Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Nano Lett ; 22(21): 8541-8549, 2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36287197

RESUMO

Addressable quantum states well isolated from the environment are of considerable interest for quantum information science and technology. Carbon nanotubes are an appealing system, since a perfect crystal can be grown without any missing atoms and its cylindrical structure prevents ill-defined atomic arrangement at the surface. Here, we develop a reliable process to fabricate compact multielectrode circuits that can sustain the harsh conditions of the nanotube growth. Nanotubes are suspended over multiple gate electrodes, which are themselves structured over narrow dielectric ridges to reduce the effect of the charge fluctuators of the substrate. We measure high-quality double- and triple-quantum dot charge stability diagrams. Transport measurements through the triple-quantum dot indicate long-range tunneling of single electrons between the left and right quantum dots. This work paves the way to the realization of a new generation of condensed-matter devices in an ultraclean environment, including spin qubits, mechanical qubits, and quantum simulators.

2.
Phys Rev Lett ; 126(17): 175502, 2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33988423

RESUMO

We report the first study on the thermal behavior of the stiffness of individual carbon nanotubes, which is achieved by measuring the resonance frequency of their fundamental mechanical bending modes. We observe a reduction of the Young's modulus over a large temperature range with a slope -(173±65) ppm/K in its relative shift. These findings are reproduced by two different theoretical models based on the thermal dynamics of the lattice. These results reveal how the measured fundamental bending modes depend on the phonons in the nanotube via the Young's modulus. An alternative description based on the coupling between the measured mechanical modes and the phonon thermal bath in the Akhiezer limit is discussed.

3.
Ultrasound Obstet Gynecol ; 58(1): 34-41, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32484578

RESUMO

OBJECTIVES: Corpus callosal agenesis (CCA) is one of the most common brain malformations and is generally associated with a good outcome when isolated. However, up to 25% of patients are at risk of neurodevelopmental delay, which currently available clinical and imaging parameters are inadequate to predict. The objectives of this study were to apply and validate a fetal magnetic resonance imaging (MRI) anatomical scoring system in a cohort of fetuses with isolated CCA and to evaluate the correlation with postnatal neurodevelopmental outcome. METHODS: This was a retrospective cohort study of cases of prenatally diagnosed isolated CCA (as determined on ultrasound and MRI), with normal karyotype and with known postnatal neurodevelopmental outcome assessed by standardized testing. A fetal brain MRI anatomical scoring system based on seven categories (gyration, opercularization, temporal lobe symmetry, lamination, hippocampal position, basal ganglia and ventricular size) was developed and applied to the cohort; a total score of 0-11 points could be given, with a score of 0 representing normal anatomy. Images were scored independently by two neuroradiologists blinded to the outcome. For the purpose of assessing the correlation between fetal MRI score and neurodevelopmental outcome, neurodevelopmental test results were scored as follows: 0, 'below average' (poor outcome); 1, 'average'; and 2, 'above average' (good outcome). Spearman's rank coefficient was used to assess correlation, and inter-rater agreement in the assessment of fetal MRI score was calculated. RESULTS: Twenty-one children (nine females (42.9%)) fulfilled the inclusion criteria. Thirty-seven fetal MRI examinations were evaluated. Mean gestational age was 28.3 ± 4.7 weeks (range, 20-38 weeks). All fetuses were delivered after 35 weeks' gestation with no perinatal complications. Fetal MRI scores ranged from 0 to 6 points, with a median of 3 points. Inter-rater agreement in fetal MRI score assessment was excellent (intraclass correlation coefficient, 0.959 (95% CI, 0.921-0.979)). Neurodevelopmental evaluation was performed on average at 2.6 ± 1.46 years (range, 0.5-5.8 years). There was a significant negative correlation between fetal MRI score and neurodevelopmental outcome score in the three areas tested: cognitive (ρ = -0.559, P < 0.0001); motor (ρ = -0.414, P = 0.012) and language (ρ = -0.565, P < 0.0001) skills. Using fetal MRI score cut-offs of ≤ 3 (good outcome) and ≥ 4 points (high risk for poor outcome), the correct prognosis could be determined in 20/21 (95.2% (95% CI, 77.3-99.2%)) cases. CONCLUSION: By assessing structural features of the fetal brain on MRI, it may be possible to better stratify prenatally the risk of poor neurodevelopmental outcome in CCA patients. © 2020 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Agenesia do Corpo Caloso/diagnóstico por imagem , Feto/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Transtornos do Neurodesenvolvimento/diagnóstico por imagem , Agenesia do Corpo Caloso/complicações , Agenesia do Corpo Caloso/embriologia , Encéfalo/diagnóstico por imagem , Encéfalo/embriologia , Pré-Escolar , Corpo Caloso/diagnóstico por imagem , Corpo Caloso/embriologia , Corpo Caloso/fisiopatologia , Feminino , Feto/embriologia , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Masculino , Transtornos do Neurodesenvolvimento/etiologia , Valor Preditivo dos Testes , Gravidez , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Estatísticas não Paramétricas , Ultrassonografia Pré-Natal
4.
Ultrasound Obstet Gynecol ; 58(2): 254-263, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32730667

RESUMO

OBJECTIVES: To characterize spatiotemporal growth differences of prenatal brainstem substructures and cerebellum, using linear biometry and planimetry on fetal magnetic resonance imaging (MRI). METHODS: In this retrospective study, we included fetuses with normal brain and a precise midsagittal T2-weighted brain MRI sequence obtained between May 2003 and April 2019. The cross-sectional area, rostrocaudal diameter and anteroposterior diameter of the midbrain, pons (basis pontis and pontine tegmentum), medulla oblongata and cerebellar vermis, as well as the transverse cerebellar diameter, were quantified by a single observer. The diameters were also assessed by a second observer to test inter-rater variability. RESULTS: We included 161 fetuses with normal brain and a precise midsagittal MRI sequence, examined at a mean ± SD gestational age of 25.7 ± 5.4 (range, 14 + 0 to 39 + 2) weeks. All substructures of the fetal brainstem and the cerebellum could be measured consistently (mean ± SD interobserver intraclass correlation coefficient, 0.933 ± 0.065). We provide reference data for diameters and areas of the brainstem and cerebellum in the second and third trimesters. There was a significant quadratic relationship between vermian area and gestational age, and all other measured parameters showed a significant linear growth pattern within the observed period (P < 0.001). A significant change in the relative proportions of the brainstem substructures occurred between the beginning of the second trimester and the end of the third trimester, with an increase in the area of the pons (P < 0.001) and a decrease in that of the midbrain (P < 0.001), relative to the total brainstem area. CONCLUSIONS: The substructures of the fetal brainstem follow a distinct spatiotemporal growth pattern, characterized by a relative increase in the pons and decrease in the midbrain, between 15 and 40 weeks of gestation. Caution is needed when interpreting fetal brainstem appearance during the early second trimester, as the brainstem proportions differ significantly from the adult morphology. The reference data provided herein should help to increase diagnostic accuracy in detecting disorders of defective hindbrain segmentation. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Tronco Encefálico/diagnóstico por imagem , Feto/diagnóstico por imagem , Diagnóstico Pré-Natal , Tronco Encefálico/crescimento & desenvolvimento , Feminino , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética , Gravidez , Valores de Referência , Estudos Retrospectivos
5.
Ultrasound Obstet Gynecol ; 56(1): 78-85, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31595598

RESUMO

OBJECTIVE: Normal cognitive development usually requires a structurally intact and complete cerebellar vermis. The aim of this study was to evaluate whether quantification by fetal magnetic resonance imaging (MRI) of vermis- and brainstem-specific imaging markers improves the definition of cystic posterior fossa malformations (cPFM). METHODS: Fetuses diagnosed with cPFM that had an available midsagittal plane on T2-weighted MRI were identified retrospectively and compared with gestational-age (GA) matched brain-normal controls. Fetuses with cPFM were assigned to three groups, according to standard criteria (vermian size and brainstem-vermis (BV) angle): normal vermian area and BV angle < 25° (Group 1); reduced vermian area and/or BV angle of 25-45° (Group 2); and reduced vermian area and BV angle > 45° (Group 3; Dandy-Walker malformation (DWM) group). The number of differentiable vermian lobules and the areas of the vermis, mesencephalon, pons and medulla oblongata were quantified, correlated with and controlled for GA, and compared between the study groups. RESULTS: In total, 142 cases of cPFM were included, with a mean GA of 25.20 ± 5.11 weeks. Cases comprised Blake's pouch cyst (n = 46), arachnoid cyst (n = 12), inferior vermian hypoplasia (n = 5), megacisterna magna (n = 35) and classic DWM (n = 44). In the control group, 148 fetuses were included, with a mean GA of 25.26 ± 4.12 weeks. All quantified areas and the number of differentiable vermian lobules had a significant positive correlation with GA. The number of vermian lobules and the areas of all quantified regions, except for that of the medulla oblongata, differed significantly between the study groups (P ≤ 0.015 for all). The control group had the highest number of differentiable vermian lobules and the DWM group had the lowest (P < 0.01). CONCLUSIONS: Prenatal MRI assessment of vermian lobules is a useful addition to standard neuroradiological and neurosonographic techniques. The quantification of vermian lobules using fetal MRI allows further differentiation of cPFM into subgroups and thereby improves the classification of hindbrain malformations. © 2019 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Síndrome de Dandy-Walker/diagnóstico por imagem , Malformações do Sistema Nervoso/diagnóstico por imagem , Adulto , Fossa Craniana Posterior/anormalidades , Fossa Craniana Posterior/diagnóstico por imagem , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Valor Preditivo dos Testes , Gravidez , Diagnóstico Pré-Natal
6.
Nano Lett ; 19(10): 6987-6992, 2019 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-31478676

RESUMO

We report on a nanomechanical engineering method to monitor matter growth in real time via e-beam electromechanical coupling. This method relies on the exceptional mass sensing capabilities of nanomechanical resonators. Focused electron beam-induced deposition (FEBID) is employed to selectively grow platinum particles at the free end of singly clamped nanotube cantilevers. The electron beam has two functions: it allows both to grow material on the nanotube and to track in real time the deposited mass by probing the noise-driven mechanical resonance of the nanotube. On the one hand, this detection method is highly effective as it can resolve mass deposition with a resolution in the zeptogram range; on the other hand, this method is simple to use and readily available to a wide range of potential users because it can be operated in existing commercial FEBID systems without making any modification. The presented method allows one to engineer hybrid nanomechanical resonators with precisely tailored functionalities. It also appears as a new tool for studying the growth dynamics of ultrathin nanostructures, opening new opportunities for investigating so far out-of-reach physics of FEBID and related methods.

7.
Ultrasound Obstet Gynecol ; 53(6): 816-826, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30985045

RESUMO

OBJECTIVE: To assess the clinical feasibility and validity of fetal magnetic resonance imaging (MRI)-based three-dimensional (3D) reconstruction to locate, classify and quantify diaphragmatic defects in congenital diaphragmatic hernia (CDH). METHODS: This retrospective study included 46 cases of CDH which underwent a total of 69 fetal MRI scans (65 in-vivo and four postmortem) at the Medical University of Vienna during the period 1 January 2002 to 1 January 2017. Scans were performed between 16 and 38 gestational weeks using steady-state free precession, T2-weighted and T1-weighted sequences. MRI data were retrieved from the hospital database and manual segmentation of the diaphragm was performed with the open-source software, ITK-SNAP. The resulting 3D models of the fetal diaphragm and its defect(s) were validated by postmortem MRI segmentation and/or comparison of 3D model-based classification of the defect with a reference classification based on autopsy and/or surgery reports. Surface areas of the intact diaphragm and of the defect were measured and used to calculate defect-diaphragmatic ratios (DDR). The need for prosthetic patch repair and, in cases with repeated in-vivo fetal MRI scans, diaphragm growth dynamics, were analyzed based on DDR. RESULTS: Fetal MRI-based manual segmentation of the diaphragm in CDH was feasible for all 65 (100%) of the in-vivo fetal MRI scans. Based on the 3D diaphragmatic models, one bilateral and 45 unilateral defects (n = 47) were further classified as posterolateral (23/47, 48.9%), lateral (7/47, 14.9%) or hemidiaphragmatic (17/47, 36.2%) defects, and none (0%) was classified as anterolateral. This classification of defect location was correct in all 37 (100%) of the cases in which this information could be verified. Nineteen cases had a follow-up fetal MRI scan; in five (26.3%) of these, the initial CDH classification was altered by the results of the second scan. Thirty-three fetuses underwent postnatal diaphragmatic surgical repair; 20 fetuses (all of those with DDR ≥ 54 and 88% of those with DDR > 30) received a diaphragmatic patch, while the other 13 underwent primary surgical repair. Individual DDRs at initial and at follow-up in-vivo fetal MRI correlated significantly (P < 0.001). CONCLUSIONS: MRI-based 3D reconstruction of the fetal diaphragm in CDH has been validated to visualize, locate, classify and quantify the defect. Planning of postnatal surgery may be optimized by MRI-based prediction of the necessity for patch placement and the ability to personalize patch design based on 3D-printable templates. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Diagnóstico Pré-Natal , Feminino , Hérnias Diafragmáticas Congênitas/cirurgia , Humanos , Valor Preditivo dos Testes , Gravidez , Estudos Retrospectivos
8.
Orthopade ; 48(1): 105-116, 2019 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-30259059

RESUMO

Platelet-rich plasma (PRP) and growth factors have been increasing in popularity for the orthopedic treatment of degenerative and traumatic diseases. The treatment concept is based on the substitution of growth-inducing substances in tissues with low or absent regeneration capacity (cartilage, tendons) as well as for the induction or further acceleration of growth and regeneration (bone, muscle). This review article provides an overview on the clinical feasibility of usage and a summary of the current study situation.


Assuntos
Sistema Musculoesquelético , Plasma Rico em Plaquetas , Cartilagem , Peptídeos e Proteínas de Sinalização Intercelular , Tendões
9.
Ultrasound Obstet Gynecol ; 52(5): 623-630, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28782259

RESUMO

OBJECTIVES: To optimize the imaging assessment of fetal hindbrain malformations, this observational magnetic resonance imaging (MRI) study aimed to assess whether fetal vermian lobulation can be quantified accurately and whether the relative growth of vermian lobules is uniform. METHODS: This retrospective study included singleton fetuses which underwent T2-weighted MRI in vivo with a 1.5-Tesla (T) scanner or within 24 h postmortem with a 3-T scanner between January 2007 and November 2016 at the Medical University of Vienna. We included only those showing normal structural brain development on ultrasound and MRI and which had image quality appropriate for quantitative analysis, i.e. good image quality and a precise midsagittal slice. Fetal brains were segmented and, for all discernible vermian lobules, we determined the mean relative area contribution (MRAC, the proportion of the lobule relative to the total vermian area, in terms of number of voxels). Inter- and intrarater measurement variability of a representative selection (21 cases) was determined by intraclass correlation coefficient (ICC) for voxel-based differences. A linear regression model was used to assess the correlation between the relative size of each vermian lobule (i.e. MRAC) and gestational age. RESULTS: A total of 78 fetuses scanned in vivo aged 18-32 gestational weeks and seven fetuses scanned postmortem aged 16-30 weeks had a precise midsagittal slice and image quality sufficient for quantitative analysis. After 22 weeks of gestation, seven of the nine known vermian lobules could be discriminated reliably. The MRAC showed a mean ± SD difference of only 2.89 ± 3.01% between in-vivo and postmortem measurements. The ICC of voxel-based interrater differences was mean ± SD, 0.91 ± 0.05 and the intrarater ICC was 0.95 ± 0.03. Growth of cerebellar lobules was non-uniform: the MRAC of culmen and DFT (declive + folium + tuber) increased with gestational age, whereas that of lingula, centralis, pyramis and nodulus decreased. The growth of the uvula showed no significant correlation with gestational age. CONCLUSIONS: Fetal vermian lobulation can be assessed accurately and reliably after 22 weeks on precise midsagittal sequences with 1.5-T T2-weighted MRI. Fetal vermian lobules show non-uniform growth, with expansion of DFT and culmen at the expense of the other vermian lobules. Evaluation and elucidation of vermian lobulation in normal fetuses should enable better characterization of fetuses with hindbrain malformations. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Vermis Cerebelar/anormalidades , Imageamento por Ressonância Magnética , Diagnóstico Pré-Natal , Autopsia , Vermis Cerebelar/diagnóstico por imagem , Vermis Cerebelar/embriologia , Feminino , Idade Gestacional , Humanos , Valor Preditivo dos Testes , Gravidez
10.
Orthopade ; 46(11): 919-927, 2017 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-28852793

RESUMO

BACKGROUND: Cartilage defects around the knee joint frequently occur in the region of the medial femoral condyle and the retropatellar cartilage surface. The distinction between local cartilage defects and large area degenerative cartilage lesions is very important for both prognosis and surgical therapy. The size and position of the lesion, the underlying pathomechanism and the age of the patient are very important factors which should be considered in the therapy algorithm for optimal cartilage defect restoration. Important cofactors such as stability, long leg axis and muscle balance should be taken into account. AIM: Current procedures for cartilage repair of the knee joint and their results are summarized in this article. In addition, the necessity of precise and comprehensive preoperative clinical and radiological diagnostics is displayed to be able to treat co-pathologies in order to enable a successful repair of the cartilage defect. RESULTS AND CONCLUSIONS: Preoperative planning of cartilage-repair techniques usually includes x­ray images and a magnetic resonance imaging (MRI) examination. If MRI is not available, an arthro-computed tomography could be an alternative. Modern and routinely used procedures for cartilage repair at the knee joint are microfracture, autologous matrix-induced chondrogenesis, autologous chondrocyte transplantation, matrix-induced autologous chondrocyte implantation and osteochondral transplantation. Successful surgical cartilage-repair surgeries require a correct and individualized indication, addressing of copathologies and a standardized rehabilitation that is adapted to the surgical procedure. Evidence-based criteria for an exact time point for the return to sports according to individually operative cartilage repair techniques currently do not exist.


Assuntos
Cartilagem Articular/lesões , Cartilagem Articular/cirurgia , Traumatismos do Joelho/cirurgia , Autoenxertos , Medula Óssea/fisiopatologia , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/fisiopatologia , Condrócitos/fisiologia , Condrócitos/transplante , Fraturas de Estresse/fisiopatologia , Fraturas de Estresse/cirurgia , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Imageamento por Ressonância Magnética , Regeneração/fisiologia , Tomografia Computadorizada por Raios X
11.
Eur J Vasc Endovasc Surg ; 49(2): 166-73, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25549577

RESUMO

OBJECTIVES: The aim was to investigate whether the fascia suture technique (FST) can reduce access closure time and procedural costs compared with the Prostar technique (Prostar) in patients undergoing endovascular aortic repair and to evaluate the short- and mid-term outcomes of both techniques. METHODS: In this two center trial, 100 patients were randomized to access closure by either FST or Prostar between June 2006 and December 2009. The primary endpoint was access closure time. Secondary outcome measures included access related costs and evaluation of the short- and mid-term complications. Evaluation was performed peri- and post-operatively, at discharge, at 30 days and at 6 months follow up. RESULTS: The median access closure time was 12.4 minutes for FST and 19.9 minutes for Prostar (p < .001). Prostar required a 54% greater procedure time than FST, mean ratio 1.54 (95% CI 1.25-1.90, p < .001) according to regression analysis. Adjusted for operator experience the mean ratio was 1.30 (95% CI 1.09-1.55, p = .005) and for patient body mass index 1.59 (95% CI 1.28-1.96, p < .001). The technical failure rate for operators at proficiency level was 5% (2/40) compared with 28% (17/59) for those at the basic level (p = .003). The proficiency level group had a technical failure rate of 4% (1/26) for FST and 7% (1/14) for Prostar, p = 1.00, while corresponding rates for the basic level group were 27% (6/22) for FST and 30% (11/37) for Prostar (p = .84). There was a significant difference in cost in favor of FST, with a median difference of €800 (95% CI 710-927, p < .001). CONCLUSIONS: In aortic endovascular repair FST is a faster and cheaper technique than the Prostar technique.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Cateterismo Periférico , Procedimentos Endovasculares , Fasciotomia , Artéria Femoral/cirurgia , Técnicas de Sutura/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/economia , Competência Clínica , Redução de Custos , Análise Custo-Benefício , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/economia , Desenho de Equipamento , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Duração da Cirurgia , Punções , Técnicas de Sutura/economia , Suécia , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Oclusão Vascular/economia
12.
Ultraschall Med ; 36(4): 342-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24824761

RESUMO

PURPOSE: The great auricular nerve (GAN) is a sensory branch of the superficial cervical plexus. While its blockade is an established procedure, little is known about the ultrasound appearance of pathologic conditions of the GAN itself. We, therefore, aimed to evaluate the possibility of the visualization and diagnostic assessment of the GAN along its entire course by means of high-resolution ultrasound (HRUS). MATERIALS AND METHODS: To assess the feasibility of visualization, we performed HRUS with an 18 MHz probe, HRUS-guided, fine-needle ink markings and consecutive dissection in six anatomical specimens. Then, we measured the diameter of the GAN in healthy volunteers and finally performed a retrospective review of patients referred for HRUS examinations because of pain within GAN territory between August 1, 2012 and August 1, 2013. RESULTS: The GAN was clearly visible with HRUS from its formation to the final branches, and was marked successfully on both sides in all anatomical specimens (n = 12). The mean average in-vivo was 0.14 cm ± 0.03 (range 0.08-0.2). Seven cases of patients with GAN pathologies of various origins (idiopathic, traumatic, tumorous and iatrogenic) were identified, of which 6 were visible on HRUS and all of which could be confirmed by complete resolution of symptoms after selective HRUS-guided GAN block. CONCLUSION: This study confirms the reliable ability to visualize the GAN with HRUS throughout its course, both in anatomical specimens and in vivo. The provided cases show that pathologies of the GAN seem to have a variety of causes and may not be rare. We, therefore, encourage the use of HRUS in patients with unclear pain in the auricular, periauricular and posterior-lateral head.


Assuntos
Plexo Cervical/diagnóstico por imagem , Orelha Externa/inervação , Aumento da Imagem/métodos , Doenças do Sistema Nervoso Periférico/diagnóstico por imagem , Nervos Espinhais/diagnóstico por imagem , Adulto , Plexo Cervical/patologia , Feminino , Humanos , Aumento da Imagem/instrumentação , Masculino , Pessoa de Meia-Idade , Neuroma/diagnóstico por imagem , Neuroma/patologia , Doenças do Sistema Nervoso Periférico/patologia , Neoplasias do Sistema Nervoso Periférico/diagnóstico por imagem , Neoplasias do Sistema Nervoso Periférico/patologia , Sensibilidade e Especificidade , Nervos Espinhais/patologia , Ultrassonografia
13.
Ultraschall Med ; 36(3): 264-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24647766

RESUMO

PURPOSE: The long thoracic nerve (LTN) innervates the serratus anterior muscle (SA) which plays an important role in shoulder function. Evaluation of the LTN has so far been restricted to clinical assessment and partly electromyography and neurography. Progress of high-resolution ultrasound (HRUS) increasingly enables visualization of small peripheral nerves and their pathologies. We therefore aimed at (a) clarifying the possibility of visualization of the LTN from its origin to the most distal point in the supraclavicular region visible and (b) developing an ultrasound protocol for routine use. We further present two cases of patients with LTN pathology. METHODS: The study consisted of two parts: Part 1 included 4 non-enbalmed human bodies in whom the LTN (n = 8) was located and then marked by ink injection. Correct identification was confirmed by anatomical dissection. Part 2 included 20 healthy volunteers whose LTN (n = 40) was assessed independently by two radiologists. Identification of the LTN was defined as consensus in recorded images. RESULTS: LTN was clearly visible in all anatomical specimens and volunteers using HRUS and could be followed until the second slip of the serratus anterior muscle from the supraclavicular region. In anatomical specimens, dissection confirmed HRUS findings. For all volunteers, consensus was obtained. The mean nerve diameter was 1.6 mm ±â€Š0.3 (range 1.1 - 2.1 mm) after the formation of the main trunk. DISCUSSION: We hereby confirm a reliable possibility of visualization of the LTN in anatomical specimens as well as in volunteers. We encourage HRUS of the LTN to be part of the diagnostic work-up in patients presenting with scapular winging, shoulder weakness or pain of unknown origin.


Assuntos
Músculos do Dorso/diagnóstico por imagem , Músculos do Dorso/inervação , Aumento da Imagem/métodos , Nervos Torácicos/diagnóstico por imagem , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Adulto , Músculos do Dorso/lesões , Músculos do Dorso/patologia , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/patologia , Neuroma/diagnóstico por imagem , Neuroma/patologia , Valores de Referência , Escápula/inervação , Sensibilidade e Especificidade , Nervos Torácicos/lesões , Nervos Torácicos/patologia , Tração/efeitos adversos , Adulto Jovem
16.
Eur J Orthop Surg Traumatol ; 23(2): 185-90, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23412450

RESUMO

BACKGROUND: An acromiohumeral interval narrower than 6 mm measured on AP shoulder radiographs has been considered pathological and suggestive of rotator cuff tears. This prospective study was conducted to assess inter- and intraobserver variation in the radiographic assessment of the acromiohumeral interval and its critical value on routinely taken AP shoulder radiographs off-study use to evaluate the accuracy of this measurement method. METHODS: The acromiohumeral distance from the inferior anterior acromial aspect to the humeral head was measured in millimeters. Thirty blinded, anteroposterior shoulder radiographs were independently reviewed by five board-certified orthopedic shoulder surgeons at two time points in random order. RESULTS: The results of three investigators showed significant intraobserver variation. Five investigator pairs showed significant interobserver variation at both examination time points. The maximum interobserver difference for the same radiograph was 8 mm (range 0 to 8 mm). CONCLUSION: Our results indicate that the assessment of the acromiohumeral interval using non-standardized anteroposterior radiographs off-study use cannot be seen as a reproducible and reliable method of measurement.


Assuntos
Acrômio/diagnóstico por imagem , Úmero/diagnóstico por imagem , Variações Dependentes do Observador , Ombro/diagnóstico por imagem , Acrômio/anatomia & histologia , Adulto , Idoso , Feminino , Humanos , Úmero/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Radiografia , Manguito Rotador/diagnóstico por imagem , Ombro/anatomia & histologia
17.
Eur Rev Med Pharmacol Sci ; 27(7): 3181-3190, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-37070921

RESUMO

OBJECTIVE: The aim of the present study was to assess the safety and efficacy of Diclofenac sodium (DS) 140 mg medicated plaster vs. Diclofenac epolamine (DIEP) 180 mg medicated plaster and placebo plaster, for the treatment of painful disease due to traumatic events of the limbs. PATIENTS AND METHODS: This was a multicenter, phase III study involving 214 patients, aged 18-65 years, affected by painful conditions due to soft tissue injuries. Patients were randomized to DS, DIEP or placebo arms and treated with once-daily application of the plaster for a total treatment period of 7 days. The primary objective was first to demonstrate the non-inferior efficacy of the DS treatment when compared to the reference DIEP treatment and second that both, test and reference treatments, were superior with respect to placebo. The secondary objectives included the evaluation of efficacy, adhesion, safety, and local tolerability of DS in comparison to both DIEP and placebo. RESULTS: The mean visual analog scale (VAS) score decrease for pain at rest was higher in the DS (-17.65 mm) and the DIEP group (-17.5 mm) than in the placebo (-11.3 mm). Both active formulation plasters were associated with a statistically significant pain reduction compared to placebo. No statistically significant differences were observed between DIEP and DS plasters efficacy in relieving pain. Secondary endpoint evaluations supported the primary efficacy results. No serious adverse events (SAEs) were registered, and the most commonly detected adverse events were skin reactions at the application site. CONCLUSIONS: The results showed that both the DS 140 mg plaster and the reference DIEP 180 mg plaster are effective in relieving pain and present a good safety profile.


Assuntos
Dor Aguda , Lesões dos Tecidos Moles , Humanos , Diclofenaco/efeitos adversos , Lesões dos Tecidos Moles/induzido quimicamente , Lesões dos Tecidos Moles/complicações , Método Duplo-Cego , Anti-Inflamatórios não Esteroides/efeitos adversos , Resultado do Tratamento
18.
Ann Oncol ; 23(11): 2852-2858, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22776708

RESUMO

BACKGROUND: Rates and risk factors of local, axillary and supraclavicular recurrences can guide patient selection and target for postmastectomy radiotherapy (PMRT). PATIENTS AND METHODS: Local, axillary and supraclavicular recurrences were evaluated in 8106 patients enrolled in 13 randomized trials. Patients received chemotherapy and/or endocrine therapy and mastectomy without radiotherapy. Median follow-up was 15.2 years. RESULTS: Ten-year cumulative incidence for chest wall recurrence of >15% was seen in patients aged <40 years (16.1%), with ≥4 positive nodes (16.5%) or 0-7 uninvolved nodes (15.1%); for supraclavicular failures >10%: ≥4 positive nodes (10.2%); for axillary failures of >5%: aged <40 years (5.1%), unknown primary tumor size (5.2%), 0-7 uninvolved nodes (5.2%). In patients with 1-3 positive nodes, 10-year cumulative incidence for chest wall recurrence of >15% were age <40, peritumoral vessel invasion or 0-7 uninvolved nodes. Age, number of positive nodes and number of uninvolved nodes were significant parameters for each locoregional relapse site. CONCLUSION: PMRT to the chest wall and supraclavicular fossa is supported in patients with ≥4 positive nodes. With 1-3 positive nodes, chest wall PMRT may be considered in patients aged <40 years, with 0-7 uninvolved nodes or with vascular invasion. The findings do not support PMRT to the dissected axilla.


Assuntos
Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Metástase Linfática , Mastectomia , Recidiva Local de Neoplasia , Adulto , Axila , Neoplasias da Mama/patologia , Feminino , Humanos , Excisão de Linfonodo , Linfonodos/patologia , Pessoa de Meia-Idade , Radioterapia Adjuvante , Receptores de Estrogênio/metabolismo , Fatores de Risco , Falha de Tratamento
20.
Water Sci Technol ; 66(2): 304-13, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22699334

RESUMO

Traditionally, design and optimisation of urban drainage systems was mainly driven by cost efficiency, surface flood prevention, and later by emission reduction. More recent procedures explicitly include ecological conditions of the receiving water in the definition of acceptable pollutant discharges via sewer system and treatment plant outlets. An ambient Water Quality based impact Assessment (WQA) principle therefore requires an integrative system optimisation. However, a broad range of mostly national WQA protocols exist across Europe varying in structure and complexity, assessment concept, spatial and temporal scope and handling of uncertainty. This variety inherently implies a considerable risk of subjectivity in the impact assessment with highly variable outcomes. The present review identifies differences and similarities of WQA protocols in use and discusses their strengths and weaknesses through: (i) a systematic comparison of WQA protocols by selected attributes, (ii) a review of real-life cases reported in the literature and expert interviews, and (iii) an illustration of our main findings by applying selected WQA in an instructive example. The review discusses differences in structure and concept, which are mainly identified for simplistic WQA protocols. The application of selected protocols to an example case shows a wide variety of numerical results and conclusive decisions. It is found that existing protocols target different questions within the decision making process, which users should be more aware of. Generally, to make assessments more reliable, further fundamental research is required to fully understand the relationship between stressors and stream ecosystem responses which will make assessments more reliable. Technically, tools suggested in WQA protocols show severe deficiencies and an uncertainty assessment should be mandatory.


Assuntos
Tomada de Decisões , Monitoramento Ambiental/métodos , Humanos , Qualidade da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA