Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Clin Genet ; 94(1): 185-186, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29498415

RESUMO

Ataxia-oculomotor apraxia type 4 (AOA4) is a rare autosomal recessive neurologic disorder. The phenotype is characterized by ataxia, oculomotor apraxia, peripheral neuropathy and dystonia. AOA4 is caused by biallelic pathogenic variants in the PNKP gene encoding a polynucleotide kinase 3'-phosphatase with an important function in DNA-damage repair. By whole exome sequencing, we identified 2 variants within the PNKP gene in a 27-year-old German woman with a clinical AOA phenotype combined with a cerebellar pilocytic astrocytoma diagnosed at 23 years of age. One variant, a duplication in exon 14 resulting in the frameshift c.1253_1269dup p.(Thr424fs*49), has previously been described as pathogenic, for example, in cases of AOA4. The second variant, representing a nonsense mutation in exon 17, c.1545C>G p.(Tyr515*), has not yet been described and is predicted to cause a loss of the 7 C-terminal amino acids. This is the first description of AOA4 in a patient with central European descent. Furthermore, the occurrence of a pilocytic astrocytoma has not been described before in an AOA4 patient. Our data demonstrate compound heterozygous PNKP germline variants in a German patient with AOA4 and provide evidence for a possible link with tumor predisposition. Localization of the 2 variants in human PNKP NP_009185.2. NM_007254.3:c.1253_1269dup p.(Thr424fs*49) is predicted to cause a frameshift within the kinase domain, NM_007254.3:c.1545C>G p.(Tyr515*) is predicted to cause loss of 2 C-terminal amino acids of the kinase domain and 5 additional C-terminal amino acids.


Assuntos
Apraxias/congênito , Astrocitoma/genética , Síndrome de Cogan/genética , Enzimas Reparadoras do DNA/genética , Sequenciamento do Exoma , Heterozigoto , Fosfotransferases (Aceptor do Grupo Álcool)/genética , Alelos , Sequência de Aminoácidos , Apraxias/diagnóstico , Apraxias/genética , Astrocitoma/diagnóstico , Síndrome de Cogan/diagnóstico , Dano ao DNA , Enzimas Reparadoras do DNA/química , Éxons , Feminino , Humanos , Mutação , Linhagem , Fosfotransferases (Aceptor do Grupo Álcool)/química
2.
J Struct Biol ; 151(1): 92-105, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15946861

RESUMO

For three-dimensional (3D) structure determination of large macromolecular complexes, single-particle electron cryomicroscopy is considered the method of choice. Within this field, structure determination de novo, as opposed to refinement of known structures, still presents a major challenge, especially for macromolecules without point-group symmetry. This is primarily because of technical issues: one of these is poor image contrast, and another is the often low particle concentration and sample heterogeneity imposed by the practical limits of biochemical purification. In this work, we tested a state-of-the art 4 k x 4 k charge-coupled device (CCD) detector (TVIPS TemCam-F415) to see whether or not it can contribute to improving the image features that are especially important for structure determination de novo. The present study is therefore focused on a comparison of film and CCD detector in the acquisition of images in the low-to-medium ( approximately 10-25 A) resolution range using a 200 kV electron microscope equipped with field emission gun. For comparison, biological specimens and radiation-insensitive carbon layers were imaged under various conditions to test the image phase transmission, spatial signal-to-noise ratio, visual image quality and power-spectral signal decay for the complete image-processing chain. At all settings of the camera, the phase transmission and spectral signal-to-noise ratio were significantly better on CCD than on film in the low-to-medium resolution range. Thus, the number of particle images needed for initial structure determination is reduced and the overall quality of the initial computed 3D models is improved. However, at high resolution, film is still significantly better than the CCD camera: without binning of the CCD camera and at a magnification of 70 kx, film is better beyond 21 A resolution. With 4-fold binning of the CCD camera and at very high magnification (> 300 kx) film is still superior beyond 7 A resolution.


Assuntos
Microscopia Crioeletrônica/instrumentação , Imageamento Tridimensional/instrumentação , Microscopia Crioeletrônica/métodos , Substâncias Macromoleculares/química , Vírus do Mosaico do Tabaco/ultraestrutura , Vírion/ultraestrutura
3.
J Struct Biol ; 143(3): 219-28, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14572477

RESUMO

The technique of single-particle electron cryomicroscopy is currently making possible the 3D structure determination of large macromolecular complexes at constantly increasing levels of resolution. Work at resolution now attainable requires many thousands of individual images to be processed computationally. The most time-consuming step of the image-processing procedure is usually the iterative alignment of individual particle images against a set of reference images derived from a preliminary 3-D structure. We have developed an improved multireference alignment procedure based on interpolated cross-correlation images (corrims) that results in an approximately 8-fold acceleration of the iterative alignment steps. These corrims can be used to restrict the number of image-alignment calculations by narrowing down the set of reference images. Another improvement in alignment speed has been achieved by optimising the software and its implementation on many parallel processors. This new corrim-based refinement has been found to work well with two different alignment algorithms, the commonly used "fast alignment by separate translational/rotational searches" and "exhaustive alignment by polar coordinates."


Assuntos
Microscopia Crioeletrônica/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Microscopia Crioeletrônica/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Substâncias Macromoleculares , Tamanho da Partícula
4.
J Struct Biol ; 142(3): 392-401, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12781666

RESUMO

Three-dimensional electron cryomicroscopy of randomly oriented single particles is a method that is suitable for the determination of three-dimensional structures of macromolecular complexes at molecular resolution. However, the electron-microscopical projection images are modulated by a contrast transfer function (CTF) that prevents the calculation of three-dimensional reconstructions of biological complexes at high resolution from uncorrected images. We describe here an automated method for the accurate determination and correction of the CTF parameters defocus, twofold astigmatism and amplitude-contrast proportion from single-particle images. At the same time, the method allows the frequency-dependent signal decrease (B factor) and the non-convoluted background signal to be estimated. The method involves the classification of the power spectra of single-particle images into groups with similar CTF parameters; this is done by multivariate statistical analysis (MSA) and hierarchically ascending classification (HAC). Averaging over several power spectra generates class averages with enhanced signal-to-noise ratios. The correct CTF parameters can be deduced from these class averages by applying an iterative correlation procedure with theoretical CTF functions; they are then used to correct the raw images. Furthermore, the method enables the tilt axis of the sample holder to be determined and allows the elimination of individual poor-quality images that show high drift or charging effects.


Assuntos
Simulação por Computador , Imageamento Tridimensional , Algoritmos , Processamento de Imagem Assistida por Computador , Microscopia Eletrônica , Análise Multivariada , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA