1.
Circulation ; 148(18): 1354-1367, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37638389

RESUMO

BACKGROUND: The circuit boundaries for reentrant ventricular tachycardia (VT) have been historically conceptualized within a 2-dimensional (2D) construct, with their fixed or functional nature unresolved. This study aimed to examine the correlation between localized lines of conduction block (LOB) evident during baseline rhythm with lateral isthmus boundaries that 3-dimensionally constrain the VT isthmus as a hyperboloid structure. METHODS: A total of 175 VT activation maps were correlated with isochronal late activation maps during baseline rhythm in 106 patients who underwent catheter ablation for scar-related VT from 3 centers (42% nonischemic cardiomyopathy). An overt LOB was defined by a deceleration zone with split potentials (≥20 ms isoelectric segment) during baseline rhythm. A novel application of pacing within deceleration zone (≥600 ms) was implemented to unmask a concealed LOB not evident during baseline rhythm. LOB identified during baseline rhythm or pacing were correlated with isthmus boundaries during VT. RESULTS: Among 202 deceleration zones analyzed during baseline rhythm, an overt LOB was evident in 47%. When differential pacing was performed in 38 deceleration zones without overt LOB, an underlying concealed LOB was exposed in 84%. In 152 VT activation maps (2D=53, 3-dimensional [3D]=99), 69% of lateral boundaries colocalized with an LOB in 2D activation patterns, and the depth boundary during 3D VT colocalized with an LOB in 79%. In VT circuits with isthmus regions that colocalized with a U-shaped LOB (n=28), the boundary invariably served as both lateral boundaries in 2D and 3D. Overall, 74% of isthmus boundaries were identifiable as fixed LOB during baseline rhythm or differential pacing. CONCLUSIONS: The majority of VT circuit boundaries can be identified as fixed LOB from intrinsic or paced activation during sinus rhythm. Analysis of activation while pacing within the scar substrate is a novel technique that may unmask concealed LOB, previously interpreted to be functional in nature. An LOB from the perspective of a myocardial surface is frequently associated with intramural conduction, supporting the existence of a 3D hyperboloid VT circuit structure. Catheter ablation may be simplified to targeting both sides around an identified LOB during sinus rhythm.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Frequência Cardíaca/fisiologia , Bloqueio Cardíaco
2.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36852902

RESUMO

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento , Catéteres
3.
J Cardiovasc Electrophysiol ; 34(2): 478-482, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36579408

RESUMO

INTRODUCTION: Persistent left superior vena cava (PLSVC) is accompanied by enlarged coronary sinus (CS) and deformation of the triangle of Koch. This makes anatomical evaluation of the atrioventricular (AV) nodal pathways difficult. METHODS: We attempted cryoablation of retrograde fast pathway located in the enlarged CS roof of PLSVC for slow-fast AV nodal reentrant tachycardia (AVNRT) induced by inadvertent antegrade fast pathway elimination during ablation of left atrial tachycardia. RESULTS: Slow-fast AVNRT was successfully eliminated without AV block progression. CONCLUSIONS: This is the first case of successful retrograde fast pathway ablation of the CS ostial roof for slow-fast AVNRT with PLSVC.


Assuntos
Ablação por Cateter , Seio Coronário , Criocirurgia , Veia Cava Superior Esquerda Persistente , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Seio Coronário/diagnóstico por imagem , Seio Coronário/cirurgia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/cirurgia
4.
J Cardiovasc Electrophysiol ; 34(12): 2484-2492, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37752712

RESUMO

INTRODUCTION: Cryoballoon ablation (CBA) of the left atrial (LA) roof in addition to a pulmonary vein isolation has been expected to improve the clinical outcomes post-atrial fibrillation (AF) ablation. We demonstrated the characteristics and efficacy of CBA of the LA roof through our experience with a large volume of procedures. METHODS: Among 1036 AF ablation procedures with CBA of the LA roof, 834 patients who underwent a de novo ablation were analyzed. RESULTS: Complete LA roof line conduction block was obtained in 767 patients (92.0%) solely by CBA (Group A). Compared with the other patients (Group B), the mean nadir balloon temperature during CBA of the LA roof (-44.5 ± 5.6°C for Group A vs. -40.5 ± 7.5°C for Group B, p < .01) and number of cryoballoon applications during the LA roof ablation with a circular mapping catheter located in the left superior pulmonary vein (1.3 ± 0.8 for Group A vs. 1.6 ± 1.0 for Group B, p = .02) were significantly lower in Group A. A multivariate analysis revealed that those were predictors of a complete LA roof conduction block after only CBA. The 1-year Kaplan-Meier atrial arrhythmia free rate estimates were 80.6% for Group A and 59.0% for Group B (p < .01). CONCLUSION: Complete LA roof line conduction block could be obtained with a cryoballoon without touch-up ablation in most cases. The LA roof CBA with a circular mapping catheter located in the right superior pulmonary vein was preferable to obtaining complete LA roof conduction block, which was important with regard to the clinical outcomes.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
5.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37431258

RESUMO

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Cicatriz , Ablação por Cateter/efeitos adversos
6.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36906814

RESUMO

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Temperatura , Ablação por Cateter/efeitos adversos , Irrigação Terapêutica/efeitos adversos , Desenho de Equipamento
7.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37337433

RESUMO

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Assuntos
Ablação por Cateter , Vapor , Suínos , Animais , Impedância Elétrica , Benchmarking , Ablação por Cateter/efeitos adversos , Solução Salina
8.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37490850

RESUMO

AIMS: The effectiveness of pulmonary vein isolation (PVI) guided by VISITAG SURPOINT (VS) has been demonstrated in Western populations. However, data for Asian populations are limited. VS settings may differ for Asians, given their smaller body size. This study aimed to describe outcomes of radiofrequency atrial fibrillation (AF) ablation guided by VS in a large Asian population. METHODS AND RESULTS: The prospective, observational, multicentre MIYABI registry collected real-world data from patients undergoing VS-guided AF ablation using ThermoCool SmartTouch and ThermoCool SmartTouch SF catheters from 50 Japanese centres. All patients had paroxysmal AF or persistent AF for <6 months. Primary adverse events (PAEs) were evaluated for safety. The primary efficacy endpoint was the proportion of patients with PVI at the end of the procedure. Mid-term effectiveness (up to 12 months) was evaluated by freedom from documented atrial arrhythmias. Of the 1011 patients enrolled, 1002 completed AF ablation. The mean number of VS values per procedure was 428.8 on the anterior wall and 400.4 on the posterior wall. Nine patients (0.9%) experienced PAEs. Upon procedure completion, 99.7% of patients had PVI. Twelve-month freedom from atrial arrhythmia recurrence was 88.5%; 5.7% of patients were re-ablated. At repeat ablation, 54% of RSPV, 73% of RIPV, 70% of LSPV, and 86% of LIPV evaluated remained durably isolated. CONCLUSION: Despite lower anterior wall VS values compared with the CLOSE protocol (≥550), the present study demonstrated comparable efficacy outcomes, indicating that a VS of ≥550 for the anterior wall may not be necessary for Asian patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Japão , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
9.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38096246

RESUMO

AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Cicatriz/complicações , Cicatriz/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas , Ventrículos do Coração , Endocárdio , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37428890

RESUMO

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Humanos , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia , Átrios do Coração , Resultado do Tratamento
11.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36892146

RESUMO

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Falência Renal Crônica , Tromboembolia , Humanos , Feminino , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
12.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-37899173

RESUMO

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Assuntos
Ablação por Cateter , Solução Salina , Animais , Suínos , Ventrículos do Coração/patologia , Coração , Catéteres , Ablação por Cateter/métodos , Desenho de Equipamento , Impedância Elétrica
13.
Pacing Clin Electrophysiol ; 46(6): 515-518, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36690018

RESUMO

The 12-lead electrocardiogram (ECG) is a fundamental modality to help determine the mechanism and the localization of atrial tachycardias (ATs). Although macroreentrant ATs and focal ATs typically show F-waves and discrete P-waves respectively on the 12-lead ECG, this is not universally the case in scar-related ATs.1, We present three cases clearly showing the discrepancy between the AT morphology on the 12-lead ECG and the AT-mechanism.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Taquicardia Supraventricular , Humanos , Cicatriz , Eletrocardiografia
14.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37957924

RESUMO

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Assuntos
Ablação por Cateter , Vapor , Humanos , Animais , Suínos , Irrigação Terapêutica , Desenho de Equipamento , Catéteres
15.
Pacing Clin Electrophysiol ; 46(6): 475-486, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37129189

RESUMO

BACKGROUNDS: Catheter ablation for non-paroxysmal atrial fibrillation (non-PAF) remains challenging and more effective strategy has been required to reduce postoperative arrhythmia recurrences. This study aims to investigate the efficacy and safety of a novel extensive ablation strategy for non-PAF, that is based on a combination of cryoballoon (CBA), radiofrequency (RFA), and Marshall-vein ethanol ablations (EA-VOM). METHODS: The study was a single-center, retrospective observational study. We enrolled 171 consecutive patients who underwent de-novo catheter ablation for non-PAF under conscious sedation with a novel extensive ablation strategy that included CBA for pulmonary vein isolation (PVI) and left atrial roof ablation (LARA), RFA for mitral isthmus (MI) ablation, superior vena cava isolation, and other linear ablations and EA-VOM. Recurrence of atrial arrhythmias over 1 year, procedure outcomes, and procedure-related complications were investigated. RESULTS: A total of 139 (81.3%) patients remained in sinus rhythm during 1-year follow-up. Of the 139 patients, 51 patients (29.8%) received antiarrhythmic drugs. The mean procedure time was 204 ± 45 min. PVI and LARA ablation by CBA and MI block by RFA and EA-VOM were completed in 171 (100%) and 166 (97.1%) patients, respectively. No serious procedure-related complications were observed except for one case of delayed pericardial effusion. CONCLUSION: Approximately 80% of the study patients were AF-free during 1-year follow-up period after a single procedure based on the novel extensive ablation strategy combining CBA, RFA, and EA-VOM. This strategy for non-PAF may be preferred in terms of maintenance of sinus rhythm, safety even in high-risk patients, and relatively short procedure time.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Etanol , Veia Cava Superior , Átrios do Coração , Veias Pulmonares/cirurgia , Criocirurgia/métodos , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
16.
Europace ; 24(11): 1769-1776, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851606

RESUMO

AIMS: The efficacy of left atrial posterior wall isolation (PWI) is controversial. Lesion durability may be a major cause of arrhythmia recurrence. The use of the lesion size prediction module improves lesion durability. This study aimed to compare the clinical outcomes of pulmonary vein isolation (PVI) alone and PWI in addition to PVI (PVI + PWI) in patients with non-paroxysmal atrial fibrillation (AF) using a lesion size prediction module. METHODS AND RESULTS: This study is a sub-analysis of the recently published prospective multicentre observational study called ALCOHOL-AF (association of alcohol consumption with outcome of catheter ablation of AF). In this sub-analysis, patients with non-paroxysmal AF in whom PVI alone or PVI + PWI was performed using the lesion size prediction module were included. Freedom from atrial tachyarrhythmia was compared between PVI alone and PVI + PWI groups using propensity score analyses. Of the 3474 patients registered in the ALCOHOL-AF study, 572 patients (age 65.6 ± 10.1 years, male 77.4%, longstanding persistent AF 25.5%) were included in this sub-analysis. We selected 212 patients treated with PVI alone and 212 treated with PVI + PWI using one-to-one propensity score matching. During the follow-up period, atrial tachyarrhythmia recurrence was documented in 92 (43.4%) and 50 (23.6%) patients in the PVI alone and PVI + PWI groups, respectively. Freedom from atrial tachyarrhythmia recurrence without anti-arrhythmic drugs after a single procedure was significantly higher in PVI + PWI than in PVI alone groups (hazard ratio: 0.452, 95% confidence interval: 0.308-0.664, P < 0.001). CONCLUSION: In this hypothesis-generating study, lesion size prediction module-guided PVI + PWI was associated with better clinical outcomes than PVI alone in patients with persistent or longstanding persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Resultado do Tratamento , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
17.
Pacing Clin Electrophysiol ; 45(1): 5-13, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34679229

RESUMO

INTRODUCTION: Gastric hypomotility (GH) is a major complication of atrial fibrillation (AF) ablation. We aimed to clarify whether additional cryoballoon ablation (CBA) of the left atrial (LA) roof is associated with GH. METHODS AND RESULTS: This study included 54 patients with non-paroxysmal AF who underwent CBA for pulmonary vein isolation and of the LA roof line. GH was defined according to the results of esophagogastroscopy performed 2 days after ablation. GH was observed in 10 patients. There were significant differences in LA diameter (LAD), right inferior pulmonary vein (RIPV) diameter, and the height of the LA roof from the point where the LA posterior wall and esophagus make contact between patients with (GH+) and without GH (GH-) (LAD: 41.0 [36.3-41.8] mm vs. 46.5 [42.8-50.0] mm, p < .01; RIPV diameter: 19.7 [19.0-20.5] mm vs. 23.2 [21.2-24.9] mm, p < .01; height of LA roof: 5.7 [5.1-6.1] mm vs. 8.8 [7.1-11.2] mm for, p < .01, respectively). Multivariate analysis revealed that LA roof height was a predictor of GH. Moreover, Patient Assessment of Upper Gastrointestinal Disorders-Symptom Severity Index (PAGI-SYM) scores increased significantly 1 week after ablation (from 1.0 [0.0-2.8] to 5.0 [3.0-11.0], p = .03) in patients with GH. CONCLUSION: The height of the LA roof may be a predictor of GH after CBA of the LA roof line. Additionally, GH-related symptoms may still appear 1 week after ablation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/cirurgia , Estômago/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos
18.
Pacing Clin Electrophysiol ; 45(9): 1141-1150, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35665518

RESUMO

BACKGROUND: This study was aimed to investigate the efficacy of the over-the-wire (OTW) microelectrodes catheter in coronary venous system (CVS) mapping and treatment of outflow tract ventricular arrhythmia (OTVA) arising from the vicinity of the left ventricular summit (LVS). METHODS: Consecutive 62 patients with idiopathic OTVA in whom the OTW microelectrodes catheter was routinely used for CVS mapping were analyzed. CVS mapping was performed for both main trunk (from great cardiac vein to anterior interventricular vein) and branches including the annular branch or septal branch. RESULTS: The earliest activation site (EAS) was within the CVS in 21 patients. Among them, the EAS was within the main trunk of the CVS in seven (33%) and within the branch of the CVS in 14 (67%) patients. Radiofrequency catheter ablation was started at an anatomically adjacent site to the EAS, which eliminated OTVA in 16 (76%) patients (the endocardial LVOT in 10 and the aortic sinus of Valsalva in six patients). For the remaining five patients with unsuccessful catheter ablation at an anatomically adjacent site, targeted OTVA was eliminated by catheter ablation at the EAS within the CVS in two patients and by chemical ablation with ethanol injection in one patient, resulting in the overall success rate of 90% (19/21). CONCLUSION: The OTW microelectrodes-guided ablation of OTVA from the vicinity of the LVS was effective. In maximizing the efficacy of ablation, CVS branch mapping is important since the earliest activation was commonly recorded not in the main trunk but within the branch of the CVS.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas/cirurgia , Ablação por Cateter/métodos , Catéteres , Eletrocardiografia , Etanol , Ventrículos do Coração , Humanos , Microeletrodos , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 45(2): 196-203, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34981524

RESUMO

BACKGROUND: Implantations of leadless pacemakers in the septum lower the risk of cardiac perforation. However, the relationship between the implantation site and the success rate, complication rate, and pacemaker parameters are not well-investigated. METHODS: Patients who underwent leadless pacemaker implantation with postprocedural computed tomography (CT) between September 2017 and November 2020 were analyzed. Septum was targeted with fluoroscopic guidance with contrast injection. We divided patients into two groups based on the implantation site confirmed by CT: septal and non-septal, which included the anterior/posterior edge of the septum and free wall. We compared the complication rates and pacemaker parameters between the two groups. RESULTS: A total of 67 patients underwent CT after the procedure; among them, 28 were included in the septal group and 39 were included in the non-septal group. The non-septal group had significantly higher R wave amplitudes (6.5 ± 3.3 vs. 9.7 ± 3.9 mV, p = .001), lower pacing threshold (1.0 ± 0.94 vs. 0.63 ± 0.45 V/0.24 ms, p = .02), and higher pacing impedance (615 ± 114.1 vs. 712.8 ± 181.3 ohms, p = .014) after the procedure compared to the septal group. Cardiac injuries were observed in four patients (one cardiac tamponade, one possible apical hematoma, two asymptomatic pericardial effusion), which were only observed in the non-septal group. CONCLUSIONS: Leadless pacemaker implantation may be technically challenging with substantial number of patients with non-septal implantation when assessed by CT. Septal implantation may have a lower risk of cardiac injury but may lead to inferior pacemaker parameters than non-septal implantation.


Assuntos
Marca-Passo Artificial , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso de 80 Anos ou mais , Meios de Contraste , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino
20.
Int Heart J ; 63(6): 1085-1091, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36450547

RESUMO

Pulmonary vein isolation (PVI) with a balloon-based visually guided laser ablation (VGLA) is regarded as a useful therapeutic tool for treating atrial fibrillation (AF). The clinical efficacy of a VGLA has never been fully investigated in patients with left common pulmonary vein (LCPV). We investigated the procedural safety as well as clinical usefulness of VGLA in patients with LCPV.This study consisted of 130 consecutive patients who underwent VGLA of de novo nonvalvular paroxysmal AF.Eleven patients (8.5%) had an LCPV (ostium maximal average diameter: 27.5 ± 4.9 mm, ostium minimal average diameter: 17.7 ± 3.5 mm). Nine out of 11 (81.8%) LCPVs were successfully occluded and isolated at the ostium with a VGLA-guided PVI. The ablation procedure time was significantly shorter in the patients with than without an LCPV (61.5 ± 15.4 versus 86.9 ± 32.9 minutes, P = 0.01). There was no difference regarding the atrial tachyarrhythmia recurrence between those with and without an LCPV (P = 0.18). A total of 15 patients underwent a redo procedure, but reconnections were not observed in any of the LCPV patients.The VGLA-guided PVI was a useful therapeutic tool even in patients with an LCPV. The presence of an LCPV might not be associated with an increased risk of any atrial tachyarrhythmia recurrence.


Assuntos
Fibrilação Atrial , Terapia a Laser , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Átrios do Coração , Fibrilação Atrial/cirurgia , Lasers