's elastic modulus was measured in healthy phantoms with overlaying fat layers of thicknesses exceeding 45 mm, impinging on the scanners region of interest, overestimating the compression tested values by up to 11 kPa in some cases. Furthermore, Fibroscan® measurements of the steatosis phantoms showed a consistent overestimation (∼54%), which strongly suggests that the speed of sound mismatch between that of liver tissue and that assumed by the scanner is responsible for the high clinical cut-offs established in the case of ALD and NAFLD.


Assuntos
Tecido Adiposo , Técnicas de Imagem por Elasticidade/métodos , Fígado/diagnóstico por imagem , Acústica , Módulo de Elasticidade , Fígado Gorduroso/diagnóstico por imagem , Fígado/citologia , Fígado/patologia , Imagens de Fantasmas , Sensibilidade e Especificidade
10.
Phys Med Biol ; 55(19): 5965-83, 2010 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-20858913

RESUMO

The accuracy of a transient elastography liver-scanning ultrasound system was assessed using a novel application of PVA-cryogel as a tissue-mimicking material with acoustic and shear elasticity properties optimized to best represent those of liver tissue. Although the liver-scanning system has been shown to offer a safer alternative for diagnosing liver cirrhosis through stiffness measurement, as compared to the liver needle biopsy exam, the scanner's accuracy has not been fully established. Young's elastic modulus values of 5-6 wt% PVA-cryogel phantoms, also containing glycerol and 0.3 µm Al(2)O(3) and 3 µm Al(2)O(3), were measured using a 'gold standard' mechanical testing technique and transient elastography. The mechanically measured values and acoustic velocities of the phantoms ranged between 1.6 and 16.1 kPa and 1540 and 1570 m s(-1), respectively, mimicking those observed in liver tissue. The values reported by the transient elastography system overestimated Young's elastic modulus values representative of the progressive stages of liver fibrosis by up to 32%. These results were attributed to the relative rather than absolute nature of the measurement arising from the single-point acoustic velocity calibration of the system, rendering the measurements critically dependent on the speed of sound of the sample under investigation. Given the wide range of acoustic velocities which exist in the liver, spanning healthy tissue to cirrhotic pathology, coupled with the system's assumption that the liver is approximately elastic when it is rather highly viscoelastic, care should be exercised when interpreting the results from this system in patient groups.


Assuntos
Acústica , Técnicas de Imagem por Elasticidade/instrumentação , Hidrogéis , Fígado/diagnóstico por imagem , Fenômenos Mecânicos , Imagens de Fantasmas , Álcool de Polivinil/química , Criogéis , Humanos , Fígado/citologia , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA