Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378816

RESUMO

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Impedância Elétrica , Resultado do Tratamento , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Recidiva
2.
Circ J ; 87(7): 939-946, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-36464278

RESUMO

BACKGROUND: A recent randomized trial demonstrated that catheter ablation for atrial fibrillation (AF) in patients with heart failure with reduced ejection fraction (EF) is associated with a reduction in death or heart failure. However, the effect of catheter ablation for AF in patients with heart failure with mid-range or preserved EF is unclear.Methods and Results: We screened 899 AF patients (72.4% male, mean age 68.4 years) with heart failure and left ventricular EF ≥40% from 2 Japanese multicenter AF registries: the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) as the ablation group (525 patients who underwent ablation) and the Hokuriku-Plus AF Registry as the medical therapy group (374 patients who did not undergo ablation). Propensity score matching was performed in these 2 registries to yield 106 matched patient pairs. The primary endpoint was a composite of cardiovascular death and hospitalization for heart failure. At 24.6 months, the ablation group had a significantly lower incidence of the primary endpoint (hazard ratio 0.32; 95% confidence interval 0.13-0.70; P=0.004) than the medical therapy group. CONCLUSIONS: Compared with medical therapy, catheter ablation for AF in patients with heart failure and mid-range or preserved EF was associated with a significantly lower incidence of cardiovascular death or hospitalization for heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Feminino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
3.
J Cardiovasc Electrophysiol ; 33(6): 1160-1166, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35488745

RESUMO

INTRODUCTION: Direct comparison studies about the incidence of esophagogastric complications between radiofrequency (RF) and cryoballoon (CB) catheter ablation (CA) for atrial fibrillation (AF) have been scarce. We sought to elucidate the relationship between the pulmonary vein isolation (PVI) modalities and esophagogastric complications. METHODS: The study population consisted of 254 patients who underwent CA for AF from November 2017 to October 2018. Finally, 160 patients were enrolled and divided into the RF and CB groups. Esophageal ulcers, gastric hypomotility, and exfoliative esophagitis detected by esophagogastroduodenoscopy were defined as esophagogastric complications in this study. RESULTS: The median age was 68 years old, with 34% being females. Esophagogastric complications were observed in 42.5% of patients who underwent CA. According to the detailed esophagogastric complications, the RF group had a higher prevalence of esophageal ulcers than the CB group (19% vs. 0%, p < .0001). There was no significant difference between the two groups regarding gastric hypomotility and exfoliative esophagitis (18% vs. 28%; p = .15 and 16% vs. 21%; p = .42, respectively). CONCLUSION: Asymptomatic esophagogastric complications were common in CA for AF. The incidence of esophageal ulcers was higher in the RF group than in the CB group, whereas the other esophagogastric complications did not significantly differ.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Esofagite , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Esofagite/etiologia , Esofagite/cirurgia , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento , Úlcera/etiologia , Úlcera/cirurgia
4.
J Cardiovasc Electrophysiol ; 33(3): 380-388, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35018687

RESUMO

BACKGROUND: Local impedance (LI) can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). However, data on the effects of catheter contact angle on LI parameters are scarce. This study aimed to evaluate the influence of catheter contact angle on LI changes and lesion size with two different LI-sensing catheters in a porcine experimental study. METHODS: Lesions were created by the INTELLANAV MiFi™ OI (MiFi) and the INTELLANAV STABLEPOINT™ (STABLEPOINT). RFCA was performed with 30 W and a duration of 30 s. The contact force (CF) (0, 5, 10, 20, and 30 g) and catheter contact angle (30°, 45°, and 90°) were changed in each set (n = 8 each). The LI rise, LI drop, and lesion size were evaluated. RESULTS: The LI rise increased as CF increased. There was no angular dependence with the LI rise under all CFs in the MiFi. On the other hand, the LI rise at 90° was lower than at 30° under 5 and 10 g of CF in STABLEPOINT. The LI drop increased as CF increased. Regarding the difference in catheter contact angles, the LI drop at 90° was lower than that at 30° for both catheters. The maximum lesion widths and surface widths were smaller at 90° than at 30°, whereas there were no differences in lesion depths. CONCLUSION: The LI drop and lesion widths at 90° were significantly smaller than those at 30°, although the lesion depths were not different among the 3 angles for the MiFi and STABLEPOINT.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/efeitos adversos , Catéteres , Impedância Elétrica , Desenho de Equipamento , Suínos
5.
Circ J ; 86(2): 233-242, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34219078

RESUMO

BACKGROUND: It is unclear whether there are differences in the clinical factors between atrial fibrillation (AF) recurrence and adverse clinical events (AEs), including stroke/transient ischemic attack (TIA), major bleeding, and death, after AF ablation.Methods and Results:We examined the data from a retrospective multicenter Japanese registry conducted at 24 cardiovascular centers between 2011 and 2017. Of the 3,451 patients (74.1% men; 63.3±10.3 years) who underwent AF ablation, 1,046 (30.3%) had AF recurrence and 224 (6.5%) suffered AEs (51 strokes/TIAs, 71 major bleeding events, and 36 deaths) over a median follow-up of 20.7 months. After multivariate adjustment, female sex, persistent and long-lasting persistent AF (vs. paroxysmal AF), and stepwise increased left atrial diameter (LAd) quartiles were significantly associated with post-ablation recurrences. A multivariate analysis revealed that an age ≥75 years (vs. <65 years), body weight <50 kg, diabetes, vascular disease, left ventricular (LV) ejection fraction <40% (vs. ≥50%), Lad ≥44 mm (vs. <36 mm), and creatinine clearance <50 mL/min were independently associated with AE incidences, but not with recurrences. CONCLUSIONS: This study disclosed different determinants of post-ablation recurrence and AEs. Female sex, persistent AF, and enlarged LAd were determinants of post-ablation recurrence, whereas an old age, comorbidities, and LV and renal dysfunction rather than post-ablation recurrence were AEs determinants. These findings will help determine ablation indications and post-ablation management.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Hemorragia/etiologia , Humanos , Ataque Isquêmico Transitório/etiologia , Masculino , Recidiva , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
6.
Heart Vessels ; 37(6): 1027-1033, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34799789

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with an increased risk of heart failure (HF), stroke, and death. Although fibrillation cycle length (FCL) is used as a surrogate for atrial refractoriness, its impact on outcomes remains unclear. This study aimed to identify predictors of cardiovascular events, including FCL, in patients with long-standing persistent AF. METHODS: The study included 190 consecutive patients with long-standing persistent AF (mean age 74 years, 74% male). Patients with valvular AF or hemodialysis-dependent end-stage renal disease and those on anti-arrhythmic drugs were excluded. The primary composite outcome was occurrence of cardiovascular events (myocardial infarction, HF), cerebrovascular events (stroke, transient ischemic attack), and all-cause death. FCL was calculated by fast Fourier transformation analysis of fibrillation waves in the surface electrocardiogram. RESULTS: Over a median follow-up of 2.6 years, the primary outcome occurred in 31 patients (cardiovascular events, n = 18; cerebrovascular events, n = 8; all-cause death, n = 5). In multivariate analysis, longer FCL and history of HF were independent predictors of these outcomes. In a Cox proportional hazards model adjusted for age, sex, and history of HF, patients with an FCL > 160 ms (cut-off determined by receiver-operating characteristic curve analysis) were at increased risk of the outcome (hazard ratio 12.9; 95% confidence interval 4.99-44.10; p < 0.001). CONCLUSIONS: FCL was independently associated with cardiovascular outcomes in patients with long-standing persistent AF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia , Feminino , Átrios do Coração , Insuficiência Cardíaca/complicações , Humanos , Masculino , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
7.
Heart Vessels ; 37(4): 628-637, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34613425

RESUMO

The recurrence of atrial fibrillation (AF) after catheter ablation (CA) is still an unsolved issue. Although structural remodeling is relatively well defined, the method to assess electrical remodeling of the atrium is not well established. In this study, we evaluated the relationship between atrial conduction properties and recurrence after CA for AF. One hundred six consecutive patients (66 ± 11 years old, male: 68%) who underwent CA for AF with a CARTO system from July 2016 to July 2019 were enrolled in this study. An activation map of both atria was constructed to precisely evaluate the total conduction time, distance, and conduction velocity between the earliest and latest activation sites during sinus rhythm. All parameters were compared between the patients with or without AF recurrence. Of the patients, 27 had an AF recurrence (Rec group). The left atrial (LA) conduction velocity was significantly slower in the Rec group than in the non-Rec group (101.2 ± 17.9 vs. 116.9 ± 18.0 cm/s, P < 0.01). Likewise, the right atrial (RA) conduction velocity was significantly slower in the Rec group than in the non-Rec group (81.1 ± 17.5 vs. 103.6 ± 25.4 cm/s, P < 0.01). A multivariate logistic analysis demonstrated that the LA and RA conduction velocities were independent predictors of AF recurrence, with adjusted odds ratios of 0.95 (95% confidential interval: 0.91-0.98, P < 0.01) and 0.94 (0.89-0.98, P < 0.01), respectively. In conclusion, slower conduction velocity of the atrium was associated with AF recurrence after pulmonary vein isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
Heart Vessels ; 37(2): 327-336, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524497

RESUMO

The impact of catheter ablation for atrial fibrillation (AF) on cardiovascular events and mortality is controversial. We investigated the impact of sinus rhythm maintenance on major adverse cardiac and cerebrovascular events after AF ablation from a Japanese multicenter cohort of AF ablation. We investigated 3326 consecutive patients (25.8% female, mean age 63.3 ± 10.3 years) who underwent catheter ablation for AF from the atrial fibrillation registry to follow the long-term outcomes and use of anti coagulants after ablation (AF frontier ablation registry). The primary endpoint was a composite of stroke, transient ischemic attack, cardiovascular events, and all-cause death. During a mean follow-up of 24.0 months, 2339 (70.3%) patients were free from AF after catheter ablation, and the primary composite endpoint occurred in 144 (4.3%) patients. The AF nonrecurrence group had a significantly lower incidence of the primary endpoint (1.8 per 100 person-years) compared with the AF recurrence group (3.0 per 100 person-years, p = 0.003). The multivariate analysis revealed that freedom from AF (hazard ratio 0.61, 95% confidence interval 0.44-0.86, p = 0.005) was independently associated with the incidence of the composite event. In the multicenter cohort of AF ablation, sinus rhythm maintenance after catheter ablation was independently associated with lower rates of major adverse cardiac and cerebrovascular events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 32(12): 3187-3194, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34559441

RESUMO

BACKGROUND: Local impedance (LI) has emerged as a new technology that informs on electrical catheter-tissue coupling during radiofrequency (RF) ablation. Recently, IntellaNav StablePoint, a novel LI-enabled catheter that equips contact force (CF) sensing, has been introduced. Although StablePoint and its predecessor IntellaNav MiFi OI share the common technology that reports LI, distinct mechanics for LI sensing between the two products raise a concern that the LI-RF lesion formation relationship may differ. METHODS: In an ex vivo swine cardiac tissue model, we investigated the initial level and range of a reduction in LI during a 60-s RF ablation and the resultant lesion characteristics at nine combinations of three energy power (30, 40, and 50 W) and CF (10, 30, and 50 g) steps. Correlations and interactions between CF, LI, wattage, and formed lesions were analyzed. Incidence of achieving LI drop plateau and that of a steam pop were also determined. RESULTS: Positive correlations existed between CF and initial LI, CF and absolute/relative LI drop, CF and lesion volume, and LI drop and lesion volume. At the same LI drop, wattage-dependent gain in lesion volume was observed. Steam pops occurred in all CF steps and the prevalence was highest at 50 W. LI drop predicted a steam pop with a cutoff value at 89Ω. CONCLUSION: In StablePoint, wattage crucially affects LI drop and lesion volume. Because 30 W ablation may by underpowered for intramural lesion formation and 50 W often resulted in a steam pop, 40 W appears to achieve the balance between the safety and efficacy.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/métodos , Catéteres , Impedância Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Vapor , Suínos
10.
J Cardiovasc Electrophysiol ; 32(8): 2069-2076, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34185348

RESUMO

BACKGROUND: The local impedance (LI) reflects the electrical catheter-tissue coupling and correlates with the local tissue temperature. However, there have been few clinical studies showing the recommended method for LI monitoring catheters. This study aimed to investigate the optimal ablation setting for this catheter in an in vitro experimental model. METHODS: LI monitoring catheters were used in an excised swine heart experimental model. The tissue contact force (CF) was directly monitored from an external weight scale. Radiofrequency ablation was performed with a combination of various energy power settings (30, 40, and 50 W), and various CFs (10, 30, and 50 g) for 60 s. The correlation between the LI-related indexes, power, and CF with the lesion formation was statistically analyzed. RESULTS: A positive correlation between the LI or lesion formation and CF was observed under all powers. Although the LI drop always correlated with the maximum lesion depth, lesion diameter, and lesion volume, the coefficient of the correlation value was lower under a high CF (lesion depth, diameter, and volume; 10 g, r = 0.8064, r = 0.8389, r = 0.8477; 30 g, r = 0.7590, r = 0.8063, r = 0.8060; 50 g r = 0.5555, r = 0.5701, and r = 0.5678, respectively). Steam pops occurred only under a 50 W ablation and the LI drop cutoff value for steam pops was 46 Ω. CONCLUSION: The same LI drop did not always lead to the same lesion size when the CF differed. Monitoring the LI and not exceeding 46 Ω would be useful for a safe ablation.


Assuntos
Ablação por Cateter , Animais , Catéteres , Impedância Elétrica , Modelos Teóricos , Vapor , Suínos
11.
Circ J ; 85(3): 300-308, 2021 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-33191390

RESUMO

BACKGROUND: We assessed the relationship between day-to-day variation of the early repolarization (ER) pattern and ventricular tachyarrhythmia (VTA) events in Brugada syndrome (BrS) patients because the clinical implications are unclear.Methods and Results:This retrospective study consisted of 41 patients with BrS who underwent implantable cardioverter-defibrillator (ICD) implantation. BrS was diagnosed by a spontaneous or drug-induced type 1 ECG without structural heart disease. Day-to-day variation of the ER pattern was defined as temporal change in the J-point (≥0.1 mV) on ECG. VTA events were detected via ICD interrogation: 15 patients experienced VTA events during 124±62 months' observation. Day-to-day variation of the ER pattern was positive in 7 patients (17%). In the multivariate Cox proportional hazards model, day-to-day variation of a positive ER pattern (hazard ratio [HR]: 3.475, 95% confidence interval [CI]: 1.105-10.414, P=0.034) and documented history of VTA (HR: 4.802, 95% CI: 1.547-17.995, P=0.006) were independent predictors of VTA events. In patients with electrical storm (ES: n=9), day-to-day variation of the ER pattern was positive in 5 patients (56%). ES events were more frequently observed in patients with a positive day-to-day variation of ER pattern than in those without (P<0.05). CONCLUSIONS: The incidence of day-to-day variation of the ER pattern was higher in patients with arrhythmic events of VTA and/or ES among BrS patients with ICD.


Assuntos
Síndrome de Brugada , Desfibriladores Implantáveis , Taquicardia Ventricular , Síndrome de Brugada/complicações , Morte Súbita Cardíaca , Eletrocardiografia , Humanos , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia
12.
Heart Vessels ; 36(4): 549-560, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33236221

RESUMO

Whether ablation for atrial fibrillation (AF) is, in terms of clinical outcomes, beneficial for Japanese patients has not been clarified. Drawing data from 2 Japanese AF registries (AF Frontier Ablation Registry and SAKURA AF Registry), we compared the incidence of clinically relevant events (CREs), including stroke/transient ischemic attack (TIA), major bleeding, cardiovascular events, and death, between patients who underwent ablation (n = 3451) and those who did not (n = 2930). We also compared propensity-score matched patients (n = 1414 in each group). In propensity-scored patients who underwent ablation and those who did not, mean follow-up times were 27.2 and 35.8 months, respectively. Annualized rates for stroke/TIA (1.04 vs. 1.06%), major bleeding (1.44 vs. 1.20%), cardiovascular events (2.15 vs. 2.49%) were similar (P = 0.96, 0.39, and 0.35, respectively), but annualized death rates were lower in the ablation group than in the non-ablation group (0.75 vs.1.28%, P = 0.028). After multivariate adjustment, the risk of CREs was statistically equivalent between the ablation and non-ablation groups (hazard ratio [HR] 0.89, 95% confidence interval [CI] 0.71-1.11), but it was significantly low among patients who underwent ablation for paroxysmal AF (HR 0.68 [vs. persistent AF], 95% CI 0.49-0.94) and had a CHA2DS2-VASc score < 3 (HR 0.66 [vs. CHA2DS2-VASc score ≥ 3], 95% CI 0.43-0.98]). The 2-year risk reduction achieved by ablation may be small among Japanese patients, but AF ablation may benefit those with paroxysmal AF and a CHA2DS2-VASc score < 3.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Pontuação de Propensão , Sistema de Registros , Medição de Risco/métodos , Acidente Vascular Cerebral/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
13.
Int Heart J ; 61(4): 838-842, 2020 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-32684601

RESUMO

Complex atrial tachycardias (ATs) after catheter ablation or a MAZE procedure is sometimes difficult to determine the circuits of the tachycardia. A high-density, grid-shapes mapping catheter has been launched, which can be useful for detecting the detail circuits of tachycardias on three-dimensional mapping systems. The signal quality is also important for performing electrophysiological studies (EPSs), such as entrainment mapping, to identify the circuit. This unique mapping catheter has 1 mm electrodes on 2.5 Fr shafts, which improve the signal quality. The high-quality intracardiac electrograms facilitate differentiating small critical potentials, which allows us to perform detailed entrainment mapping in targeted narrow areas. Here, we describe a patient with a perimetral AT with epi-endocardium breakthrough after a MAZE surgery and catheter ablation, which was treated successfully along with detailed entrainment mapping using the HD Grid. This catheter with high-quality signals could be a significant diagnostic tool for a classic EPS as well as for the construction of 3D mapping.


Assuntos
Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Complicações Pós-Operatórias/diagnóstico por imagem , Taquicardia Supraventricular/diagnóstico por imagem , Humanos , Masculino , Procedimento do Labirinto , Pessoa de Meia-Idade
14.
Int Heart J ; 61(5): 927-935, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32879263

RESUMO

We prospectively collected device and heart rate data through remote monitoring (RM) of patients with an implantable cardioverter defibrillator (ICD). The objective was to identify the predictors of lethal arrhythmic events (VT/VF).Thirty-three patients (mean age: 50 years) with ICDs [with functionality of heart rate variability (HRV) analysis] were divided into two groups [VT/VF (+), VT/VF (-) ]. Clinical, device (ventricular lead impedance; amplitude of ventricular electrogram), and HRV data were compared between the two groups. The NN interval-index (SDNNi) was calculated for every 5 minutes, and the mean, maximum, minimum, and standard deviation of SDNNi during the 24-hour period were used.During the observation period of 13 ± 10 months, 10 patients experienced VT/VF events. Total mean, max, and min SDNNi were higher in the VT/VF (+) than the VT/VF (-) group (132.9 ± 9.3 versus 93.5 ± 6.1, P = 0.0013; 214.6 ± 10.6 versus 167.0 ± 7.0, P = 0.0007; 71.2 ± 7.5 versus 43.9 ± 4.9, P = 0.0047). On logistic regression analysis, a total mean SDNNi of 100.1, max SDNNi of 185.0 and min SDNNi of 52.0 as cut-off values for prediction of a VT/VF event demonstrated significant receiver operating characteristic (ROC) curves (AUC = 0.86, P = 0.0007; AUC = 0.84, P = 0.0005; AUC = 0.78, P = 0.0030). The max ΔSDNNi, i.e., difference from baseline SDNNi, and min ΔSDNNi in 7 and 28 days preceding VT/VF events were significant predictors of VT/VF events.Time-domain HRV analysis through a RM system may help identify patients at high risk of lethal arrhythmic events; in addition, it may help predict the occurrence of lethal arrhythmic events in specific cases.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Frequência Cardíaca , Taquicardia Ventricular/epidemiologia , Fibrilação Ventricular/epidemiologia , Adulto , Idoso , Síndrome de Brugada/fisiopatologia , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Síndrome do QT Longo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Tecnologia de Sensoriamento Remoto , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/fisiopatologia
15.
Int Heart J ; 61(6): 1165-1173, 2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33191353

RESUMO

Direct oral anticoagulants (DOACs) are sometimes prescribed at off-label under-doses for patients who have undergone ablation for atrial fibrillation (AF). This practice may be an attempt to balance the risk of bleeding against that of stroke or AF recurrence.We examined outcomes of 1163 patients who continued use of a DOAC after ablation. The patients were enrolled in a large (3530 patients) multicenter registry in Japan. The study patients were classified as 749 (64.4%) appropriate standard-dose DOAC users, 216 (18.6%) off-label under-dose DOAC users, and 198 (17.0%) appropriate low-dose DOAC users.Age and CHA2DS2-VASc scores differed significantly between DOAC dosing regimens, with patients given an appropriate standard-dose being significantly younger (63.3 ± 9.4 versus 64.8 ± 9.5 versus 73.2 ± 6.8 years, P < 0.0001) and lower (2.1 ± 1.5 versus 2.4 ± 1.6 versus 3.4 ± 1.4, P < 0.0001) than those given an off-label under-dose or an appropriate low-dose. During the median 19.0-month follow-up period, the AF recurrence rate was similar between the appropriate standard-dose and off-label under-dose groups but relatively low in the appropriate low-dose group (42.5% versus 41.2% versus 35.4%, P = 0.08). Annualized rates of thromboembolic events, major bleeding, and death from any cause were 0.47%, 0.70%, and 0.23% in the off-label under-dose group, while those rates were 0.74%, 0.73%, and 0.65% in the appropriate standard-dose, and 1.58%, 2.12%, and 1.57% in the appropriate low-dose groups.In conclusion, the clinical adverse event rates for patients on an off-label under-dose DOAC regimen after ablation, predicated on careful patient evaluations, was not high as seen with that of patients on a standard DOAC dosing regimen.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Inibidores do Fator Xa/administração & dosagem , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Fibrilação Atrial/complicações , Feminino , Hemorragia/epidemiologia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Mortalidade , Uso Off-Label , Cuidados Pós-Operatórios , Recidiva , Sistema de Registros , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia
16.
Circ J ; 83(4): 736-742, 2019 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-30814400

RESUMO

BACKGROUND: The relationship between atrial high-rate episode (AHRE) burden (i.e., the frequency of atrial tachyarrhythmia) and heart failure (HF) risk is unclear. We hypothesized that new-onset and higher burden of AHRE are associated with HF. Methods and Results: We included 104 consecutive patients with cardiac implantable electronic devices (CIEDs) capable of continuous atrial rhythm monitoring. Patients with AF history were excluded. To stratify patients, AHREs were evaluated only during the initial 1 year after CIED implantation. The primary endpoint was all-cause death or new-onset or worsening HF that required unplanned hospitalization or readjustment of HF drug therapy. At 1 year after CIED implantation, 34/104 patients (33%) exhibited AHREs. No difference in basal clinical characteristics except for left ventricular ejection fraction between patients with and without new-onset AHREs was found. AHRE groups had more HF events than the non-AHRE group. All patients were divided into 3 groups based on AHRE burden: none, low, and high. Worsening HF was observed in 12 patients (12%). Cox hazard analysis revealed that AHRE and higher AHRE burden were independent predictive factors for worsening HF. The high group showed a higher risk for HF than the non-AHRE groups, but no significant difference was found between the low- and non-AHRE groups. CONCLUSIONS: New-onset higher AHRE burden was associated with subsequent risk for HF in patients with CIEDs.


Assuntos
Fibrilação Atrial/complicações , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/etiologia , Idoso , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Volume Sistólico
17.
Circ J ; 83(12): 2418-2427, 2019 11 25.
Artigo em Inglês | MEDLINE | ID: mdl-31619591

RESUMO

BACKGROUND: The safety of discontinuing oral anticoagulant (OAC) after ablation for atrial fibrillation (AF) in Japanese patients has not been clarified.Methods and Results:A study based on the Atrial Fibrillation registry to Follow the long-teRm Outcomes and use of aNTIcoagulants aftER Ablation (AF Frontier Ablation Registry) was conducted. Data were collected from 3,451 consecutive patients (74.1% men; age, 63.3±10.3 years) who had undergone AF ablation at any of 24 cardiovascular centers in Japan between August 2011 and July 2017. During a 20.7-month follow-up period, OAC therapy was discontinued in 1,836 (53.2%) patients; 51 patients (1.5%) suffered a stroke/transient ischemic attack (TIA), 71 (2.1%) suffered major bleeding, and 36 (1.0%) died. Patients in whom OAC therapy was discontinued were significantly younger than those in whom OACs were continued, and their CHA2DS2-VASc scores were significantly lower. The incidences of stroke/TIA, major bleeding, and death were significantly lower among these patients. Upon multivariate adjustment, stroke events were independently associated with relatively high baseline CHA2DS2-VASc scores but not with OAC status. CONCLUSIONS: Although the incidences of stroke/TIA, major bleeding, and death were relatively low among patients for whom OAC therapy was discontinued, stroke/TIA occurrence was strongly associated with a high baseline stroke risk rather than with OAC status. Thus, discontinuation of OAC therapy requires careful consideration, especially in patients with a high baseline stroke risk.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/terapia , Ablação por Cateter , Ataque Isquêmico Transitório/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Esquema de Medicação , Feminino , Hemorragia/induzido quimicamente , Humanos , Incidência , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/mortalidade , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
18.
J Thromb Thrombolysis ; 47(4): 487-494, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30955142

RESUMO

Anticoagulants are prescribed for prevention of thromboembolic events (TE) of atrial fibrillation (AF), however, their effects have a negative impact on disastrous bleeding outcomes. Idarucizumab was developed to reverse the anticoagulation effects of dabigatran. This study aimed to retrospectively investigate the clinical efficacy and safety of idarucizumab in the setting of progressive emergent bleeding events associated with catheter ablation (CA). Dabigatran is given uninterruptedly as an anticoagulant in patients undergoing CA of AF. The capacity of idarucizumab to reverse the anticoagulant effects of dabigatran in patients with cardiac tamponade associated with CA was examined by measuring the activated partial thromboplastin time (aPTT), active clotting time (ACT), and prothrombin international normalizing ratio (PT-INR). The primary endpoint was effective hemostasis. This analysis included 21 patients receiving idarucizumab, given for restoration of hemostasis. In all 21 patients, hemostasis was restored at a median of 205.6 ± 14.8 min. Normal intraoperative cessation of bleeding was reported in 16 patients, and completion of hemostasis was also ascertained in the remaining four within 5 h. No TEs occurred within 72 h after the idarucizumab administration. Despite a significant reduction in the aPTT and ACT, no significant change was observed in PT-INR after administering idarucizumab. In emergency situations, idarucizumab was able to reverse dabigatran within a relatively short period without any serious adverse events.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Fibrilação Atrial/terapia , Tamponamento Cardíaco/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Dabigatrana/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais Humanizados/efeitos adversos , Fibrilação Atrial/fisiopatologia , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/fisiopatologia , Dabigatrana/administração & dosagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Heart Vessels ; 34(8): 1389-1393, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30762094

RESUMO

We have shown that a dipeptidyl peptidase 4 (DPP-4) inhibitor suppresses atrial remodeling in a canine atrial fibrillation (AF) model. Glucagon-like peptide-1 (GLP-1) is increased by DPP-4 inhibitors. However, it is not clear whether GLP-1 is involved in the suppression of atrial remodeling. In this study, we evaluated the effect of liraglutide (a GLP-1 analog) on atrial electrophysiological changes using the same canine AF model. We established a canine AF model using continuous 3-week rapid atrial stimulation in seven beagle dogs divided into two groups: a liraglutide group with four dogs (3-week atrial pacing with liraglutide (150 µg/kg/day) administration) and a pacing control group with three dogs (3-week pacing without any medicine). We evaluated the atrial effective refractory period (AERP), conduction velocity (CV), and AF inducibility every week during the protocol using implanted epicardial wires against the surfaces of both atria. In the pacing control group, the AERP was gradually shortened and the CV was decreased along the time course. In the liraglutide group, the AERP was similarly shortened as in the pacing control group (94 ± 4% versus 85 ± 2%, respectively; p = 0.5926), but the CV became significantly higher than that in the pacing control group after 2 and 3 weeks (95 ± 4 versus 83 ± 5%, respectively; p = 0.0339). The AF inducibility was gradually increased in the pacing control group, but it was suppressed in the liraglutide group (5 ± 9% versus 73 ± 5%; p = 0.0262). Liraglutide suppressed electrophysiological changes such as AF inducibility and CV decrease in our canine AF model.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Remodelamento Atrial/efeitos dos fármacos , Átrios do Coração/efeitos dos fármacos , Liraglutida/farmacologia , Animais , Estimulação Cardíaca Artificial , Cães , Fenômenos Eletrofisiológicos , Feminino , Átrios do Coração/fisiopatologia
20.
Int Heart J ; 60(6): 1321-1327, 2019 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-31735777

RESUMO

Optimal antithrombotic strategy for atrial fibrillation (AF) patients with a history of percutaneous coronary intervention (PCI) has been under debate. The actual prescription trend of antithrombotic therapy for these patients remains unclear, especially in chronic phase.Patients with AF having at least a 1-year history of PCI were retrospectively evaluated in 2010, 2012, 2014, and 2016. A total of 266 patients were finally enrolled in this study. The proportion of patients prescribed with oral anticoagulants (OACs) gradually increased over the study period (56%, 67%, 73%, and 74% in 2010, 2012, 2014, and 2016, respectively). According to the type of OACs, the proportion of direct oral anticoagulant (DOAC), launched in 2011, increased compared with warfarin (DOAC versus warfarin = 3% versus 64% in 2012, 24% versus 49% in 2014, and 32% versus 42% in 2016). Single antiplatelet therapy (SAPT) with OAC was the most popular prescription every year, and its proportion increased over the study period (41%, 44%, 55%, and 59%, respectively). The proportion of OAC monotherapy gradually increased (2%, 3%, 8%, and 9%, respectively), whereas that of triple therapy, i.e., dual antiplatelet therapy with OAC, gradually decreased (14%, 22%, 8%, and 5% in 2010, 2012, 2014, and 2016, respectively).Antithrombotic therapy trends for AF patients with a history of PCI were changing every year. The prescription rate of triple therapy gradually decreased, in contrast, that of OAC monotherapy gradually increased from 2010 to 2016. However, the evidence for OAC monotherapy in these patients remains insufficient.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Intervenção Coronária Percutânea , Padrões de Prática Médica , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Combinada , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA