Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 36(6): 2100-2104, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33573813

RESUMO

BACKGROUND: Total hip arthroplasty with ceramic-on-ceramic articulation aims to decrease wear, osteolysis, and aseptic loosening. A metal-backed ceramic liner was developed to reduce the risk of liner fracture. However, a significant number of cases of mal-seating of the metal-backed ceramic liner were observed in the 2000s, and there were concerns about their outcome. This review aims to investigate the long-term performance of the mal-seated ceramic liner. METHODS: From July 2003 to March 2007, 35 ceramic-on-ceramic total hip arthroplasties were performed with the Trident acetabular system. Clinical assessment, radiological analysis, and outcome assessment were performed. The prevalence of liner mal-seating and its long-term outcomes were investigated. RESULTS: There was liner mal-seating in 8 hips (22.9%). One liner was exchanged in the early postoperative period. No revision surgery was required for the remaining 7 hips at a mean follow-up of 14 years. All patients were free of hip pain with a mean Harris Hip Score of 94.7 at the most recent follow-up. No adverse event was observed. CONCLUSION: The long-term outcomes of the mal-seated liner were favorable. However, surgeons should exercise meticulous surgical technique to achieve a properly aligned liner within the acetabular shell to minimize this potentially correctable error.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Cerâmica , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação , Resultado do Tratamento
2.
J Arthroplasty ; 26(2): 338.e9-11, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20116971

RESUMO

We reported a rare mode of extensor mechanism failure in total knee arthroplasty. The patellar tendon was elongated and thin instead of disruption at the bone-tendon junction. We also described the surgical technique for reconstruction of patellar tendon. Patellar tendon was shortened by a precalculated amount. It was then augmented by autologous semitendinosus tendon graft and protected by tension band wire. Active full knee extension could be achieved at postoperative 10 months after the removal of wire loop.


Assuntos
Artroplastia do Joelho/efeitos adversos , Doenças Musculares/etiologia , Ligamento Patelar , Idoso , Humanos , Masculino , Doenças Musculares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA