Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Andrologia ; 54(2): e14324, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34806200

RESUMO

The purpose of this study is to evaluate the results of two courses of low-intensity shock wave therapy (Li-SWT) in the treatment of patients with erectile dysfunction (ED). Between June 2015 and December 2020, diabetic and non-diabetic patients with ED treated with two Li-SWT courses were evaluated retrospectively among the data of 317 patients. The outcomes were evaluated using the International Index of Erectile Function-Erectile Function Domain (IIEF-EF) questionnaire values at baseline and 6 months post-treatment for each Li-SWT course with (0.09 mJ/mm²) 18000 shock waves. Successful treatment criteria for patients who also underwent physical examination and anamnesis before and after each course were IIEF-EF scores≥26 during the 6 months follow-up. Forty-one patients with a mean age of 51.61 ± 11.80 years were included in the study. The mean IIEF-EF scores were 15.17 ± 3.75 at baseline, 21.61 ± 3.60 after the first course [mean difference(MD): -6.439; 95%, confidence interval(CI), -7.138: -5.740; t = -18.621; p < 0.001], and 25.27 ± 4.05 after the second course(MD: -3.658; 95% CI, -4,067: -3.249; t = -18,071; p < 0.001). Evaluation of score increases in diabetic patients was also statistically significant for each course (p < 0.001). Our study shows that two courses of Li-SWT treatments are safe for both diabetic and non-diabetic patients with ED and effective for each course.


Assuntos
Disfunção Erétil , Tratamento por Ondas de Choque Extracorpóreas , Ondas de Choque de Alta Energia , Adulto , Disfunção Erétil/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Ereção Peniana , Estudos Retrospectivos
2.
Andrologia ; 53(10): e14197, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34350629

RESUMO

We aimed to compare the efficacy of low-intensity shock wave therapy (Li-SWT) alone and its combination with platelet-rich plasma (PRP) in the treatment of patients with erectile dysfunction (ED). Between January 2015 and October 2020, patients who did not benefit from the use of phosphodiesterase type 5 inhibitors (PDE5i; 5 mg/day) for at least 3 months and underwent Li-SWT or Li-SWT with PRP were evaluated retrospectively. There were 93 patients who were subjected to Li-SWT only (Group 1) and 91 patients subjected to Li-SWT with PRP (Group 2). Analysis of the International Index of Erectile Function-Erectile Function Area (IIEF-EF) scores showed a significant increase in both the groups post-treatment (Group 1: from 14.33 ± 4.39 to 23.8 ± 4.37, p = .001; Group 2: from 17.82 ± 3.44 to 26.3 ± 2.55, p = .001). When the increase in the IIEF-EF scores was compared pre- and post-treatment between the groups with respect to the ED grades, there was no statistically significant difference between them. Furthermore, while the intravaginal ejaculatory latency time (IELT) in successfully treated patients of Group 1 remained the same, Group 2 presented 1.5-3.5 times (mean, 2.4) prolongation. Their mean IELT score showed an increase from 2.2 (0.8-3.5) min to 5.3 (2.8-10.5) min. Our study shows that combination treatment of Li-SWT with PRP injections is not only safe for patients with ED, but also effective and safe in prolonging the IELT.


Assuntos
Disfunção Erétil , Tratamento por Ondas de Choque Extracorpóreas , Plasma Rico em Plaquetas , Disfunção Erétil/terapia , Humanos , Masculino , Inibidores da Fosfodiesterase 5/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento
3.
Acta Neurochir (Wien) ; 158(8): 1545-53, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27250849

RESUMO

BACKGROUND: Stent-assisted coiling using low-profile, self-expandable and retrievable stents is a valid option in endovascular treatment of challenging intracranial aneurysms. This study aims to evaluate the feasibility and efficacy of ACCLINO 1.9 F and ACCLINO Flex stent systems, designed for use as adjunctive products in coil embolization of intracranial aneurysms. METHODS: Case files of 47 patients, and 52 aneurysms in total, treated with at least one ACCLINO 1.9 F or ACCLINO Flex stent were retrospectively evaluated. Technical success, complications, and angiographic outcomes were assessed based on immediate post-procedural controls along with 6th and 12th month angiograms. RESULTS: Mechanical untoward event rate, including asymptomatic complications, is 9.6 % (five out of 52 aneurysms). Failed dual-stenting attempt rate is 15.4 % (two out of 13). Overall procedure-related morbidity is 4.2 % with no neurologic sequelae. Initial occlusion rate is 90.4 % (47 aneurysms). One patient had residual filling in the aneurysm neck, which was stable throughout follow-up. The remaining four cases had spontaneous follow-up occlusion. Recanalization rate at 6th month is 2.1 % with one aneurysm requiring retreatment. One patient was lost to follow-up. There is no mortality associated with treatment. CONCLUSIONS: Stent-assisted coil embolization with ACCLINO stents in single or dual configurations is a feasible treatment option for challenging intracranial aneurysms. Follow-up results are encouraging; techniques were effective in complex cases and there were no clinically significant adverse outcomes.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Stents/efeitos adversos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/instrumentação , Humanos , Resultado do Tratamento
4.
Eur Spine J ; 24(1): 187-92, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25351839

RESUMO

INTRODUCTION: Spinal intramedullary arteriovenous malformations are uncommon and a challenging type of neurosurgical entities. They are rarely located to cervical segment. On the other hand, although hemangiomas are relatively common bone tumors, cervical involvement is again rare and clinically significant ones are infrequent. CASE PRESENTATION: A 14 year-old-male patient referred to an academic tertiary care unit and presented with neck pain and left hand weakness. Neurological examination revealed motor strength deficit at intrinsic muscles and hyperesthesia at the left hand. Furthermore the pathological reflexes were positive on the left hand side. Imaging studies showed compression fracture, lytic changes resembling a hemangioma at C7 vertebra, and also an intramedullary vascular pathology at C5-6 level which was shown to be an intradural-intramedullary arteriovenous malformation (AVM) on digital subtraction angiography. Based on neurological and radiological findings, the decision was to treat the patient. After embolization of the AVM, the neurological condition of the patient deteriorated and immediate MRI scan of the cervical spine revealed edema of the spinal cord at the C5-6 level. Thus an emergent surgery was performed and C5-6-7 laminectomies with C5-T2 posterior fixation and arthrodesis were implemented. A second stage operation was carried out as C7 corpectomy with a distractable titanium cage 2 weeks after initial surgery. A follow-up evaluation at five years revealed 4/5 motor strength on his left intrinsic hand muscles and mild hyperactive deep tendon reflexes. Imaging studies at the postoperative period showed stable placement of the construct and no evidence of contrast enhancement at the C5-6 level inside the spinal cord. CONCLUSION: A rare case of multiple pathologies affecting the cervical spine, coincidentally diagnosed after a pathological fracture during a bicycle accident as vertebral hemangioma and intradural-intramedullary AVM that was successfully treated with early detection, have been presented. One should assess such patients under multidisciplinary fashion and treat on a case-by-case basis for achieving the best results in patient care.


Assuntos
Malformações Arteriovenosas/diagnóstico , Ciclismo/lesões , Vértebras Cervicais/lesões , Hemangioma/diagnóstico , Fraturas da Coluna Vertebral/etiologia , Neoplasias da Coluna Vertebral/diagnóstico , Adolescente , Angiografia Digital , Malformações Arteriovenosas/terapia , Vértebras Cervicais/patologia , Vértebras Cervicais/cirurgia , Embolização Terapêutica , Fixação Interna de Fraturas , Hemangioma/terapia , Humanos , Laminectomia , Imageamento por Ressonância Magnética , Masculino , Compressão da Medula Espinal/etiologia , Compressão da Medula Espinal/cirurgia , Fraturas da Coluna Vertebral/diagnóstico , Fraturas da Coluna Vertebral/cirurgia , Fusão Vertebral , Neoplasias da Coluna Vertebral/terapia
5.
Interv Neuroradiol ; : 15910199241254409, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38772613

RESUMO

BACKGROUND: Reperfusion of medium vessel occlusions is correlated with good outcomes. However, optimal techniques and medical devices are still unclear. In this study, we sought to evaluate the safety and efficacy of mechanical thrombectomy with Embolus Retriever with Interlinked Cages (ERIC™) retrieval device in patients with acute ischemic stroke due to distal medium vessel occlusions. METHODS: A retrospective review of the prospectively collected mechanical thrombectomy database revealed 50 patients who had fulfilled the inclusion criteria. The data collected includes clinical patient characteristics, procedural measures, timestamps at each stage, and patient outcomes. Intravenous thrombolytics application, pre- and post-intervention imaging findings, device-related adverse events and any type of intracranial hemorrhage were recorded. RESULTS: There were 25 men (50%) and 25 women (50%) with a median of 67 years (interquartile range (IQR) 41-84). Median presenting NIHSS was 14 (IQR, 3-23). First pass rates were: eTICI3 in 16 cases (32%), eTICI-2c in eight cases (16%), eTICI-2B67 in nine cases (10%), eTICI2B50 in three cases (6%) and mTICI 0-2A in 18 cases (36%). Final recanalization rate of mTICI 2b-3 was 90% and 2c-3 was 70%. CONCLUSION: In conclusion, the ERIC thrombectomy device offers a high rate of first-pass success along with a favorable safety profile. Larger series and multi-center studies are needed for further investigation.

6.
Interv Neuroradiol ; : 15910199241239094, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38515399

RESUMO

BACKGROUND: The best strategy to achieve optimal reperfusion outcomes during mechanical thrombectomy remains to be defined. The RapidPulseTM Cyclic Aspiration System is a novel technology, delivering high-frequency pulsed vacuum forces to increase the efficiency of aspiration thrombectomy. METHODS: Prospective, multicenter, open-label, core lab-adjudicated, two-arm study comparing safety and efficacy of a feasibility version of the RapidPulseTM system compared with contemporary controls. Primary endpoint was the rate of mTICI ≥ 2c after first-pass effect (FPE). Additional efficacy endpoints were the rates of mTICI ≥ 2b after first pass (modified FPE (mFPE)), last pass with study device defined as frontline technical success, and after all passes including rescue therapy. The primary safety endpoints included symptomatic ICH (sICH) within 24 h post-procedure. RESULTS: Between February 2022 to December 2022, 80 subjects were consented and enrolled in the study (n = 40 treatment arm, n = 40 control arm). In the intent to treat (ITT) population, mean age was 67.8 ± 11.5 years; 19 (47.5%) were male. Median NIHSS score was 16 (IQR: 13-22). Median ASPECTS score was 9 (IQR: 8-10). The rate of mTICI ≥ 2c after first pass was 53.9% in ITT population (60.0% in per-protocol population) versus 38.5% in the corresponding control population. Functional independence (mRS 0-2) at 90 days was achieved in 61.1% (22/36) in the RapidPulseTM arm and 52.8% (19/36) in the control arm. In the RapidPulseTM arm, no sICH within 24 h and no device-related morbidity or mortality occurred. CONCLUSION: Preliminary data suggests RapidPulseTM Aspiration System is highly effective and safe for recanalization of large vessel occlusions.

7.
Arch Esp Urol ; 76(7): 487-493, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37867333

RESUMO

BACKGROUND: The aim of the present study is to evaluate and analyze the daily clinical practice for male urethral stricture disease (MUSD) among urologists. METHODS: Considering the latest guidelines on urethral stricture disease, a survey was developed regarding the various treatment options and preferences in different sites of male urethral stricture disease. The survey was sent to urologists via e-mail and phone application. RESULTS: A total of 266 urologists completed the survey and were included in the final analysis. In regard to workplace, 62 (23.3%), 58 (21.8%), 71 (26.7%), and 75 (28.2%) respondents worked in university hospitals, training and research hospitals, state hospitals, and private practice hospitals, respectively. In regard to the diagnostic method used in male urethral strictures, 88.7% of the participants would choose uroflowmetry + postvoiding residual (UF + PVR), and 64.6% would choose retrograde urethrography (RUG). Direct vision internal urethrotomy (DVIU) was the most frequently chosen method in penile urethral strictures (PUS), being chosen by 72.9%. Direct vision anterior internal urethrotomy was the most common method for both ≤2 cm and >2 cm strictures, 63.1%, and 30.8%, respectively. The most preferred graft for augmentation urethroplasty was buccal mucosa (75.8%). Endoscopic incision/resection (transurethral resection (TUR)) is the most frequently applied treatment method for posterior urethral/vesicourethral anastomotic strictures (86.4%). CONCLUSIONS: The present study clearly shows that most urologists still prefer DVIU and urethral dilatation to urethroplasty in MUSD, which contradicts current guidelines. Urologists should be encouraged to perform urethroplasty and/or refer patients to experienced centres for recurrent MUSD.


Assuntos
Estreitamento Uretral , Humanos , Masculino , Estreitamento Uretral/diagnóstico , Estreitamento Uretral/cirurgia , Urologistas , Constrição Patológica/cirurgia , Procedimentos Cirúrgicos Urológicos Masculinos/métodos , Uretra/cirurgia
8.
J Neurointerv Surg ; 2023 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-38050090

RESUMO

BACKGROUND: Challenges to revascularization of large vessel occlusions (LVOs) persist. Current stent retrievers have limited effectiveness for removing organized thrombi. The NeVa device is a novel stent retriever designed to capture organized thrombi within the scaffold during retrieval. OBJECTIVE: To evaluate the safety and effectiveness of revascularization of acute LVOs with the NeVa device. METHODS: Prospective, international, multicenter, single-arm, Investigational Device Exemption study to evaluate the performance of the NeVa device in recanalizing LVOs including internal carotid artery, M1/M2 middle cerebral artery, and vertebrobasilar arteries, within 8 hours of onset. Primary endpoint was rate of expanded Treatment in Cerebral Ischemia (eTICI) score 2b-3 within 3 NeVa passes, tested for non-inferiority against a performance goal of 72% with a -10% margin. Additional endpoints included first pass success and 90-day modified Rankin Scale (mRS) score 0-2. Primary composite safety endpoint was 90-day mortality and/or 24-hour symptomatic intracranial hemorrhage (sICH). RESULTS: From April 2021 to April 2022, 139 subjects were enrolled at 25 centers. Median National Institutes of Health Stroke Scale (NIHSS) score was 16 (IQR 12-20). In the primary analysis population (n=107), eTICI 2b-3 within 3 NeVa passes occurred in 90.7% (97/107; non-inferiority P<0.0001; post hoc superiority P<0.0001). First pass eTICI 2b-3 was observed in 73.8% (79/107), with first pass eTICI 2b67-3 in 69.2% (74/107) and eTICI 2c-3 in 48.6% (52/107). Median number of passes was 1 (IQR 1-2). Final eTICI 2b-3 rate was 99.1% (106/107); final eTICI 2b67-3 rate was 91.6% (98/107); final eTICI 2c-3 rate was 72.9% (78/107). Good outcome (90-day mRS score 0-2) was seen in 65.1% (69/106). Mortality was 9.4% (13/138) with sICH in 5.0% (7/139). CONCLUSIONS: The NeVa device is highly effective and safe for revascularization of LVO strokes and demonstrates superior first pass success compared with a predicate performance goal. TRIAL REGISTRATION NUMBER: NCT04514562.

9.
J Obstet Gynaecol Res ; 38(2): 427-30, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22176388

RESUMO

Carotid-cavernous aneurysm accounts for 2-9% of all intracranial aneurysms. The rupture of carotid-cavernous aneurysm is usually caused by a trauma. Nevertheless, spontaneous rupture may rarely be encountered. Here, we report a term pregnant woman who was diagnosed to have a spontaneous carotid-cavernous fistula due to carotid-cavernous aneurysm rupture and was managed with detachable balloon and coils immediately after cesarean section.


Assuntos
Aneurisma Roto/complicações , Doenças das Artérias Carótidas/complicações , Fístula Carótido-Cavernosa/etiologia , Seio Cavernoso , Aneurisma Intracraniano/complicações , Complicações na Gravidez/etiologia , Adulto , Feminino , Humanos , Gravidez , Ruptura Espontânea
10.
Interv Neuroradiol ; : 15910199221135309, 2022 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-36314456

RESUMO

BACKGROUND: Occlusive thrombi in acute ischemic stroke can be in various types which limits the success of the thrombectomy. The NeVaTM (Vesalio, Nashville, Tennessee) thrombectomy device was originally designed for all types of clot. Our aim was to evaluate the efficacy and safety of the NeVaTM device for mechanical thrombectomy. METHODS: Retrospective review of prospectively collected mechanical thrombectomy database revealed 145 patients who had fullfilled the inclusion criteria. The data collected includes clinical patient characteristics, procedural measures, timestamp at each stage, and patient outcome. IV thrombolytics application, pre and post-intervention imaging findings, device related adverse event and any type of intracranial hemorrhage were recorded. RESULTS: There was female pre-dominance (54.5%). Median presenting national institutes of health stroke scale (NIHSS) was 16 (IQR, 3-32). 88 MCA-m1 (60,6%), 43 ICA-tip (29,6%), 11 MCA-m2 (7,5%), 2 ACA (1,4%) and 1 basilar (0,7%) occlusions were underwent for mechanical thrombectomy. Median procedure time was 25 min (IQR, 7-136). First-pass reperfusion scores were mTICI 0-2a 22.7%, mTICI 2b 23.4%, mTICI 2c 17.9% and mTICI 3 35.9%. Mean number of pass was 1,84 ± 1,14. Final mTICI 2b-3 score was 97.9% and TICI2c-3 score was 87.6%. No device related adverse event occurred. The mean 24-h NIHSS score was 6 (IQR 0-33). CONCLUSION: In conclusion, the NeVa thrombectomy device offers a high rate of first-pass success along with favorable safety profile. Larger series and multi-center studies are needed for further investigation.

11.
12.
J Neurosurg ; 109(3): 445-53, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18759575

RESUMO

OBJECT: The WingSpan stent is a new self-expandable neurovascular stent designed for endovascular treatment of intracranial atheromatous lesions. The authors report their experience with the use of this stent for the endovascular treatment of intracranial aneurysms. METHODS: Thirty-seven patients with 40 wide-necked intracranial aneurysms were treated using the WingSpan stent. Twenty-two aneurysms (55%) were small and 18 (45%) were large or giant. In all but 4 aneurysms, embolization was completed by packing the aneurysm sac with platinum coils. In 4 dissecting aneurysms that were fusiform or too small and wide necked to be catheterized, the stent was used alone. In these cases, the stent bridged the aneurysm neck to allow for flow redirection and the potential stent-induced endothelization effect. RESULTS: Follow-up angiograms obtained in 3 of 4 aneurysms, treated with only stent placement, demonstrated aneurysmal thrombosis and parent artery remodeling in 2 patients and moderate decrease in size in 1. Follow-up angiography obtained at 6 months to 1 year in 31 aneurysms after stent-supported coil embolization demonstrated complete occlusion in 23 aneurysms (74.2%) with a progressive thrombosis rate of 66.7% (10 of 15 aneurysms), and a recanalization rate of 16.1%. CONCLUSIONS: In treating wide-necked intracranial aneurysms, the WingSpan Stent System is very flexible, secure, and effective. Its delivery system is very easy and exact in that it exerts higher outward radial force, thus providing an excellent conformability and a strong scaffold to hold the coils in place. It may offer an effective treatment when used alone in some fusiform or very wide-necked, small dissecting aneurysms in which other surgical or endovascular treatment strategies are not deemed feasible.


Assuntos
Angioplastia , Implante de Prótese Vascular , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adolescente , Adulto , Criança , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Masculino , Pessoa de Meia-Idade , Radiografia , Fatores de Tempo , Resultado do Tratamento
14.
Diagn Interv Radiol ; 14(1): 35-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18306144

RESUMO

PURPOSE: To present our experience using the Amplatzer vascular plug in various arterial and venous systems, and follow-up results. MATERIALS AND METHODS: Between May 2005 and October 2006, 20 Amplatzer vascular plugs were used to achieve occlusion in 20 vessels in 12 patients (10 male, 2 female) aged between 24 and 80 years (mean age, 55 years). Localization and indications for embolotherapy were as follows: pulmonary arteriovenous malformations (n = 3; 9 vessels), internal iliac artery embolization before stent-graft repair for aortoiliac aneurysms (n = 4; 4 vessels), preoperative (right hemipelvectomy) embolization of bilateral internal iliac arteries (n = 1), bilateral internal iliac aneurysms (n = 1), large thoracic side branch of the left internal mammary artery coronary by-pass graft causing coronary steal syndrome (n = 1), closure of a transjugular intrahepatic portosystemic shunt (n = 1), and testicular vein embolization for a varicocele (n = 1). RESULTS: The technical success rate was 100%, with total occlusion of all the targeted vessels. Only one device was used to achieve total occlusion of the targeted vessel in all patients (device size range, 6-16 mm in diameter). No major complications occurred. Target vessel occlusion time after deployment of the Amplatzer vascular plug was 6-10 min in pulmonary arteries (mean, 7.5 min) and 10-35 min (mean, 24.4 min) in systemic arteries. Mean follow-up was 6.7 months (range, 1-18 months). CONCLUSION: Embolization with the Amplatzer vascular plug is safe, feasible, and technically simple with appropriate patient selection in various vascular territories.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Malformações Arteriovenosas/terapia , Embolização Terapêutica/instrumentação , Aneurisma Ilíaco/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/patologia , Malformações Arteriovenosas/patologia , Feminino , Humanos , Aneurisma Ilíaco/patologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
15.
J Neurosurg ; 107(1): 49-55, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17639873

RESUMO

OBJECT: Stent-assisted embolization is an alternative endovascular treatment method for wide-necked intracranial aneurysms. Currently available stents have the limitations of poor radial force, difficult delivery systems, and lack of full retrievability. The authors report on their preliminary experience with the use of a new, fully retrievable, self-expanding neurovascular stent, which has a high radial force and easy delivery system, combined with coil or Onyx embolization for the treatment of wide-necked aneurysms, including 6-month follow-up data. METHODS: Fifteen patients with 18 wide-necked intracranial aneurysms were treated using the SOLO stent system and detachable platinum coils. Aneurysms were located at the posterior communicating artery (seven lesions), midbasilar artery (one lesion), internal carotid artery (ICA) bifurcation (one lesion), ICA-ophthalmic artery segment (eight lesions), and posterior cerebral artery (one lesion). Eleven aneurysms were small, six were large, and one was giant. Only one of these aneurysms was in the acute stage of subarachnoid hemorrhage; balloon remodeling alone failed to keep the coils in the aneurysm sac. RESULTS: Only one stent required retrieving and repositioning after it had been fully deployed, and retrieval was easy and successful. No thromboembolic complication, dissection/rupture, or vasospasm occured during stent placement. Follow-up angiograms obtained at 6 months posttreatment in the 18 aneurysms demonstrated that all stents were patent with no evidence of intimal hyperplasia or stenosis. In all cases but one, 100% lesion occlusion was observed at the 6-month control angiography examination. Only one aneurysm had recanalized. CONCLUSIONS: The fully retrievable self-expandible SOLO stent is a feasible, secure, and effective system with a high radial force and ease of delivery in treating wide-necked intracranial aneurysms in combination with coil embolization.


Assuntos
Doenças das Artérias Carótidas/terapia , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico por imagem , Angiografia Coronária , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/epidemiologia , Masculino , Pessoa de Meia-Idade
16.
Diagn Interv Radiol ; 13(1): 46-8, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17354196

RESUMO

Carotid stenting has recently emerged as a potential alternative to surgical treatment. We report a case of a spontaneous rectus sheath hematoma in a patient who underwent anticoagulation therapy following carotid stenting. Computed tomography findings were consistent with active bleeding within the hematoma, and this was confirmed with selective angiography via right deep circumflex iliac artery injection. Transcatheter embolization of the right deep circumflex iliac artery with n-butyl 2-cyanoacrylate was successfully performed. To the best of our knowledge, spontaneous anterior abdominal wall hemorrhaging following carotid stenting has not been previously reported in the English language literature.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Hematoma/diagnóstico , Hematoma/terapia , Artéria Ilíaca , Stents/efeitos adversos , Músculos Abdominais/diagnóstico por imagem , Músculos Abdominais/patologia , Diagnóstico Diferencial , Embolização Terapêutica , Hematoma/diagnóstico por imagem , Hematoma/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Ultrassonografia
17.
J Neurosurg ; 105(5): 706-12, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17121131

RESUMO

OBJECT: The aim of this study was to report on a novel technique in which metallic embolization coils were combined with the Onyx liquid embolic agent in the aneurysm sac to achieve a more durable result after endovascular treatment. This therapeutic procedure was performed in selected cases in which, based on the authors' experiences, either coil embolization or Onyx alone would likely have failed. The authors report long-term clinical and angiographic follow-up results in 20 consecutive intracranial aneurysms treated using this combination for defined indications. METHODS: Twenty aneurysms in 20 patients were treated with a combination of embolic coils and Onyx. Four aneurysms were giant; 13, large; and three, small. This new technique was used when standard Onyx or coil treatment with balloon assistance was determined to involve a higher possibility of recanalization, because either an adjunctive stent insertion could not be performed or the Onyx technique could not be used due to an unsuccessful seal test or intraaneurysm balloon prolapse. In one case, an adjunctive stent was placed before coil placement and Onyx deposition to control the material in the sac of the aneurysm, which had a fusiform neck. All aneurysms were completely occluded after using this technique. No clinical or technical adverse events occurred in any of the cases. Follow-up angiography was performed in all patients: 3-year studies in six patients, 2-year studies in five, and 1-year studies in nine. None of these studies demonstrated aneurysm regrowth or parent artery occlusion. CONCLUSIONS: The combination of the embolic coils and the Onyx liquid embolic agent provides very durable aneurysm occlusion for defined indications.


Assuntos
Oclusão com Balão , Dimetil Sulfóxido/administração & dosagem , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Polivinil/administração & dosagem , Adolescente , Adulto , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Metais , Pessoa de Meia-Idade , Radiografia , Índice de Gravidade de Doença , Resultado do Tratamento
18.
Diagn Interv Radiol ; 12(4): 195-200, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17160805

RESUMO

PURPOSE: To evaluate the efficacy and safety of radiofrequency ablation (RFA) in the treatment of primary and metastatic liver malignancies. MATERIALS AND METHODS: Twenty-nine consecutive patients who have primary (n=9) and metastatic (n=20) liver malignancies were treated with RFA. The total number of lesions were 62 at the initiation of treatment and 28 new lesions were diagnosed at the follow-up period. Totally, 84 lesions were ablated with RFA technique at 46 sessions. Primary tumors that gave rise to metastatic lesion were all colorectal cancer except one with gallbladder carcinoma. The greatest tumor diameter immediately before treatment was 0.8-5 cm with a mean of 2.5 cm. RESULTS: In the hepatocellular carcinoma (HCC) group, 1 patient was lost to follow-up, 5 deceased due to extensive disease, and 3 are still on the follow-up. In the metastatic liver disease group, 8 patients died due to progression of disease, 1 deceased due to stroke, and 3 were lost to follow-up. Nine patients with HCC had 14 nodules with a mean of 1.75 lesions/patient and 20 patients had 70 metastatic lesion with a mean of 3.1 lesions/patient. Residual viable neoplastic tissue was found at control computed tomography in 1 (1/14) lesion and recurrence occurred in 3 (3/14) lesions in HCC group. Recurrence occurred in 7 lesions (7/70) of 4 patients (4/20) in the metastatic liver disease group. Drainage requiring empyema took place in 1 patient and skin burn was observed in 2 as complications due to procedure. CONCLUSION: RFA of primary and metastatic liver malignancies is a safe and effective tool for local control of disease in unresectable hepatic malignancies.


Assuntos
Ablação por Cateter/estatística & dados numéricos , Neoplasias Hepáticas/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/epidemiologia , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/patologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/epidemiologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/epidemiologia , Recidiva Local de Neoplasia/etiologia , Recidiva Local de Neoplasia/patologia , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Turquia/epidemiologia
19.
Br J Radiol ; 89(1057): 20140842, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26537690

RESUMO

OBJECTIVE: The purpose of this study was to investigate the relationship between Ki-67 proliferation indexes and apparent diffusion coefficient (ADC) values of low-grade and atypical/anaplastic (high-grade) meningiomas. METHODS: Pre-operative diffusion-weighted imaging and histopathological evaluation of 44 patients with meningiomas were performed retrospectively. Regions of interest (ROIs) were manually drawn on the ADC images. In total six ROI measurements were taken in three consecutive slices, and the average of the mean ADC value was used. The relationship between the ADC and Ki-67 values was investigated, and the ADC values of the low-grade and high-grade meningiomas were compared. RESULTS: 31 (70%) patients had low-grade the meningiomas. 10 (23%) patients had atypical and 3 (7%) had anaplastic meningiomas. ADC values of the low-grade and high-grade meningiomas were 0.81 ± 0.12 × 10(-3) and 0.66 ± 0.08 × 10(-3) mm(2) s(-1), respectively. Ki-67 proliferation indexes were 2.19% ± 1.14% for low-grade and 11.20% ± 9.80% for high-grade meningiomas. A statistically significant negative correlation between Ki-67 proliferation index and ADC values of the low-grade and high-grade meningiomas was detected (r(2) = 0.326, p < 0.001). High-grade meningiomas had lower ADC values than that of low-grade meningiomas. There was statistically significant difference between the ADC values of the low-grade and high-grade meningiomas (p < 0.001). CONCLUSION: Our data provide an inverse correlation between the ADC and Ki-67 proliferation index values of meningiomas. ADC values can be used for histopathological characterization of the meningiomas and pre-surgical planning. ADVANCES IN KNOWLEDGE: The purpose of this study was to investigate the relationship between Ki-67 proliferation indexes and ADC values of low-grade and atypical/anaplastic (high-grade) meningiomas. In addition, we compared the ADC and Ki-67 proliferative index values of the low-grade and atypical/anaplastic (high-grade) meningiomas. We concluded that there was an inverse correlation between the ADC and Ki-67 proliferation index values in meningiomas, and we have found statistically significant difference between the ADC values of the low-grade and high-grade meningiomas. ADC values can be used for histopathological characterization of the meningiomas and pre-surgical planning.


Assuntos
Biomarcadores Tumorais/análise , Proliferação de Células , Imagem de Difusão por Ressonância Magnética , Antígeno Ki-67/análise , Neoplasias Meníngeas/patologia , Meningioma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Neuroradiol J ; 27(6): 671-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25489889

RESUMO

Intracranial lipomas (ICLs) are rare lesions, the vast majority encountered as incidental findings on imaging studies. ICLs are generally pericallosal midline lesions and thought to be asymptomatic and can be accompanied by additional intracranial congenital malformations. We describe a 17-year old male with an unusual case of ICL on the frontal lobe associated with cortical dysplasia and abnormal vasculature mimicking arteriovenous malformation on magnetic resonance images.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Neoplasias Encefálicas/diagnóstico por imagem , Lobo Frontal/diagnóstico por imagem , Lipoma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Malformações do Desenvolvimento Cortical/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Malformações Arteriovenosas/complicações , Malformações Arteriovenosas/patologia , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/patologia , Lobo Frontal/patologia , Humanos , Achados Incidentais , Lipoma/complicações , Lipoma/patologia , Masculino , Malformações do Desenvolvimento Cortical/complicações , Malformações do Desenvolvimento Cortical/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA