Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Surg Technol Int ; 40: 149-153, 2022 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-35158403

RESUMO

Ventral hernia repair (VHR) fixation techniques with current meshes on the market are prone to failure from intra-abdominal pressure spikes due to coughing or lifting, for example. The T-Line® Hernia Mesh (Deep Blue Medical Advances, Durham, North Carolina) is a new mesh with a novel fixation mechanism to enhance anchoring strength addressing hernia occurrence and recurrence. Used similarly to traditional mesh, the new mesh uses incorporated mesh sutures that are 15 times the surface area of sutures for fixation rather than monofilament sutures, providing ~275% stronger anchoring strength. The increased surface area of the mesh extensions decreases tension on the mesh and tissue and increases the strength of the repair overall. There is also the likelihood that anchoring gains strength over time as the extensions undergo bioincorporation. This novel mesh specifically addresses the most common complication of VHR and has the potential to significantly improve outcomes.


Assuntos
Hérnia Ventral , Telas Cirúrgicas , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Humanos , Próteses e Implantes , Recidiva , Suturas
2.
Surg Technol Int ; 38: 213-217, 2021 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-34000755

RESUMO

PURPOSE: Hernia prevention following abdominal surgery has become a subject of growing interest in general surgery. Prophylactic mesh augmentation (PMA) is an emerging technique to prevent incisional hernia in high-risk populations. The aim of this study was to determine the efficacy and safety of PMA using an absorbable mesh. METHODS: A retrospective review was performed on patients who underwent PMA between July 2014 and March 2020. A prophylactic synthetic absorbable mesh (Phasix™; Becton Dickinson, Franklin Lakes, NJ) was placed at the surgeon's discretion according to the indication for the primary operation. The primary outcome was the incisional hernia rate. Secondary outcomes included mesh-related or other complications. RESULTS: Fifty patients underwent PMA following cystectomy with ileal conduit, open aortic surgery, or colostomy creation/takedown. Overall, 10 patients (20%) developed hernia at a median follow-up of 2.2 years. Six of these 10 hernias occurred at incisions where mesh was not placed. There were no documented mesh infections. One mesh (2%) in the AAA group was explanted due to an infected endograft, but there was no evidence of mesh complication. Two patients (4%) developed seroma. Two (4%) patients developed superficial surgical site infections (SSI). There were no documented deep-space SSI. CONCLUSION: PMA is an emerging technique with a low rate of incisional hernia in high-risk patients, such as those undergoing stoma creation or open aortic intervention. The use of an absorbable mesh seems promising, however more and longer-term research is needed.


Assuntos
Hérnia Ventral , Hérnia Incisional , Estomas Cirúrgicos , Derivação Urinária , Hérnia Ventral/epidemiologia , Hérnia Ventral/cirurgia , Humanos , Hérnia Incisional/epidemiologia , Hérnia Incisional/prevenção & controle , Estudos Retrospectivos , Telas Cirúrgicas
3.
Surg Technol Int ; 37: 121-125, 2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33091953

RESUMO

INTRODUCTION: As studies continue to provide advanced knowledge concerning abdominal wall closure after laparotomy, there have been many improvements in surgical techniques and recommended closure materials. However, there continues to be a high rate of incisional hernias following exploratory laparotomies. The goal of this review is to provide a comprehensive assessment of available educational models for laparotomy closure. MATERIAL AND METHODS: A comprehensive literature review was made using PubMed, Cochrane, and NCBI MeSH databases to find the most relevant articles associated with various abdominal closure models using specific keywords. RESULTS: Human cadaver, animal, synthetic, and virtual reality models were reviewed. Strengths and limitations of each model were described. CONCLUSION: Each model has practical benefits in its ability to mimic in vitro anatomy and the experiential similarities to actual laparotomy closure. However, there are also limitations and potential cost-prohibitive factors for individual models. Overall, while there have been some advances in synthetic and virtual models, human cadaver and porcine models remain the most similar to human abdominal wall closures.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Incisional , Animais , Humanos , Laparotomia , Modelos Educacionais , Telas Cirúrgicas , Técnicas de Sutura , Suínos
4.
Surg Technol Int ; 35: 129-134, 2019 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-31687785

RESUMO

Abdominal wall tension is an integral concept in hernia repair. Most of the described techniques attempt to reduce abdominal wall tension by using mesh prosthetics or myofascial release. Although the concept of a "tension-free" hernia repair is well-understood and appreciated by surgeons, quantitative information about abdominal wall tension is limited. This review evaluates the published literature related to abdominal wall tension and summarizes how the measurement of intraoperative tension can guide clinical decision-making. Most of the methods and techniques for measuring abdominal wall tension are similar and involve the use of tensiometers. However, there is no accepted standardized technique. Baseline tension measurements confirm the concept of a baseline physiological tension, and it has been observed that tension does not correlate with hernia width. When the tension is considered to be too great during hernia repair, intraoperative techniques such as myofascial release can be used to reduce tension to physiological values. Emerging data from clinical studies on tension have added to our understanding of the mechanics and physiology of the abdominal wall. Standardized devices and measurement techniques need to be developed and validated to foster the utility of tension measurements in hernia repair.


Assuntos
Parede Abdominal , Hérnia Abdominal , Hérnia Ventral , Herniorrafia , Parede Abdominal/cirurgia , Hérnia Abdominal/cirurgia , Hérnia Ventral/cirurgia , Humanos , Próteses e Implantes , Telas Cirúrgicas
5.
Am Surg ; 89(9): 3820-3821, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37243531

RESUMO

Abdominal aortic aneurysm (AAA) is a common medical condition with the feared, and often fatal, complication of rupture. The risk of rupture has been well documented to correlate with aneurysm size. It is exceedingly rare for an AAA less than 5 cm to rupture. This case report demonstrates an asymptomatic 4.3 cm AAA that ruptured while admitted to the hospital with COVID-19 pneumonia. The patient was successfully managed with an endovascular aortoiliac stent graft. Although rare, in patients with small AAA, rupture must remain in the differential diagnosis in the setting of acute onset abdominal or back pain. Furthermore, when quickly recognized, these patients can be safely managed with an endovascular approach.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Stents/efeitos adversos , Aorta , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Fatores de Risco
6.
Am Surg ; 89(8): 3449-3453, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36935586

RESUMO

Despite evidence that small bite closure is beneficial, it is not well documented how accurately and consistently surgeons employ this technique. We created a felt model to simulate fascial closure and educate residents regarding small bites. This study aims to gauge accuracy and consistency of bite size in fascial closure and assess if utilizing a templated model could improve technique. Two 10 cm incisions were made in different pieces of felt. Residents were instructed to suture the incisions to simulate fascial closure by running the incisions closed with 1 cm and 5 mm bites respectively. The process was repeated with templated pieces of felt marking 1 and 0.5 cm to guide bite size. Residents were timed for each closure. The travel and distance from the midline for each bite was measured and analysis performed. 14 residents participated. Paired T-test compared means and standard deviations of bite size. Taking 5 mm bites took more time. Standard deviation of travel and right sided distance from midline were significantly smaller when a template was utilized. Standard deviation of travel as well as right sided distance was also improved when instructed to take 5 mm bites. This study demonstrates that a small bite technique results more closure and that when residents are instructed to take smaller bites. The adage, "aim small, miss small," holds true in fascial closure and may be one reason why small bites improve hernia rates. This study also suggests that the use of a template improves accuracy and consistency of closure regardless of bite size intention.


Assuntos
Técnicas de Fechamento de Ferimentos Abdominais , Hérnia Incisional , Humanos , Técnicas de Sutura , Laparotomia/métodos , Fáscia
7.
Am Surg ; 89(9): 3968-3970, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37431298

RESUMO

The Gaboon viper (Bitis gabonica) is an exotic snake native to sub-Saharan Africa. Gaboon viper venom is an extremely toxic hemotoxin, causing severe coagulopathy and local tissue necrosis. These are not aggressive snakes and therefore bites involving humans are rare and there is not a substantial amount of literature documenting how to manage these injuries and resultant coagulopathies. We report a 29-year-old male presenting 3 hours after a Gaboon viper envenomation resulting in coagulopathy requiring massive resuscitation and multiple doses of antivenom. The patient received various blood products based on thromboelastography (TEG) and also underwent early continuous renal replacement therapy (CRRT) to assist in correction of severe acidosis and acute renal failure. The combination of TEG to guide resuscitation, administration of antivenom, and early implementation of CRRT allowed our team to correct venom-induced consumptive coagulopathy and ultimately allow the patient to survive following this extremely deadly Gaboon viper envenomation.


Assuntos
Transtornos da Coagulação Sanguínea , Mordeduras de Serpentes , Masculino , Animais , Humanos , Adulto , Antivenenos/uso terapêutico , Bitis , Mordeduras de Serpentes/complicações , Mordeduras de Serpentes/terapia , Tromboelastografia , Venenos de Víboras/uso terapêutico , Venenos de Víboras/toxicidade , Transtornos da Coagulação Sanguínea/terapia , Transtornos da Coagulação Sanguínea/complicações
8.
Am Surg ; 88(5): 1026-1027, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35282710

RESUMO

Social media platforms are becoming more ubiquitous in surgery with a mission to bring surgeons closer together through education and learning. The purpose of this project is to evaluate the social media posts relating to referral of patients through one of the online social media platforms. The International Hernia Collaboration closed Facebook site was queried with terms relating to referrals and descriptive statistics generated. There were a total of 36 posts relating to surgical referrals between October 2014 and January 2021. Posts were from 32 different surgeons and included 30 different locations throughout the United States. An online social media platform is a viable way to refer patients throughout the United States and abroad. Further study is needed to evaluate the role of social media for surgical referrals and its impact on patient care.


Assuntos
Mídias Sociais , Cirurgiões , Hérnia , Humanos , Encaminhamento e Consulta , Cirurgiões/educação , Estados Unidos
9.
J Laparoendosc Adv Surg Tech A ; 31(7): 779-782, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33147082

RESUMO

Background and Objectives: There are weak data comparing the safety and efficacy of absorbable and permanent tacks in laparoscopic ventral hernia repair with tack-only mesh fixation. In this study, we compared recurrence and complications rates following hernia repair using either only absorbable or only permanent tacks. Methods: Data from the Americas Hernia Society Quality Collaborative database were retrospectively reviewed as accessed on June 30, 2017. The query included patients 18 years of age or older, who had undergone laparoscopic ventral hernia repair with mesh using tack-only fixation. Study groups were divided into patients who had only absorbable tacks used and those with only permanent tacks. Propensity score matching was applied to strengthen the groups. Results: There were no significant differences in demographics, comorbidities, or hernia characteristics between the groups. There were no significant differences in length of stay, hernia recurrence rate, or surgical site infection. The permanent tack group had a significantly higher rate of surgical site occurrences (SSOs), as evidenced by a higher rate of seroma formation. Conclusion: When comparing the rates of complications and recurrences between absorbable and permanent tacks in the setting of laparoscopic ventral hernia repair with tack-only mesh fixation, the only significant difference found was that the permanent group had a higher rate of SSO due to seroma formation. Because this complication did not lead to an increased intervention rate, the clinical significance of this finding remains in question.


Assuntos
Hérnia Ventral/cirurgia , Herniorrafia/métodos , Laparoscopia/métodos , Complicações Pós-Operatórias/etiologia , Suturas/efeitos adversos , Adolescente , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Recidiva , Estudos Retrospectivos , Seroma/epidemiologia , Seroma/etiologia , Telas Cirúrgicas , Técnicas de Sutura , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA