Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 19(1): 123, 2018 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-29621971

RESUMO

BACKGROUND: Thanks to a reasonable cost and simple sample preparation procedure, linear MALDI-ToF spectrometry is a growing technology for clinical microbiology. With appropriate spectrum databases, this technology can be used for early identification of pathogens in body fluids. However, due to the low resolution of linear MALDI-ToF instruments, robust and accurate peak picking remains a challenging task. In this context we propose a new peak extraction algorithm from raw spectrum. With this method the spectrum baseline and spectrum peaks are processed jointly. The approach relies on an additive model constituted by a smooth baseline part plus a sparse peak list convolved with a known peak shape. The model is then fitted under a Gaussian noise model. The proposed method is well suited to process low resolution spectra with important baseline and unresolved peaks. RESULTS: We developed a new peak deconvolution procedure. The paper describes the method derivation and discusses some of its interpretations. The algorithm is then described in a pseudo-code form where the required optimization procedure is detailed. For synthetic data the method is compared to a more conventional approach. The new method reduces artifacts caused by the usual two-steps procedure, baseline removal then peak extraction. Finally some results on real linear MALDI-ToF spectra are provided. CONCLUSIONS: We introduced a new method for peak picking, where peak deconvolution and baseline computation are performed jointly. On simulated data we showed that this global approach performs better than a classical one where baseline and peaks are processed sequentially. A dedicated experiment has been conducted on real spectra. In this study a collection of spectra of spiked proteins were acquired and then analyzed. Better performances of the proposed method, in term of accuracy and reproductibility, have been observed and validated by an extended statistical analysis.


Assuntos
Algoritmos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Artefatos
2.
BMC Bioinformatics ; 19(1): 73, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29490628

RESUMO

BACKGROUND: In the field of biomarker validation with mass spectrometry, controlling the technical variability is a critical issue. In selected reaction monitoring (SRM) measurements, this issue provides the opportunity of using variance component analysis to distinguish various sources of variability. However, in case of unbalanced data (unequal number of observations in all factor combinations), the classical methods cannot correctly estimate the various sources of variability, particularly in presence of interaction. The present paper proposes an extension of the variance component analysis to estimate the various components of the variance, including an interaction component in case of unbalanced data. RESULTS: We applied an experimental design that uses a serial dilution to generate known relative protein concentrations and estimated these concentrations by two processing algorithms, a classical and a more recent one. The extended method allowed estimating the variances explained by the dilution and the technical process by each algorithm in an experiment with 9 proteins: L-FABP, 14.3.3 sigma, Calgi, Def.A6, Villin, Calmo, I-FABP, Peroxi-5, and S100A14. Whereas, the recent algorithm gave a higher dilution variance and a lower technical variance than the classical one in two proteins with three peptides (L-FABP and Villin), there were no significant difference between the two algorithms on all proteins. CONCLUSIONS: The extension of the variance component analysis was able to estimate correctly the variance components of protein concentration measurement in case of unbalanced design.


Assuntos
Algoritmos , Biomarcadores/análise , Espectrometria de Massas , Proteínas/análise , Análise de Variância , Ensaio de Imunoadsorção Enzimática , Humanos , Reprodutibilidade dos Testes
3.
Neural Comput ; 23(10): 2599-625, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21671785

RESUMO

We propose a new estimation method for the characterization of the Hodgkin-Huxley formalism. This method is an alternative technique to the classical estimation methods associated with voltage clamp measurements. It uses voltage clamp type recordings, but is based on the differential evolution algorithm. The parameters of an ionic channel are estimated simultaneously, such that the usual approximations of classical methods are avoided and all the parameters of the model, including the time constant, can be correctly optimized. In a second step, this new estimation technique is applied to the automated tuning of neuromimetic analog integrated circuits designed by our research group. We present a tuning example of a fast spiking neuron, which reproduces the frequency-current characteristics of the reference data, as well as the membrane voltage behavior. The final goal of this tuning is to interconnect neuromimetic chips as neural networks, with specific cellular properties, for future theoretical studies in neuroscience.


Assuntos
Algoritmos , Modelos Neurológicos , Neurônios/fisiologia , Animais , Humanos
4.
EURASIP J Bioinform Syst Biol ; 2017(1): 9, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28710702

RESUMO

This paper addresses the question of biomarker discovery in proteomics. Given clinical data regarding a list of proteins for a set of individuals, the tackled problem is to extract a short subset of proteins the concentrations of which are an indicator of the biological status (healthy or pathological). In this paper, it is formulated as a specific instance of variable selection. The originality is that the proteins are not investigated one after the other but the best partition between discriminant and non-discriminant proteins is directly sought. In this way, correlations between the proteins are intrinsically taken into account in the decision. The developed strategy is derived in a Bayesian setting, and the decision is optimal in the sense that it minimizes a global mean error. It is finally based on the posterior probabilities of the partitions. The main difficulty is to calculate these probabilities since they are based on the so-called evidence that require marginalization of all the unknown model parameters. Two models are presented that relate the status to the protein concentrations, depending whether the latter are biomarkers or not. The first model accounts for biological variabilities by assuming that the concentrations are Gaussian distributed with a mean and a covariance matrix that depend on the status only for the biomarkers. The second one is an extension that also takes into account the technical variabilities that may significantly impact the observed concentrations. The main contributions of the paper are: (1) a new Bayesian formulation of the biomarker selection problem, (2) the closed-form expression of the posterior probabilities in the noiseless case, and (3) a suitable approximated solution in the noisy case. The methods are numerically assessed and compared to the state-of-the-art methods (t test, LASSO, Battacharyya distance, FOHSIC) on synthetic and real data from proteins quantified in human serum by mass spectrometry in selected reaction monitoring mode.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA