Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Curr Oncol ; 28(6): 5155-5166, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34940071

RESUMO

Prognostic factors have important utility in various aspects of cancer surveillance, including research, patient care, and cancer control programmes. Nevertheless, there is heterogeneity in the collection of prognostic factors and outcomes data globally. This study aimed to investigate perspectives on the utility and application of prognostic factors and clinical outcomes in cancer control programmes. A qualitative phenomenology approach using expert interviews was taken to derive a rich description of the current state and future outlook of cancer prognostic factors and clinical outcomes. Individuals with expertise in this work and from various regions and institutions were invited to take part in one-on-one semi-structured interviews. Four areas related to infrastructure and funding challenges were identified by participants, including (1) data collection and access; (2) variability in data reporting, coding, and definitions; (3) limited coordination among databases; and (4) conceptualization and prioritization of meaningful prognostic factors and outcomes. Two areas were identified regarding important future priorities for cancer control: (1) global investment and intention in cancer surveillance and (2) data governance and exchange globally. Participants emphasized the need for better global collection of prognostic factors and clinical outcomes data and support for standardized data collection and data exchange practices by cancer registries.


Assuntos
Projetos de Pesquisa , Coleta de Dados , Humanos , Prognóstico , Sistema de Registros
2.
Radiother Oncol ; 70(1): 37-44, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15036850

RESUMO

BACKGROUND AND PURPOSE: The optimal treatment position for patients receiving radical radiation therapy for prostate cancer has been a source of controversy. To resolve this issue, we conducted a randomized trial to evaluate the effects of supine and prone positioning on organ motion, positioning errors, and dose to critical organs during escalated dose conformal irradiation for localized prostate cancer and patient and therapist satisfaction with setup technique. PATIENTS AND METHODS: Twenty eight patients were randomized to commence treatment immobilized in the supine or prone position and were subsequently changed to the alternate positioning for the latter half of their treatment. Patients underwent CT simulation and conformal radiotherapy planning and treatment in both positions. The clinical target volume encompassed the prostate gland. Alternate day lateral port films were compared to corresponding simulator radiographs to measure the isocentre positioning errors (IPE). Prostate motion (PM) and total positioning error (TPE) were measured from the same films by the displacements of three implanted fiducial markers. Dose volume histograms (DVHs) for the two treatment positions were compared at the 95, 80 and 50% dose (D%) levels. The patients and radiation therapists completed weekly questionnaires regarding patient comfort and ease of setup. RESULTS: Seven patients, who started in the supine position, subsequently refused prone position and received their whole treatment supine. Small bowel in the treatment volume, not present in the supine position, prevented one patient from being treated prone. PM in anterior posterior direction was statistically significantly less in the supine position (P<0.05). There was no significant difference in superior inferior PM for the two treatment positions. No statistically significant difference between supine and prone positioning was observed in isocentre positioning error (IPE) or total positioning error (TPE) due to a policy of daily pre-treatment correction. However, more pre-treatment corrections were required for patients in the prone position. The DVH analysis demonstrated larger volumes of the bladder wall, rectal wall and small bowel within the D95, D80 and D50% when comparing the planning target volumes (PTVs) actually treated for prone positioning. When the prone PTV was expanded to account for the greater PM encountered in that position, a statistically significant difference (P<0.007) was observed in favour of the supine position at all dose levels. In the prone position, four patients had small bowel within the 60 Gray (Gy) isodose and in the supine position, no patients had small bowel in the 60 or 38Gy volumes. Supine position was significantly more comfortable for the patients and setup was significantly easier for the radiation therapists. The median patient comfort score was 0.79 (Standard deviation (SD) 0.03) supine and 0.45 (SD 0.05) prone (P<0.001) The therapist convenience of setup was 0.80 (SD 0.016) supine and 0.54 (SD 0.025) prone (P<0.005). No statistically significant difference was seen for the other parameters studied. CONCLUSIONS: We demonstrated significantly less PM in the supine treatment position. There was no difference for either treatment position in IPE or TPE, however, more pre-treatment corrections were required in the prone position. Prone position required a larger PTV with resulting increased dose to critical organs. There were statistically significant improvements at all dose levels for small bowel, rectal wall and bladder wall doses in the supine position once corrections were made for differences in organ motion. Linear analogue scores of patient comfort and radiation therapist convenience demonstrated statistically significant improvement in favour of the supine position. Supine positioning has been adopted as the standard for conformal prostatic irradiation at our centre.


Assuntos
Decúbito Ventral , Neoplasias da Próstata/radioterapia , Radioterapia Conformacional/métodos , Decúbito Dorsal , Idoso , Relação Dose-Resposta à Radiação , Humanos , Masculino , Satisfação do Paciente , Reto/efeitos da radiação , Resultado do Tratamento , Bexiga Urinária/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA