Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
1.
J Dairy Sci ; 107(5): 3104-3113, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38135051

RESUMO

Age at first calving (AFC) represents the nonproductive period of ∼2 yr in Holstein cows, and thus, it has a relevant effect on the cost of rearing replacements in the dairy herd. In the present study, we aimed to evaluate genetic and genomic aspects of AFC in the Italian Holstein population. Data of 4,206,218 heifers with first calving between 1996 and 2020 were used. Age at first calving averaged 26.09 ± 3.07 mo and decreased across years. Heritability was estimated using a linear animal model which included the fixed effects of herd-year-season of birth and classes of gestation length, and the random animal additive genetic effect fitted to a pedigree-based relationship matrix. The EBV and genomically EBV (GEBV) were obtained, and they were standardized to mean 100 and standard deviation 5, where animals above the mean are those contributing to reduce AFC. Heritability estimates of AFC ranged from 0.031 to 0.045. The trend of sires' GEBV was favorable and indicated a reduced AFC across years. Approximate genetic correlations between GEBV of AFC and GEBV of other economically important traits were calculated on a subset of genotyped females born after 2015. Moderate favorable associations of AFC with production traits (0.39-0.51), udder depth (0.40), interval from first to last insemination in heifer (-0.43), and longevity (0.34) were assessed. Overall, the greatest lifetime productive performances and most favorable days open in first lactation were observed when heifers calved at 22 to 23 mo. In contrast, progeny of sires with GEBV of AFC above the mean yielded more milk, fat, and protein in first lactation, and had shorter days open than progeny of sires with GEBV of AFC below the mean. Results suggested that breeding strategies to improve AFC should be pursued, also considering genetic correlations between AFC and traits which are already part of the Italian Holstein breeding objective. The inclusion of AFC in an aggregate index is expected to contribute to enhance farm income.


Assuntos
Lactação , Leite , Bovinos/genética , Animais , Feminino , Lactação/genética , Leite/metabolismo , Longevidade , Genômica , Itália
2.
Cancer Immunol Immunother ; 69(12): 2513-2522, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32561968

RESUMO

BACKGROUND: An elevated pre-treatment neutrophil to lymphocytes ratio (NLR) is associated with poor prognosis in various malignancies. Optimal cut-off is highly variable across studies and could not be determined individually for a patient to inform his prognosis. We hypothesize that NLR variations could be more useful than baseline NLR to predict progression-free survival (PFS) and overall survival (OS) in patients (pts) receiving anti-PD1 treatment. PATIENTS AND METHODS: All pts with metastatic renal cell carcinoma (mRCC) and metastatic non-small cell lung cancer (mNSCLC) who received anti-PD1 nivolumab monotherapy in second-line setting or later were included in this French multicentric retrospective study. NLR values were prospectively collected prior to each nivolumab administration. Clinical characteristics were recorded. Associations between baseline NLR, NLR variations and survival outcomes were determined using Kaplan-Meier's method and multivariable Cox regression models. RESULTS: 161 pts (86 mRCC and 75 mNSCLC) were included with a median follow-up of 18 months. On the whole cohort, any NLR increase at week 6 was significantly associated with worse outcomes compared to NLR decrease, with a median PFS of 11 months vs 3.7 months (p < 0.0001), and a median OS of 28.5 months vs. 18 months (p = 0.013), respectively. In multivariate analysis, NLR increase was significantly associated with worse PFS (HR 2.2; p = 6.10-5) and OS (HR 2.1; p = 0.005). Consistent results were observed in each cohort when analyzed separately. CONCLUSION: Any NLR increase at week 6 was associated with worse PFS and OS outcomes. NLR variation is an inexpensive and dynamic marker easily obtained to monitor anti-PD1 efficacy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma de Células Renais/tratamento farmacológico , Neoplasias Renais/tratamento farmacológico , Neoplasias Pulmonares/tratamento farmacológico , Linfócitos/imunologia , Neutrófilos/imunologia , Nivolumabe/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/sangue , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma de Células Renais/imunologia , Carcinoma de Células Renais/mortalidade , Carcinoma de Células Renais/secundário , Estudos de Viabilidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Renais/imunologia , Neoplasias Renais/mortalidade , Neoplasias Renais/patologia , Contagem de Leucócitos , Neoplasias Pulmonares/sangue , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/mortalidade , Masculino , Pessoa de Meia-Idade , Prognóstico , Intervalo Livre de Progressão , Estudos Prospectivos , Estudos Retrospectivos , Medição de Risco/métodos , Adulto Jovem
3.
ScientificWorldJournal ; 2020: 4576748, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32372885

RESUMO

In clinical daily practice, there are situations in which implant sites have vertical and/or horizontal bone defects and often we must improve their morphology and dimensions before fixture insertion. It is crucial to carefully evaluate the surgical site as regards the characteristics of both hard and soft tissues. The orthodontic extrusion technique can be used for nonsurgical augmentation of the implant site as an alternative to traditional regenerative/reparative surgical therapies. The orthodontic extrusion is based on a biological mechanism that uses the portion of periodontal ligament, still present on the root before the tooth extraction, for the increase of hard and soft tissues. In the literature, there is no evidence of common guidelines for this technique but only tips based on personal experience and/or previous studies. The aim of this study was to investigate and to validate the reliability of a new orthodontic extrusion technique (MF Extrusion Technique, by Dr. Mauro Fadda) by means of a retrospective consecutive case-series study. After we have done a review of the literature, we evaluated the X-rays of twelve consecutively treated patients before the orthodontic extrusion (T0) and after the stabilization period (T1), in order to quantify, by two different measurements, area and linear, the bone gain obtained by the application of the new technique. All the patients examined showed a significant increase in bone areas with an average value of 31.575 mm2. The linear bone gain had an average value of 4.63 mm. Data collected were statistically analysed by the Wilcoxon signed-rank test. The results obtained both from area and linear measurements at T0 and at T1 times showed that there was a statistically significant bone gain with p < 0.01.

5.
J Neurosci ; 34(22): 7663-76, 2014 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-24872570

RESUMO

Schizophrenia is associated with upregulation of dopamine (DA) release in the caudate nucleus. The caudate has dense connections with the orbitofrontal cortex (OFC) via the frontostriatal loops, and both areas exhibit pathophysiological change in schizophrenia. Despite evidence that abnormalities in dopaminergic neurotransmission and prefrontal cortex function co-occur in schizophrenia, the influence of OFC DA on caudate DA and reinforcement processing is poorly understood. To test the hypothesis that OFC dopaminergic dysfunction disrupts caudate dopamine function, we selectively depleted dopamine from the OFC of marmoset monkeys and measured striatal extracellular dopamine levels (using microdialysis) and dopamine D2/D3 receptor binding (using positron emission tomography), while modeling reinforcement-related behavior in a discrimination learning paradigm. OFC dopamine depletion caused an increase in tonic dopamine levels in the caudate nucleus and a corresponding reduction in D2/D3 receptor binding. Computational modeling of behavior showed that the lesion increased response exploration, reducing the tendency to persist with a recently chosen response side. This effect is akin to increased response switching previously seen in schizophrenia and was correlated with striatal but not OFC D2/D3 receptor binding. These results demonstrate that OFC dopamine depletion is sufficient to induce striatal hyperdopaminergia and changes in reinforcement learning relevant to schizophrenia.


Assuntos
Núcleo Caudado/metabolismo , Dopamina/deficiência , Lobo Frontal/metabolismo , Aprendizagem/fisiologia , Reforço Psicológico , Regulação para Cima/genética , Animais , Callithrix , Núcleo Caudado/fisiopatologia , Dopamina/biossíntese , Dopamina/genética , Feminino , Masculino , Regulação para Cima/fisiologia
6.
Eur J Vasc Endovasc Surg ; 47(1): 53-60, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24183249

RESUMO

OBJECTIVES: The purpose of this in vitro study was to clinically assess the feasibility of a three-dimensional (3D) electromagnetic (EM) navigator, including sensorized catheters and guidewires, to determine any reduction in radiation dose and contrast medium injection. METHODS: The study was performed using a navigator prototype developed at the EndoCAS center. The system includes catheters and guidewires simultaneously tracked with an EM localizer (Aurora, Northern Digital, Waterloo, Canada). Tests were performed on a commercial abdominal aortic aneurysm model. Fifteen operators were asked to cannulate renal arteries using the conventional fluoroscopic guidance and the EM navigator without fluoroscopic support. Each trial was video-recorded and analyzed for timing and success of completing the cannulation task by two blinded and independent observers. Performances were also qualitatively evaluated using the Imperial College Endovascular Cannulation Scoring Tool (IC3ST). Moreover, a questionnaire was administered to participants to evaluate the navigator potentialities. RESULTS: Quantitative analysis results show no significant difference between the fluoroscopic and EM guidance regarding the total procedure time (median 2.36 minutes [interquartile range {IQR} = 1.26-4.7) vs. 2.95 min [IQR = 1.35-5.38], respectively; p = .93); number of total hits with catheter/guidewire tip to vessels wall (median 5.50 [IQR = 2.00-10.00] vs. 3.50 [IQR = 2.50-7.00], respectively; p = .65); and number of attempts at cannulation (median 4.0 [IQR = 2.00-5.00] vs. 4.0 [IQR = 2.00-5.00], respectively; p = .72]. Moreover, there was no significant difference between the IC3ST score obtained using the EM navigator and the traditional method (average 22.37 [STD = 7.95] vs. 21.58 [STD = 6.86]; p = .92). Finally, questionnaire results indicate a general agreement concerning the navigator usefulness, which clearly shows the positions of instruments inside the 3D model of the patient's anatomy. Participants also agreed that the navigator can reduce the amount of contrast media delivered to the patient, as well as fluoroscopy time. CONCLUSIONS: This work provides proof of concept that simultaneous EM navigation of guidewires and catheters is feasible without the use of live fluoroscopic images.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Fenômenos Eletromagnéticos , Radiografia Intervencionista , Artéria Renal/diagnóstico por imagem , Terapia Assistida por Computador , Dispositivos de Acesso Vascular , Aneurisma da Aorta Abdominal/terapia , Aortografia/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Competência Clínica , Meios de Contraste , Estudos de Viabilidade , Fluoroscopia , Humanos , Modelos Anatômicos , Modelos Cardiovasculares , Doses de Radiação , Radiografia Intervencionista/métodos , Inquéritos e Questionários , Análise e Desempenho de Tarefas , Terapia Assistida por Computador/instrumentação , Terapia Assistida por Computador/métodos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Gravação em Vídeo
7.
IEEE Rev Biomed Eng ; 16: 348-356, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34061751

RESUMO

In situ fenestration of stent-graft represents a potential option for the treatment of aortic diseases in patients unsuitable for standard endovascular repair. The best fenestration strategy to restore perfusion of collateral vessels after their coverage by an endograft depends mainly on the anatomical area. Several tools are employed as fenestration devices, including needles, radiofrequency probes, and laser systems, used in conjunction with other instrumentation to provide enough support and stability during the procedure. In this systematic review, the approaches to reach the correct fenestration site both in human, animal, and in in vitro environments are described and discussed, highlighting advantages and limitations. Both commercial and dedicated solutions for the intraoperative modification of the fabric material are reported as well. The clinical interest in this procedure has so far encouraged researchers to develop and refine both methods and tools to solve the current limitations of this technique, intending to extend the indications for endovascular treatment to a broader range of patients.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Animais , Humanos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Resultado do Tratamento , Desenho de Prótese , Stents
8.
JDS Commun ; 4(1): 35-39, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36713130

RESUMO

Excellent fertility performance is important to maximize farmers' profit and to reduce the number of culled animals. Although female fertility of adult cows has been included in Italian Holstein breeding objectives since 2009, little has been done to quantify genetic variation of heifer fertility characteristics so far. The aim of the present study was to estimate genetic parameters of 4 fertility traits in nulliparous Italian Holstein heifers and to develop an aggregate selection index to improve heifer fertility. Data were retrieved from the national fertility database and included information on insemination, calving, and pregnancy diagnosis dates. The investigated phenotypes (mean ± standard deviation) were age at first insemination (AFI, mo; 17.25 ± 2.89), nonreturn rate at 56 d from the first insemination (NRR56, binary; 0.78 ± 0.41), conception rate at first insemination (CR, binary; 0.61 ± 0.49), and interval from first to last insemination (IFL, d; 26.09 ± 51.85). Genetic parameters were estimated using a 4-trait animal model that included the following fixed effects: herd-year of birth and month of birth for AFI, and herd-year-season of birth and month-year of insemination for IFL, NRR56, and CR; the animal additive genetic effect (fitted to the pedigree-based relationship matrix) was considered as a random term. An aggregate index was developed from the estimated additive genetic (co)variance matrix by considering CR as the breeding goal and AFI, NRR56, and IFL as selection criteria. Heritability estimates from average covariance matrices ranged from 0.012 (CR) to 0.015 (IFL), with the exception of AFI (0.071). Conception rate at first insemination was strongly correlated with both IFL (-0.730) and NRR56 (0.668), and weakly to AFI (-0.065), and the relative emphasis placed on each selection criteria in the aggregate index was 10%, 47%, and 43% for AFI, IFL, and NRR56, respectively. The results of the present study suggest that heifer fertility should be considered as an additional trait in the breeding objectives of Italian Holstein.

9.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2693-2696, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086410

RESUMO

In the field of image-guided surgery, Augmented Reality wearable displays are a widely studied and documented technology for their ability to provide egocentric vision together with the overlap between real and virtual content. In particular, optical see-through (OST) displays have the advantage of maintaining visual perception of the real world. However, OST displays suffer from vergeance-accomodation conflict when virtual content is superimposed on real world. Furthermore, the calibration methods required to achieve geometric consistency between real and virtual are inherently error-prone. One of the solutions, already studied, to these problems is to use of integral imaging displays. In this paper we present an easy and straightforward real-time rendering strategy implemented in modern OpenGL to show the 3D image of a virtual object on a wearable OST display deploying the integral imaging approach. Clinical Relevance- The algorithm proposed open the way towards more effective AR surgical navigation in terms of comfort of the AR experience and accuracy of the AR guidance.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Algoritmos , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 566-571, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086356

RESUMO

Augmented Reality (AR) can avoid some of the drawbacks of Minimally Invasive Surgery and may provide opportunities for developing innovative tools to assist surgeons. In laparoscopic surgery, the achievement of easy and sufficiently accurate registration is an open challenge. This is particularly true in procedures, such as laparoscopic abdominal Sacro-Colpopexy, where there is a lack of a sufficient number of visible anatomical landmarks to be used as a reference for registration. In an attempt to address the above limitations, we developed and preliminarily testes a constrained manual procedure based on the identification of a single anatomical landmark in the laparoscopic images, and the intraoperative measurement of the laparoscope orientation. Tests in a rigid in-vitro environment show good accuracy (median error 2.4 mm obtained in about 4 min) and good preliminary feedback from the technical staff who tested the system. Further experimentation in a more realistic environment is needed to validate these positive results. Clinical Relevance - This paper provides a new registration method for the development of AR educational videos and AR-based navigation systems for laparoscopic interventions.


Assuntos
Realidade Aumentada , Laparoscopia , Cirurgia Assistida por Computador , Humanos , Imageamento Tridimensional , Laparoscópios , Laparoscopia/métodos , Cirurgia Assistida por Computador/métodos
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3481-3484, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086331

RESUMO

Patient-specific templates (PST) have become a useful tool for guiding osteotomy in complex surgical scenarios such as pelvic resections. The design of the surgical template results in sharper, less jagged resection margins than freehand cuts. However, their correct placement can become difficult in some anatomical regions and cannot be verified during surgery. Conventionally, pelvic resections are performed using Computer Assisted Surgery (CAS), and in recent years Augmented Reality (AR) has been proposed in the literature as an additional tool to support PST placement. This work presents an AR task to simplify and improve the accuracy of the positioning of the template by displaying virtual content. The focus of the work is the creation of the virtual guides displayed during the AR task. The system was validated on a patient-specific phantom designed to provide a realistic setup. Encouraging results have been achieved. The use of the AR simplifies the surgical task and optimizes the correct positioning of the cutting template: an average error of 2.19 mm has been obtained, lower than obtained with state-of-the-art solutions. In addition, supporting PST placement through AR guidance is less time-consuming than the standard procedure that solely relies on anatomical landmarks as reference.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Margens de Excisão , Osteotomia/métodos , Imagens de Fantasmas , Cirurgia Assistida por Computador/métodos
12.
ESMO Open ; 7(2): 100422, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35272132

RESUMO

BACKGROUND: Adrenocortical carcinoma (ACC) is a rare and aggressive malignancy with a poor prognosis. No efficacious treatment options are currently available for patients with advanced metastatic disease with disease progression to standard etoposide, doxorubicin, cisplatin and mitotane (EDP-M) therapy. We assessed the activity and tolerability of cabazitaxel as a second/third-line approach in metastatic ACC. PATIENTS AND METHODS: Patients included in this single-center, phase II study (ClinicalTrials.gov identifier NCT03257891) had disease progression to a cisplatin-containing regimen (such as EDP) plus mitotane, plus/minus a further chemotherapy line. Cabazitaxel was administered intravenously at 25 mg/m2 on day 1 of a 21-day cycle, for a maximum of six cycles. The primary endpoint was a disease control rate after 4 months. RESULTS: From March 2018 to September 2019, 25 eligible patients were enrolled. A disease control rate after 4 months was obtained in six patients (24%). No patients attained a disease response according to RECIST 1.1, 9 patients (36%) had stable disease and 16 patients (64%) progressive disease. Median progression-free survival and overall survival were 1.5 months (range 0.3-7 months) and 6 months (range 1-22.2 months), respectively. Cabazitaxel therapy was well tolerated and only three (12%) patients developed grade 3 toxicity which were nausea in one patient (4%) and anemia in two patients (8%). CONCLUSIONS: Cabazitaxel has a manageable toxicity profile but is poorly active as second/third-line treatment in advanced ACC patients. These results do not support further evaluation of cabazitaxel in this setting.


Assuntos
Neoplasias do Córtex Suprarrenal , Carcinoma Adrenocortical , Neoplasias do Córtex Suprarrenal/tratamento farmacológico , Neoplasias do Córtex Suprarrenal/patologia , Carcinoma Adrenocortical/tratamento farmacológico , Carcinoma Adrenocortical/etiologia , Carcinoma Adrenocortical/patologia , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Cisplatino/efeitos adversos , Progressão da Doença , Humanos , Mitotano/efeitos adversos , Taxoides
13.
Front Mol Biosci ; 9: 842149, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35281256

RESUMO

The family of the human small Heat Shock Proteins (HSPBs) consists of ten members of chaperones (HSPB1-HSPB10), characterized by a low molecular weight and capable of dimerization and oligomerization forming large homo- or hetero-complexes. All HSPBs possess a highly conserved centrally located α-crystallin domain and poorly conserved N- and C-terminal domains. The main feature of HSPBs is to exert cytoprotective functions by preserving proteostasis, assuring the structural maintenance of the cytoskeleton and acting in response to cellular stresses and apoptosis. HSPBs take part in cell homeostasis by acting as holdases, which is the ability to interact with a substrate preventing its aggregation. In addition, HSPBs cooperate in substrates refolding driven by other chaperones or, alternatively, promote substrate routing to degradation. Notably, while some HSPBs are ubiquitously expressed, others show peculiar tissue-specific expression. Cardiac muscle, skeletal muscle and neurons show high expression levels for a wide variety of HSPBs. Indeed, most of the mutations identified in HSPBs are associated to cardiomyopathies, myopathies, and motor neuropathies. Instead, mutations in HSPB4 and HSPB5, which are also expressed in lens, have been associated with cataract. Mutations of HSPBs family members encompass base substitutions, insertions, and deletions, resulting in single amino acid substitutions or in the generation of truncated or elongated proteins. This review will provide an updated overview of disease-related mutations in HSPBs focusing on the structural and biochemical effects of mutations and their functional consequences.

14.
Vet Comp Orthop Traumatol ; 24(4): 279-84, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21674121

RESUMO

OBJECTIVE: To measure the concentrations of nerve growth factor (NGF) in the synovial fluid from normal dogs and dogs with osteoarthritis (OA) secondary to common joint disorders. METHODS: Nerve growth factor synovial concentrations were measured by ELISA assay in 50 dogs divided into three groups: 12 healthy, 16 affected by acute lameness within seven days before enrolment, and 22 with chronic lameness persisting by more than one month before enrolment and accompanied by radiological signs of OA. Both acute and chronic lameness were secondary to orthopaedic diseases involving the shoulder, elbow and stifle joints. Nerve growth factor synovial concentrations were compared between means for healthy and acute groups and between the three groups using an F-test. Significance level was set at p <0.05. RESULTS: Nerve growth factor was detected in all canine synovial fluid samples. However, the mean synovial NGF concentration of healthy dogs (3.65 ± 2.18 pg/ml) was not significantly different from the mean value in dogs with acute lameness (6.45 ± 2.45 pg/ml) (p = 0.79). Conversely, the mean synovial NGF concentration in dogs with chronic lameness (20.19 ± 17.51 pg/ml) was found to be significantly higher than that found in healthy dogs (p <0.01). CLINICAL SIGNIFICANCE: This study demonstrates for the first time the presence of NGF in canine synovial fluid and its increased concentrations in dogs with chronic lameness compared to healthy dogs and dogs with acute lameness. The association between chronic lameness and raised synovial concentrations may suggest an involvement of NGF in OA inflammation and chronic pain.


Assuntos
Doenças do Cão/metabolismo , Fatores de Crescimento Neural/análise , Osteoartrite/veterinária , Líquido Sinovial/química , Envelhecimento , Animais , Cães , Feminino , Coxeadura Animal , Masculino , Fatores de Crescimento Neural/metabolismo , Osteoartrite/metabolismo
15.
J Anesth Analg Crit Care ; 1(1): 24, 2021 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-37386530

RESUMO

BACKGROUND: Life-threatening streptococcal sepsis nowadays represents an uncommon event in previously healthy infants and children. Critically ill patients suffering from severe streptococcal sepsis complications may present with pre-antibiotic era clinical pictures and require a timely clinical approach to achieve restitutio ad integrum. RESULTS: We report a series of four patient groups affected by an uncommon life-threatening streptococcal sepsis, each of them exhibiting some distinct features. Streptococcus Agalactiae sepsis was associated with cerebral thrombotic/ischaemic lesions, whereas severe cardiogenic shock was prominent in the Streptococcus Viridans group; Streptococcus Faecalis and ß-hemolytic group A Streptococcus patients mostly reported lung complications. CONCLUSIONS: Previous antibiotic treatments should not delay aggressive treatment in the intensive care setting. Early diagnostic suspicion, as well as appropriate and aggressive treatment provided within an intensive care setting are crucial for the clinical outcome.

16.
Artigo em Inglês | MEDLINE | ID: mdl-31796397

RESUMO

A novel quartz crystal resonator (QCR) sensor with a printed-on-crystal conductive coil, named sensor coil, is presented. The sensor coil electromagnetically coupled to an external readout coil allow to perform contactless interrogation of the QCR working as a stand-alone sensor unit. A frequency-domain readout technique is adopted that allows dual-harmonic operation by detecting the QCR frequencies of the fundamental and third harmonic, and offers first-order independence from the stand-off distance between the sensor and the readout unit. The QCR electrodes and sensor coil have been printed on a 330- [Formula: see text]-thick bare AT-cut quartz crystal exploiting the aerosol jet printing technology. The fabricated QCR sensor has reference values of the fundamental and third harmonic frequencies at 4.77 and 14.22 MHz, respectively. Distance-independent contactless operation has been demonstrated for distances up to 12 mm. The readout frequencies deviate from reference values less than 10 and 90 ppm for the fundamental and third harmonic, respectively, thus validating the proposed principle.

17.
IEEE J Transl Eng Health Med ; 8: 1900208, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32219042

RESUMO

Objective: This work aims at providing novel endovascular instrumentation to overcome current technical limitations of in situ endograft fenestration including challenges in targeting the fenestration site under fluoroscopic control and supplying mechanical support during endograft perforation. Technology: Novel electromagnetically trackable instruments were developed to facilitate the navigation of the fenestration device and its stabilization at the target site. In vitro trials were performed to preliminary evaluate the proposed instrumentation for the antegrade in situ fenestration of an aortic endograft, using a laser guidewire designed ad hoc and the sharp end of a commercial endovascular guidewire. Results: In situ fenestration was successfully performed in 22 trials. A total of two laser tools were employed since an over bending of laser guidewire tip, due to its manufacturing, caused the damage of the sensor in the first device used. Conclusions: Preliminary in vitro trials demonstrate the feasibility of the proposed instrumentation which could widespread the procedure for in situ fenestration. The results obtained should be validated performing animal studies. Clinical Impact: The proposed instrumentation has the potential to expand indications for standard endovascular aneurysm repair to cases of acute syndromes.

18.
J Wildl Dis ; 45(3): 828-33, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19617496

RESUMO

In avian medicine, hematologic and biochemical laboratory investigations are still in their infancy, because of the difficulty involved in collecting data. This has led to a lack of reference values and a nonstandardized approach to specimens obtained in critical conditions. The Eurasian Buzzard (Buteo buteo) is one of the most common raptors in Italy, yet little is known about the physiologic blood parameters of this species. Serum biochemistry and electrophoretic investigations were performed in 40 healthy Eurasian Buzzards in different Italian wildlife rescue centers waiting to be released after recovering from trauma injuries. Mean values for biochemistry parameters were pancreatic amylase 626.9 IU/l, uric acid 7.5 mg/dl, aspartate aminotransferase 330.9 IU/l, glucose 375.1 mg/dl, lipase 26.3 IU/ l, total protein 38.4 g/l, total bilirubin 0.04 mg/ dl, lactate dehydrogenase 2,008.4 IU/l, creatinine kinase 1,604.1 IU/l, alanine aminotransferase 40.4 IU/l, alkaline phosphatase 89.8 IU/l, magnesium 2.3 mg/dl, calcium 10.2 mg/dl, phosphorus 2.02 mg/dl, cholesterol 192.2 mg/ dl, triglyceride 116.4 mg/dl, albumin 14.5 g/l, creatinine 0.1 mg/dl. Mean electrophoretic values were prealbumin 1.4 g/l, albumin 14.2 g/l, alpha 1 globulin 5.9 g/l, alpha 2 globulin 4.7 g/l, beta globulin 7.5 g/l, gamma globulin 3.6 g/l, albumin/globulins ratio 0.8 g/l.


Assuntos
Proteínas Aviárias/análise , Análise Química do Sangue/veterinária , Proteínas Sanguíneas/análise , Falconiformes/sangue , Animais , Eletroforese das Proteínas Sanguíneas/veterinária , Feminino , Itália , Masculino , Valores de Referência , Especificidade da Espécie
19.
Rev Esp Anestesiol Reanim (Engl Ed) ; 66(9): 467-473, 2019 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31564449

RESUMO

Accurate oxygen consumption measurement (VO2), is essential to obtain a reliable hemodynamic assessment, particularly in patients with congenital heart diseases undergoing cardiac catheterization. LaFarge equations can be unreliable in predicting VO2, particularly in the pediatric population. In a clinical setting, these inaccurate estimates can lead to important hemodynamic parameter miscalculations, with possible therapeutic or diagnostic consequences. Our aim is to validate LaFarge equations (the most widely used for estimating VO2) and compare them with direct measurement in children during cardiac catheterization in the cath lab. We performed a prospective observational study in 21 patients (0-3 years of age) with different congenital cardiac diseases, scheduled for diagnostic cardiac catheterization. Under general anesthesia and mechanical ventilation, VO2 was measured directly with a metabolic module in our cath lab, and also estimated using LaFarge equations. Statistical analysis included Bland-Altman plots, Pearson coefficient and percentage error, among others. LaFarge equations overestimated VO2 values in all study patients. Therefore, in pediatric patients under 3 years of age, the use of direct VO2 measurement methods are more accurate and acceptable than LaFarge equations.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas/fisiopatologia , Consumo de Oxigênio/fisiologia , Algoritmos , Pré-Escolar , Intervalos de Confiança , Humanos , Lactente , Recém-Nascido , Estudos Prospectivos
20.
Hand Surg Rehabil ; 38(2): 129-134, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30641152

RESUMO

In cases of transverse congenital forearm deficiency, achieving a good prosthesis fit during childhood remains a challenge. Ulnar lengthening is a treatment option for improving the prosthesis fit. The objective of this study was to evaluate surgical ulnar lengthening and the subsequent prosthesis fit. We reviewed four cases of ulnar lengthening in children with transverse congenital forearm deficiency. The procedure was evaluated in terms of the duration of lengthening, increase in ulnar length and healing index. The elbow range of motion, functional outcome (Prosthetic Upper Extremity Functional Index, PUFI) and time spent using the prosthesis per day were evaluated. The mean age at the time of the lengthening procedure was 3.5 years, the mean duration of lengthening was 58.3 days, the mean length gain was 21 mm, and the mean healing index was 70.1 days/cm. Elbow range of motion was restricted in one patient (100°-140°) and full in the other three patients. Based on the PUFI, 88.4% of activities were performed without the prosthesis. Children only used their prosthesis to perform specific tasks. Given the high complication rate and the lack of prosthesis use during daily activities, the main indication for forearm lengthening is a very short forearm that prevents prosthesis fitting. This procedure should be performed later in life - in adolescence.


Assuntos
Membros Artificiais , Alongamento Ósseo/métodos , Fixadores Externos , Ulna/anormalidades , Ulna/cirurgia , Adolescente , Cartilagem/transplante , Criança , Pré-Escolar , Articulação do Cotovelo/fisiologia , Feminino , Lâmina de Crescimento/transplante , Humanos , Ílio/transplante , Masculino , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA