Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Magn Reson Med ; 79(1): 554-560, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28303611

RESUMO

PURPOSE: Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. METHOD: The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. RESULTS: High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). CONCLUSION: Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Circulação Coronária , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Isquemia Miocárdica/diagnóstico por imagem , Algoritmos , Velocidade do Fluxo Sanguíneo , Cardiomiopatias/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Reconhecimento Automatizado de Padrão
2.
J Magn Reson Imaging ; 47(4): 1043-1053, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28766919

RESUMO

PURPOSE: To assess right ventricular (RV) turbulent kinetic energy (TKE) in patients with repaired Tetralogy of Fallot (rToF) and a spectrum of pulmonary regurgitation (PR), as well as to investigate the relationship between these 4D flow markers and RV remodeling. MATERIALS AND METHODS: Seventeen patients with rToF and 10 healthy controls were included in the study. Patients were divided into two groups based on PR fraction: one lower PR fraction group (≤11%) and one higher PR fraction group (>11%). Field strength/sequences: 3D cine phase contrast (4D flow), 2D cine phase contrast (2D flow), and balanced steady-state free precession (bSSFP) at 1.5T. ASSESSMENT: The RV volume was segmented in the morphologic short-axis images and TKE parameters were computed inside the segmented RV volume throughout diastole. Statistical tests: One-way analysis of variance with Bonferroni post-hoc test; unpaired t-test; Pearson correlation coefficients; simple and stepwise multiple regression models; intraclass correlation coefficient (ICC). RESULTS: The higher PR fraction group had more remodeled RVs (140 ± 25 vs. 107 ± 22 [lower PR fraction, P < 0.01] and 93 ± 15 ml/m2 [healthy, P < 0.001] for RV end-diastolic volume index [RVEDVI]) and higher TKE values (5.95 ± 3.15 vs. 2.23 ± 0.81 [lower PR fraction, P < 0.01] and 1.91 ± 0.78 mJ [healthy, P < 0.001] for Peak Total RV TKE). Multiple regression analysis between RVEDVI and 4D/2D flow parameters showed that Peak Total RV TKE was the strongest predictor of RVEDVI (R2 = 0.47, P = 0.002). CONCLUSION: The 4D flow-specific TKE markers showed a slightly stronger association with RV remodeling than conventional 2D flow PR parameters. These results suggest novel hemodynamic aspects of PR in the development of late complications after ToF repair. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1043-1053.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Pulmonar/complicações , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/complicações , Disfunção Ventricular Direita/complicações , Disfunção Ventricular Direita/diagnóstico por imagem , Adulto , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento Tridimensional/métodos , Masculino , Estudos Prospectivos , Insuficiência da Valva Pulmonar/fisiopatologia , Risco , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Direita/fisiopatologia
3.
J Magn Reson Imaging ; 43(3): 558-65, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26213253

RESUMO

PURPOSE: To investigate whether 4D flow magnetic resonance imaging (MRI) can detect subtle right ventricular (RV) dysfunction in primary left ventricular (LV) disease. MATERIALS AND METHODS: 4D flow and morphological 3T MRI data were acquired in 22 patients with mild ischemic heart disease who were stratified into two groups based on LV end-diastolic volume index (EDVI): lower-LVEDVI and higher-LVEDVI, as well as in 11 healthy controls. The RV volume was segmented at end-diastole (ED) and end-systole (ES). Pathlines were emitted from the ED volume and traced forwards and backwards in time to ES. The blood volume was separated into flow components. The Direct Flow (DF) component was defined as RV inflow passing directly to outflow. The kinetic energy (KE) of the DF component was calculated. Echocardiographic conventional RV indices were also assessed. RESULTS: The higher-LVEDVI group had larger LVEDVI and lower LV ejection fraction (98 ± 32 ml/m(2) ; 48 ± 13%) compared to the healthy (67 ± 12, P = 0.002; 64 ± 7, P < 0.001) and lower-LVEDI groups (62 ± 10; 68 ± 7, both P < 0.001). The RV 4D flow-specific measures "DF/EDV volume-ratio" and "DF/EDV KE-ratio at ED" were lower in the higher-LVEDVI group (38 ± 5%; 52 ± 6%) compared to the healthy (44 ± 6; 65 ± 7, P = 0.018 and P < 0.001) and lower-LVEDVI groups (44 ± 6; 64 ± 7, P = 0.011 and P < 0.001). There was no difference in any of the conventional MRI and echocardiographic RV indices between the three groups. CONCLUSION: We found that in primary LV disease mild impairment of RV function can be detected by 4D flow-specific measures, but not by the conventional MRI and echocardiographic indices.


Assuntos
Ventrículos do Coração/fisiopatologia , Imageamento por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Idoso , Algoritmos , Diástole , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Cinética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Projetos Piloto , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita
4.
Am J Physiol Heart Circ Physiol ; 301(6): H2344-50, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21926347

RESUMO

Right ventricular (RV) function is a powerful prognostic indicator in many forms of heart disease, but its assessment remains challenging and inexact. RV dysfunction may alter the normal patterns of RV blood flow, but those patterns have been incompletely characterized. We hypothesized that, based on anatomic differences, the proportions and energetics of RV flow components would differ from those identified in the left ventricle (LV) and that the portion of the RV inflow passing directly to outflow (Direct Flow) would be prepared for effective systolic ejection as a result of preserved kinetic energy (KE) compared with other RV flow components. Three-dimensional, time-resolved phase-contrast velocity, and balanced steady-state free-precession morphological data were acquired in 10 healthy subjects using MRI. A previously validated method was used to separate the RV and LV end-diastolic volumes into four flow components and measure their volume and KE over the cardiac cycle. The RV Direct Flow: 1) followed a smoothly curving route that did not extend into the apical region of the ventricle; 2) had a larger volume and possessed a larger presystolic KE (0.4 ± 0.3 mJ) than the other flow components (P < 0.001 and P < 0.01, respectively); and 3) represented a larger part of the end-diastolic blood volume compared with the LV Direct Flow (P < 0.01). These findings suggest that diastolic flow patterns distinct to the normal RV create favorable conditions for ensuing systolic ejection of the Direct Flow component. These flow-specific aspects of RV diastolic-systolic coupling provide novel perspectives on RV physiology and may add to the understanding of RV pathophysiology.


Assuntos
Ventrículos do Coração/anatomia & histologia , Hemodinâmica , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Adulto , Fenômenos Biomecânicos , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Volume Sistólico , Fatores de Tempo , Função Ventricular Esquerda , Adulto Jovem
5.
PLoS One ; 11(8): e0161391, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27532640

RESUMO

AIMS: 4D flow magnetic resonance imaging (MRI) allows quantitative assessment of left ventricular (LV) function according to characteristics of the dynamic flow in the chamber. Marked abnormalities in flow components' volume and kinetic energy (KE) have previously been demonstrated in moderately dilated and depressed LV's compared to healthy subjects. We hypothesized that these 4D flow-based measures would detect even subtle LV dysfunction and remodeling. METHODS AND RESULTS: We acquired 4D flow and morphological MRI data from 26 patients with chronic ischemic heart disease with New York Heart Association (NYHA) class I and II and with no to mild LV systolic dysfunction and remodeling, and from 10 healthy controls. A previously validated method was used to separate the LV end-diastolic volume (LVEDV) into functional components: direct flow, which passes directly to ejection, and non-ejecting flow, which remains in the LV for at least 1 cycle. The direct flow and non-ejecting flow proportions of end-diastolic volume and KE were assessed. The proportions of direct flow volume and KE fell with increasing LVEDV-index (LVEDVI) and LVESV-index (LVESVI) (direct flow volume r = -0.64 and r = -0.74, both P<0.001; direct flow KE r = -0.48, P = 0.013, and r = -0.56, P = 0.003). The proportions of non-ejecting flow volume and KE rose with increasing LVEDVI and LVESVI (non-ejecting flow volume: r = 0.67 and r = 0.76, both P<0.001; non-ejecting flow KE: r = 0.53, P = 0.005 and r = 0.52, P = 0.006). The proportion of direct flow volume correlated moderately to LVEF (r = 0.68, P < 0.001) and was higher in a sub-group of patients with LVEDVI >74 ml/m2 compared to patients with LVEDVI <74 ml/m2 and controls (both P<0.05). CONCLUSION: Direct flow volume and KE proportions diminish with increased LV volumes, while non-ejecting flow proportions increase. A decrease in direct flow volume and KE at end-diastole proposes that alterations in these novel 4D flow-specific markers may detect LV dysfunction even in subtle or subclinical LV remodeling.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ventrículos do Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Idoso , Diástole/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico/fisiologia , Sístole/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA