Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Radiographics ; 43(7): e220153, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37384544

RESUMO

Transcatheter tricuspid valve interventions (TTVIs) comprise a variety of catheter-based interventional techniques for treatment of tricuspid regurgitation (TR) in patients at high surgical risk and those with failed previous surgeries. Several TTVI devices with different mechanisms of action are either currently used or in preclinical evaluation. Echocardiography is the first-line modality for evaluation of tricuspid valve disease that provides information on tricuspid valve morphology, mechanism of TR, and hemodynamics. Cardiac CT and MRI have several advantages for a comprehensive preprocedure evaluation. CT and MRI provide complementary information to that of echocardiography on the mechanism and cause of TR. MRI can quantify the severity of TR using indirect or direct techniques that involve two-dimensional or four-dimensional flow sequences. MRI and CT can also accurately quantify right ventricular volumes and function, which is crucial for timing of intervention. CT provides comprehensive three-dimensional information on the morphology of the valve, annulus, subvalvular apparatus, and adjacent structures. CT is the procedure of choice for evaluation of several device-specific measurements, including tricuspid annulus dimensions, annulus-to-right coronary artery distance, leaflet morphology, coaptation gaps, caval dimensions, and cavoatrial-to-hepatic vein distance. CT allows evaluation of the vascular access as well as optimal procedure fluoroscopic angles and catheter trajectory. Postprocedure CT and MRI are useful in detection of complications such as paravalvular leak, pseudoaneurysm, thrombus, pannus, infective endocarditis, and device migration. © RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Falso Aneurisma , Doenças das Valvas Cardíacas , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Imageamento por Ressonância Magnética , Ecocardiografia
2.
Radiographics ; 42(4): 991-1011, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35687519

RESUMO

Transcatheter pulmonary valve replacement (TPVR) is a minimally invasive procedure for treatment of right ventricular outflow tract (RVOT) dysfunction in surgically repaired congenital heart diseases. TPVR is performed in these patients to avoid the high risk and complexity of repeat surgeries. Several TPVR devices are now available to be placed in the right ventricle (RV) to pulmonary artery (PA) conduit, native RVOT, or surgical bioprosthetic valves. Imaging is used before TPVR to determine patient eligibility and optimal timing, which is critical to avoid irreversible RV dilatation and failure. Imaging is also required for evaluation of contraindications, particularly proximity of the RVOT to the left main coronary artery and its branches. Cross-sectional imaging provides details of the complex anatomy in which the TPVR device will be positioned and measurements of the RVOT, RV-PA conduit, or PA. Echocardiography is the first-line imaging modality for evaluation of the RVOT or conduit to determine the need for intervention, although its utility is limited by the complex RVOT morphology and altered anatomy after surgery. CT and MRI provide complementary information for TPVR, including patient eligibility, assessment of contraindications, and key measurements of the RVOT and PA, which are necessary for procedure planning. TPVR, performed using a cardiac catheterization procedure, includes a sizing step in which a balloon is expanded in the RVOT, which also allows assessment of the risk for extrinsic coronary artery compression. Follow-up imaging with CT and MRI is used for evaluation of postprocedure remodeling and valve function and to monitor complications. ©RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Cardiopatias Congênitas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Ecocardiografia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
3.
J Mol Cell Cardiol ; 135: 31-39, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31348923

RESUMO

BACKGROUND: Predictors of thoracic aorta growth and early cardiac surgery in patients with bicuspid aortic valve are undefined. Our aim was to identify predictors of ascending aorta dilatation and cardiac surgery in patients with bicuspid aortic valve (BAV). METHODS: Forty-one patients with BAV were compared with 165 patients with tricuspid aortic valve (TAV). All patients had LV EF > 50%, normal LV dimensions, and similar degree of aortic root or ascending aorta dilatation at enrollment. Patients with more than mild aortic stenosis or regurgitation were excluded. A CT-scan was available on 76% of the population, and an echocardiogram was repeated every year for a median time of 4 years (range: 2 to 8 years). Patterns of aortic expansion in BAV and TAV groups were analyzed by a mixed-effects longitudinal linear model. In the time-to-event analysis, the primary end point was elective or emergent surgery for aorta replacement. RESULTS: BAV patients were younger, while the TAV group had greater LV wall thickness, arterial hypertension, and dyslipidemia than BAV patients. Growth rate was 0.46 ±â€¯0.04 mm/year, similar in BAV and TAV groups (p = 0.70). Predictors of cardiac surgery were aorta dimensions at baseline (HR 1.23, p = 0.01), severe aortic regurgitation developed during follow-up (HR 3.49, p 0.04), family history of aortic aneurysm (HR 4.16, p 1.73), and history of STEMI (HR 3.64, p < 0.001). CONCLUSIONS: Classic baseline risk factors were more commonly observed in TAV aortopathy compared with BAV aortopathy. However, it is reassuring that, though diagnosed with aneurysm on average 10 years earlier and in the absence of arterial hypertension, BAV patients had a relatively low growth rate, similar to patients with a tricuspid valve. Irrespective of aortic valve morphology, patients with a family history of aortic aneurysm, history of coronary artery disease, and those who developed severe aortic regurgitation at follow-up, had the highest chances of being referred for surgery.


Assuntos
Aorta , Estenose da Valva Aórtica , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas , Tomografia Computadorizada por Raios X , Valva Tricúspide , Idoso , Aorta/diagnóstico por imagem , Aorta/fisiopatologia , Aorta/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/fisiopatologia , Dilatação Patológica/cirurgia , Dislipidemias/diagnóstico por imagem , Dislipidemias/fisiopatologia , Dislipidemias/cirurgia , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Hipertensão/cirurgia , Masculino , Pessoa de Meia-Idade , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia
4.
Catheter Cardiovasc Interv ; 92(7): E537-E549, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-29359388

RESUMO

INTRODUCTION: Three-dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR). METHODS: Eight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre-procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result. RESULTS: 3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post-procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model. CONCLUSION: 3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Estudos de Viabilidade , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Modelos Anatômicos , Modelos Cardiovasculares , Complicações Pós-Operatórias/etiologia , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
Curr Cardiol Rep ; 20(6): 47, 2018 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-29749577

RESUMO

PURPOSE OF REVIEW: To highlight the various applications of 3D printing in cardiovascular disease and discuss its limitations and future direction. RECENT FINDINGS: Use of handheld 3D printed models of cardiovascular structures has emerged as a facile modality in procedural and surgical planning as well as education and communication. Three-dimensional (3D) printing is a novel imaging modality which involves creating patient-specific models of cardiovascular structures. As percutaneous and surgical therapies evolve, spatial recognition of complex cardiovascular anatomic relationships by cardiologists and cardiovascular surgeons is imperative. Handheld 3D printed models of cardiovascular structures provide a facile and intuitive road map for procedural and surgical planning, complementing conventional imaging modalities. Moreover, 3D printed models are efficacious educational and communication tools. This review highlights the various applications of 3D printing in cardiovascular diseases and discusses its limitations and future directions.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Modelos Anatômicos , Modelos Cardiovasculares , Impressão Tridimensional/tendências , Humanos , Interpretação de Imagem Assistida por Computador , Modelagem Computacional Específica para o Paciente/tendências
6.
AJR Am J Roentgenol ; 208(3): 552-563, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28225687

RESUMO

OBJECTIVE: The purpose of this study is to determine whether image quality was maintained when a weight-based protocol incorporating tube potential selection was used to select lower iodine contrast volumes for aortic CT angiography (CTA). MATERIALS AND METHODS: Patients with potentially decreased renal function underwent CTA performed with the iodinated contrast volume determined using a table incorporating different tube potentials and patient weights. The image quality of CTA examinations performed with a reduced iodine volume (hereafter known as "low-iodine CTA examinations"), internal control CTA examinations (i.e., prior examinations), and size-matched control CTA examinations was evaluated in separate reading sessions conducted by three vascular radiologists who were blinded as to the contrast volume and tube potential used. Side-by-side unblinded comparison of the examinations was also performed. Aortic attenuation and the contrast-to-noise ratio were measured. Comparisons were performed using the Wilcoxon signed rank test. RESULTS: Fifty low-iodine CTA examinations, 36 internal control CTA examinations, and 50 size-matched control CTA examinations were performed. Contrast volumes were 63% lower when the protocol based on tube potential and patient weight was used (mean contrast volume, 49 mL for low-iodine CTA vs 133 mL for internal control CTA and 138 mL for size-matched control CTA). The mean volume CT dose index was 15.1 mGy for low-iodine CTA versus 18.8 mGy for internal control CTA (p < 0.001), and 15.3 mGy for low-iodine CTA versus 17.1 mGy for size-matched control CTA (p = 0.11). Of the image quality and diagnostic confidence evaluations for low-iodine CTA examinations, over 97% had acceptable image quality and diagnostic confidence for blinded (50/50) and unblinded (35/36) comparisons. Aortic attenuation was similar between groups (p = 0.13-0.71). CONCLUSION: A weight-based protocol that incorporates tube potential selection allows the use of substantially lower volumes of iodinated contrast material in aortic CTA while maintaining acceptable image quality.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada/métodos , Iodo/administração & dosagem , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Adulto Jovem
7.
Eur Heart J ; 37(8): 693-9, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26508159

RESUMO

AIMS: Calcific aortic valve stenosis (AS) is purportedly associated with less calcium burden in women than in men. We sought to examine sex-related differences and correlates of surgically excised aortic valve weight (AVW) in pure AS. METHODS AND RESULTS: Clinical and echocardiographic characteristics of 888 consecutive patients who underwent aortic valve replacement for severe AS were correlated to AVW, and in 126 patients, AVW was also correlated to computed tomography aortic valve calcium (AVC) score. Women and men had similar indexed valve area (0.42 ± 0.09 vs. 0.42 ± 0.07 cm (2)/m(2), P = 0.95) and mean systolic gradient (53 ± 15 vs. 52 ± 13 mmHg, P = 0.11), but women had higher New York Heart Association class (2.63 ± 0.70 vs. 2.50 ± 0.70, P = 0.01) and less prevalent coronary artery disease (38 vs. 52%, P < 0.0001). Aortic valve weight was lower in women (1.94 ± 0.88 vs. 3.08 ± 1.32 g, P < 0.0001) even when indexed to body surface area (1.09 ± 0.48 vs. 1.48 ± 0.62 g/m(2), P < 0.0001) or left ventricular outflow tract (LVOT) area (0.54 ± 0.23 vs. 0.71 ± 0.29 g/cm(2), P < 0.0001). Using multivariate analysis, male sex (P < 0.0001), bicuspid valve (P < 0.0001), and larger LVOT area (P < 0.0001) were the major determinants of increased AVW, along with current cigarette smoking (P = 0.007). Diabetes (P = 0.004) and hypertension (P = 0.03) were independently associated with lower AVW. Aortic valve calcium correlated well with AVW (r = 0.81, P < 0.0001) and was lower in women than in men (2520 ± 1199 vs. 3606 ± 1632 arbitrary units, P < 0.0001). CONCLUSIONS: Despite the same degree of AS severity, women have less AVC and lower AVW compared with men, irrespective of valve morphology. Aortic valve calcium is correlated to excised AVW. Hypertension, diabetes, and current cigarette smoking were independently associated with AVW.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Calcinose/diagnóstico por imagem , Caracteres Sexuais , Adulto , Distribuição por Idade , Idoso , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Calcinose/patologia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Cuidados Pré-Operatórios , Tomografia Computadorizada por Raios X
8.
Echocardiography ; 33(10): 1539-1545, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27546353

RESUMO

PURPOSE: Infarct mass as assessed by myocardial-delayed enhancement imaging on cardiac magnetic resonance (CMR) and myocardial blood flow as assessed by real time myocardial perfusion echocardiography (RT-MPE) have been shown to predict adverse events following ST elevation myocardial infarction (STEMI). There has been no published comparison of quantitative assessment using these modalities as predictors of clinical outcomes to date. We compared RT-MPE with CMR for prediction of cardiac events in reperfused STEMI patients. MATERIALS AND METHODS: Consecutive STEMI patients with early reperfusion were studied. RT-MPE and CMR were performed. Perfusion score indices (PSIRT-MPE and PSICMR ) were calculated [sum of segmental perfusion scores/number of segments]. CMR infarct mass (g) and RT-MPE myocardial blood flow (MBF dB/s) were quantified. Patients were followed for cardiac events (death, nonfatal MI, revascularization, angina, and heart failure). RESULTS: All 27 patients (age 62±14; follow-up 3.5±2.6 years) had thrombolysis in myocardial infarction (TIMI) grade 3 flow of infarct vessel. Cardiac events occurred in 17 (63%). Cardiac event patients had higher PSIRT-MPE , PSICMR , infarct mass, and lower MBF. PSIRT-MPE cutoff of 0.3 had an AUC of 0.856 (82% sensitivity, 70% specificity), while a PSICMR cutoff of 0.2 had an AUC of 0.765 (76% sensitivity, 60% specificity). Infarct mass and MBF were independent predictors of cardiac events after adjusting for risk factors (hazard ratios: 20.9 [95% CI 1.8-256] P=.02 and 8.1 [95% CI 1.5-78] P=.01, respectively). CONCLUSIONS: Quantitative RT-MPE performed comparably to CMR for prediction of MACE in STEMI patients supporting a prognostic role for this noninvasive, bedside imaging method.


Assuntos
Ecocardiografia/métodos , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/cirurgia , Imagem de Perfusão do Miocárdio/métodos , Revascularização Miocárdica/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota/epidemiologia , Infarto do Miocárdio/mortalidade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Resultado do Tratamento
9.
Radiographics ; 35(7): 1989-2006, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26562234

RESUMO

Radiologists will be at the center of the rapid technologic expansion of three-dimensional (3D) printing of medical models, as accurate models depend on well-planned, high-quality imaging studies. This article outlines the available technology and the processes necessary to create 3D models from the radiologist's perspective. We review the published medical literature regarding the use of 3D models in various surgical practices and share our experience in creating a hospital-based three-dimensional printing laboratory to aid in the planning of complex surgeries.


Assuntos
Impressão Tridimensional , Impressão , Diagnóstico por Imagem , Humanos , Exame Físico
11.
Heart ; 110(8): 594-602, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-37903555

RESUMO

OBJECTIVE: CT aortic valve calcium score (AVCscore) and density (AVCdensity) thresholds have been recommended for aortic stenosis (AS) severity assessment in tricuspid aortic valve (TAV). We aimed to compare AVCscore and AVCdensity in bicuspid aortic valve (BAV) versus TAV. METHODS: Retrospective single-centre study of patients with echocardiographic AS-severity and CT-AVC assessments within 6 months, and left ventricular ejection fraction ≥50%, all referred for clinical AS evaluation.Severe AS was defined as aortic valve area (AVA) ≤1 cm2 or indexed AVA ≤0.6cm2/m2 plus mean gradient ≥40 mm Hg or peak velocity ≥4 m/s. AVC was assessed by Agatston method. RESULTS: Of the 1957 patients, 328 had BAV and 1629 had TAV, age 65±11 vs 80±9 years (p<0.001), men 65% vs 56% (p=0.006), respectively. BAV morphology was associated with higher AVCscore and AVCdensity independent of age, comorbidities and AS severity (p<0.001) in men only (sex and BAV interaction p<0.001). In patients with severe AS, mean AVCscore and AVCdensity were higher in BAV-men than that in TAV-men (both p<0.001), but similar in BAV-women and TAV-women (both p≥0.4). Such patterns remained the same after adjustment for clinical covariates and AS severity. Best thresholds for severe AS diagnosis in BAV-men were 2916 AU by AVCscore and 600 AU/cm2 by AVCdensity which were higher than the guideline-recommended thresholds, while thresholds in BAV-women (1036 AU and 282 AU/cm2) were similar to guideline-recommended ones. CONCLUSION: Valve calcification in AS differs according to valve morphology and sex. BAV-men with severe AS exhibit greater AVCscore and AVCdensity than TAV-men. This presents a diagnostic challenge to the current guidelines, which needs confirmation in larger studies.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Cálcio , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
12.
Phys Med Biol ; 69(3)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38181426

RESUMO

Objectives.To improve quality of coronary CT angiography (CCTA) images using a generalizable motion-correction algorithm.Approach. A neural network with attention gate and spatial transformer (ATOM) was developed to correct coronary motion. Phantom and patient CCTA images (39 males, 32 females, age range 19-92, scan date 02/2020 to 10/2021) retrospectively collected from dual-source CT were used to create training, development, and testing sets corresponding to 140- and 75 ms temporal resolution, with 75 ms images as labels. To test generalizability, ATOM was deployed for locally adaptive motion-correction in both 140- and 75 ms patient images. Objective metrics were used to assess motion-corrupted and corrected phantom and patient images, including structural-similarity-index (SSIM), dice-similarity-coefficient (DSC), peak-signal-noise-ratio (PSNR), and normalized root-mean-square-error (NRMSE). In objective quality assessment, ATOM was compared with several baseline networks, including U-net, U-net plus attention gate, U-net plus spatial transformer, VDSR, and ResNet. Two cardiac radiologists independently interpreted motion-corrupted and -corrected images at 75 and 140 ms in a blinded fashion and ranked diagnostic image quality (worst to best: 1-4, no ties).Main results. ATOM improved quality metrics (p< 0.05) before/after correction: in phantom, SSIM 0.87/0.95, DSC 0.85/0.93, PSNR 19.4/22.5, NRMSE 0.38/0.27; in patient images, SSIM 0.82/0.88, DSC 0.88/0.90, PSNR 30.0/32.0, NRMSE 0.16/0.12. ATOM provided more consistent improvement of objective image quality, compared to the presented baseline networks. The motion-corrected images received better ranks than un-corrected at the same temporal resolution (p< 0.05): 140 ms images 1.65/2.25, and 75 ms images 3.1/3.2. The motion-corrected 75 ms images received the best rank in 65% of testing cases. A fair-to-good inter-reader agreement was observed (Kappa score 0.58).Significance. ATOM reduces motion artifacts, improving visualization of coronary arteries. This algorithm can be used to virtually improve temporal resolution in both single- and dual-source CT.


Assuntos
Artefatos , Tomografia Computadorizada por Raios X , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Movimento (Física) , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos
13.
Front Cardiovasc Med ; 11: 1340406, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38327492

RESUMO

A 73-year-old woman presented to the emergency department with a syncopal episode and a history of dizzy spells. A transthoracic echocardiogram demonstrated a large left atrial mass extending into the right upper pulmonary veins. Subsequently, cardiac magnetic resonance imaging and coronary computed tomography angiography with three-dimensional reconstruction and printing of the heart and mass were performed, which demonstrated a high index of suspicion for an atypical left atrial myxoma. The mass was excised robotically, and the pathology report confirmed a diagnosis of myxoma.

14.
AJR Am J Roentgenol ; 200(5): 980-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617479

RESUMO

OBJECTIVE: The use of contrast-enhanced MR angiography (MRA) as an alternative to CT angiography or conventional angiography to assess pediatric and adult patients with cardiovascular diseases has the potential to significantly reduce patients' lifetime exposure to ionizing radiation. However, imaging this group of patients can be challenging because of a number of factors, including small size, difficulty timing the contrast bolus to the territory of interest, and the presence of metallic susceptibility artifact resulting from stents or clips. CONCLUSION: We present some suggestions to overcome many of these obstacles to MRA in these patients, highlighted with illustrations from clinical cases.


Assuntos
Cardiopatias Congênitas/diagnóstico , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Adulto Jovem
15.
AJR Am J Roentgenol ; 200(6): W581-92, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23701088

RESUMO

OBJECTIVE: We provide an outline of aortic anatomy and disease patterns, describe methods of aortic measurement, and highlight measurement thresholds for surgical intervention. We also discuss findings that can assist in preoperative planning and in detecting underlying connective tissue disorders. CONCLUSION: A standardized approach to the measurement of the aorta is needed and features suggestive of an underlying connective tissue disorder should be recognized. Radiologists should be aware of the image limitations and clinical implications of reported measurements.


Assuntos
Doenças da Aorta/diagnóstico , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Aorta/anatomia & histologia , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Humanos , Imageamento Tridimensional
16.
Cardiovasc Diagn Ther ; 13(1): 196-211, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36864955

RESUMO

Arteriovenous fistulas (AVFs) and grafts (AVGs) are the preferred forms of vascular access for hemodialysis in patients with severe renal dysfunction. Multimodality imaging plays an important role in the pre-procedural evaluation of these patients. Ultrasound is often used for pre-procedural vascular mapping in preparation for the creation of an AVF or AVG. Pre-procedural mapping includes a comprehensive evaluation of the arterial and venous vasculature including evaluation of vessel diameter, stenosis, course, presence of collateral veins, wall thickness and wall abnormalities. Computed tomography (CT), magnetic resonance imaging (MRI) or catheter angiography are used when sonography is not available or when further characterization of sonographic abnormalities is required. Following the procedure, routine surveillance imaging is not recommended. If there are any clinical concerns or if physical examination is inconclusive, further evaluation with ultrasound is warranted. Ultrasound allows for assessment of vascular access site maturation by evaluating the time-averaged blood flow and helping characterize the outflow vein in the case of an AVF. CT and MRI can play a complementary role to ultrasound. Vascular access site complications include non-maturation, aneurysm, pseudoaneurysm, thrombosis, stenosis, steal phenomena or occlusion typically of the outflow vein, infection, bleeding and rarely angiosarcoma. In this article, we review the role of multimodality imaging in the pre- and post-procedural evaluation of patients with AVF and AVG. Additionally, novel technologies of vascular access site creation using endovascular techniques and upcoming non-invasive imaging techniques for evaluation of AVFs and AVGs are discussed.

17.
Struct Heart ; 7(1): 100100, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37275308

RESUMO

Background: Severe tricuspid regurgitation (TR) is associated with considerable morbidity/mortality in an elderly population with multiple comorbidities. There is interest in transcatheter interventions to manage severe TR. Understanding complex right heart (RH) geometry and tricuspid valve shape and size has implications for patient/device selection for transcatheter intervention. We characterized RH anatomy by computed tomography in patients with symptomatic severe TR considered for intervention. Methods: The retrospective Mayo Clinic study included 29 patients with an echocardiogram and cardiac computed tomography angiogram considered for intervention of severe TR from March 01, 2016 to December 15, 2020. Patients were divided into 2 groups: intervention (surgical or transcatheter; n = 17) and medical management alone (n = 12). Results: Mean age was 83 ± 8 (83% female), 100% had atrial fibrillation, and 62% had chronic kidney disease ≥3a. Ninety-seven percent were symptomatic, 93% had been prescribed loop diuretics, and 24% had device leads. Mean tricuspid annular plane systolic excursion was 16.8 ± 4.5 mm, effective regurgitant orifice area was 81 ± 33 mm2, and cardiac index was 2.6 ± 0.6 L/min/m2. Forty-one percent had at least moderate right ventricular (RV) dysfunction with a mean RV systolic pressure of 46 ± 16 mmHg. Patients receiving intervention had significantly larger effective regurgitant orifice area (101 ± 33 vs. 63 ± 22 mm2, p = 0.033), shorter tricuspid leaflet tenting length (6.5 ± 3.0 vs. 8.9 ± 2.7 mm, p = 0.042), and smaller annuloplasty diagnostic perimeter during diastole (120.1 ± 16.6 vs. 131.1 ± 7.4 mm, p = 0.041). Intervention patients tended to have better right ventricular function, smaller RV and inferior vena cava size, and more severe symptoms. The maximal tricuspid annulus diameter in systole and diastole was 51 ± 5 and 53 ± 7 mm, respectively. Conclusions: Severe TR patients referred for transcatheter intervention present with severe RH enlargement with a large proportion having tricuspid annulus dimensions outside the range for current devices available in clinical trials. The presented data have implications for device development/selection and procedural feasibility.

18.
Mayo Clin Proc Innov Qual Outcomes ; 7(4): 309-319, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37502339

RESUMO

Objectives: To determine whether ultrasound enhancing agent (UEA) changes maximal wall thickness (WT) in hypertrophic cardiomyopathy (HCM), and if it improves correlation with magnetic resonance imaging (MRI). Patients and Methods: A total of 107 patients with HCM were prospectively enrolled at a single tertiary referral center between July 10, 2014, and August 31, 2017, and underwent transthoracic echocardiography (TTE) with and without UEA and MRI. Maximal WT measurements were compared, and variability among the 3 modalities was evaluated using a simple linear regression analysis and paired t tests and Bland-Altman plots. Interobserver variability for each technique was assessed. Results: Most (63%) of cardiac imagers found UEA helpful in determining maximal WT by TTE, with 49% reporting change in WT. Of 52 patients where UEA changed WT measurement, 32 (62%) reported an increase and 20 (38%) reported a decrease in WT. The UEA did not alter the median discrepancy in WT between MRI and TTE. However, where UEA increased reported WT, the difference between MRI and TTE improved in 79% of cases (P=.001) from 2.0-0.5mm. In those with scar on MRI, UEA improved agreement of WT between TTE and MRI compared with that of TTE without UEA (79% vs 39%; P=.011). Interclass correlation coefficient for WT for TTE without UEA, with UEA, and MRI was 0.84; (95% CI, 0.61-0.92), 0.88; (95%CI, 0.82-0.92), and 0.97; (95%CI, 0.96-0.98), respectively. Conclusion: Although use of UEA did not eliminate differences in WT discrepancy between modalities, the addition of UEA to TTE aided in WT determination and improved correlation with MRI in those with greater WT and in all patients with myocardial scars.

19.
World J Pediatr Congenit Heart Surg ; 13(1): 113-116, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34550031

RESUMO

Three-dimensional (3D) modeling has become an invaluable tool for operative planning in the continually evolving complex field of adult congenital heart surgery. We present a case of an intra-atrial conduit leak after multiple repairs of common atrium and criss-cross morphology. 3D modeling was critical in preoperative evaluation and operative planning for complicated intracardiac anatomy after an uncommon initial approach to preserve a biventricular circulation. In the setting of complex or rare congenital cardiac anomalies, advanced imaging and 3D modeling are helpful with preoperative planning.


Assuntos
Coração Entrecruzado , Cardiopatias Congênitas , Veias Pulmonares , Adulto , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Imageamento Tridimensional , Próteses e Implantes
20.
JACC Case Rep ; 4(14): 871-877, 2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35912325

RESUMO

Intrapericardial paragangliomas are rare, highly vascular tumors that frequently adhere to adjacent structures and blood vessels, making surgical resection challenging. In this case series, we discuss the role of multimodality imaging and preoperative embolization in the management of 3 patients presenting with intrapericardial paragangliomas. (Level of Difficulty: Advanced.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA