RESUMO

BACKGROUND: Cardiac and major vascular surgeries are common surgical procedures associated with high rates of postsurgical complications and related hospital readmission. In-hospital remote automated monitoring (RAM) and virtual hospital-to-home patient care systems have major potential to improve patient outcomes following cardiac and major vascular surgery. However, the science of deploying and evaluating these systems is complex and subject to risk of implementation failure. OBJECTIVE: As a precursor to a randomized controlled trial (RCT), this user testing study aimed to examine user performance and acceptance of a RAM and virtual hospital-to-home care intervention, using Philip's Guardian and Electronic Transition to Ambulatory Care (eTrAC) technologies, respectively. METHODS: Nurses and patients participated in systems training and individual case-based user testing at two participating sites in Canada and the United Kingdom. Participants were video recorded and asked to think aloud while completing required user tasks and while being rated on user performance. Feedback was also solicited about the user experience, including user satisfaction and acceptance, through use of the Net Promoter Scale (NPS) survey and debrief interviews. RESULTS: A total of 37 participants (26 nurses and 11 patients) completed user testing. The majority of nurse and patient participants were able to complete most required tasks independently, demonstrating comprehension and retention of required Guardian and eTrAC system workflows. Tasks which required additional prompting by the facilitator, for some, were related to the use of system features that enable continuous transmission of patient vital signs (eg, pairing wireless sensors to the patient) and assigning remote patient monitoring protocols. NPS scores by user group (nurses using Guardian: mean 8.8, SD 0.89; nurses using eTrAC: mean 7.7, SD 1.4; patients using eTrAC: mean 9.2, SD 0.75), overall NPS scores, and participant debrief interviews indicated nurse and patient satisfaction and acceptance of the Guardian and eTrAC systems. Both user groups stressed the need for additional opportunities to practice in order to become comfortable and proficient in the use of these systems. CONCLUSIONS: User testing indicated a high degree of user acceptance of Philips' Guardian and eTrAC systems among nurses and patients. Key insights were provided that informed refinement of clinical workflow training and systems implementation. These results were used to optimize workflows before the launch of an international RCT of in-hospital RAM and virtual hospital-to-home care for patients undergoing cardiac and major vascular surgery.


Assuntos
Doenças Cardiovasculares/cirurgia , Serviços de Assistência Domiciliar/normas , Hospitais/normas , Monitorização Fisiológica/métodos , Interface Usuário-Computador , Idoso , Feminino , Humanos , Masculino , Período Pós-Operatório
2.
JMIR Mhealth Uhealth ; 10(2): e24916, 2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-34876396

RESUMO

BACKGROUND: Wearable continuous monitoring biosensor technologies have the potential to transform postoperative care with early detection of impending clinical deterioration. OBJECTIVE: Our aim was to validate the accuracy of Cloud DX Vitaliti continuous vital signs monitor (CVSM) continuous noninvasive blood pressure (cNIBP) measurements in postsurgical patients. A secondary aim was to examine user acceptance of the Vitaliti CVSM with respect to comfort, ease of application, sustainability of positioning, and aesthetics. METHODS: Included participants were ≥18 years old and recovering from surgery in a cardiac intensive care unit (ICU). We targeted a maximum recruitment of 80 participants for verification and acceptance testing. We also oversampled to minimize the effect of unforeseen interruptions and other challenges to the study. Validation procedures were according to the International Standards Organization (ISO) 81060-2:2018 standards for wearable, cuffless blood pressure (BP) measuring devices. Baseline BP was determined from the gold-standard ICU arterial catheter. The Vitaliti CVSM was calibrated against the reference arterial catheter. In static (seated in bed) and supine positions, 3 cNIBP measurements, each 30 seconds, were taken for each patient with the Vitaliti CVSM and an invasive arterial catheter. At the conclusion of each test session, captured cNIBP measurements were extracted using MediCollector BEDSIDE data extraction software, and Vitaliti CVSM measurements were extracted to a secure laptop through a cable connection. The errors of these determinations were calculated. Participants were interviewed about device acceptability. RESULTS: The validation analysis included data for 20 patients. The average times from calibration to first measurement in the static position and to first measurement in the supine position were 133.85 seconds (2 minutes 14 seconds) and 535.15 seconds (8 minutes 55 seconds), respectively. The overall mean errors of determination for the static position were -0.621 (SD 4.640) mm Hg for systolic blood pressure (SBP) and 0.457 (SD 1.675) mm Hg for diastolic blood pressure (DBP). Errors of determination were slightly higher for the supine position, at 2.722 (SD 5.207) mm Hg for SBP and 2.650 (SD 3.221) mm Hg for DBP. The majority rated the Vitaliti CVSM as comfortable. This study was limited to evaluation of the device during a very short validation period after calibration (ie, that commenced within 2 minutes after calibration and lasted for a short duration of time). CONCLUSIONS: We found that the Cloud DX's Vitaliti CVSM demonstrated cNIBP measurement in compliance with ISO 81060-2:2018 standards in the context of evaluation that commenced within 2 minutes of device calibration; this device was also well-received by patients in a postsurgical ICU setting. Future studies will examine the accuracy of the Vitaliti CVSM in ambulatory contexts, with attention to assessment over a longer duration and the impact of excessive patient motion on data artifacts and signal quality. TRIAL REGISTRATION: ClinicalTrials.gov NCT03493867; https://clinicaltrials.gov/ct2/show/NCT03493867.


Assuntos
Determinação da Pressão Arterial , Dispositivos Eletrônicos Vestíveis , Adolescente , Pressão Sanguínea/fisiologia , Humanos , Monitorização Fisiológica
3.
Can J Cardiol ; 34(7): 850-862, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29960614

RESUMO

Worldwide, more than 230 million adults have major noncardiac surgery each year. Although surgery can improve quality and duration of life, it can also precipitate major complications. Moreover, a substantial proportion of deaths occur after discharge. Current systems for monitoring patients postoperatively, on surgical wards and after transition to home, are inadequate. On the surgical ward, vital signs evaluation usually occurs only every 4-8 hours. Reduced in-hospital ward monitoring, followed by no vital signs monitoring at home, leads to thousands of cases of undetected/delayed detection of hemodynamic compromise. In this article we review work to date on postoperative remote automated monitoring on surgical wards and strategy for advancing this field. Key considerations for overcoming current barriers to implementing remote automated monitoring in Canada are also presented.


Assuntos
Monitorização Fisiológica/métodos , Cuidados Pós-Operatórios/métodos , Procedimentos Cirúrgicos Operatórios , Telemedicina/métodos , Sinais Vitais/fisiologia , Humanos
4.
JMIR Res Protoc ; 5(3): e149, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27480247

RESUMO

BACKGROUND: Tens of thousands of cardiac and vascular surgeries (CaVS) are performed on seniors in Canada and the United Kingdom each year to improve survival, relieve disease symptoms, and improve health-related quality of life (HRQL). However, chronic postsurgical pain (CPSP), undetected or delayed detection of hemodynamic compromise, complications, and related poor functional status are major problems for substantial numbers of patients during the recovery process. To tackle this problem, we aim to refine and test the effectiveness of an eHealth-enabled service delivery intervention, TecHnology-Enabled remote monitoring and Self-MAnagemenT-VIsion for patient EmpoWerment following Cardiac and VasculaR surgery (THE SMArTVIEW, CoVeRed), which combines remote monitoring, education, and self-management training to optimize recovery outcomes and experience of seniors undergoing CaVS in Canada and the United Kingdom. OBJECTIVE: Our objectives are to (1) refine SMArTVIEW via high-fidelity user testing and (2) examine the effectiveness of SMArTVIEW via a randomized controlled trial (RCT). METHODS: CaVS patients and clinicians will engage in two cycles of focus groups and usability testing at each site; feedback will be elicited about expectations and experience of SMArTVIEW, in context. The data will be used to refine the SMArTVIEW eHealth delivery program. Upon transfer to the surgical ward (ie, post-intensive care unit [ICU]), 256 CaVS patients will be reassessed postoperatively and randomly allocated via an interactive Web randomization system to the intervention group or usual care. The SMArTVIEW intervention will run from surgical ward day 2 until 8 weeks following surgery. Outcome assessments will occur on postoperative day 30; at week 8; and at 3, 6, 9, and 12 months. The primary outcome is worst postop pain intensity upon movement in the previous 24 hours (Brief Pain Inventory-Short Form), averaged across the previous 14 days. Secondary outcomes include a composite of postoperative complications related to hemodynamic compromise-death, myocardial infarction, and nonfatal stroke- all-cause mortality and surgical site infections, functional status (Medical Outcomes Study Short Form-12), depressive symptoms (Geriatric Depression Scale), health service utilization-related costs (health service utilization data from the Institute for Clinical Evaluative Sciences data repository), and patient-level cost of recovery (Ambulatory Home Care Record). A linear mixed model will be used to assess the effects of the intervention on the primary outcome, with an a priori contrast of weekly average worst pain intensity upon movement to evaluate the primary endpoint of pain at 8 weeks postoperation. We will also examine the incremental cost of the intervention compared to usual care using a regression model to estimate the difference in expected health care costs between groups. RESULTS: Study start-up is underway and usability testing is scheduled to begin in the fall of 2016. CONCLUSIONS: Given our experience, dedicated industry partners, and related RCT infrastructure, we are confident we can make a lasting contribution to improving the care of seniors who undergo CaVS.

5.
Toxicol Lett ; 221(3): 191-6, 2013 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-23827506

RESUMO

The present study examined the dose related effects of low levels of the toxin, LiCl, on the ingestion of a palatable sucrose plus salt solution. Over five days (acquisition phase) rats were presented with a 0.3M sucrose solution containing one of the following salt combinations: 0.12 M NaCl (n=10 negative control group); 0.005 M LiCl+0.115 NaCl (n=10); 0.01 M LiCl+0.11 NaCl (n=10); 0.015 M LiCl+0.105 M NaCl (n=10); 0.02 M LiCl+0.10 M NaCl (n=10); and 0.12 M LiCl (n=8 positive control group). During an extinction phase (5 days), all rats were presented with 0.3M Sucrose+0.12 M NaCl solution. Fluid intake levels and number of licks were quantified on each day. At low LiCl concentration levels rats exhibited a dose related reduction in amount consumed and number of licks of the sucrose plus salt solutions. This toxin related suppression of fluid intake and licking rapidly dissipated during the extinction phase. The present findings support the hypothesis that rats use a behavioral tolerance mechanism to regulate their intake of foods containing low levels of toxins.


Assuntos
Aprendizagem da Esquiva/efeitos dos fármacos , Ingestão de Líquidos/efeitos dos fármacos , Cloreto de Lítio/toxicidade , Animais , Relação Dose-Resposta a Droga , Cloreto de Lítio/administração & dosagem , Masculino , Distribuição Aleatória , Ratos , Ratos Long-Evans