Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Indian J Thorac Cardiovasc Surg ; 35(1): 55-58, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33060970

RESUMO

The transcarotid pathway remains a safe route for transcatheter aortic valve implantation (TAVI) when more traditional approaches are contraindicated. We report a series of three patients with severe aortic stenosis (AS) and symptomatic significant stenosis of the ipsilateral internal carotid artery (ICA) in patients with high operative risk. All patients were treated successfully within the same setting in our center by endarterectomy first followed by a TAVI with an uneventful postoperative course without new neurological deficits (Modine et al. in J Thorac Cardiovasc Surg. 140:928-9, 2010; Azmoun et al. in Eur J Cardiothorac Surg. 46:693-8, 2014; Overtchouk et al. in Ann Cardiothorac Surg. 6(5):555-7, 2017).

2.
Ann Thorac Surg ; 99(4): 1220-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25728963

RESUMO

BACKGROUND: Although reduction of a dilated aortic annulus is becoming an essential parameter for durable valve repair, anatomical descriptions of the annulus and surgical landmarks of the subvalvular plane for an external aortic annuloplasty remain to be defined. METHODS: Twenty hearts with normal anatomy with tricuspid aortic valves were studied. Annulus diameter, cusp geometric height, and interleaflet triangles heights were measured. The aortic root was dissected externally down to the subvalvular plane as to perform an external aortic annuloplasty or reimplantation procedure proximal anastomosis. Tissue thickness and dissection heights relative to the annulus were measured at each cusp nadir and at the middle of each interleaflet triangle. RESULTS: The mean annulus diameter, cusp geometric height, and interleaflet triangle heights were, respectively, 24.9 ± 0.2 mm, 19.7 ± 0.3 mm, and 20.1 ± 0.5 mm. External dissection of the aortic root reached the subvalvular plane below the nadir of left coronary cusp (-2.7 ± 0.4 mm), noncoronary (NC) cusp (-3.1 ± 0.3 mm), and the base of left-NC interleaflet triangle (-2.1 ± 0.4 mm). External dissection remained above the nadir of the right coronary cusp (+1.4 ± 0.4 mm), base of left-right interleaflet triangle (+2.4 ± 0.6 mm), and right-NC interleaflet triangle (+3.4 ± 0.3 mm). Mean tissue thickness between the inner and external side of the subvalvular plane was 2.5 ± 0.1 mm. CONCLUSIONS: External dissection of the aortic annulus allows subvalvular placement of an external aortic ring below the left and NC cusps and below or within 3 mm of the right cusp nadir in 80% of cases. An external aortic annuloplasty would induce at least a 5-mm reduction of annulus diameter, corresponding to tissue thickness. Precise anatomical landmarks are important to standardize aortic valve annuloplasty.


Assuntos
Valva Aórtica/anatomia & histologia , Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Pontos de Referência Anatômicos , Cadáver , Dissecação , Educação Médica Continuada , Feminino , Humanos , Masculino , Valores de Referência , Valva Tricúspide/anatomia & histologia , Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA