1.
Rep Pract Oncol Radiother ; 28(6): 764-771, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38515814

RESUMO

Background: The aim of this study was to determine if rotational uncertainties in gynecological cancer patients can be reduced using surface imaging (SI) compared to aligning three markers on the patient's skin with in-room lasers (marker-laser). Materials and methods: Fifty gynecological cancer patients treated with external-beam radiotherapy were retrospectively analyzed; 25 patients were positioned with marker-laser and 25 patients were positioned with SI. The values of rotational (pitch and roll) deviations of the patient positions between the treatment-planning computed tomography (CT) and online cone-beam computed tomography (CBCT) were collected for both subcohorts and all treatment fractions after performing automatic registration between the two image sets. Statistical analysis of the difference between the two set-up methods was performed using the Mann-Whitney U-test. Results: The median pitch deviation were 1.5° [interquartile range (IQR): 0.6°-2.6°] and 1.1° (IQR: 0.5°-1.9°) for the marker-laser and SI methods, respectively (p < 0.01). The median roll deviation was 0.5° (IQR: 0.2°-0.9°), and 0.7° (IQR: 0.3°-1.2°) for the marker-laser and SI methods, respectively (p < 0.01). Given the shape of the target, pitch deviations had a greater impact on the uncertainty at the periphery of the target and were considered more relevant. Conclusion: By introducing SI as a set-up method in gynecological cancer patients, higher positioning accuracy could be achieved compared with the marker-laser set-up method. This was demonstrated based on residual deviations rather than deviations corrected for by image-guided radiotherapy (IGRT).

2.
Med Phys ; 39(3): 1588-94, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22380391

RESUMO

PURPOSE: Real-time dynamic multileaf collimator (MLC) tracking for management of intrafraction tumor motion can be challenging for highly modulated beams, as the leaves need to travel far to adjust for target motion perpendicular to the leaf travel direction. The plan modulation can be reduced by using a leaf position constraint (LPC) that reduces the difference in the position of adjacent MLC leaves in the plan. The purpose of this study was to investigate the impact of the LPC on the quality of inversely optimized arc radiotherapy plans and the effect of the MLC motion pattern on the dosimetric accuracy of MLC tracking delivery. Specifically, the possibility of predicting the accuracy of MLC tracking delivery based on the plan modulation was investigated. METHODS: Inversely optimized arc radiotherapy plans were created on CT-data of three lung cancer patients. For each case, five plans with a single 358° arc were generated with LPC priorities of 0 (no LPC), 0.25, 0.5, 0.75, and 1 (highest possible LPC), respectively. All the plans had a prescribed dose of 2 Gy × 30, used 6 MV, a maximum dose rate of 600 MU/min and a collimator angle of 45° or 315°. To quantify the plan modulation, an average adjacent leaf distance (ALD) was calculated by averaging the mean adjacent leaf distance for each control point. The linear relationship between the plan quality [i.e., the calculated dose distributions and the number of monitor units (MU)] and the LPC was investigated, and the linear regression coefficient as well as a two tailed confidence level of 95% was used in the evaluation. The effect of the plan modulation on the performance of MLC tracking was tested by delivering the plans to a cylindrical diode array phantom moving with sinusoidal motion in the superior-inferior direction with a peak-to-peak displacement of 2 cm and a cycle time of 6 s. The delivery was adjusted to the target motion using MLC tracking, guided in real-time by an infrared optical system. The dosimetric results were evaluated using gamma index evaluation with static target measurements as reference. RESULTS: The plan quality parameters did not depend significantly on the LPC (p ≥ 0.066), whereas the ALD depended significantly on the LPC (p < 0.001). The gamma index failure rate depended significantly on the ALD, weighted to the percentage of the beam delivered in each control point of the plan (ALD(w)) when MLC tracking was used (p < 0.001), but not for delivery without MLC tracking (p ≥ 0.342). The gamma index failure rate with the criteria of 2% and 2 mm was decreased from > 33.9% without MLC tracking to <31.4% (LPC 0) and <2.2% (LPC 1) with MLC tracking. CONCLUSIONS: The results indicate that the dosimetric robustness of MLC tracking delivery of an inversely optimized arc radiotherapy plan can be improved by incorporating leaf position constraints in the objective function without otherwise affecting the plan quality. The dosimetric robustness may be estimated prior to delivery by evaluating the ALD(w) of the plan.


Assuntos
Radioterapia Assistida por Computador/métodos , Movimento , Imagens de Fantasmas , Radiometria , Fatores de Tempo
3.
Med Phys ; 47(10): 5274-5286, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32737870

RESUMO

PURPOSE: Particle therapy is becoming increasingly available world-wide for precise tumor targeting, its favorable depth dose deposition, and increased biological damage to tumor tissue compared to conventional photon therapy. As demand increases for improved robustness and conformality, next-generation secondary dose calculation engines are needed to verify treatment plans independently and provide estimates for clinical decision-making factors, such as dose-averaged linear energy transfer (LETd ) and relative biological effectiveness (RBE). METHOD: FRoG (Fast dose Recalculation on GPU) has been installed and commissioned at the Danish Centre for Particle Therapy (DCPT). FRoG was developed for synchrotron-based facilities and has previously demonstrated good agreement with gold-standard Monte Carlo simulations and measurements. In this work, additions and modifications to FRoG's pencil beam algorithm to support the ion beam delivery with cyclotron-based technology as used at the DCPT, range shifter (RS) implementation, and robustness analysis methods are presented. FRoG dose predictions are compared to measurements and predictions of the clinical treatment planning system (TPS) Eclipse (Varian Medical Systems, Palo Alto, United States of America, CA, v.13.7.16) in both homogenous and heterogeneous scenarios using a solid-water/water and a half-head anthropomorphic phantom, respectively. Additional capabilities of FRoG are explored by performing a plan robustness analysis, analyzing dose and LETd for ten patients. RESULTS: Mid-target measurements in spread-out Bragg Peaks (SOBP) were on average within -0.19% ± 0.30% and ≤0.5% of FRoG predictions for irradiations without and with RS, respectively. Average 3%/2mm 3D γ-analysis passing rates were 99.1% for ~200 patient plan QA comparisons. Measurement with an anthropomorphic head-phantom yielded a γ-passing rate >98%. Overall, maximum target differences in D02% of <2% between the TPS and FRoG were observed for patient plans. The robustness analysis study accounting for range, delivery, and positioning uncertainties revealed small differences in target dose and a maximum LETd VH02% (LETd received by 2% of the volume having dose larger than 1% of maximum dose) values below 10.1 keV/µm to the brain stem. CONCLUSION: We demonstrate that auxiliary dose calculation systems like FRoG can yield excellent agreement to measurements comparable to clinical beam models. Through this work, application of FRoG as a secondary engine at third party cyclotron-based particle treatment facilities is now established for dose verification as well as providing further insight on LETd and variable RBE distributions for protons, currently absent from the standard clinical TPS.


Assuntos
Terapia com Prótons , Algoritmos , Humanos , Transferência Linear de Energia , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica Relativa
4.
Med Phys ; 41(10): 101707, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281946

RESUMO

PURPOSE: To compare real-time dynamic multileaf collimator (MLC) tracking, respiratory amplitude and phase gating, and no compensation for intrafraction motion management during intensity modulated arc therapy (IMAT). METHODS: Motion management with MLC tracking and gating was evaluated for four lung cancer patients. The IMAT plans were delivered to a dosimetric phantom mounted onto a 3D motion phantom performing patient-specific lung tumor motion. The MLC tracking system was guided by an optical system that used stereoscopic infrared (IR) cameras and five spherical reflecting markers attached to the dosimetric phantom. The gated delivery used a duty cycle of 35% and collected position data using an IR camera and two reflecting markers attached to a marker block. RESULTS: The average gamma index failure rate (2% and 2 mm criteria) was <0.01% with amplitude gating for all patients, and <0.1% with phase gating and <3.7% with MLC tracking for three of the four patients. One of the patients had an average failure rate of 15.1% with phase gating and 18.3% with MLC tracking. With no motion compensation, the average gamma index failure rate ranged from 7.1% to 46.9% for the different patients. Evaluation of the dosimetric error contributions showed that the gated delivery mainly had errors in target localization, while MLC tracking also had contributions from MLC leaf fitting and leaf adjustment. The average treatment time was about three times longer with gating compared to delivery with MLC tracking (that did not prolong the treatment time) or no motion compensation. For two of the patients, the different motion compensation techniques allowed for approximately the same margin reduction but for two of the patients, gating enabled a larger reduction of the margins than MLC tracking. CONCLUSIONS: Both gating and MLC tracking reduced the effects of the target movements, although the gated delivery showed a better dosimetric accuracy and enabled a larger reduction of the margins in some cases. MLC tracking did not prolong the treatment time compared to delivery with no motion compensation while gating had a considerably longer delivery time. In a clinical setting, the optical monitoring of the patients breathing would have to be correlated to the internal movements of the tumor.


Assuntos
Neoplasias Pulmonares/radioterapia , Movimento (Física) , Radioterapia de Intensidade Modulada/métodos , Fluoroscopia , Humanos , Raios Infravermelhos , Imagens de Fantasmas , Radiometria , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Respiração , Fatores de Tempo
5.
Phys Med Biol ; 58(7): 2349-61, 2013 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-23492899

RESUMO

This study investigated the dosimetric impact of uncompensated motion and motion compensation with dynamic multileaf collimator (DMLC) tracking for prostate intensity modulated arc therapy. Two treatment approaches were investigated; a conventional approach with a uniform radiation dose to the target volume and an intraprostatic lesion (IPL) boosted approach with an increased dose to a subvolume of the prostate. The impact on plan quality of optimizations with a leaf position constraint, which limited the distance between neighbouring adjacent MLC leaves, was also investigated. Deliveries were done with and without DMLC tracking on a linear acceleration with a high-resolution MLC. A cylindrical phantom containing two orthogonal diode arrays was used for dosimetry. A motion platform reproduced six patient-derived prostate motion traces, with the average displacement ranging from 1.0 to 8.9 mm during the first 75 s. A research DMLC tracking system was used for real-time motion compensation with optical monitoring for position input. The gamma index was used for evaluation, with measurements with a static phantom or the planned dose as reference, using 2% and 2 mm gamma criteria. The average pass rate with DMLC tracking was 99.9% (range 98.7-100%, measurement as reference), whereas the pass rate for untracked deliveries decreased distinctly as the average displacement increased, with an average pass rate of 61.3% (range 32.7-99.3%). Dose-volume histograms showed that DMLC tracking maintained the planned dose distributions in the presence of motion whereas traces with >3 mm average displacement caused clear plan degradation for untracked deliveries. The dose to the rectum and bladder had an evident dependence on the motion direction and amplitude for untracked deliveries, and the dose to the rectum was slightly increased for IPL boosted plans compared to conventional plans for anterior motion with large amplitude. In conclusion, optimization using a leaf position constraint had minimal dosimetric effect, DMLC tracking improved the target and normal tissue dose distributions compared to no tracking for target motion >3 mm, with the DMLC tracking distributions showing generally good agreement between the planned and delivered doses.


Assuntos
Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada/métodos , Humanos , Masculino , Tamanho do Órgão , Radiometria , Planejamento da Radioterapia Assistida por Computador
6.
Med Phys ; 40(11): 111717, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24320425

RESUMO

PURPOSE: Intensity modulated arc therapy (IMAT) is commonly used to treat prostate cancer. The purpose of this study was to evaluate the impact of leaf width and plan complexity on dynamic multileaf collimator (DMLC) tracking for prostate motion management during IMAT treatments. METHODS: Prostate IMAT plans were delivered with either a high-definition MLC (HDMLC) or a Millennium MLC (M-MLC) (0.25 and 0.50 cm central leaf width, respectively), with and without DMLC tracking, to a dosimetric phantom that reproduced four prostate motion traces. The plan complexity was varied by applying leaf position constraints during plan optimization. A subset of the M-MLC plans was converted for delivery with the HDMLC, isolating the effect of the different leaf widths. The gamma index was used for evaluation. Tracking errors caused by target localization, leaf fitting, and leaf adjustment were analyzed. RESULTS: The gamma pass rate was significantly improved with DMLC tracking compared to no tracking (p < 0.001). With DMLC tracking, the average gamma index pass rate was 98.6% (range 94.8%-100%) with the HDMLC and 98.1% (range 95.4%-99.7%) with the M-MLC, using 3%, 3 mm criteria and the planned dose as reference. The corresponding pass rates without tracking were 87.6% (range 76.2%-94.7%) and 91.1% (range 81.4%-97.6%), respectively. Decreased plan complexity improved the pass rate when static target measurements were used as reference, but not with the planned dose as reference. The main cause of tracking errors was leaf fitting errors, which were decreased by 42% by halving the leaf width. CONCLUSIONS: DMLC tracking successfully compensated for the prostate motion. The finer leaf width of the HDMLC improved the tracking accuracy compared to the M-MLC. The tracking improvement with limited plan complexity was small and not discernible when using the planned dose as reference.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Radioterapia de Intensidade Modulada/métodos , Desenho de Equipamento , Raios gama , Humanos , Imageamento Tridimensional , Masculino , Movimento , Aceleradores de Partículas , Imagens de Fantasmas , Próstata/patologia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Software
7.
Radiother Oncol ; 94(2): 218-23, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20089322

RESUMO

BACKGROUND AND PURPOSE: Motion compensation with MLC tracking was tested for inversely optimized arc radiotherapy with special attention to the impact of the size of the target displacements and the angle of the leaf trajectory. MATERIALS AND METHODS: An MLC-tracking algorithm was used to adjust the MLC positions according to the target movements using information from an optical real-time positioning management system. Two plans with collimator angles of 45 degrees and 90 degrees , respectively, were delivered and measured using the Delta(4)(R) dosimetric device moving in the superior-inferior direction with peak-to-peak displacements of 5, 10, 15, 20 and 25 mm and a cycle time of 6s. RESULTS: Gamma index evaluation for plan delivery with MLC tracking gave a pass rate higher than 98% for criteria 3% and 3 mm for both plans and for all sizes of the target displacement. With no motion compensation, the average pass rate was 75% for plan 1 and 70% for plan 2 for 25 mm peak-to-peak displacement. CONCLUSION: MLC tracking improves the accuracy of inversely optimized arc delivery for the cases studied. With MLC tracking, the dosimetric accuracy was independent of the magnitude of the peak-to-peak displacement of the target and not significantly affected by the angle between the leaf trajectory and the target movements.


Assuntos
Neoplasias Pulmonares/radioterapia , Radioterapia de Intensidade Modulada/instrumentação , Algoritmos , Simulação por Computador , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Aceleradores de Partículas , Posicionamento do Paciente , Imagens de Fantasmas , Radiometria/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Software , Fatores de Tempo , Tomografia Computadorizada por Raios X