Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Toxicol In Vitro ; 20(8): 1370-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16890396

RESUMO

The aim of this study was to evaluate the cytotoxicity of cubic boron nitride (cBN), a component of surgical cutting tools. The small quantities of cBN that typically remain on implants as a result of the manufacturing process may act as abrasives, injuring tissues surrounding the implant. To determine how cBN affects cells, we treated human neuroblastoma cells (NB-1) and human articular chondrocytes (nHAC-kn) with different concentrations of cBN powder and assessed cell growth and cell survival using the methyl-thiazol-tetrazolium (MTT) assay and a fluorescence probe assay. We also assessed the effects of tungsten carbide (WC) and cobalt (Co), two common components of joint implants, on cell growth and cell survival. Both cBN and WC moderately inhibited NB-1 and nHAC-kn cell growth. However, cBN and WC did not affect cell survival, even at high concentrations (40 microg/ml). By contrast, Co affected cell survival, inducing cell death in both cell types at increasing concentrations. These results suggest that cBN may be less toxic than WC alloys containing Co.


Assuntos
Materiais Biocompatíveis/toxicidade , Compostos de Boro/toxicidade , Células 3T3 , Animais , Neoplasias Encefálicas/tratamento farmacológico , Neoplasias Encefálicas/patologia , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Condrócitos/efeitos dos fármacos , Cobalto/toxicidade , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Microscopia Eletrônica de Varredura , Neuroblastoma/tratamento farmacológico , Neuroblastoma/patologia , Tamanho da Partícula , Pós
2.
Biomed Chromatogr ; 18(6): 396-9, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15273980

RESUMO

A capillary electrochromatographic (CEC) method was applied to the simultaneous separation of barbiturates (barbital, phenobarbital, secobarbital and thiopental) and benzodiazepines (nitrazepam, diazepam and triazolam). The separation was performed in a 75 microm i.d. capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effects of buffer pH and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 45% methanol provided the baseline separation of seven toxic drugs in less than 9 min. In CEC with NAIP, the benzodiazepines were separated by the combination of hydrophobic and pi-pi interactions, whereas the separation of the barbiturates was based on the hydrophobic interaction.


Assuntos
Barbitúricos/isolamento & purificação , Benzodiazepinas/isolamento & purificação , Cromatografia Líquida/métodos , Compostos Organometálicos/química , Soluções Tampão , Concentração de Íons de Hidrogênio , Solventes
3.
Electrophoresis ; 25(4-5): 594-9, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14981686

RESUMO

A capillary electrochromatographic method was developed for the separation of barbiturates. The separation was optimized in a 75 microm ID capillary, packed with 3-(1,8-naphthalimido)propyl-modified silyl silica gel (NAIP), studying the effect of buffer pH, buffer concentration, and mobile phase composition. Using an applied voltage of 20 kV and the short-end injection method (9 cm capillary effective length), the mobile phase of 1.0 mM citrate buffer (pH 5.0) containing 40% methanol provided the baseline separation of barbital, phenobarbital, secobarbital, and thiopental (internal standard) in less than 4.5 min. The method was successfully applied to the analysis of barbiturates in human serum. Under the optimal conditions, good repeatability and linearity were obtained in the range of 2.90-43.29 microg/mL for barbital, phenobarbital, and secobarbital.


Assuntos
Barbitúricos/sangue , Cromatografia Capilar Eletrocinética Micelar/métodos , Barbitúricos/isolamento & purificação , Soluções Tampão , Humanos , Concentração de Íons de Hidrogênio , Metanol/química , Reprodutibilidade dos Testes , Dióxido de Silício/química , Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA