Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-28264852

RESUMO

The liver is crucial to pharmacology, yet substantial knowledge gaps exist in the understanding of its basic pharmacologic processes. An improved understanding for humans requires reliable and reproducible liver sampling methods. We compared liver concentrations of paritaprevir and ritonavir in rats by using samples collected by fine-needle aspiration (FNA), core needle biopsy (CNB), and surgical resection. Thirteen Sprague-Dawley rats were evaluated, nine of which received paritaprevir/ritonavir at 30/20 mg/kg of body weight by oral gavage daily for 4 or 5 days. Drug concentrations were measured using liquid chromatography-tandem mass spectrometry on samples collected via FNA (21G needle) with 1, 3, or 5 passes (FNA1, FNA3, and FNA5); via CNB (16G needle); and via surgical resection. Drug concentrations in plasma were also assessed. Analyses included noncompartmental pharmacokinetic analysis and use of Bland-Altman techniques. All liver tissue samples had higher paritaprevir and ritonavir concentrations than those in plasma. Resected samples, considered the benchmark measure, resulted in estimations of the highest values for the pharmacokinetic parameters of exposure (maximum concentration of drug in serum [Cmax] and area under the concentration-time curve from 0 to 24 h [AUC0-24]) for paritaprevir and ritonavir. Bland-Altman analyses showed that the best agreement occurred between tissue resection and CNB, with 15% bias, followed by FNA3 and FNA5, with 18% bias, and FNA1 and FNA3, with a 22% bias for paritaprevir. Paritaprevir and ritonavir are highly concentrated in rat liver. Further research is needed to validate FNA sampling for humans, with the possible derivation and application of correction factors for drug concentration measurements.


Assuntos
Fígado/metabolismo , Compostos Macrocíclicos/farmacocinética , Ritonavir/farmacocinética , Animais , Biópsia por Agulha Fina , Cromatografia Líquida , Ciclopropanos , Hepatócitos/metabolismo , Inativação Metabólica/fisiologia , Lactamas Macrocíclicas , Fígado/cirurgia , Masculino , Prolina/análogos & derivados , Ratos , Ratos Sprague-Dawley , Sulfonamidas , Espectrometria de Massas em Tandem
2.
Cytotherapy ; 16(11): 1558-1574, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24927716

RESUMO

BACKGROUND AIMS: Evaluation of the BD Stem Cell Enumeration Kit was conducted at four clinical sites with flow cytometry CD34(+) enumeration to assess agreement between two investigational methods: (i) the BD FACSCanto II and BD FACSCalibur systems and (ii) the predicate method (Beckman Coulter StemKit and StemTrol, Immunotech SAS, Beckman Coulter, Marseille Cedex 9, France). METHODS: Leftover and delinked specimens (n = 1032) from clinical flow cytometry testing were analyzed on the BD FACSCanto II (n = 918) and BD FACSCalibur (n = 905) in normal and mobilized blood, frozen and thawed bone marrow and leucopheresis and cord blood anticoagulated with citrate phosphate dextrose, anticoagulant citrate dextrose-solution A, heparin and ethylenediaminetetraacetate, alone or in combination. Fresh leucopheresis analysis addressed site equivalency for sample preparation, testing and analysis. RESULTS: The mean relative bias showed agreement within predefined parameters for the BD FACSCanto II (-2.81 to 4.31 ±7.1) and BD FACSCalibur (-2.69 to 5.2 ±7.9). Results are reported as absolute and relative differences compared with the predicate for viable CD34(+), percentage of CD34(+) in CD45(+) and viable CD45(+) populations (or gates). Bias analyses of the distribution of the predicate low, mid and high bin values were done using BD FACSCanto II optimal gating and BD FACSCalibur manual gating for viable CD34(+), percentage of CD34(+) in CD45(+) and viable CD45(+). Bias results from both investigational methods show agreement. Deming regression analyses showed a linear relationship with R(2) > 0.92 for both investigational methods. DISCUSSION: In conclusion, the results from both investigational methods demonstrated agreement and equivalence with the predicate method for enumeration of absolute viable CD34(+), percentage of viable CD34(+) in CD45(+) and absolute viable CD45(+) populations.


Assuntos
Antígenos CD34/metabolismo , Citometria de Fluxo/métodos , Transplante de Células-Tronco , Células-Tronco/citologia , Antígenos CD34/imunologia , Contagem de Células , Linhagem da Célula/genética , Sangue Fetal/citologia , Sangue Fetal/imunologia , Citometria de Fluxo/instrumentação , Humanos , Células-Tronco/imunologia
3.
Cytometry B Clin Cytom ; 90(5): 415-23, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26663713

RESUMO

Hematopoietic stem cells are the source of all inflammatory cell types. Discovery of specific cell surface markers unique to human hematopoietic stem (HSC) and progenitor (HSPC) cell populations has facilitated studies of their development from stem cells to mature cells. The specific marker profiles of HSCs and HSPCs can be used to understand their role in human inflammatory diseases. The goal of this study is to simultaneously measure HSCs and HSPCs in normal human venous blood using multicolor flow cytometry. Our secondary aim is to determine how G-CSF mobilization alters the quantity of each HSC and HSPC population. Here we show that cells within the CD34+ fraction of human venous blood contains cells with the same cell surface markers found in human bone marrow samples. Mobilization with G-CSF significantly increases the quantity of total CD34+ cells, blood borne HSCs, multipotent progenitors, common myeloid progenitors, and megakaryocyte erythroid progenitors as a percentage of total MNCs analyzed. The increase in blood borne common lymphoid and granulocyte macrophage progenitors with G-CSF treatment did not reach significance. G-CSF treatment predominantly increased the numbers of HSCs and multipotent progenitors in the total CD34+ cell population; common myeloid progenitors and megakaryocyte erythroid progenitors were enriched relative to total MNCs analyzed, but not relative to total CD34+ cells. Our findings illustrate the utility of multicolor flow cytometry to quantify circulating HSCs and HSPCs in venous blood samples from human subjects. © 2016 International Clinical Cytometry Society.


Assuntos
Linhagem da Célula/imunologia , Citometria de Fluxo , Fator Estimulador de Colônias de Granulócitos/metabolismo , Células-Tronco Hematopoéticas/citologia , Células-Tronco/citologia , Antígenos CD34/metabolismo , Medula Óssea/metabolismo , Diferenciação Celular/fisiologia , Células Cultivadas , Citometria de Fluxo/métodos , Mobilização de Células-Tronco Hematopoéticas/métodos , Humanos , Imunofenotipagem
4.
Cytometry B Clin Cytom ; 88(1): 6-20, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25338522

RESUMO

The enumeration of antigen-specific T cells is increasingly relevant in clinical and research settings. This information is useful for evaluating immune responses to treatment, monitoring the efficacy of anticancer vaccines, and for detecting self-reactive T cells in autoimmune disorders. Quantifying antigen-specific T cells can be accomplished via IFNγ ELISpot assay, the measurement of intracellular cytokine production by flow cytometry, or by lymphocyte proliferation assays in response to antigen. While robust, these technologies are labor-intensive and can take several days to obtain results. New technology has led to more powerful tools for quickly and accurately measuring antigen-specific T cells by flow cytometry via fluorescently-labeled TCR-specific multimers. In this study, we evaluated the use of an assay based on Dextramer reagents for enumerating cytomegalovirus (CMV) antigen-specific T cells (CASTs). Assay performance characteristics were assessed by establishing Dextramers' sensitivity (median=0.4; range=0.1-1.4 CASTs µl(-1) ), determining their specificity (100%), evaluating assay robustness with different leukocyte sources and assay reproducibility via interlaboratory and interinstrument investigations. Furthermore, the levels of CASTs in 95 peripheral blood samples from 62 unique blood and marrow transplants recipients correlated well between Dextramers and Tetramers (R(2) =0.9042).


Assuntos
Antígenos Virais/sangue , Infecções por Citomegalovirus/sangue , Citomegalovirus/imunologia , Indicadores e Reagentes/química , Leucócitos Mononucleares/imunologia , Receptores de Antígenos de Linfócitos T/imunologia , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/imunologia , Infecções por Citomegalovirus/virologia , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Corantes Fluorescentes , Humanos , Leucócitos Mononucleares/virologia , Variações Dependentes do Observador , Ficoeritrina , Sensibilidade e Especificidade , Coloração e Rotulagem/métodos , Especificidade do Receptor de Antígeno de Linfócitos T
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA