Artif Organs ; 47(8): 1371-1385, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37042612

RESUMO

BACKGROUND: Controlled donation after circulatory determination of death (cDCD) seems an effective way to mitigate the critical shortage of available organs for transplant worldwide. As a recently developed procedure for organ retrieval, some questions remain unsolved such as the uncertainty regarding the effect of functional warm ischemia time (FWIT) on organs´ viability. METHODS: We developed a multicenter prospective cohort study collecting all data from evaluated organs during cDCD from 2017 to 2020. All the procedures related to cDCD were performed with normothermic regional perfusion. The analysis included organ retrieval as endpoint and FWIT as exposure of interest. The effect of FWIT on the likelihood for organ retrieval was evaluated with Relative distribution analysis. RESULTS: A total amount of 507 organs´ related information was analyzed from 95 organ donors. Median donor age was 62 years, and 63% of donors were male. Stroke was the most common diagnosis before withdrawal of life-sustaining therapy (61%), followed by anoxic encephalopathy (21%). This analysis showed that length of FWIT was inversely associated with organ retrieval rates for liver, kidneys, and pancreas. No statistically significant association was found for lungs. CONCLUSIONS: Results showed an inverse association between functional warm ischemia time (FWIT) and retrieval rate. We also have postulated optimal FWIT's thresholds for organ retrieval. FWIT for liver retrieval remained between 6 and less than 11 min and in case of kidneys and pancreas, the optimal FWIT for retrieval was 6 to 12 min. These results could be valuable to improve organ utilization and for future analysis.


Assuntos
Oxigenação por Membrana Extracorpórea , Obtenção de Tecidos e Órgãos , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Isquemia Quente , Estudos Prospectivos , Preservação de Órgãos/métodos , Perfusão/métodos , Morte , Sobrevivência de Enxerto
2.
BMJ Open ; 14(7): e084849, 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39019641

RESUMO

INTRODUCTION: Oxygen is frequently prescribed in neurocritical care units. Avoiding hypoxaemia is a key objective in patients with acute brain injury (ABI). However, several studies suggest that hyperoxaemia may also be related to higher mortality and poor neurological outcomes in these patients. The evidence in this direction is still controversial due to the limited number of prospective studies, the lack of a common definition for hyperoxaemia, the heterogeneity in experimental designs and the different causes of ABI. To explore the correlation between hyperoxaemia and poor neurological outcomes and mortality in hospitalised adult patients with ABI, we will conduct a systematic review and meta-analysis of observational studies and RCTs. METHODS AND ANALYSIS: The systematic review methods have been defined according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and follow the PRISMA-Protocols structure. Studies published until June 2024 will be identified in the electronic databases MEDLINE, Embase, Scopus, Web of Science, The Cochrane Library, Cumulative Index to Nursing and Allied Health Literature and ClinicalTrials.gov. Retrieved records will be independently screened by four authors working in pairs, and the selected variables will be extracted from studies reporting data on the effect of 'hyperoxaemia' versus 'no hyperoxaemia on neurological outcomes and mortality in hospitalised patients with ABI. We will use covariate-adjusted ORs as outcome measures when reported since they account for potential cofounders and provide a more accurate estimate of the association between hyperoxaemia and outcomes; when not available, we will use univariate ORs. If the study presents the results as relative risks, it will be considered equivalent to the OR as long as the prevalence of the condition is close to 10%. Pooled estimates of both outcomes will be calculated applying random-effects meta-analysis. Interstudy heterogeneity will be assessed using the I2 statistic; risk of bias will be assessed through Risk Of Bias In Non-Randomised Studies of Interventions, Newcastle-Ottawa or RoB2 tools. Depending on data availability, we plan to conduct subgroup analyses by ABI type (traumatic brain injury, postcardiac arrest, subarachnoid haemorrhage, intracerebral haemorrhage and ischaemic stroke), arterial partial pressure of oxygen values, study quality, study time, neurological scores and other selected clinical variables of interest. ETHICS AND DISSEMINATION: Specific ethics approval consent is not required as this is a review of previously published anonymised data. Results of the study will be shared with the scientific community via publication in a peer-reviewed journal and presentation at relevant conferences and workshops. It will also be shared key stakeholders, such as national or international health authorities, healthcare professionals and the general population, via scientific outreach journals and research institutes' newsletters.


Assuntos
Lesões Encefálicas , Metanálise como Assunto , Revisões Sistemáticas como Assunto , Humanos , Lesões Encefálicas/mortalidade , Lesões Encefálicas/complicações , Hiperóxia/etiologia , Hiperóxia/mortalidade , Projetos de Pesquisa
3.
Anesth Analg ; 111(5): 1176-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20841411

RESUMO

BACKGROUND: The Anesthetic Conserving Device--AnaConDa® (ACD)--has been compared with a conventional vaporizer. However, the accuracy of the administered concentration of volatile anesthetics was not examined. In the present study we measured the accuracy of the ACD when used as a portable vaporizer. METHODS: This prospective study included 30 ASA I-III patients scheduled for elective surgery under general anesthesia. The patients were randomly organized into 3 groups of 10 patients per group. In each group, the sevoflurane infusion rate was adjusted to deliver 1.0 vol%, 1.5 vol%, and 2.0 vol% alveolar concentration. Hemodynamic data, bispectral index, and end-tidal sevoflurane concentrations were recorded every 2 minutes. RESULTS: We analyzed 801 data points from 30 patients. The mean difference between the end-tidal sevoflurane concentration and the target concentration was -11.0 ± 9.3% of the target when the target was 1.0 vol%, -5.4 ± 6.4% when the target was 1.5 vol%, and -4.0 ± 7.4% when the target was 2.0 vol%. No significant differences were found in the error at the different target concentrations. CONCLUSIONS: We found that the ACD may be a valid alternative to the conventional vaporizer. The ACD is very simple to use, delivery rate needs to be adjusted only once per hour, and the anesthetic savings are independent of the circuit characteristics and fresh gas flow rate.


Assuntos
Anestesia com Circuito Fechado/instrumentação , Anestesia Geral/instrumentação , Anestesia por Inalação/instrumentação , Anestésicos Inalatórios/administração & dosagem , Éteres Metílicos/administração & dosagem , Administração por Inalação , Adulto , Idoso , Anestésicos Inalatórios/farmacocinética , Monitores de Consciência , Procedimentos Cirúrgicos Eletivos , Desenho de Equipamento , Feminino , Hemodinâmica , Humanos , Masculino , Éteres Metílicos/farmacocinética , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Estudos Prospectivos , Sevoflurano , Espanha , Volume de Ventilação Pulmonar , Fatores de Tempo
4.
Anesth Analg ; 105(5): 1458-61, table of contents, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17959983

RESUMO

BACKGROUND: Spinal cord stimulation (SCS) is used to treat chronic pain and requires an awake patient for optimized lead positioning to locate paresthesias. Epidural anesthesia may be a suitable anesthetic but has not been evaluated. METHODS: We performed an open-label, prospective, observational, single-center study to evaluate the safety and efficacy of laminectomy lead placement under epidural anesthesia for the treatment of neuropathic chronic pain. RESULTS: The results in our study demonstrate that epidural anesthesia is a suitable technique for SCS lead implant. CONCLUSIONS: This is the first study using epidural anesthesia for SCS lead implants by laminectomy. The technique seems to be safe and effective.


Assuntos
Anestesia Epidural/instrumentação , Terapia por Estimulação Elétrica/instrumentação , Laminectomia/instrumentação , Dor Intratável/cirurgia , Medula Espinal/cirurgia , Idoso , Anestesia Epidural/métodos , Terapia por Estimulação Elétrica/métodos , Feminino , Humanos , Laminectomia/métodos , Masculino , Pessoa de Meia-Idade , Dor Intratável/patologia , Estudos Prospectivos , Medula Espinal/patologia
SELEÇÃO DE REFERÊNCIAS