Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Gastrointest Endosc ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38272273

RESUMO

BACKGROUND AND AIMS: Small bowel (SB) capsule endoscopy (CE) is a first line procedure for exploring the SB. Endoscopic GastroIntestinal PlacemenT (EGIPT) of SB CE is sometimes necessary. While the experience of EGIPT is large in pediatric populations, we aimed to describe the safety, efficacy and outcomes of EGIPT of SB CE in adult patients. METHODS: The international CApsule endoscopy REsearch (iCARE) group set up a retrospective multicenter study. Patients over 18 year-old who underwent EGIPT of SB CE before May 2022 were included. Data were collected from medical records and capsule recordings. The primary endpoint was the technical success rate of the EGIPT procedures. RESULTS: 630 patients were included (mean age 62.5 years old, 55.9% female) from 39,565 patients (1.6%) issued from 29 centers. EGIPT technical success was achieved in 610 procedures (96.8%). Anesthesia (moderate/deep sedation or general anesthesia) and centers with intermediate or high procedure loads were independent factors of technical success. Severe adverse events occurred in three (0.5%) patients. When technically successful, EGIPT was associated with a high SB CE completion rate (84.4%) and with a substantial diagnostic yield (61.1%). Completion rate was significantly higher when the capsule was delivered in the SB compared to when delivered in the stomach. CONCLUSION: EGIPT of SB CE is highly feasible, safe and comes with high completion rate and diagnostic yield. When indicated, it should rather be performed under anesthesia and the capsule should be delivered in the duodenum rather than in the stomach, for better SB examination outcomes.

2.
Endoscopy ; 55(1): 58-95, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36423618

RESUMO

MR1: ESGE recommends small-bowel capsule endoscopy as the first-line examination, before consideration of other endoscopic and radiological diagnostic tests for suspected small-bowel bleeding, given the excellent safety profile of capsule endoscopy, its patient tolerability, and its potential to visualize the entire small-bowel mucosa.Strong recommendation, moderate quality evidence. MR2: ESGE recommends small-bowel capsule endoscopy in patients with overt suspected small-bowel bleeding as soon as possible after the bleeding episode, ideally within 48 hours, to maximize the diagnostic and subsequent therapeutic yield.Strong recommendation, high quality evidence. MR3: ESGE does not recommend routine second-look endoscopy prior to small-bowel capsule endoscopy in patients with suspected small-bowel bleeding or iron-deficiency anemia.Strong recommendation, low quality evidence. MR4: ESGE recommends conservative management in those patients with suspected small-bowel bleeding and high quality negative small-bowel capsule endoscopy.Strong recommendation, moderate quality evidence. MR5: ESGE recommends device-assisted enteroscopy to confirm and possibly treat lesions identified by small-bowel capsule endoscopy.Strong recommendation, high quality evidence. MR6: ESGE recommends the performance of small-bowel capsule endoscopy as a first-line examination in patients with iron-deficiency anemia when small bowel evaluation is indicated.Strong recommendation, high quality evidence. MR7: ESGE recommends small-bowel capsule endoscopy in patients with suspected Crohn's disease and negative ileocolonoscopy findings as the initial diagnostic modality for investigating the small bowel, in the absence of obstructive symptoms or known bowel stenosis.Strong recommendation, high quality evidence. MR8: ESGE recommends, in patients with unremarkable or nondiagnostic findings from dedicated small-bowel cross-sectional imaging, small-bowel capsule endoscopy as a subsequent investigation if deemed likely to influence patient management.Strong recommendation, low quality evidence. MR9: ESGE recommends, in patients with established Crohn's disease, the use of a patency capsule before small-bowel capsule endoscopy to decrease the capsule retention rate.Strong recommendation, moderate quality evidence. MR10: ESGE recommends device-assisted enteroscopy (DAE) as an alternative to surgery for foreign bodies retained in the small bowel requiring retrieval in patients without acute intestinal obstruction.Strong recommendation, moderate quality evidence. MR11: ESGE recommends DAE-endoscopic retrograde cholangiopancreatography (DAE-ERCP) as a first-line endoscopic approach to treat pancreaticobiliary diseases in patients with surgically altered anatomy (except for Billroth II patients).Strong recommendation, moderate quality evidence.


Assuntos
Anemia Ferropriva , Endoscopia por Cápsula , Doença de Crohn , Enteropatias , Humanos , Anemia Ferropriva/diagnóstico , Anemia Ferropriva/etiologia , Anemia Ferropriva/terapia , Endoscopia Gastrointestinal/métodos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/terapia , Enteropatias/diagnóstico , Enteropatias/terapia
3.
Surg Endosc ; 37(10): 7658-7666, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37495849

RESUMO

BACKGROUND: Capsule endoscopy (CE) is the first-choice exploration in case of overt small bowel bleeding (SBB). An early CE is known to increase diagnostic yield, but long reading times may delay therapeutics. The study evaluates the diagnostic performance of the artificial intelligence tool TOP100 in patients with overt SBB undergoing early CE with Pillcam SB3. METHODS: Patients who underwent early CE (up to 14 days from the bleeding episode) for suspected overt SBB were included. One experienced endoscopist prospectively performed standard reading (SR) and a second blind experienced endoscopist performed a TOP100-based reading (TR). The primary endpoint was TR diagnostic accuracy for lesions with high bleeding potential (P2). RESULTS: A total of 111 patients were analyzed. The most common clinical presentation was melena (64%). CE showed angiodysplasias in 40.5% of patients (45/111). In per-patient analysis, TR showed a sensitivity of 90.48% (95% CI 82.09-95.80), specificity of 100% (95% CI 87.23-100) with a PPV of 100% (95% CI 94.01-100), NPV of 77.14% (95% CI 63.58-86.71) and diagnostic accuracy of 92.79 (86.29-96.84). At multivariate analysis, adequate intestinal cleansing was the only independent predictor of concordance between TR and SR (OR 2.909, p = 0.019). The median reading time for SR and TR was 23 min (18.0-26.8) and 1.9 min (range 1.7-2.1), respectively (p < 0.001). CONCLUSIONS: TOP100 provides a fast-reading mode for early CE in case of overt small bowel bleeding. It identifies most patients with active bleeding and angiodysplasias, aiding in the prioritization of therapeutic procedures. However, its accuracy in detecting ulcers, varices and P1 lesions seems insufficient.


Assuntos
Angiodisplasia , Endoscopia por Cápsula , Humanos , Inteligência Artificial , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Angiodisplasia/diagnóstico , Angiodisplasia/diagnóstico por imagem
4.
Dig Dis Sci ; 68(4): 1447-1454, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36104534

RESUMO

BACKGROUND: Motorized Spiral Enteroscopy (MSE) reduces procedure time and increases insertion depth into the small bowel; however, there is scarce evidence on factors affecting MSE efficacy. AIMS: To evaluate diagnostic yield and adverse events of MSE including patients with prior major abdominal surgery. METHODS: A prospective observational study was conducted on patients undergoing MSE from June 2019 to December 2021. Demographic characteristics, procedure time, depth of maximum insertion (DMI), technical success, diagnostic yield, and adverse events were collected. RESULTS: Seventy-four anterograde (54.4%) and 62 retrograde (45.6%) enteroscopies were performed in 117 patients (64 males, median age 67 years). Fifty patients (42.7%) had prior major abdominal surgery. Technical success was 91.9% for anterograde and 90.3% for retrograde route. Diagnostic yield was 71.6% and 61.3%, respectively. The median DMI was 415 cm (264-585) for anterograde and 120 cm (37-225) for retrograde enteroscopy. In patients with prior major abdominal surgery, MSE showed significantly longer small bowel insertion time (38 vs 29 min, p = 0.004), with similar diagnostic yield (61 vs 71.4%, p = 0.201) and DMI (315 vs 204 cm, p = 0.226). The overall adverse event rate was 10.3% (SAE 1.5%), with no differences related to prior abdominal surgery (p = 0.598). Patients with prior surgeries directly involving the gastrointestinal tract showed lower DMI (189 vs 374 cm, p = 0.019) with equal exploration time (37.5 vs 38 min, p = 0.642) compared to those with other abdominal surgeries. CONCLUSIONS: MSE is effective and safe in patients with major abdominal surgery, although longer procedure times were observed. A lower depth of insertion was detected in patients with gastrointestinal surgery.


Assuntos
Enteropatias , Laparoscopia , Masculino , Humanos , Idoso , Enteropatias/diagnóstico , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Estudos Prospectivos , Intestino Delgado/cirurgia , Enteroscopia de Duplo Balão/métodos
5.
Gastroenterol Hepatol ; 45(8): 605-613, 2022 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35065169

RESUMO

BACKGROUND AND AIMS: Achieving adequate bowel cleansing is of utmost importance for the efficiency of colon capsule endoscopy (CCE). However, information about predictive factors is lacking. The aim of this study was to assess the predictive factors of poor bowel cleansing in the CCE setting. METHODS: In this observational study, 126 patients who underwent CCE at two tertiary care hospitals were included between June 2017 and January 2020. Participants prepared for bowel cleansing with a 1-day clear liquid diet, a 4-L split-dose polyethylene glycol regimen and boosters with sodium phosphate, sodium amidotrizoate and meglumine amidotrizoate. Domperidone tablets and bisacodyl suppositories were administered when needed. Overall and per-segment bowel cleansing was evaluated using a CCE cleansing score. Simple and multiple logistic regression analysis were carried out to assess poor bowel cleansing and excretion rate predictors. RESULTS: Overall bowel cleansing was optimal in 53 patients (50.5%). Optimal per-segment bowel cleansing was achieved as follows: cecum (86 patients; 74.8%), transverse colon (91 patients; 81.3%), distal colon (81 patients; 75%) and rectum (64 patients; 66.7%). In the univariate analysis, elderly (OR, 1.03; 95% CI (1.01-1.076)) and constipation (OR, 3.82; 95% CI (1.50-9.71)) were associated with poor bowel cleansing. In the logistic regression analysis, constipation (OR, 3.77; 95% CI (1.43-10.0)) was associated with poor bowel cleansing. No variables were significantly associated with the CCE device excretion rate. CONCLUSION: Our results suggest that constipation is the most powerful predictor of poor bowel cleansing in the CCE setting. Tailored cleansing protocols should be recommended for these patients.


Assuntos
Bisacodil , Endoscopia por Cápsula , Idoso , Catárticos , Colo , Colonoscopia/métodos , Constipação Intestinal/etiologia , Diatrizoato de Meglumina , Domperidona , Humanos , Polietilenoglicóis , Sódio , Supositórios
6.
Gastroenterol Hepatol ; 44(2): 175-180, 2021 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33309073

RESUMO

Faecal microbiota transplantation (FMT) is an effective and safe treatment of recurrent Clostridioides difficile infection. It is essential to make every effort to perform FMT rigorously and based on scientific knowledge. Selection of the faecal microbiota donor is a key part of the process to ensure recipient safety. Protocols of action must be implemented that allow clinicians to act with the maximum guarantees and to minimise the risks of the procedure. In this regard, a multidisciplinary working group has been set up with the aim of establishing recommendations for selecting the faecal microbiota donor.


Assuntos
Seleção do Doador/normas , Transplante de Microbiota Fecal , Humanos
7.
Gastroenterol Hepatol ; 44(10): 680-686, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33259828

RESUMO

BACKGROUND: Small Bowel Capsule Endoscopy is the first-choice technique for investigating the majority of small bowel diseases. Its most common complications are related to incomplete examinations and capsule retention. There is no consensus on how patients with previous gastrointestinal surgery should receive the capsule. OBJECTIVE: The primary endpoint was to compare the rate of complete small-bowel examinations (completion rate) between oral ingestion and endoscopic delivery of the capsule. The secondary endpoint was to compare diagnostic yield and adverse events in the two groups. METHODS: A retrospective observational study was conducted in nine hospitals in Spain. Demographic data, previous surgery, indication for capsule endoscopy, intestinal transit time, diagnosis, completion rate (percentage of capsules reaching the caecum), diagnostic yield (percentage of results compatible with indication for the exam) and adverse events were collected. RESULTS: From January 2009 to May 2019 fifty-seven patients were included (39 male, mean age 66±15 years). The most common indications for the exam were "overt" (50.9%) and "occult" (35.1%) small bowel bleeding. Previous Billroth II gastrectomy and Roux-en-Y gastric bypass were present in 52.6% and 17.5% of patients respectively. The capsule was swallowed in 34 patients and placed endoscopically in 23 patients. No significant differences were observed between the oral ingestion and endoscopic delivery groups in terms of completion rate (82.4% vs. 78.3%; p=0.742), diagnostic yield (41.2% vs. 52.2%; p=0.432) or small bowel transit time (301 vs. 377min, p=0.118). No capsule retention occurred. Only one severe adverse event (anastomotic perforation) was observed in the endoscopic delivery group. CONCLUSIONS: In our case series, there were no significant differences between oral ingestion and endoscopic delivery in terms of completion rate, diagnostic yield or safety. Being less invasive, oral ingestion of the capsule should be the first-choice method in patients with previous gastrointestinal surgery.


Assuntos
Endoscopia por Cápsula , Procedimentos Cirúrgicos do Sistema Digestório , Enteropatias/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Idoso , Endoscopia por Cápsula/efeitos adversos , Endoscopia por Cápsula/estatística & dados numéricos , Ceco/diagnóstico por imagem , Deglutição , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Procedimentos Cirúrgicos do Sistema Digestório/estatística & dados numéricos , Endoscopia Gastrointestinal/efeitos adversos , Feminino , Gastrectomia , Derivação Gástrica , Hemorragia Gastrointestinal/etiologia , Trânsito Gastrointestinal , Humanos , Masculino , Estudos Retrospectivos , Espanha
8.
BMC Med ; 18(1): 255, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32943059

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) and CT colonography (CTC) are minimally invasive techniques for colorectal cancer (CRC) screening. Our objective is to compare CCE and CTC for the identification of patients with colorectal neoplasia among participants in a CRC screening programme with positive faecal immunochemical test (FIT). Primary outcome was to compare the performance of CCE and CTC in detecting patients with neoplastic lesions. METHODS: The VICOCA study is a prospective, single-centre, randomised trial conducted from March 2014 to May 2016; 662 individuals were invited and 349 were randomised to CCE or CTC before colonoscopy. Endoscopists were blinded to the results of CCE and CTC. RESULTS: Three hundred forty-nine individuals were included: 173 in the CCE group and 176 in the CTC group. Two hundred ninety individuals agreed to participate: 147 in the CCE group and 143 in the CTC group. In the intention-to-screen analysis, sensitivity, specificity and positive and negative predictive values for the identification of individuals with colorectal neoplasia were 98.1%, 76.6%, 93.7% and 92.0% in the CCE group and 64.9%, 95.7%, 96.8% and 57.7% in the CTC group. In terms of detecting significant neoplastic lesions, the sensitivity of CCE and CTC was 96.1% and 79.3%, respectively. Detection rate for advanced colorectal neoplasm was higher in the CCE group than in the CTC group (100% and 93.1%, respectively; RR = 1.07; p = 0.08). Both CCE and CTC identified all patients with cancer. CCE detected more patients with any lesion than CTC (98.6% and 81.0%, respectively; RR = 1.22; p = 0.002). CONCLUSION: Although both techniques seem to be similar in detecting patients with advanced colorectal neoplasms, CCE is more sensitive for the detection of any neoplastic lesion. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02081742 . Registered: September 16, 2013.


Assuntos
Endoscopia por Cápsula/métodos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Gastrointest Endosc ; 91(6): 1322-1327, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31981645

RESUMO

BACKGROUNDS AND AIMS: A typical capsule endoscopy (CE) case generates tens of thousands of images, with abnormalities often confined to a just few frames. Omni Mode is a novel EndoCapsule software algorithm (Olympus, Tokyo, Japan) that proposes to intelligently remove duplicate images while maintaining accuracy in lesion detection. METHODS: This prospective multicenter study took place across 9 European centers. Consecutive, unselected CE cases were read conventionally in normal mode, with every captured frame reviewed. Cases were subsequently anonymized and randomly allocated to another center where they were read using Omni Mode. Detected lesions and reading times were recorded, with findings compared between both viewing modes. The clinical significance of lesions was described according to the P classification (P0, P1, and P2). Where a discrepancy in lesion detection in either mode was found, expert blinded review at a consensus meeting was undertaken. RESULTS: The patient population undergoing CE had a mean age of 49.5 years (range, 18-91), with the investigation of anemia or GI bleeding accounting for 71.8% of cases. The average small-bowel transit time was 4 hours, 26 minutes. The mean reading time in normal mode was 42.5 minutes. The use of Omni Mode was significantly faster (P < .0001), with an average time saving of 24.6 minutes (95% confidence interval, 22.8-26.9). The 2127 lesions were identified and classified according to the P classification as P0 (1234), P1 (656), and P2 (237). Lesions were identified using both reading modes in 40% (n = 936), and 1186 lesions were identified by either normal or Omni Mode alone. Normal mode interpretation was associated with 647 lesions being missed, giving an accuracy of .70. Omni Mode interpretation led to 539 lesions being missed, with an accuracy of .75. There was no significant difference in clinical conclusions made between either reading mode. CONCLUSIONS: This study shows that CE reading times can be reduced by an average of 40%, without any reduction in clinical accuracy.


Assuntos
Endoscopia por Cápsula , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Japão , Pessoa de Meia-Idade , Estudos Prospectivos , Leitura , Software , Adulto Jovem
10.
Rev Esp Enferm Dig ; 112(4): 331, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32216445

RESUMO

The novel motorized spiral rnteroscope (PowerSpiral®, Olympus) (PSE) has been recently commercialized with promising results in relation to insertion depth and time of exploration. We herewith report our first case of a total small bowel exploration with PSE.


Assuntos
Enteropatias , Laparoscopia , Endoscópios Gastrointestinais , Endoscopia Gastrointestinal , Humanos , Enteropatias/cirurgia , Intestino Delgado/diagnóstico por imagem
11.
Rev Esp Enferm Dig ; 112(4): 284-289, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32216446

RESUMO

INTRODUCTION: there is very little scientific evidence about the efficacy of endoscopic balloon dilation (EBD) performed with balloon-assisted enteroscopy (BAE) for the treatment of small bowel strictures (SBS) in Crohn's disease (CD). OBJECTIVE: to evaluate the efficacy and safety of EBD using BAE in patients with CD and SBS. METHODS: a retrospective observational study was performed in a tertiary care medical center in patients with CD and SBS, evaluated by CT enterography or MRI enterography. RESULTS: from 2009 to 2019, 205 endoscopic dilations were performed in 80 patients with CD. 17 (21.25 %) had only SBS and 70.6 % were male with a median age of 42.2 (±14.4) years. The mean follow-up was 37.8 ±28.7 months. A total of 39 dilations were performed, 94.1 % were native and less than 5cm long, all strictures were ulcerated. The overall technical success was 82.4 % and clinical success was 88.2 %. During follow-up, 23.5 % of patients required surgery and 29.4 % were re-dilated. The long-term efficacy was 76.5 % and no severe adverse events (AE) were observed. No factors were identified to predict the need for surgery after dilation. CONCLUSIONS: SBS can be safely and effectively treated with EBD using BAE, thus reducing the need for surgery in the long term.


Assuntos
Doença de Crohn , Obstrução Intestinal , Adulto , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Dilatação , Endoscopia Gastrointestinal , Humanos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
12.
Rev Esp Enferm Dig ; 112(4): 309-318, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32188259

RESUMO

The present evidence-based guidelines are focused on the use of device-assisted enteroscopy in the management of small-bowel diseases. A panel of experts selected by the Spanish and Portuguese small-bowel study groups reviewed the available evidence focusing on the main indications of this technique, its role in the management algorithm of each indication, and its diagnostic and therapeutic yield. A set of recommendations was issued accordingly.


Assuntos
Endoscopia por Cápsula , Enteropatias , Humanos , Enteropatias/diagnóstico por imagem , Enteropatias/terapia , Intestino Delgado/diagnóstico por imagem , Portugal
13.
Gastroenterol Hepatol ; 43(10): 589-597, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32674879

RESUMO

INTRODUCTION: In a previous study we demonstrated that a simple training programme improved quality indicators of Oesophagogastroduodenoscopy (OGD) achieving the recommended benchmarks. However, the long-term effect of this intervention is unknown. The aim of this study was to assess the quality of OGDs performed 3 years after of having completed a training programme. MATERIAL AND METHODS: A comparative study of 2 cohorts was designed as follows: Group A included OGDs performed in 2016 promptly after a training programme and Group B with OGDs performed from January to March 2019, this group was also divided into 2 subgroups: subgroup B1 of Endoscopists who had participated in the previous training programme and subgroup B2 of Endoscopists who had not. The intra-procedure quality indicators proposed by ASGE-ACG were used. RESULTS: A total of 1236 OGDs were analysed, 600 from Group A and 636 from Group B (439 subgroup B1 and 197 subgroup B2). The number of complete examinations was lower in Group B (566 [94.3%] vs. 551 [86.6%]; p<0.001). A significant decrease was observed in nearly all quality indicators and they did not reach the recommended benchmarks: retroflexion in the stomach (96% vs. 81%; p<0.001); Seattle biopsy protocol (86% vs. 50%; p=0.03), description of the upper GI bleeding lesion (100% vs. 62%; p<0.01), sufficient intestinal biopsy specimens (at least 4) in suspected coeliac disease (92.5% vs. 18%; p<0.001), photo documentation of the lesion (94% vs. 90%; p<0.05). Regarding the overall assessment of the procedure (including correct performance and adequate photo documentation), a significant decrease was also observed (90.5% vs. 62%; p<0.001). There were no differences between subgroups B1 and B2. CONCLUSIONS: The improvement observed in 2016 after a training programme did not prevail after 3 years. In order to keep the quality of OGDs above the recommended benchmarks, it is necessary to implement continuous training programmes.


Assuntos
Benchmarking , Duodenoscopia/normas , Esofagoscopia/normas , Gastroscopia/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Biópsia/normas , Doença Celíaca/patologia , Estudos de Coortes , Duodenoscopia/educação , Duodenoscopia/estatística & dados numéricos , Esofagoscopia/educação , Esofagoscopia/estatística & dados numéricos , Hemorragia Gastrointestinal/diagnóstico por imagem , Gastroscopia/educação , Gastroscopia/estatística & dados numéricos , Humanos , Intestinos/patologia , Fotografação , Desenvolvimento de Programas , Padrões de Referência , Sociedades Médicas , Fatores de Tempo
16.
Gastrointest Endosc ; 90(3): 461-466, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108089

RESUMO

BACKGROUND AND AIMS: Helicobacter pylori is the major cause of gastritis and gastritis-associated diseases. Detection of a regular arrangement of collecting venules (RAC) in the lesser gastric curvature correlates with negative H pylori status with a sensitivity and negative predictive value (NPV) higher than 90% in Asian countries. The aim of the study was to evaluate the value of RAC as a diagnostic method of H pylori infection in a European population. METHODS: A prospective study with high-definition endoscopes without magnification was performed by 3 endoscopists. The presence of starfish-like minute points regularly distributed throughout the lesser curvature of the gastric body was considered RAC positive (RAC+). Gastric biopsies were performed during the procedure for H pylori diagnosis. RESULTS: One hundred forty patients were included from February 2017 to May 2018. The prevalence of H pylori infection was 31% and 47 of 140 patients (34%) were RAC+; 13 of 23 patients in whom H pylori was eradicated were RAC+. The mean age of RAC+ patients was lower (44.4 vs 52.4 years, P = .004) and they had less- significant endoscopic findings (9; 19.1% vs 38; 80.9%; P = .017). Gender, use of nonsteroidal anti-inflammatory drugs, antithrombotic or anticoagulants treatments, and a history of H pylori eradication did not show differences in the RAC pattern. The absence of RAC was associated with H pylori infection in 47.3% (44/93) of cases. In contrast, all RAC+ patients were free of H pylori infection, with sensitivity and NPV of 100% for the exclusion of H pylori infection. CONCLUSION: The presence of RAC+ in the lesser curvature evaluated with high-definition endoscopy can accurately identify patients without H pylori.


Assuntos
Gastroscopia , Infecções por Helicobacter/diagnóstico , Estômago/patologia , Vênulas/patologia , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Infecções por Helicobacter/patologia , Helicobacter pylori , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estômago/irrigação sanguínea , Adulto Jovem
18.
Dig Endosc ; 30(4): 461-466, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29253321

RESUMO

BACKGROUND AND AIM: The role of capsule endoscopy (CE) in established celiac disease (CD) remains unclear. Our objective was to analyze the usefulness of CE in the suspicion of complicated CD. METHODS: This was a retrospective multicenter study. One hundred and eighty-nine celiac patients (mean age: 46.6 ± 16.6, 30.2% males) who underwent CE for alarm symptoms (n = 86, 45.5%) or non-responsive CD (n = 103, 54.5%) were included. Diagnostic yield (DY), therapeutic impact and safety were analyzed. RESULTS: Capsule endoscopy was completed in 95.2% of patients (small bowel transit time: 270.5 ± 100.2 min). Global DY was 67.2%, detecting atrophic mucosa (n = 92, 48.7%), ulcerative jejunoileitis (n = 21, 11.1%), intestinal lymphoma (n = 7, 3.7%) and other enteropathies (n = 7, 3.7%, six Crohn's disease cases and one neuroendocrine tumor). The DY of CE was significantly higher in patients presenting with non-responsive disease compared to patients with alarm symptoms (73.8% vs 59.3%, P = 0.035). The new findings of the CE modified management in 59.3% of the cases. There were no major complications. CONCLUSION: Capsule endoscopy may be a moderately helpful and safe diagnostic tool in the suspicion of complicated CD, modifying the clinical course of these patients.


Assuntos
Endoscopia por Cápsula/métodos , Doença Celíaca/diagnóstico , Dieta Livre de Glúten , Mucosa Intestinal/patologia , Adulto , Doença Celíaca/dietoterapia , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Humanos , Intestino Delgado/patologia , Intestino Delgado/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Adulto Jovem
19.
Rev Esp Enferm Dig ; 110(3): 179-194, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29421912

RESUMO

This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions.


Assuntos
Neoplasias Colorretais/cirurgia , Cirurgia Colorretal/métodos , Ressecção Endoscópica de Mucosa/métodos , Endoscopia Gastrointestinal/métodos , Mucosa Intestinal/cirurgia , Doenças do Colo/cirurgia , Cirurgia Colorretal/normas , Ressecção Endoscópica de Mucosa/normas , Endoscopia Gastrointestinal/normas , Humanos , Doenças Retais/cirurgia
20.
Gastroenterol Hepatol ; 41(3): 175-190, 2018 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29449039

RESUMO

This document summarizes the contents of the Clinical Guidelines for the Endoscopic Mucosal Resection of Non-Pedunculated Colorectal Lesions that was developed by the working group of the Spanish Society of Digestive Endoscopy (GSEED of Endoscopic Resection). This document presents recommendations for the endoscopic management of superficial colorectal neoplastic lesions.


Assuntos
Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/normas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA