RESUMO
BACKGROUND: Exercise capacity is related to mortality and morbidity in heart failure (HF) patients. Determinants of exercise capacity in transthyretin cardiac amyloidosis (ATTR-CA) have not been established. METHODS AND RESULTS: This single-center study retrospectively evaluated ATTR-CA patients and patients with non-amyloidosis HF with preserved/mildly reduced ejection fraction (HFpEF/HFmrEF) (n=32 and n=51, respectively). In the ATTR-CA group, the median age was 75.5 years (interquartile range [IQR] 71.3-78.8 years), 90.6% were male, and the median left ventricular (LV) ejection fraction was 53.5% (IQR 41.4-65.6%). Cardiopulmonary exercise tests revealed a median peak oxygen consumption and anaerobic threshold of 15.9 (IQR 11.6-17.4) and 10.6 (IQR 8.5-12.0] mL/min/kg, respectively, and ventilatory efficiency (minute ventilation/carbon dioxide production [VÌE/VÌCO2] slope) of 35.5 (IQR 32.0-42.5). Among exercise variables, VÌE/VÌCO2slope has the greatest prognostic value. Univariate analysis revealed a significant correlation between VÌE/VÌCO2slope and age, LV global longitudinal strain, tricuspid annular plain systolic excursion/pulmonary arterial systolic pressure (TAPSE/PASP) ratio, and mixed venous oxygen saturation. In multivariate analyses, the TAPSE/PASP ratio was an independent predictor of VÌE/VÌCO2slope (95% confidence interval -44.5, -10.8; P=0.0067). In non-amyloidosis HFpEF/HFmrEF patients, the TAPSE/PASP ratio was not independently correlated with VÌE/VÌCO2slope. CONCLUSIONS: Right ventricular-pulmonary artery coupling estimated by the TAPSE/PASP ratio determines exercise capacity in ATTR-CA patients. This highlights the importance of early therapeutic intervention against underappreciated right ventricular dysfunction associated with ATTR-CA.
RESUMO
The 87thAnnual Meeting of the Japanese Circulation Society (JCS2023) was held in March 2023 in Fukuoka, Japan, marking the first in-person gathering after the COVID-19 pandemic. With the theme of "New Challenge With Next Generation" the conference emphasized the development of future cardiovascular leaders and technologies such as artificial intelligence (AI). Notable sessions included the Mikamo Lecture on heart failure and the Mashimo Lecture on AI in medicine. Various hands-on sessions and participatory events were well received, promoting learning and networking. Post-event surveys showed high satisfaction among participants, with positive feedback on face-to-face interactions and the overall experience. JCS2023, attended by 17,852 participants, concluded successfully, marking a significant milestone in post-pandemic meetings, and advancing cardiovascular medicine.
Assuntos
Cardiologia , Sistema Cardiovascular , Humanos , Japão , Inteligência Artificial , PandemiasRESUMO
Collaboration between the implantation centers, management centers, and regional core hospitals is a key factor in securing long-term implantable ventricular assist device (VAD) management. In Kyushu, a management system for patients with implantable VADs has been established at the prefectural and regional levels. Presently, six implantable VAD implantation centers and seven management centers exists in the eight prefectures of Kyushu and Okinawa, with at least one specialized VAD centers in each prefecture. This collaborative management system allows patients with VADs to receive seamless treatment based on the same management concept wherever they live. In fact, approximately half of the present outpatients treated at our center reside outside the prefecture and are managed in collaboration with management centers and regional core hospitals. Among our patients, there were no significant differences in survival or rehospitalization-free rates between patients with VADs in and out of the prefecture, suggesting that the place of residence did not affect the outcome. With the increase in the number of patients with VADs and the diversification of patients, patient management has become more complex. Mutual collaboration between the implantation centers, management centers, and regional core hospitals, is essential to improve the quality of VAD management. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 85-88), with some modifications.
Assuntos
Coração Auxiliar , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/estatística & dados numéricos , Japão , Implantação de PróteseRESUMO
Although anemia is a common comorbidity that often coexists with heart failure (HF), its clinical impact in patients with advanced HF remains unclear. We investigated the impact of hemoglobin levels on clinical outcomes in patients with advanced HF listed for heart transplantation without intravenous inotropes or mechanical circulatory support.We retrospectively reviewed the clinical data of patients listed for heart transplantation at our institute who did not receive intravenous inotropes or mechanical circulatory support between 2011 and 2022. We divided the patients into those with hemoglobin levels lower or higher than the median value and compared the composite of all-cause death and HF hospitalization within 1 year from the listing date.We enrolled consecutive 38 HF patients (27 males, 49.1 ± 10.8 years old). The median hemoglobin value at the time of listing for heart transplantation was 12.9 g/dL, and 66.7% of the patients had iron deficiency. None of the patients in either group died within 1 year. The HF hospitalization-free survival rate was significantly lower in the lower hemoglobin group (40.9% versus 81.9% at 1 year, P = 0.020). Multivariate Cox proportional hazards model analysis showed that hemoglobin as a continuous variable was an independent predictor for HF hospitalization (odds ratio 0.70, 95% confidence interval 0.49-0.97, P = 0.030).Hemoglobin level at the time of listing for heart transplantation was a predictor of hospitalization in heart-transplant candidates without intravenous inotropes or mechanical circulatory support.
Assuntos
Insuficiência Cardíaca , Transplante de Coração , Hemoglobinas , Hospitalização , Humanos , Masculino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Hospitalização/estatística & dados numéricos , Hemoglobinas/metabolismo , Hemoglobinas/análise , Adulto , Listas de Espera/mortalidadeRESUMO
Isolated cardiac sarcoidosis (iCS) is increasingly recognized; however, its prognosis and the efficacy of immunosuppressive therapy remain undetermined. We aimed to compare the prognosis of iCS and systemic sarcoidosis including cardiac involvement (sCS) under immunosuppressive therapy.We retrospectively reviewed the clinical data of 42 patients with sCS and 30 patients with iCS diagnosed at Kyushu University Hospital from 2004 through 2022. We compared the characteristics and the rate of adverse cardiac events including cardiac death, fatal ventricular tachyarrhythmia, and heart failure hospitalization between the 2 groups. The median follow-up time was 1535 [interquartile range, 630-2555] days, without a significant difference between the groups. There were no significant differences in gender, NYHA class, or left ventricular ejection fraction. Immunosuppressive agents were administered in 86% of sCS and in 73% of iCS patients (P = 0.191). When analyzed only with patients receiving immunosuppressive therapy (sCS, n = 36; iCS, n = 21), the cardiac event-free survival was significantly lower in iCS than sCS (37% versus 79%, P = 0.002). Myocardial LGE content at the initial diagnosis was comparable in both groups. The disease activity was serially evaluated in 26 sCS and 16 iCS patients by quantitative measures of FDG-PET including cardiac metabolic volume and total lesion glycolysis, representing 3-dimensional distribution and intensity of inflammation in the entire heart. Although iCS patients had lower baseline disease activity than sCS patients, immunosuppressive therapy did not attenuate disease activity in iCS in contrast to sCS.iCS showed a poorer response to immunosuppressive therapy and a worse cardiac prognosis compared to sCS despite lower baseline disease activity.
Assuntos
Cardiomiopatias , Imunossupressores , Sarcoidose , Humanos , Masculino , Feminino , Sarcoidose/tratamento farmacológico , Sarcoidose/complicações , Pessoa de Meia-Idade , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/fisiopatologia , Estudos Retrospectivos , Imunossupressores/uso terapêutico , Idoso , Prognóstico , Adulto , Tomografia por Emissão de Pósitrons/métodos , Taquicardia Ventricular/tratamento farmacológicoRESUMO
PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.
RESUMO
BACKGROUND: The role of donor-derived cell-free DNA (dd-cfDNA) in screening for cardiac allograft vasculopathy (CAV) is unknown. We hypothesized that dd-cfDNA correlates with CAV, markers of inflammation, and angiogenesis in stable heart transplant (HT) recipients. METHODS: Sixty-five HT recipients ≥2 years post-transplant, without recent rejection, were stratified by high (≥0.12%) versus low levels (<0.12%) of dd-cfDNA. A targeted amplification, next-generation sequencing assay (AlloSure® ; CareDx, Inc.) was used to detect dd-cfDNA. Peripheral blood inflammatory and angiogenesis markers were assessed using a multiplex immunoassay system (Bioplex® ). RESULTS: Of 65 patients, 58 patients had a known CAV status and were included. Thirty had high levels of dd-cfDNA (≥0.12%), and 28 had low levels (<0.12%). CAV was present in 63% of patients with high dd-cfDNA vs. 35% with low dd-cfDNA (p = .047). Donor-specific antibodies were present in 25% of patients with high dd-cfDNA vs. 3.8% in those with low dd-cfDNA (p = .03). There were no differences in rejection episodes, inflammatory, or angiogenesis markers. Importantly, dd-cfDNA levels were not different when stratified by time post-transplant. CONCLUSIONS: Higher dd-cfDNA levels were associated with CAV in stable chronic HT recipients. Further studies are warranted to investigate a possible association between dd-cfDNA levels and CAV severity and whether dd-cfDNA can predict CAV progression.
Assuntos
Ácidos Nucleicos Livres , Transplante de Coração , Transplante de Rim , Aloenxertos , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/etiologia , Transplante de Coração/efeitos adversos , Humanos , Doadores de TecidosRESUMO
BACKGROUND: Capillary deposition of C4d is an important marker of antibody-mediated rejection (AMR) following heart transplantation (HT). There are two immunopathologic assay methods for detecting C4d: frozen-tissue immunofluorescence (IF) and paraffin immunohistochemistry (IHC). The clinical significance of discrepancy between the results of IF and IHC has not been understood. METHODS AND RESULTS: We reviewed 2187 biopsies from 142 HT recipients who had biopsies with assessment of both IF and IHC staining. Among them, 103 (73%) patients had negative IF and IHC C4d staining (Negative Group) and 32 (23%) patients had positive IF but negative IHC staining (Discordant Group). At the time of positive biopsy, 6 (19%) Discordant patients had graft dysfunction, compared to 5 (5%) Negative patients (p = .022). Cumulative incidence of cellular rejection at 1 year was comparable (31% vs. 29%, p = .46); however, cumulative incidence of AMR was significantly higher in the Discordant group (21% vs. 4%, p = .004). Overall 1-year survival was comparable (90% vs. 96%, p = .24); however, freedom from heart failure (HF) was significantly lower in the Discordant group (70% vs. 96%, p < .001). CONCLUSION: The Discordant group showed higher rates of graft dysfunction, AMR and HF admission than the Negative group.
Assuntos
Complemento C4b , Transplante de Coração , Biópsia , Imunofluorescência , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/etiologia , Humanos , Imuno-Histoquímica , Fragmentos de Peptídeos , Coloração e RotulagemRESUMO
Aortic insufficiency remains a difficult to treat and highly morbid condition even in the era of HeartMate 3 left ventricular assist devices (LVADs). The prognostic nature of the longitudinal progression of aortic insufficiency, however, remains unknown. We prospectively collected data on patients who received HeartMate 3 LVAD implantation, who had assessments of aortic insufficiency using a novel Doppler echocardiography obtained at outflow graft at three (baseline) and 6 months postimplant. Patients with moderate or greater aortic insufficiency at baseline were excluded. The risk of aortic insufficiency progression on 1-year death and readmission for heart failure was investigated. In total, 41 patients (median 51 years old and 29 males) were included. All patients had less than moderate aortic insufficiency at baseline. Of them, 22 patients had worsening aortic insufficiency for 3 months following baseline assessments, which was associated with a significantly higher risk of 1-year death or heart failure readmission rate (41% vs. 11%, P = .023) with a hazard ratio of 3.24 (95% confidence interval 1.02-18.5, P = .038) adjusted for device speed at baseline and destination therapy indication. In patients with HeartMate 3 LVADs, progressive aortic insufficiency may be associated with a higher risk of 1-year death or readmission for heart failure. Close monitoring of patients with baseline aortic insufficiency should be considered as a measure to risk-stratify those for future adverse events.
Assuntos
Insuficiência da Valva Aórtica/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Progressão da Doença , Ecocardiografia Doppler , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Complicações Pós-Operatórias/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Estudos Retrospectivos , Índices de Gravidade do Trauma , Resultado do Tratamento , Função Ventricular Esquerda/fisiologiaRESUMO
A 61-year-old woman suffered chest pain and was admitted to a nearby hospital emergency department. She was diagnosed with acute myocardial infarction probably due to thromboembolism in the left anterior descending coronary artery and aspiration thrombectomy was performed. Afterwards, she developed refractory heart failure with severe global left ventricular dysfunction and was transferred to our hospital. An 18F-FDG-PET/CT scan revealed abnormal 18F-FDG uptake in non-infarcted regions of the left ventricle. Non-caseating granulomas were detected by biopsy from a skin eruption. She was diagnosed with cardiac sarcoidosis. In cases of refractory heart failure which cannot be explained only by myocardial infarction, evaluation of other undiagnosed cardiomyopathies is important for optimal management.
Assuntos
Cardiomiopatias/complicações , Trombose Coronária/complicações , Insuficiência Cardíaca/etiologia , Infarto do Miocárdio/etiologia , Sarcoidose/complicações , Cardiomiopatias/diagnóstico , Trombose Coronária/diagnóstico , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sarcoidose/diagnósticoRESUMO
BACKGROUND: HVAD left ventricular assist device flow waveforms provides graphical real-time information linking device performance with invasive hemodynamics. Previous studies have demonstrated a good correlation between the slopes of the ventricular filling phase slope (VFPS) and directly measured pulmonary capillary wedge pressure (PCWP). We aimed to validate the utility of VFPS to estimate PCWP and predict clinical outcomes. METHODS: In this prospective blinded study, screenshots from the HVAD monitor and simultaneous invasive hemodynamic measurements were obtained. Each screenshot was digitized and the VFPS was calculated by 2 independent reviewers who were blinded to the hemodynamic results. The equation PCWPâ¯=â¯7.053 +1.365â¯×â¯(VFPS) was derived from a previously published dataset and the estimated PCWP was correlated to the actually measured PCWP. RESULTS: One hundred thirty-one sets of simultaneous measurements (VFPS and PCWP) were obtained from 27 HVAD patients (mean age 55 years, 47% male). A previously proposed cutoff of VFPS ≥5.8 L/min/s predicted PCWP ≥ 18 mmHg with 91.5% sensitivity and 95.2% specificity with the area under curve of 0.987. The estimated PCWP significantly correlated with measured PCWP (R2â¯=â¯0.65, P < .001) and showed acceptable agreement with measured PCWP. Patients with VFPS ≥ 5.8 L/min/s experienced significantly higher heart failure readmission rates than those without (0.24 vs 0.05 events/y, P < .001). CONCLUSIONS: VFPS of the HVAD flow waveform is a novel noninvasive parameter that can estimate PCWP.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Pressão Propulsora PulmonarRESUMO
BACKGROUND: Aortic insufficiency (AI) is associated with morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs), whereas its impact on the HeartMate 3 LVAD cohorts remains uninvestigated. We aimed to investigate the clinical impact of AI on patients with HeartMate 3 LVADs. METHODS AND RESULTS: Consecutive 61 patients (median age 54 years; 67% male) implanted with HeartMate 3 LVAD between 2015 and 2019 were enrolled and underwent echocardiography at 3 months after LVAD implantation. AI severity was quantified by the novel Doppler echocardiographic method obtained at the outflow cannula and the calculated regurgitation fraction of 30% or greater (moderate or greater) was defined as significant. At 3 months after implant, 12 patients (20%) had significant AI. They had a higher incidence of death or heart failure readmissions compared with those without significant AI during a 1-year observational period (70% vs 24%, Pâ¯=â¯.003) with an adjusted hazard ratio of 2.76 (95% confidence interval 1.03-7.88). CONCLUSIONS: In patients with HeartMate 3 LVAD support, significant AI remains both prevalent and a clinically significant downstream complication.
Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Pré-Escolar , Ecocardiografia , Ecocardiografia Doppler , Feminino , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Estudos RetrospectivosRESUMO
BACKGROUND: Characterization of right heart catheterization (RHC) waveforms provides diagnostic and clinical information in heart failure patients. We aimed to investigate the implication of RHC waveforms, specifically the y-descent, in patients with left ventricular assist device (LVAD). METHODS AND RESULTS: Patients underwent RHC and waveforms were quantified prior to and 6 months after LVAD implantation. The impact of a deep y-descent (>3 mmHg) on echocardiographic measures of right heart function and 1-year hemocompatibility-related adverse event rates were investigated. Eighty-nine patients (median 59 years old, 65 male) underwent RHC. RHC waveform showed unique changes following LVAD implantation, particularly an increase in the steepness of the y-descent. A post-LVAD deep y-descent was associated with reduced right ventricular function and enlarged right heart. Patients with post-LVAD deep y-descent had higher rates of gastrointestinal bleeding (0.866 vs 0.191 events/year) and stroke (0.199 vs 0 events/year) compared with those without (P< .05 for both). CONCLUSION: RHC waveforms characterized by deep y-descent on RHC waveform during LVAD support was associated with impaired right ventricular function and worse clinical outcomes.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Função Ventricular DireitaRESUMO
BACKGROUND: Continuous-flow left ventricular assist devices (LVADs) improve the hemodynamics of patients with advanced heart failure. However, the longitudinal trajectories of hemodynamics in patients after LVAD implantation remain unknown. The aim of this study was to investigate the trends of hemodynamic parameters following LVAD implantation. METHODS AND RESULTS: We retrospectively reviewed patients who underwent LVAD implantation between April 2014 and August 2018. We collected hemodynamic parameters from right heart catheterizations. Of 199 consecutive patients, we enrolled 150 patients who had both pre- and postimplant right heart catheterizations. They had 3 (2, 4) postimplant right heart catheterizations during a follow-up of 2.3 (1.3, 3.1) years. The mean age was 57 ± 13 years, and 102 patients (68%) were male. Following LVAD implantation, pulmonary arterial pressure and pulmonary capillary wedge pressure decreased, and cardiac index increased significantly, then remained unchanged throughout follow-up. Right atrial pressure decreased initially and then gradually increased to preimplant values. The pulmonary artery pulsatility index decreased initially and returned to preimplant values, then progressively decreased over longer follow-up. Subgroup analysis showed significant differences in the trajectories of the pulmonary artery pulsatility index based on gender. CONCLUSIONS: Despite improvement in left-side filling pressures and cardiac index following LVAD implantation, right atrial pressure increased and the pulmonary artery pulsatility index decreased over time, suggesting progressive right ventricular dysfunction.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Insuficiência Cardíaca/cirurgia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
Hypogammaglobulinemia (HGG) can occur following solid organ transplantation. However, there are limited data describing the prevalence, risk factors, and clinical outcomes associated with HGG following heart transplantation. We retrospectively reviewed data of 132 patients who had undergone heart transplantation at our institution between April 2014 and December 2018. We classified patients into three groups based on the lowest serum IgG level post-transplant: normal (≥700 mg/dL), mild HGG (≥450 and <700 mg/dL), and severe HGG (<450 mg/dL). We compared clinical outcomes from the date of the lowest IgG level. Mean age was 57 (47, 64) years, and 94 (71%) patients were male. Prevalence of severe HGG was the highest (27%) at 3-6 months following heart transplantation and then decreased to 5% after 1 year. Multivariate analysis showed that older age and Caucasian race were independent risk factors for HGG. Overall survival was comparable between the groups; however, survival free of infection was 73%, 60%, and 45% at 1 year in the normal, mild HGG, and severe HGG groups, respectively (P = .013). In conclusion, there is a high prevalence of HGG in the early post-heart transplant period that decreases over time. HGG is associated with an increased incidence of infection.
Assuntos
Agamaglobulinemia , Transplante de Coração , Agamaglobulinemia/epidemiologia , Agamaglobulinemia/etiologia , Feminino , Transplante de Coração/efeitos adversos , Humanos , Imunoglobulina G , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de RiscoRESUMO
BACKGROUND: An inverse relationship exists between hospital case volume and mortality in patients with heart failure (HF). However, hospital performance factors associated with mortality in HF patients have not been examined. We aimed to identify these using exploratory factor analysis and assess the relationship between these factors and 7-day, 30-day, and in-hospital mortality among HF patients in Japan.MethodsâandâResults:We analyzed the records of 198,861 patients admitted to 683 certified hospitals of the Japanese Circulation Society between 2012 and 2014. Records were obtained from the nationwide database of the Japanese Registry Of All cardiac and vascular Diseases-Diagnostic Procedure Combination (JROAD-DPC). Using exploratory factor analysis, 90 hospital survey items were grouped into 5 factors, according to their collinearity: "Interventional cardiology", "Cardiovascular surgery", "Pediatric cardiology", "Electrophysiology" and "Cardiac rehabilitation". Multivariable logistic regression analysis was performed to determine the association between these factors and mortality. The 30-day mortality was 8.0%. Multivariable logistic regression analysis showed the "Pediatric cardiology" (odds ratio (OR) 0.677, 95% confidence interval [CI]: 0.628-0.729, P<0.0001), "Electrophysiology" (OR 0.876, 95% CI: 0.832-0.923, P<0.0001), and "Cardiac rehabilitation" (OR 0.832, 95% CI: 0.792-0.873, P<0.0001) factors were associated with lower mortality. In contrast, "Interventional cardiology" (OR 1.167, 95% CI: 1.070-1.272, P<0.0001) was associated with higher mortality. CONCLUSIONS: Hospital factors, including various cardiovascular therapeutic practices, may be associated with the early death of HF patients.
Assuntos
Insuficiência Cardíaca/mortalidade , Mortalidade Hospitalar , Hospitalização , Demandas Administrativas em Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Análise por Conglomerados , Bases de Dados Factuais , Análise Fatorial , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Japão/epidemiologia , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Cannula position in HeartMate II and HeartWare left ventricular assist devices (LVADs) is associated with clinical outcome. This study aimed to investigate the clinical implication of the device positioning in HeartMate 3 LVAD cohort. Consecutive patients who underwent HeartMate 3 LVAD implantation were followed for one year from index discharge. At index discharge, chest X-ray parameters were measured: (a) cannula coronal angle, (b) height of pump bottom, (c) cannula sagittal angle, and (d) cannula lumen area. The association of each measurement of cannula position with one-year clinical outcomes was investigated. Sixty-four HeartMate 3 LVAD patients (58 years old, 64% male) were enrolled. In the multivariable Cox regression model, the cannula coronal angle was a significant predictor of death or heart failure readmission (hazard ratio 1.27 [1.01-1.60], P = .045). Patients with a cannula coronal angle ≤28° had lower central venous pressure (P = .030), lower pulmonary capillary wedge pressure (P = .027), and smaller left ventricular size (P = .019) compared to those with the angle >28°. Right ventricular size and parameters of right ventricular function were also better in the narrow angle group, as was one-year cumulative incidence of death or heart failure readmission (10% vs. 50%, P = .008). Narrow cannula coronal angle in patients with HeartMate 3 LVADs was associated with improved cardiac unloading and lower incidence of death or heart failure readmission. Larger studies to confirm the implication of optimal device positioning are warranted.
Assuntos
Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Implantação de Prótese/métodos , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente/estatística & dados numéricos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Função Ventricular Esquerda/fisiologiaRESUMO
An intra-aortic balloon pump (IABP) is a device of internal counterpulsation. Inflation of the balloon in diastole results in a potential increase in coronary blood flow and an improvement in systemic perfusion, and deflation at the end of diastole reduces left ventricular afterload, although the hemodynamic effects are relatively small. With its favorable safety profile due to fewer adverse events, IABP has been used for more than 5 decades as the most common mechanical circulatory support device for cardiogenic shock. Recently, however, other short-term devices have become available, and the position of IABP for cardiogenic shock is rapidly changing. Meanwhile, novel improvements in knowledge and technology are pushing the boundaries of this device. In this review, we summarize the basic physiology and current evidence of this device and then discuss the outlook and implications of IABP in the future.
Assuntos
Balão Intra-Aórtico/tendências , Choque Cardiogênico/terapia , HumanosRESUMO
AIM: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. METHODS AND RESULTS: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (Pâ¯=â¯0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; Pâ¯=â¯0.009), due mostly to higher tier I (mild HRAE; Pâ¯=â¯0.034) and tier IIIB scores (severe HRAE; Pâ¯=â¯0.011). CONCLUSION: Significant AI, as assessed by Doppler echocardiographic parameters, was associated with HRAE during LVAD support.