Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Anal Chem ; 2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39028702

RESUMO

One remaining handicap for spatially resolved elemental quantification in biological samples is the lack of a suitable internal standard (IS) that can be reliably measured across both calibration standards and samples. In this work, multielement quantitative intracellular imaging of cells tagged with lanthanide nanoparticles containing key lanthanides, e.g., Eu and Ho, is described using a novel strategy that uses the ratio of IS elements and LA-ICP-TOFMS analysis. To achieve this, an internal standard layer is deposited onto microscope slides containing either gelatin calibration standards or Eu- and Ho-tagged cell samples. This IS layer contains both gallium (Ga) and indium (In). Monitoring either element as an IS individually showed significant variability in intensity signal between sample or standards prepared across multiple microscope slides, which is indicative of the difficulties in producing a homogeneous film at intracellular resolution. However, normalization of the lanthanide signal to the ratio of the IS elements improved the calibration correlation coefficients from 0.9885 to 0.9971 and 0.9805 to 0.9980 for Eu and Ho, respectively, while providing a consistent signal to monitor the ablation behavior between standards and samples. By analyzing an independent quality control (QC) gelatin sample spiked with Eu and Ho, it was observed that without normalization to the IS ratio the concentrations of Eu and Ho were highly biased by approximately 20% in comparison to the expected values. Similarly, this overestimation was also observed in the lanthanide concentration distribution of the cell samples in comparison with the normalized data.

2.
Anal Chem ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684213

RESUMO

A methodology based on the use of asymmetrical flow field-flow fractionation (AF4) coupled to ICP-MS with size fraction-targeted isotope dilution analysis (IDA) has been developed, validated, and applied for the first time to determine the mass fraction of nanoscale silica (SiO2). For this purpose, 29Si-enriched SiO2 nanoparticles, to be used as an IDA spike/internal standard, were synthesized and characterized in-house. Double IDA was used to quantify an aqueous suspension of Stöber silica particles of similar characteristics to those of the 29SiO2 nanoparticle (NP) spike using a representative test material of natural Si isotopic composition as the calibrant. For fumed SiO2 NP in a highly complex food matrix, a methodology based on single IDA with AF4/ICP-MS using the same 29SiO2 NP spike was developed and validated. Relative expanded measurement uncertainties (k = 2) of 4% (double IDA) and 8% (single IDA) were achieved for nanoscale silica mass fractions of 5143 and 107 mg kg-1 in water suspension and food matrix, respectively. To assess the accuracy of AF4/ICP-IDMS for the characterization of SiO2 NP in a food matrix, standard addition measurements on samples spiked with Aerosil AF200, also in-house characterized for Si mass fraction, were undertaken, with an average recovery of 95.6 ± 4.1% (RSD, n = 3) obtained. The particle-specific IDA data obtained for both SiO2 NP-containing samples were also compared with that of post-AF4 channel external calibration using inorganic Si standards. The mass fractions obtained by IDA agreed well with those obtained by external calibration within their associated measurement uncertainties.

3.
Nanotechnology ; 35(38)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38861978

RESUMO

Biomedical analytical applications, as well as the industrial production of high-quality nano- and sub-micrometre particles, require accurate methods to quantify the absolute number concentration of particles. In this context, small-angle x-ray scattering (SAXS) is a powerful tool to determine the particle size and concentration traceable to the Système international d'unités (SI). Therefore, absolute measurements of the scattering cross-section must be performed, which require precise knowledge of all experimental parameters, such as the electron density of solvent and particles, whereas the latter is often unknown. Within the present study, novel SAXS-based approaches to determine the size distribution, density and number concentrations of sub-micron spherical silica particles with narrow size distributions and mean diameters between 160 nm and 430 nm are presented. For the first-time traceable density and number concentration measurements of silica particles are presented and current challenges in SAXS measurements such as beam-smearing, poorly known electron densities and moderately polydisperse samples are addressed. In addition, and for comparison purpose, atomic force microscopy has been used for traceable measurements of the size distribution and single particle inductively coupled plasma mass spectrometry with the dynamic mass flow approach for the accurate quantification of the number concentrations of silica particles. The possibilities and limitations of the current approaches are critically discussed in this study.

4.
Anal Bioanal Chem ; 416(11): 2835-2848, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286852

RESUMO

This work presents the first systematic comparison of selenium (Se) speciation in plasma from cancer patients treated orally with three Se compounds (sodium selenite, SS; L-selenomethionine, SeMet; or Se-methylselenocysteine, MSC) at 400 µg/day for 28 days. The primary goal was to investigate how these chemical forms of Se affect the plasma Se distribution, aiming to identify the most effective Se compound for optimal selenoprotein expression. This was achieved using methodology based on HPLC-ICP-MS after sample preparation/fractionation approaches. Measurements of total Se in plasma samples collected before and after 4 weeks of treatment showed that median total Se levels increased significantly from 89.6 to 126.4 µg kg-1 Se (p < 0.001), particularly when SeMet was administered (190.4 µg kg-1 Se). Speciation studies showed that the most critical differences between treated and baseline samples were seen for selenoprotein P (SELENOP) and selenoalbumin after administration with MSC (p = 5.8 × 10-4) and SeMet (p = 6.8 × 10-5), respectively. Notably, selenosugar-1 was detected in all low-molecular-weight plasma fractions following treatment, particularly with MSC. Two different chromatographic approaches and spiking experiments demonstrated that about 45% of that increase in SELENOP levels (to ~ 8.8 mg L-1) with SeMet is likely due to the non-specific incorporation of SeMet into the SELENOP affinity fraction. To the authors' knowledge, this has not been reported to date. Therefore, SELENOP is probably part of both the regulated (55%) and non-regulated (45%) Se pools after SeMet administration, whereas SS and MSC mainly contribute to the regulated one.


Assuntos
Neoplasias , Compostos de Selênio , Selênio , Humanos , Selenometionina , Neoplasias/tratamento farmacológico , Biomarcadores
5.
Anal Chem ; 95(5): 2757-2764, 2023 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-36701560

RESUMO

Surface-enhanced Raman scattering (SERS) is widely explored for the elucidation of underlying mechanisms behind biological processes. However, the capability of absolute quantitation of the number of nanoparticles from the SERS response remains a challenge. Here, we show for the first time the development of a new 2D quantitation model to allow calibration of the SERS response against the absolute concentration of SERS nanotags, as characterized by single particle inductively coupled plasma mass spectrometry (spICP-MS). A novel printing approach was adopted to prepare gelatin-based calibration standards containing the SERS nanotags, which consisted of gold nanoparticles and the Raman reporter 1,2-bis(4-pyridyl)ethylene. spICP-MS was used to characterize the Au mass concentration and particle number concentration of the SERS nanotags. Results from laser ablation inductively coupled plasma time-of-flight mass spectrometry imaging at a spatial resolution of 5 µm demonstrated a homogeneous distribution of the nanotags (between-line relative standard deviation < 14%) and a linear response of 197Au with increasing nanotag concentration (R2 = 0.99634) in the printed gelatin standards. The calibration standards were analyzed by SERS mapping, and different data processing approaches were evaluated. The reported calibration model was based on an "active-area" approach, classifying the pixels mapped as "active" or "inactive" and calibrating the SERS response against the total Au concentration and the particle number concentration, as characterized by spICP-MS. This novel calibration model demonstrates the potential for quantitative SERS imaging, with the capability of correlating the nanoparticle concentration to biological responses to further understand the underlying mechanisms of disease models.

6.
Anal Bioanal Chem ; 414(1): 561-573, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34272592

RESUMO

Exchangeable copper (CuEXC), mainly comprised copper (Cu) bound to albumin, has been proposed as a specific marker of Cu overload in Wilson's disease (WD). To the author's knowledge, there are no methods capable of determining reliably CuEXC to meet the requirements and challenges faced by a clinical trial. The present work describes a novel speciation strategy for the determination of the main Cu-species in human serum by anion-exchange high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC-ICP-MS). A label-free protein quantification approach was conducted where the concentration of Cu associated to the protein fraction was based on its relative peak area distribution and the total Cu concentration in the sample. Such a methodology was characterized in terms of selectivity, sensitivity, precision, and robustness. Due to the lack of speciated Cu-reference materials, protein recovery was assessed by comparison with that of species-specific (SS) isotope dilution (ID). For this, a double SS HPLC-ICP-IDMS method for Cu-albumin was developed and presented here for the first time. Three human sera (two frozen LGC8211 and ERM®-DA250a, and the lyophilised Seronorm™ Human) were analyzed using both the relative and ID quantification methods. The validated relative approach, with relative expanded uncertainties (k = 2) between 5.7 and 10.1% for Cu-albumin concentrations ranging from 112 to 455 µg kg-1 Cu, was found to be able to discriminate between healthy and WD populations in terms of Cu-albumin content. Also, using such methodology, underestimation of CuEXC by the classical EDTA/ultrafiltration method was demonstrated. The methodology developed in this work will be invaluable for quality control assessment and WD drug monitoring. This work describes a Cu-protein quantification approach for the determination of exchangeable Cu relevant to Wilson's Disease.


Assuntos
Degeneração Hepatolenticular , Biomarcadores , Cobre , Degeneração Hepatolenticular/metabolismo , Humanos , Espectrometria de Massas/métodos , Análise Espectral
7.
J Appl Toxicol ; 42(11): 1807-1821, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35701339

RESUMO

Molybdenum is an essential dietary trace element required for several critical enzyme systems. High intake is associated with toxicity in ruminants and animal studies. The proposed therapeutic use of molybdenum-based drugs poses a potential risk for accumulation through chronic administration of therapeutic doses of this element. The current experiment was designed to study the effect of daily dosing of a molybdenum compound, bis-choline tetrathiomolybdate (TTM), in Sprague Dawley rats using laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-ToF-MS) and two dosing levels of TTM for up to 3 months. To investigate if molybdenum accumulation was associated with tissue toxicity, histopathology, haematology and clinical biochemistry markers of toxicity were incorporated into the study design. There were no behavioural signs of toxicity to the rats, and no clinical or anatomic pathology was associated with treatment. The current data did show a progressive accumulation of molybdenum within the adrenal gland, kidneys, liver, spleen, brain and testes. Although this was not associated with tissue toxicity within the 3-month study design, greater exposure over a longer period of time has the potential for producing adverse pathophysiological cellular function. Tissue toxicity, as a result of local excessive accumulation of molybdenum over time, has clear implications for the therapeutic use of molybdenum in humans and demands sensitive monitoring of tissue molybdenum levels to avoid toxicity. The current study highlights the shortcomings of conventional biomonitoring approaches to detect molybdenum accumulation with the goal of avoiding molybdenum-associated toxicity.


Assuntos
Molibdênio , Oligoelementos , Administração Oral , Animais , Colina/farmacologia , Cobre/toxicidade , Humanos , Fígado , Molibdênio/toxicidade , Ratos , Ratos Sprague-Dawley
8.
Rapid Commun Mass Spectrom ; 35(20): e9177, 2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34382250

RESUMO

RATIONALE: Preparation of in-house reference materials (RMs) is an important aspect of light element stable isotope analysis. While some relevant information is available, there is as yet no clear set of guidelines available covering all aspects of in-house production and characterization of RMs. METHODS: To address this need, the experience of production of certified reference materials under accreditation to ISO 17034:2016 and ISO/IEC 17025:2017 has been distilled into guidance for production of in-house RMs that are fit-for-purpose. RESULTS: The guidance provided covers five areas: (i) planning; (ii) material considerations including preparation, packaging, and storage; (iii) measurements and assessments; (iv) value and uncertainty assignment; and (v) monitoring and use. CONCLUSIONS: In-house RMs prepared by following this guidance can be used to provide traceability to measurement results when used for normalization or for quality control and/or assurance purposes.

9.
Environ Sci Technol ; 55(3): 1527-1534, 2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33476127

RESUMO

Toxicity of methylmercury (MeHg) to wildlife and humans results from its binding to cysteine residues of proteins, forming MeHg-cysteinate (MeHgCys) complexes that hinder biological functions. MeHgCys complexes can be detoxified in vivo, yet how this occurs is unknown. We report that MeHgCys complexes are transformed into selenocysteinate [Hg(Sec)4] complexes in multiple animals from two phyla (a waterbird, freshwater fish, and earthworms) sampled in different geographical areas and contaminated by different Hg sources. In addition, high energy-resolution X-ray absorption spectroscopy (HR-XANES) and chromatography-inductively coupled plasma mass spectrometry of the waterbird liver support the binding of Hg(Sec)4 to selenoprotein P and biomineralization of Hg(Sec)4 to chemically inert nanoparticulate mercury selenide (HgSe). The results provide a foundation for understanding mercury detoxification in higher organisms and suggest that the identified MeHgCys to Hg(Sec)4 demethylation pathway is common in nature.


Assuntos
Mercúrio , Compostos de Metilmercúrio , Oligoquetos , Animais , Aves , Desmetilação , Humanos
10.
Anal Bioanal Chem ; 413(2): 331-344, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33140125

RESUMO

This work represents the first systematic speciation study of selenium (Se) in plasma from subjects participating in a pilot study for a cancer prevention trial (PRECISE). This involved supplementation of elderly British and Danish individuals with selenised yeast for 6 months and 5 years, respectively, at 100, 200, and 300 µg Se/day or placebo. Speciation data was obtained for male plasma using HPLC-ICP-MS and HPLC-ESI-MS/MS. With the proposed strategy, approximately 1.5 mL of plasma was needed to determine total Se concentration and the fractionation of Se in high molecular weight (HMW) and low molecular weight (LMW) pools, and for quantification and identification of small Se species. For the first time, Se-methyl-selenocysteine (MSC) and methyl-2-acetamido-2deoxy1-seleno-ß-D-galactopyranoside (Selenosugar-1) were structurally confirmed in plasma after supplementation with selenised yeast within the studied range. Determination of selenomethionine (SeMet) incorporated non-specifically into albumin (SeALB) was achieved by HPLC-ICP-MS after hydrolysis. By subtracting this SeMet concentration from the total Se in the HMW pool, the concentration of Se incorporated into selenoproteins was calculated. Results from the speciation analysis of the free Se metabolite fraction (5% of total plasma Se) suggest a significant increase in the percentage of Se (as SeMet plus Selenosugar-1) of up to 80% of the total Se in the LMW fraction after 6 months of supplementation. The Se distribution in the HMW fraction reflects a significant increase in SeALB with Se depletion from selenoproteins, which occurs most significantly at doses of over 100 µg Se/day after 5 years. The results of this work will inform future trial design. Graphical abstract.


Assuntos
Neoplasias/sangue , Neoplasias/prevenção & controle , Selênio/administração & dosagem , Selênio/sangue , Idoso , Fracionamento Químico , Cromatografia Líquida de Alta Pressão/métodos , Dinamarca , Suplementos Nutricionais , Enzimas/química , Humanos , Hidrólise , Masculino , Projetos Piloto , Selênio/análise , Compostos de Selênio , Selenometionina/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Análise Espectral , Espectrometria de Massas em Tandem , Reino Unido
11.
Langmuir ; 35(14): 4927-4935, 2019 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-30869903

RESUMO

Measuring the number concentration of colloidal nanoparticles (NPs) is critical for assessing reproducibility, enabling compliance with regulation, and performing risk assessments of NP-enabled products. For nanomedicines, their number concentration directly relates to their dose. However, the lack of relevant reference materials and established traceable measurement approaches make the validation of methods for NP number concentration difficult. Furthermore, commercial products often exhibit agglomeration, but guidelines for dealing with nonideal samples are scarce. We have compared the performance of five benchtop measurement methods for the measurement of colloidal number concentration in the presence of different levels of agglomeration. The methods are UV-visible spectroscopy, differential centrifugal sedimentation, dynamic light scattering, particle tracking analysis, and single-particle inductively coupled plasma mass spectrometry. We find that both ensemble and particle-by-particle methods are in close agreement for monodisperse NP samples and three methods are within 20% agreement for agglomerated samples. We discuss the sources of measurement uncertainties, including how particle agglomeration affects measurement results. This work is a first step toward validation and expansion of the toolbox of methods available for the measurement of real-world NP products.

12.
Rapid Commun Mass Spectrom ; 33(13): 1122-1136, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-30968483

RESUMO

RATIONALE: Analytical methods that can identify the source and fate of mercury and organomercury compounds are likely to be useful tools to investigate mercury in the environment. Carbon isotope ratio analysis of methylmercury (MeHg) together with mercury isotope ratios may offer a robust tool to study environmental cycling of organomercury compounds within fish tissues and other matrices. METHODS: MeHg carbon isotope ratios were determined by gas chromatography/combustion-isotope ratio mass spectrometry (GC/C-IRMS) either directly or following derivatization using sodium tetraethylborate. The effects of a normalization protocol and of derivatization on the measurement uncertainty of the methylmercury δ13 CVPDB values were investigated. RESULTS: GC/C-IRMS analysis resulted in a δ13 CVPDB value for an in-house MeHg reference material of δ13 CVPDB = -68.3 ± 7.7‰ (combined standard uncertainty, k = 1). This agreed very well with the value obtained by offline flow-injection analysis/chemical oxidation/isotope ratio mass spectrometry of δ13 CVPDB = -68.85 ± 0.17‰ (combined standard uncertainty, k = 1) although the uncertainty was substantially larger. The minimum amount of MeHg required for analysis was determined to be 20 µg. CONCLUSIONS: While the δ13 CVPDB values of MeHg can be obtained by GC/C-IRMS methods with or without derivatization, the low abundance of MeHg precludes such analyses in fish tissues unless there is substantial MeHg contamination. Environmental samples with sufficient MeHg pollution can be studied using these methods provided that the MeHg can be quantitatively extracted. The more general findings from this study regarding derivatization protocol implementation within an autosampler vial as well as measurement uncertainty associated with derivatization, normalization to reporting scales and integration are applicable to other GC/C-IRMS-based measurements.

13.
Anal Bioanal Chem ; 411(27): 7207-7220, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31515586

RESUMO

Determination of the purity of a substance traceable to the International System of Units (SI) is important for the production of reference materials affording traceability in quantitative measurements. Post-column isotope dilution using liquid chromatography-chemical oxidation-isotope ratio mass spectrometry (ID-LC-CO-IRMS) has previously been suggested as a means to determine the purity of organic compounds; however, the lack of an uncertainty budget has prevented assessment of the utility this approach until now. In this work, the previously published ID-LC-CO-IRMS methods have not only been improved by direct gravimetric determination of the mass flow of 13C-labelled spike but also a comprehensive uncertainty budget has been established. This enabled direct comparison of the well-characterised ID-LC-CO-IRMS method to quantitative nuclear magnetic resonance spectroscopy (qNMR) for purity determination using valine as the model compound. The ID-LC-CO-IRMS and qNMR methods provided results that were in agreement within the associated measurement uncertainty for the purity of a sample of valine of (97.1 ± 4.7)% and (99.64 ± 0.20)%, respectively (expanded uncertainties, k = 2). The magnitude of the measurement uncertainty for ID-LC-CO-IRMS determination of valine purity precludes the use of this method for determination of purity by direct analysis of the main component in the majority of situations; however, a mass balance approach is expected to result in significantly improved measurement uncertainty.


Assuntos
Aminoácidos/química , Cromatografia Líquida/métodos , Técnicas de Diluição do Indicador/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Espectrometria de Massas/métodos , Aminoácidos/análise , Reprodutibilidade dos Testes
14.
Sci Justice ; 59(1): 9-19, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30654973

RESUMO

Forensic application of carbon isotope ratio measurements of honey and honey protein to investigate the degree of adulteration with high fructose corn syrup or other C4 plant sugars is well established. These measurements must use methods that exhibit suitable performance criteria, particularly with regard to measurement uncertainty and traceability - low levels of adulteration can only be detected by methods that result in suitably small measurement uncertainties such that differences of 1‰ or less can be reliably detected. Inter-laboratory exercises are invaluable to assess the state-of-the art of measurement capabilities of laboratories necessary to achieve such performance criteria. National and designated metrology institutes from a number of countries recently participated in an inter-laboratory assessment (CCQM-K140) of stable carbon isotope ratio determination of bulk honey. The same sample material was distributed to a number of forensic isotope analysis laboratories that could not participate directly in the metrological comparison. The results from these studies have demonstrated that the majority of participants provided isotope delta values with acceptable performance metrics; that all participants ensured traceability of their results; and that where measurement uncertainties were reported; these were fit-for-purpose. A number of the forensic laboratories only reported precision rather than full estimates of measurement uncertainty and this was the major cause of the few instances of questionable performance metrics. Reporting of standard deviations in place of measurement uncertainties is common practice outside metrology institutes and the implications for interpretations of small differences in isotopic compositions are discussed. The results have also highlighted a number of considerations that are useful for organisers of similar inter-laboratory studies in the future.


Assuntos
Isótopos de Carbono/análise , Ciências Forenses/métodos , Mel/análise , Laboratórios , Incerteza , Internacionalidade , Reprodutibilidade dos Testes
15.
Clin Chem ; 64(9): 1296-1307, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29903874

RESUMO

BACKGROUND: Genetic testing of tumor tissue and circulating cell-free DNA for somatic variants guides patient treatment of many cancers. Such measurements will be fundamental in the future support of precision medicine. However, there are currently no primary reference measurement procedures available for nucleic acid quantification that would support translation of tests for circulating tumor DNA into routine use. METHODS: We assessed the accuracy of digital PCR (dPCR) for copy number quantification of a frequently occurring single-nucleotide variant in colorectal cancer (KRAS c.35G>A, p.Gly12Asp, from hereon termed G12D) by evaluating potential sources of uncertainty that influence dPCR measurement. RESULTS: Concentration values for samples of KRAS G12D and wild-type plasmid templates varied by <1.2-fold when measured using 5 different assays with varying detection chemistry (hydrolysis, scorpion probes, and intercalating dyes) and <1.3-fold with 4 commercial dPCR platforms. Measurement trueness of a selected dPCR assay and platform was validated by comparison with an orthogonal method (inductively coupled plasma mass spectrometry). The candidate dPCR reference measurement procedure showed linear quantification over a wide range of copies per reaction and high repeatability and interlaboratory reproducibility (CV, 2%-8% and 5%-10%, respectively). CONCLUSIONS: This work validates dPCR as an SI-traceable reference measurement procedure based on enumeration and demonstrates how it can be applied for assignment of copy number concentration and fractional abundance values to DNA reference materials in an aqueous solution. High-accuracy measurements using dPCR will support the implementation and traceable standardization of molecular diagnostic procedures needed for advancements in precision medicine.


Assuntos
Reação em Cadeia da Polimerase/métodos , Medicina de Precisão , Variações do Número de Cópias de DNA , Humanos , Espectrometria de Massas , Reprodutibilidade dos Testes
16.
Anal Bioanal Chem ; 410(3): 1029-1037, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29030672

RESUMO

Long-lived high abundance radionuclides are of increasing interest with regard to decommissioning of nuclear sites and longer term nuclear waste storage and disposal. In many cases, no routine technique is available for their measurement in nuclear waste and low-level (ng kg-1) environmental samples. Recent advances in ICP-MS technology offer attractive features for the selective and sensitive determination of a wide range of long-lived radionuclides. In this work, inductively coupled plasma-tandem mass spectrometry (ICP-MS/MS)-based methodology, suitable for accurate routine determinations of 93Zr at very low (ng kg-1) levels in the presence of high levels (µg kg-1) of the isobaric interferents 93Nb and 93Mo (often present in nuclear waste samples), is reported for the first time. Additionally, a novel and systematic strategy for method development based on the use of non-radioactive isotopes is proposed. It relies on gas-phase chemical reactions for different molecular ion formation to achieve isobaric interference removal. Using cell gas mixtures of NH3/He/H2 or H2/O2, and suitable mass shifts, the signal from the 93Nb and 93Mo isobaric interferences on 93Zr were suppressed by up to 5 orders of magnitude. The achieved limit of detection for 93Zr was 1.3 × 10-5 Bq g-1 (equivalent to 0.14 ng kg-1). The sample analysis time is 2 min, which represents a significant improvement in terms of sample throughput, compared to liquid scintillation counting methods. The method described here can be used for routine measurements of 93Zr at environmentally relevant levels. It can also be combined with radiometric techniques for use towards the standardisation of 93Zr measurements. Graphical abstract Interference-free determination of 93Zr in the presence of high concentrations of isobaric 93Mo and 93Nb by ICP-MS/MS.

17.
Anal Bioanal Chem ; 410(26): 6795-6806, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30094791

RESUMO

Fractionation data for cadmium in tobacco products, as obtained by sequential leaching of cadmium species with ICP-MS/MS analysis, and separately by X-ray absorption near edge structure (XANES) are presented here for the first time. The total amount of cadmium found in 3R4F cigarette cut tobacco was 1526 ± 42 µg kg-1, of which 5% was found in the smoke under ISO smoking conditions. XANES analysis showed that Cd in tobacco, cigarette smoke and ash was present in the + 2 oxidation state. Examination of the gas-particle partitioning of smoke cadmium suggests that Cd in mainstream smoke is best viewed as semi-volatile, existing in both particulate and gas phases. Sequential extraction of trapped tobacco smoke was carried out to get a deeper insight into the chemistry of cigarette smoke cadmium compounds. Consecutive extractions with ultrapure water, dilute (1%) nitric acid and 10% nitric acid led to extraction of a total amount of Cd which agreed with that obtained after microwave digestion of the whole sample, suggesting that cadmium was quantitatively leachable into aqueous/acidic solutions. Most Cd (~ 90% of the total Cd in the smoke condensate) was extracted into dilute nitric acid (likely as CdO, Cd(OH)2 and CdCO3) with a minor percentage (3%) extracted into water (likely as CdCl2) and in 10% nitric acid (likely as CdS). Extraction of trapped mainstream smoke with pentane, followed by ICP-MS/MS analysis, to examine the possible presence of organocadmium in 3R4F tobacco smoke, did not show the presence of organocadmium compounds above the method LOQ (2 µg kg-1), possibly due to their reactivity under the experimental conditions. The high selectivity with sufficient sensitivity achieved by ICP-MS/MS was invaluable to quantify Cd (at low µg kg-1levels) simultaneously with sulphur and chlorine in the tobacco smoke fractions of complex matrix. The cadmium chemistry in the smoke, identified in this study, is consistent with both relatively high lung absorption and DNA binding; both potentially important factors for disease progression in smokers. Graphical Abstract This paper provides quantitative fractionation data for cadmium in tobacco and smoke by using sequential leaching with ICPMS and XANES.


Assuntos
Cádmio/análise , Nicotiana/química , Fumaça/análise , Espectrometria de Massas em Tandem/métodos , Produtos do Tabaco/análise , Espectroscopia por Absorção de Raios X/métodos , Adsorção , Cloro/análise , Etanol/química , Limite de Detecção , Oxirredução , Solventes/química , Enxofre/análise
18.
Anal Chem ; 88(12): 6357-65, 2016 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-27108743

RESUMO

A novel strategy for the absolute quantification of selenium (Se) included in selenoprotein P (SEPP1), an important biomarker for human nutrition and disease, including diabetes and cancer, is presented here for the first time. It is based on the use of species-specific double isotope dilution mass spectrometry (SSIDA) in combination with HPLC-ICP-MS/MS for the determination of protein bound Se down to the peptide level in a complex plasma matrix with a total content of Se of 105.5 µg kg(-1). The method enabled the selective Se speciation analysis of human plasma samples without the need of extensive cleanup or preconcentration steps as required for traditional protein mass spectrometric approaches. To assess the method accuracy, two plasma reference materials, namely, BCR-637 and SRM1950, for which literature data and a reference value for SEPP1 have been reported, were analyzed using complementary hyphenated methods and the species-specific approach developed in this work. The Se mass fractions obtained via the isotopic ratios (78)Se/(76)Se and (82)Se/(76)Se for each of the Se-peptides, namely, ENLPSLCSUQGLR (ENL) and AEENITESCQUR (AEE) (where U is SeCys), were found to agree within 2.4%. A relative expanded combined uncertainty (k = 2) of 5.4% was achieved for a Se (as SEPP1) mass fraction of approximately 60 µg kg(-1). This work represents a systematic approach to the accurate quantitation of plasma SEPP1 at clinical levels using SSIDA quantification. Such methodology will be invaluable for the certification of reference materials and the provision of reference values to clinical measurements and clinical trials.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química , Selênio/química , Selenoproteína P/sangue , Espectrometria de Massas em Tandem/métodos , Sequência de Aminoácidos , Humanos , Técnicas de Diluição do Indicador , Isótopos/química , Limite de Detecção , Selenoproteína P/análise
19.
Anal Chem ; 87(11): 5482-5, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-25970520

RESUMO

We propose for the first time methodology for the determination of a number-based concentration of silica (SiO2) nanoparticles (NP) in biological serum using nanoparticle tracking analysis (NTA) as the online detector for asymmetric flow field-flow fractionation (AF4). The degree of selectivity offered by AF4 was found necessary to determine reliably number-based concentration of the measured NP in the complex matrix with a relative measurement error of 5.1% (as relative standard deviation, n = 3) and without chemical sample pretreatment. The simultaneous online coupling to other size and concentration detectors, such as multiangle light scattering (MALS) and ICPMS, for the measurement of the same NP suspension, was used to confirm the particle size determined with NTA and the equivalent particle number determined by AF4/NTA, respectively. The size- and number-based concentration data obtained by independent techniques were in a good agreement. The developed methodology can easily be extended to other types of particles or particle suspensions and other complex matrices provided that the particle size is above the limit of detection for NTA.


Assuntos
Técnicas de Química Analítica/métodos , Nanopartículas/análise , Soro/química , Dióxido de Silício/análise , Animais , Bovinos , Peso Molecular , Sistemas On-Line , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA