Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Curr Oncol Rep ; 26(5): 573-582, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38625653

RESUMO

PURPOSE OF REVIEW: To review the current status of kidney tumor ablation in patients with substantial kidney impairment. RECENT FINDINGS: Few reports of kidney tumor ablation in such patients have recently been published. The reported prevalence of patients with stage 4 or 5 chronic kidney disease (CKD) among patients undergoing ablation is 2.0%-10%. In patients with stage 4 or 5 CKD, local tumor control rates were 88%-100%. The effect of ablation on CKD stage is unclear, and the observed deteriorations in kidney function are consistent with both the effect of cryoablation and the natural course of advanced CKD. According to guidelines, active surveillance may be selected. The goals of treatment are complete tumor removal and maintenance of kidney function, both of which can be met by ablation. Given the limited treatment options, ablation may play a pivotal role in the management of patients with advanced CKD.


Assuntos
Neoplasias Renais , Insuficiência Renal Crônica , Humanos , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Neoplasias Renais/complicações , Insuficiência Renal Crônica/complicações , Criocirurgia , Técnicas de Ablação/métodos
2.
J Vasc Interv Radiol ; 34(1): 31-37.e1, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36209996

RESUMO

PURPOSE: To explore what extent of ablative margin depicted by computed tomography (CT) immediately after radiofrequency (RF) ablation is required to reduce local tumor progression (LTP) for colorectal cancer (CRC) lung metastases. MATERIALS AND METHODS: This retrospective study was undertaken as a supplementary analysis of a previous prospective trial. Seventy patients (49 men and 21 women; mean age ± standard deviation, 64.9 years ± 10.6 years) underwent RF ablation for CRC lung metastases, and 95 tumors that were treated in the trial and followed up with CT at least 12 months after RF ablation were evaluated. The mean tumor size was 1.0 cm ± 0.5 cm. The ablative margin was estimated as the shortest distance between the outer edge of the tumor and the surrounding ground-glass opacity on CT obtained immediately after RF ablation. The impact of the ablative margin on LTP was evaluated using logistic regression analysis. Multivariate logistic regression analysis was also performed to identify the risk factors for LTP. The result was validated with multivariate logistic regression applying a bootstrap method (1,000 times resampling). RESULTS: The mean ablative margin was 2.7 mm ± 1.3 (range, 0.4-7.3 mm). LTP developed in 6 tumors (6%, 6/95) 6-19 months after RF ablation. The LTP rate was significantly higher when the margin was less than 2 mm (P = .023). A margin of <2 mm was also found to be a significant factor for LTP (P = .048) on multivariate analysis and validated using the bootstrap method (P = .025). CONCLUSIONS: An ablative margin of at least 2 mm is important to reduce LTP after RF ablation for CRC lung metastases.


Assuntos
Neoplasias Colorretais , Neoplasias Pulmonares , Ablação por Radiofrequência , Feminino , Humanos , Masculino , Neoplasias Colorretais/patologia , Progressão da Doença , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso
3.
Int J Clin Oncol ; 27(10): 1589-1595, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35945389

RESUMO

BACKGROUND: We prospectively evaluated the safety and efficacy of percutaneous cryoablation combined with transcatheter renal arterial embolization for the treatment of tumors ≥ 3 cm in diameter. METHODS: We included patients aged ≥ 20 years with histologically proven renal cell carcinoma with a tumor diameter ≥ 3 cm who were inoperable or refused surgery. Prior to ablation, transcatheter arterial embolization was performed using a mixture of absolute ethanol and iodized oil. All cryoablation procedures were performed percutaneously under computed tomography fluoroscopy guidance. The primary endpoint was safety, which was evaluated for adverse events using CTCAE version 4.0. The secondary endpoint was survival; overall survival, progression-free survival, and cancer-specific survival were calculated. RESULTS: From October 2013 to March 2016, 19 patients (mean age, 75 ± 13 years; 5 women, 14 men) were prospectively enrolled. The mean tumor diameter was 3.9 ± 0.7 (range 3.1-5.3) cm. Four grade 3 hematologic adverse events occurred, while no symptomatic grade ≥ 3 events occurred. The median follow-up period was 68 (range 52-84) months. During the follow-up period, two patients developed local tumor progression at 3 and 42 months after the initial ablative procedure; no patient showed distant metastasis. Two patients died from causes other than RCC. Overall survival, progression-free survival, and cause-specific survival were 100%, 95%, and 100% at 3 years, and 95%, 84%, and 100% at 5 years, respectively. CONCLUSION: Percutaneous cryoablation combined with prior TAE for the treatment of tumors ≥ 3 cm in diameter was safe and achieved favorable survival.


Assuntos
Carcinoma de Células Renais , Criocirurgia , Embolização Terapêutica , Neoplasias Renais , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/patologia , Carcinoma de Células Renais/cirurgia , Criocirurgia/métodos , Etanol , Feminino , Humanos , Óleo Iodado , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
4.
Eur Radiol ; 31(7): 5409-5420, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33449178

RESUMO

OBJECTIVES: This study aimed to assess the diagnostic accuracy of computed tomography (CT) and time-resolved magnetic resonance angiography (TR-MRA) for patency after coil embolization of pulmonary arteriovenous malformations (PAVMs) and identify factors affecting patency. METHODS: Data from the records of 205 patients with 378 untreated PAVMs were retrospectively analyzed. Differences in proportional reduction of the sac or draining vein on CT between occluded and patent PAVMs were examined, and receiver operating characteristic analysis was performed to assess the accuracy of CT using digital subtraction angiography (DSA) as the definitive diagnostic modality. The accuracy of TR-MRA was also assessed in comparison to DSA. Potential factors affecting patency, including sex, age, number of PAVMs, location of PAVMs, type of PAVM, and location of embolization, were evaluated. RESULTS: The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of CT were 82%, 81%, 77%, 85%, and 82%, respectively, when the reduction rate threshold was set to 55%, which led to the highest diagnostic accuracy. The sensitivity, specificity, PPV, NPV, and accuracy of TR-MRA were 89%, 95%, 89%, 95%, and 93%, respectively. On both univariable and multivariable analyses, embolization of the distal position to the last normal branch of the pulmonary artery was a factor that significantly affected the prevention of patency. CONCLUSIONS: TR-MRA appears to be an appropriate method for follow-up examinations due to its high accuracy for the diagnosis of patency after coil embolization of PAVMs. The location of embolization is a factor affecting patency. KEY POINTS: • Diagnosis of patency after coil embolization for pulmonary arteriovenous malformations (PAVMs) is important because a patent PAVM can lead to neurologic complications. • The diagnostic accuracies of CT with a cutoff value of 55% and TR-MRA were 82% and 93%, respectively. • The positioning of the coils relative to the sac and the last normal branch of the artery was significant for preventing PAVM patency.


Assuntos
Malformações Arteriovenosas , Embolização Terapêutica , Veias Pulmonares , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia , Humanos , Angiografia por Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
5.
Int J Clin Oncol ; 26(3): 562-568, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33174078

RESUMO

BACKGROUND: Percutaneous cryoablation is widely used for the treatment of renal cell carcinoma. We prospectively evaluated the oncologic outcomes and safety of percutaneous cryoablation for the treatment of tumors ≤ 4 cm in diameter. METHODS: We included patients aged ≥ 20 years, who had histologically proven renal cell carcinoma, tumor diameter ≤ 4 cm, a performance status of ≤ 1, acceptable laboratory parameters, were inoperable or refused to undergo surgery, and had signed a written informed consent. The primary endpoint was the cause-specific survival rate. The secondary endpoints were overall and progression-free survival, and adverse event frequency and grade. All procedures were percutaneously performed under computed tomography fluoroscopy guidance. RESULTS: From October 2013 to October 2015, 33 patients (mean age: 68 ± 14 years; sex: six women, 27 men) were enrolled. The mean tumor diameter was 2.1 ± 0.6 (range 1.0-3.4) cm. The median follow-up period was 60.1 (range 18.4-76.6) months. One patient died of non-renal cell carcinoma-related disease 46 months after percutaneous cryoablation. The cause-specific and overall survival rates were 100% and 96.8% at 3 years, and 100% and 96.8% at 5 years, respectively. There was no local tumor progression or distant metastasis. The incidence of severe urological (urinary fistula and perinephric infection) and non-urological adverse events (increased creatine kinase and skin ulceration) was 6% each. CONCLUSION: Percutaneous cryoablation for renal cell carcinoma ≤ 4 cm in diameter achieved good tumor control with a low complication frequency.


Assuntos
Carcinoma de Células Renais , Criocirurgia , Neoplasias Renais , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma de Células Renais/cirurgia , Criocirurgia/efeitos adversos , Feminino , Humanos , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
6.
Acta Med Okayama ; 75(1): 9-14, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33649608

RESUMO

To assess the feasibility of needle tract ablation in liver tissue in ex vivo and in vivo animal models using a cryo-probe and electrosurgical device. The experimental device is made by inserting a cryoprobe through an intro-ducer sheath for insulation, with 2-cm of probe tip projecting out. A beagle liver was punctured by the device, and electric current was applied at 30-W with the electrosurgical knife touching the non-insulated device base. The discolored area of cut surface along the device was evaluated in 5 application-time groups (5 , 10 , 15 , 20, or 25 seconds). An ex vivo experiment was performed to determine an ablation algorithm with an appropriate application time by comparison with radiofrequency ablation (RFA) results. Thereafter, an in vivo experiment was performed to verify the algorithm's feasibility. In the ex vivo model, the cut surface demonstrated different amounts of discolored area according to the application time. The total discolored area in the 20-seconds group was similar to that by RFA. In the in vivo model, the liver did not bleed, the total discolored area was similar to that ex vivo, and coagulation necrosis was confirmed by photomicrograph. Needle tract ablation can be per-formed using the experimental device and electrosurgical device.


Assuntos
Ablação por Cateter/métodos , Eletrocirurgia/instrumentação , Fígado/cirurgia , Animais , Cães , Feminino , Hemorragia/prevenção & controle , Fígado/patologia , Agulhas
7.
Eur Radiol ; 30(2): 927-933, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31444597

RESUMO

INTRODUCTION: This was a prospective, first-in-human trial to evaluate the feasibility and safety of insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy in humans. MATERIALS AND METHODS: Eligible patients were adults with a lesion ≥ 10 mm in an extremity or the trunk requiring pathological diagnosis with CT fluoroscopy-guided biopsy. Patients in whom at-risk structures were located within 10 mm of the scheduled needle tract were excluded. Ten patients (4 females and 6 males; mean [range] age, 72 [52-87] years) with lesions (mean [range] maximum diameter, 28 [14-52] mm) in the kidney (n = 4), lung (n = 3), mediastinum (n = 1), adrenal gland (n = 1), and muscle (n = 1) were enrolled. The biopsy procedure involved robotic insertion of a biopsy introducer needle followed by manual acquisition of specimens using a biopsy needle. The patients were followed up for 14 days. Feasibility was defined as the distance of ≤ 10 mm between needle tip after insertion and the nearest lesion edge on the CT fluoroscopic images. The safety of robotic insertion was evaluated on the basis of machine-related troubles and adverse events according to the Clavien-Dindo classification. RESULTS: Robotic insertion of the introducer needle was feasible in all patients, enabling pathological diagnosis. There was no machine-related trouble. A total of 11 adverse events occurred in 8 patients, including 10 grade I events and 1 grade IIIa event. CONCLUSION: Insertion of biopsy introducer needles with our robot was feasible at several locations in the human body. KEY POINTS: • Insertion of biopsy introducer needles with our robot during CT fluoroscopy-guided biopsy was feasible at several locations in the human body.


Assuntos
Biópsia Guiada por Imagem/métodos , Radiografia Intervencionista/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Adulto , Biópsia por Agulha/métodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia/métodos , Humanos , Biópsia Guiada por Imagem/instrumentação , Masculino , Pessoa de Meia-Idade , Agulhas , Estudos Prospectivos , Robótica/métodos , Tomografia Computadorizada por Raios X/métodos
8.
Eur Radiol ; 30(3): 1342-1349, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31773299

RESUMO

OBJECTIVES: To evaluate the accuracy of robotic CT-guided out-of-plane needle insertion in phantom and animal experiments. METHODS: A robotic system (Zerobot), developed at our institution, was used for needle insertion. In the phantom experiment, 12 robotic needle insertions into a phantom at various angles in the XY and YZ planes were performed, and the same insertions were manually performed freehand, as well as guided by a smartphone application (SmartPuncture). Angle errors were compared between the robotic and smartphone-guided manual insertions using Student's t test. In the animal experiment, 6 robotic out-of-plane needle insertions toward targets of 1.0 mm in diameter placed in the kidneys and hip muscles of swine were performed, each with and without adjustment of needle orientation based on reconstructed CT images during insertion. Distance accuracy was calculated as the distance between the needle tip and the target center. RESULTS: In the phantom experiment, the mean angle errors of the robotic, freehand manual, and smartphone-guided manual insertions were 0.4°, 7.0°, and 3.7° in the XY plane and 0.6°, 6.3°, and 0.6° in the YZ plane, respectively. Robotic insertions in the XY plane were significantly (p < 0.001) more accurate than smartphone-guided insertions. In the animal experiment, the overall mean distance accuracy of robotic insertions with and without adjustment of needle orientation was 2.5 mm and 5.0 mm, respectively. CONCLUSION: Robotic CT-guided out-of-plane needle insertions were more accurate than smartphone-guided manual insertions in the phantom and were also accurate in the in vivo procedure, particularly with adjustment during insertion. KEY POINTS: • Out-of-plane needle insertions performed using our robot were more accurate than smartphone-guided manual insertions in the phantom experiment and were also accurate in the in vivo procedure. • In the phantom experiment, the mean angle errors of the robotic and smartphone-guided manual out-of-plane needle insertions were 0.4° and 3.7° in the XY plane (p < 0.001) and 0.6° and 0.6° in the YZ plane (p = 0.65), respectively. • In the animal experiment, the overall mean distance accuracies of the robotic out-of-plane needle insertions with and without adjustments of needle orientation during insertion were 2.5 mm and 5.0 mm, respectively.


Assuntos
Rim/cirurgia , Músculo Esquelético/cirurgia , Agulhas , Imagens de Fantasmas , Punções/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Animais , Biópsia Guiada por Imagem/métodos , Rim/patologia , Músculo Esquelético/patologia , Robótica/métodos , Smartphone , Software , Cirurgia Assistida por Computador/métodos , Suínos , Tomografia Computadorizada por Raios X/métodos
9.
J Vasc Interv Radiol ; 31(7): 1044-1051, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32471699

RESUMO

PURPOSE: To retrospectively compare the outcomes of radiofrequency (RF) ablation, stereotactic body radiotherapy (SBRT), and sublobar resection (SLR) in patients with stage I non-small-cell lung cancer (NSCLC) at a single center. MATERIALS AND METHODS: Overall, 289 patients (38 RF ablation, 58 SBRT, and 193 SLR) were included. Kaplan-Meier curves were generated, multiple propensity score was estimated using a multinomial logistic regression model, and relationships between treatments and outcomes were assessed using a Cox proportional hazard model. Hazard ratios (HRs) for death from any cause and disease progression or death from any cause were examined by a crude model, an inverse probability of treatment weighting (IPTW) model, and an IPTW model adjusted for missing variables. RESULTS: The 5-year overall and progression-free survival rates were 58.9% and 39.9%, respectively, for RF ablation; 42.0% and 34.9%, respectively, for SBRT; and 85.5% and 75.9%, respectively, for SLR. Significantly longer survival time and lower HR were observed for SLR than other treatments. However, after statistical adjustment, these relationships were not significant except for reduced HR of disease progression or death from any cause of SLR compared to RF ablation in the IPTW model. The median hospital stays for RF ablation, SBRT, and SLR were 6.5, 6, and 16 days, respectively. Adverse events of grade 3 or higher occurred only in 11 SLR cases. CONCLUSIONS: SLR achieved the longest survival. However, after statistical adjustment, there were no significant outcome differences among RF ablation, SBRT, and SLR, except for 1 model. RF ablation or SBRT may be alternative treatments for selected patients with early-stage NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/terapia , Pneumonectomia , Ablação por Radiofrequência , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma Pulmonar de Células não Pequenas/patologia , Progressão da Doença , Feminino , Humanos , Japão , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Pneumonectomia/efeitos adversos , Pneumonectomia/mortalidade , Intervalo Livre de Progressão , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/mortalidade , Radiocirurgia/efeitos adversos , Radiocirurgia/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
10.
AJR Am J Roentgenol ; 214(3): 605-612, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31913072

RESUMO

OBJECTIVE. This study evaluated the utility of a deep learning method for determining whether a small (≤ 4 cm) solid renal mass was benign or malignant on multiphase contrast-enhanced CT. MATERIALS AND METHODS. This retrospective study included 1807 image sets from 168 pathologically diagnosed small (≤ 4 cm) solid renal masses with four CT phases (unenhanced, corticomedullary, nephrogenic, and excretory) in 159 patients between 2012 and 2016. Masses were classified as malignant (n = 136) or benign (n = 32). The dataset was randomly divided into five subsets: four were used for augmentation and supervised training (48,832 images), and one was used for testing (281 images). The Inception-v3 architecture convolutional neural network (CNN) model was used. The AUC for malignancy and accuracy at optimal cutoff values of output data were evaluated in six different CNN models. Multivariate logistic regression analysis was also performed. RESULTS. Malignant and benign lesions showed no significant difference of size. The AUC value of corticomedullary phase was higher than that of other phases (corticomedullary vs excretory, p = 0.022). The highest accuracy (88%) was achieved in corticomedullary phase images. Multivariate analysis revealed that the CNN model of corticomedullary phase was a significant predictor for malignancy compared with other CNN models, age, sex, and lesion size. CONCLUSION. A deep learning method with a CNN allowed acceptable differentiation of small (≤ 4 cm) solid renal masses in dynamic CT images, especially in the corticomedullary image model.


Assuntos
Aprendizado Profundo , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
Acta Med Okayama ; 74(3): 209-214, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32577018

RESUMO

An aspiration-type semi-automatic cutting biopsy needle enables tissue cutting during application of negative pressure, which is expected to contribute to a larger amount of specimen. The aim of the present study was to evaluate this novel needle in a clinical setting. Patients who underwent image-guided percutaneous biopsy for lung or renal masses were enrolled. Cutting biopsy was performed with and without aspiration during each procedure. The specimens were weighed using an electronic scale. The weights were compared between specimens obtained with and without aspiration using a paired t-test. The data from 45 lung and 30 renal biopsy procedures were analyzed. In lung biopsy, the mean±standard deviation weights of specimens obtained with and without aspiration were 2.20±1.05 mg and 2.24±1.08 mg, respectively. In renal biopsy, the mean weights were 6.52±2.18 mg and 6.42±1.62 mg, respectively. The weights were not significantly different between specimens obtained with and without aspiration either in lung (p=0.799) or renal (p=0.789) biopsies. The application of negative pressure with the aspiration-type semi-automatic cutting biopsy needle did not contribute to an increase in the amount of the specimen obtained in lung and renal biopsies.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/instrumentação , Rim/patologia , Pulmão/patologia , Idoso , Biópsia por Agulha/efeitos adversos , Estudos de Casos e Controles , Feminino , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Masculino , Memória Episódica , Pessoa de Meia-Idade , Manejo de Espécimes/métodos , Tomografia Computadorizada por Raios X
12.
Minim Invasive Ther Allied Technol ; 29(4): 217-223, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31187680

RESUMO

Purpose: To evaluate the histological findings in both tumor and surrounding non-tumoral liver parenchyma after trans-arterial chemoembolization with drug-eluting beads (DEB-TACE) for hepatocellular carcinoma (HCC) in patients who subsequently underwent hepatectomy.Material and methods: This study included six patients with an HCC (size 15-61 mm). DEB-TACE was performed using polyvinyl alcohol-based hydrogel microspheres loaded with epirubicin. Radiological tumor response was evaluated after DEB-TACE and before hepatectomy, according to the Modified Response Evaluation Criteria in Solid Tumors. Surgical specimens were histologically evaluated with hematoxylin and eosin, and elastic Van Gieson's staining.Results: Segmental, sub-segmental, or partial hepatectomy were performed 14-58 days after DEB-TACE. There was no remarkable destructive change and minimal to absent inflammatory cell infiltration in the surrounding non-tumoral liver parenchyma. There was no evidence of biliary tract or arterial wall impairment. Complete and partial histological tumor necrosis were found in three cases, respectively, in agreement with the complete and partial responses seen during the radiological evaluation.Conclusion: Histological examination of resected liver specimens after DEB-TACE showed substantial tumor necrosis without any severe inflammatory or destructive changes in the non-tumoral liver parenchyma.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Epirubicina/uso terapêutico , Neoplasias Hepáticas/terapia , Fígado/patologia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/cirurgia , Portadores de Fármacos , Epirubicina/administração & dosagem , Feminino , Hepatectomia/métodos , Humanos , Neoplasias Hepáticas/cirurgia , Masculino , Microesferas , Pessoa de Meia-Idade , Álcool de Polivinil/química , Estudos Retrospectivos , Resultado do Tratamento
13.
Eur Radiol ; 28(1): 283-290, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28770407

RESUMO

OBJECTIVES: To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. METHODS: Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. RESULTS: After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CONCLUSION: CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. KEY POINTS: • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.


Assuntos
Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Feminino , Fluoroscopia/métodos , Humanos , Biópsia Guiada por Imagem , Rim/diagnóstico por imagem , Rim/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
14.
Eur Radiol ; 28(5): 2194-2202, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29247354

RESUMO

OBJECTIVES: To retrospectively evaluate the technical success of computed tomography fluoroscopy-guided short hookwire placement before video-assisted thoracoscopic surgery and to identify the risk factors for initial placement failure. METHODS: In total, 401 short hookwire placements for 401 lesions (mean diameter 9.3 mm) were reviewed. Technical success was defined as correct positioning of the hookwire. Possible risk factors for initial placement failure (i.e., requirement for placement of an additional hookwire or to abort the attempt) were evaluated using logistic regression analysis for all procedures, and for procedures performed via the conventional route separately. RESULTS: Of the 401 initial placements, 383 were successful and 18 failed. Short hookwires were finally placed for 399 of 401 lesions (99.5%). Univariate logistic regression analyses revealed that in all 401 procedures only the transfissural approach was a significant independent predictor of initial placement failure (odds ratio, OR, 15.326; 95% confidence interval, CI, 5.429-43.267; p < 0.001) and for the 374 procedures performed via the conventional route only lesion size was a significant independent predictor of failure (OR 0.793, 95% CI 0.631-0.996; p = 0.046). CONCLUSIONS: The technical success of preoperative short hookwire placement was extremely high. The transfissural approach was a predictor initial placement failure for all procedures and small lesion size was a predictor of initial placement failure for procedures performed via the conventional route. KEY POINTS: • Technical success of preoperative short hookwire placement was extremely high. • The transfissural approach was a significant independent predictor of initial placement failure for all procedures. • Small lesion size was a significant independent predictor of initial placement failure for procedures performed via the conventional route.


Assuntos
Neoplasias Pulmonares/cirurgia , Complicações Pós-Operatórias/epidemiologia , Cuidados Pré-Operatórios/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Torácica Vídeoassistida/métodos , Idoso , Feminino , Fluoroscopia/métodos , Humanos , Japão/epidemiologia , Pulmão/diagnóstico por imagem , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X/métodos
15.
Radiology ; 285(2): 454-461, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28604237

RESUMO

Purpose To evaluate the accuracy of the remote-controlled robotic computed tomography (CT)-guided needle insertion in phantom and animal experiments. Materials and Methods In a phantom experiment, 18 robotic and manual insertions each were performed with 19-gauge needles by using CT fluoroscopic guidance for the evaluation of the equivalence of accuracy of insertion between the two groups with a 1.0-mm margin. Needle insertion time, CT fluoroscopy time, and radiation exposure were compared by using the Student t test. The animal experiments were approved by the institutional animal care and use committee. In the animal experiment, five robotic insertions each were attempted toward targets in the liver, kidneys, lungs, and hip muscle of three swine by using 19-gauge or 17-gauge needles and by using conventional CT guidance. The feasibility, safety, and accuracy of robotic insertion were evaluated. Results The mean accuracies of robotic and manual insertion in phantoms were 1.6 and 1.4 mm, respectively. The 95% confidence interval of the mean difference was -0.3 to 0.6 mm. There were no significant differences in needle insertion time, CT fluoroscopy time, or radiation exposure to the phantom between the two methods. Effective dose to the physician during robotic insertion was always 0 µSv, while that during manual insertion was 5.7 µSv on average (P < .001). Robotic insertion was feasible in the animals, with an overall mean accuracy of 3.2 mm and three minor procedure-related complications. Conclusion Robotic insertion exhibited equivalent accuracy as manual insertion in phantoms, without radiation exposure to the physician. It was also found to be accurate in an in vivo procedure in animals. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Agulhas , Radiografia Intervencionista/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Desenho de Equipamento , Imagens de Fantasmas , Radiografia Intervencionista/instrumentação , Procedimentos Cirúrgicos Robóticos/instrumentação , Suínos , Tomografia Computadorizada por Raios X/instrumentação
17.
J Vasc Interv Radiol ; 28(6): 869-876, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28366658

RESUMO

PURPOSE: To retrospectively evaluate the effect of cryoablation of renal-cell carcinoma on nearby renal cysts with the goal to investigate the potential for an alternative therapy to treat symptomatic renal cysts. MATERIALS AND METHODS: The study population comprised 46 cysts (mean size, 12 mm; range, 5-43 mm) that were within or near the ice ball during cryoablation in 22 patients. Size change of each cyst was evaluated via enhanced CT or MR imaging before and 1, 3, 6, and 12 months after cryoablation. Forty-one cysts were also followed after 12 months. Variables including positional relationship between the cyst and the ice ball were evaluated via linear regression analysis using generalized estimating equation models to determine which factors affected cyst shrinkage rate at 12 months. RESULTS: Fifteen, 12, and 19 cysts were completely included in, partially included in, or excluded from the ice ball, respectively. The overall shrinkage rate was 62%, and 57% of cysts (26 of 46) had disappeared at 12 months. Only the relationship between the cyst and the ice ball was significantly (P < .001) associated with cyst shrinkage rate. Cyst disappearance rates at 12 months were 100% (15 of 15), 67% (8 of 12), and 16% (3 of 19) for cysts completely included, partially included, and excluded from the ice ball, respectively. Among the 22 cysts that disappeared at 12 months and continued to be followed, none recurred after 12 months. CONCLUSIONS: All renal cysts that were completely included in the ice ball disappeared after cryoablation, demonstrating the potential utility of cryoablation as an alternative therapy for symptomatic renal cysts.


Assuntos
Carcinoma de Células Renais/cirurgia , Criocirurgia/métodos , Cistos/cirurgia , Neoplasias Renais/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Cistos/diagnóstico por imagem , Cistos/patologia , Feminino , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
18.
Minim Invasive Ther Allied Technol ; 26(2): 86-91, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27750475

RESUMO

PURPOSE: To retrospectively evaluate the safety and diagnostic yield of needle biopsy of small renal tumors, and the clinical consequences of performing needle biopsy in patients referred for percutaneous cryoablation before their treatment. MATERIAL AND METHODS: Biopsy was performed for 120 tumors (mean diameter, 2.2 cm) in 119 patients. All procedures were divided into diagnostic and non-diagnostic biopsies. Various variables were compared between the two groups. All cryoablation procedures were divided into two groups: procedures with or without simultaneous biopsy. The rates of benign or non-diagnostic tumors in each group were compared. RESULTS: After performing 120 initial and eight repeat biopsies, Grade 1 bleedings occurred in 44 cases. Six tumors were non-diagnostic and 114 were pathologically diagnosed. There were no significant variables between the diagnostic and non-diagnostic biopsies. Unnecessary cryoablation was avoided in nine benign lesions by performing biopsy in advance. Cryoablation performed simultaneously with biopsy included significantly more benign or non-diagnostic tumors than cryoablation performed after biopsy (15.2% vs. 1.4%; p = .01). CONCLUSIONS: Percutaneous biopsy of small renal tumors referred for cryoablation was a safe procedure with high diagnostic yield. The confirmation of pathological diagnosis prior to cryoablation is necessary because patients with benign tumors can avoid unnecessary treatment.


Assuntos
Biópsia por Agulha/métodos , Criocirurgia/métodos , Neoplasias Renais/diagnóstico , Procedimentos Desnecessários , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/efeitos adversos , Feminino , Humanos , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Eur Radiol ; 26(1): 114-21, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25991483

RESUMO

OBJECTIVES: To retrospectively evaluate the safety of computed tomography (CT) fluoroscopy-guided short hook wire placement for video-assisted thoracoscopic surgery and the risk factors for pneumothorax associated with this procedure. METHODS: We analyzed 267 short hook wire placements for 267 pulmonary lesions (mean diameter, 9.9 mm). Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for pneumothorax. RESULTS: Complications (219 grade 1 and 4 grade 2 adverse events) occurred in 196 procedures. No grade 3 or above adverse events were observed. Univariate analysis revealed increased vital capacity (odds ratio [OR], 1.518; P = 0.021), lower lobe lesion (OR, 2.343; P =0.001), solid lesion (OR, 1.845; P = 0.014), prone positioning (OR, 1.793; P = 0.021), transfissural approach (OR, 11.941; P = 0.017), and longer procedure time (OR, 1.036; P = 0.038) were significant predictors of pneumothorax. Multivariate analysis revealed only the transfissural approach (OR, 12.171; P = 0.018) and a longer procedure time (OR, 1.048; P = 0.012) as significant independent predictors. CONCLUSION: Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occurred, but all complications were minor. A transfissural approach and longer procedure time were significant independent predictors of pneumothorax. KEY POINTS: Complications related to CT fluoroscopy-guided preoperative short hook wire placement often occur. Complications are usually minor and asymptomatic. A transfissural approach and longer procedure time are significant independent predictors of pneumothorax.


Assuntos
Fluoroscopia/métodos , Pneumopatias/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Pneumotórax/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Suturas/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Japão/epidemiologia , Pneumopatias/diagnóstico por imagem , Neoplasias Pulmonares/complicações , Masculino , Pessoa de Meia-Idade , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Cuidados Pré-Operatórios/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Cirurgia Torácica Vídeoassistida , Adulto Jovem
20.
J Vasc Interv Radiol ; 27(9): 1362-1370, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27461589

RESUMO

PURPOSE: To conduct a retrospective evaluation of long-term survival after radiofrequency (RF) ablation for lung oligometastases from 5 types of primary lesions. MATERIALS AND METHODS: The study population consisted of 123 patients with lung oligometastases from colorectal cancer (CRC), non-small-cell lung cancer, hepatocellular carcinoma, esophageal cancer, and renal-cell carcinoma treated with RF ablation. Lung oligometastases were defined as 1-5 metastases confined to the lung while the primary cancer and other metastases were eradicated. Overall survival (OS) and recurrence-free survival (RFS) were estimated for the overall study population and for patients with each type of primary lesion. The OS and RFS rates were compared with those of the patients with any of the other four primary lesion types. Finally, various variables were analyzed to determine what factors influenced OS and RFS. RESULTS: The median follow-up was 45.7 months, and the 5-year OS and RFS rates for all 123 patients were 62% and 25%, respectively. The OS time for patients with metastases from CRC was significantly longer (P = .042); it was significantly shorter (P = .022) in patients with metastases from esophageal cancer. Longer disease-free interval was significantly (P = .015) associated with better OS. There was no variable significantly associated with OS and RFS on multivariate analyses. CONCLUSIONS: Data from this single-center study appear promising in terms of long-term survival after RF ablation of lung oligometastases from 5 primary lesions.


Assuntos
Ablação por Cateter , Neoplasias Pulmonares/cirurgia , Sobreviventes , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Quimioterapia Adjuvante , Intervalo Livre de Doença , Feminino , Humanos , Japão , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA