Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Front Cardiovasc Med ; 9: 888825, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35620516

RESUMO

Background: Congenital left atrial appendage aneurysm (LAAA) is a rare cardiac anomaly with a variety of presentations, from being asymptomatic to potentially serious complications such as systemic thromboembolism and atrial tachyarrhythmia. Case Presentation: We report a case of congenital giant LAAA in a 35-year-old man presenting with acute massive cerebral infarction and atrial fibrillation (AF) with rapid ventricular rate. The AF was refractory to conventional antiarrhythmic agents, such as amiodarone and electrical cardioversion, but restored and maintained sinus rhythm after surgical resection of LAAA. The patient remained free of events and was in sinus rhythm during half-year follow-up. Conclusion: Giant LAAA has the potential causing serious complications and should be managed surgically in most cases.

2.
Curr Med Sci ; 41(2): 390-397, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33877558

RESUMO

The features and treatment of 98 Chinese patients with immunoglobulin G4 (IgG4)-related disease (IgG4-RD) referred to a single tertiary referring centre were reviewed. Patients diagnosed with IgG4-RD according to the comprehensive diagnostic criteria (CDC) were included in the retrospective study from May 2012 to March 2019. We collected data on clinical, laboratory, imaging, histological features and treatment. Totally, 98 patients with IgG4-RD were enrolled. The common clinical manifestations included abdominal pain, salivary gland swelling and lymphadenopathy. 51% of the patients had multiple organs involvement. Lymph nodes, pancreas and salivary glands were most commonly involved. Four rare sites including ulna, cerebellum, scalp, and mammary gland were found. The serum IgG4 level was increased by 85.7%. The serum IgG4 level was positively correlated with the number of involved organs, IgG and IgG4/IgG. Low C3 and C4 levels were observed in 37.5% and 12.2% patients respectively, and all patients with kidney involvement had hypocomplementemia. A total of 54 patients underwent tissue biopsies, and 55.6%, 31.5% and 11.1% cases were diagnosed as definite, probable and possible IgG4-RD, respectively. Eighty-eight patients received glucocorticoids (GCs) therapy. Five patients underwent radical surgery to remove the lesion. 73% of them presented a complete or partial remission. IgG4-RD is a systemic fibroinflammatory disease with involvement of multiple organs throughout the body including some rare sites. Most IgG4-RD patients had increased serum IgG4 levels and patients with kidney involvement showed hypocomplementemia. GCs therapy is effective. More research is needed to provide a more reliable basis for the diagnosis and treatment of patients.


Assuntos
Doença Relacionada a Imunoglobulina G4/diagnóstico , Doença Relacionada a Imunoglobulina G4/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , China , Complemento C3/metabolismo , Feminino , Humanos , Imunoglobulina G/sangue , Doença Relacionada a Imunoglobulina G4/sangue , Doença Relacionada a Imunoglobulina G4/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
3.
Curr Med Sci ; 41(5): 966-973, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34652628

RESUMO

OBJECTIVE: To comprehensively and accurately analyze the out-performance of low-dose chest CT (LDCT) vs. standard-dose CT (SDCT). METHODS: The image quality, size measurements and radiation exposure for LDCT and SDCT protocols were evaluated. A total of 117 patients with extra-thoracic malignancies were prospectively enrolled for non-enhanced CT scanning using LDCT and SDCT protocols. Three experienced radiologists evaluated subjective image quality independently using a 5-point score system. Nodule detection efficiency was compared between LDCT and SDCT based on nodule characteristics (size and volume). Radiation metrics and organ doses were analyzed using Radimetrics. RESULTS: The images acquired with the LDCT protocol yielded comparable quality to those acquired with the SDCT protocol. The sensitivity of LDCT for the detection of pulmonary nodules (n=650) was lower than that of SDCT (n=660). There was no significant difference in the diameter and volume of pulmonary nodules between LDCT and SDCT (for BMI <22 kg/m2, 4.37 vs. 4.46 mm, and 43.66 vs. 46.36 mm3; for BMI ≥22 kg/m2, 4.3 vs. 4.41 mm, and 41.66 vs. 44.86 mm3) (P>0.05). The individualized volume CT dose index (CTDIvol), the size specific dose estimate and effective dose were significantly reduced in the LDCT group compared with the SDCT group (all P<0.0001). This was especially true for dose-sensitive organs such as the lung (for BMI <22 kg/m2, 2.62 vs. 12.54 mSV, and for BMI ≥22 kg/m2, 1.62 vs. 9.79 mSV) and the breast (for BMI <22 kg/m2, 2.52 vs. 10.93 mSV, and for BMI ≥22 kg/m2, 1.53 vs. 9.01 mSV) (P<0.0001). CONCLUSION: These results suggest that with the increases in image noise, LDCT and SDCT exhibited a comparable image quality and sensitivity. The LDCT protocol for chest scans may reduce radiation exposure by about 80% compared to the SDCT protocol.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação
4.
Curr Med Sci ; 40(1): 178-183, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32166681

RESUMO

The effect of low voltage and low concentration contrast agent on image quality of coronary CT angiography, radiation dose and iodine intake was evaluated. A total of 121 patients with body mass index (BMI) <26 kg/m2 and heart rate (HR) <70 beats/min were randomly divided into four groups: group A (n=31, 80 kVp, 270 mgI/mL); group B (n=33, 100 kVp, 270 mgI/mL); group C (n=30, 100 kVp, 320 mgI/mL); group D (n=27, 100 kVp, 400 mgI/mL). The automatic current modulation system and the iterative algorithm for reconstruction were adopted in each group. The CT values and SD values of the aortic root (AR), subcutaneous fat, left coronary artery opening (LCA), and right coronary artery opening (RCA) were measured in all groups, the signal-to-noise ratio (SNR) and contrast noise ratio (CNR) were calculated, and effective radiation dose and iodine intake were recorded. The subjective assessment for image quality was performed by two physicians using a 4-point scale. The results were compared using the one-way ANOVA and rank sum tests. The image quality of the four groups met the clinical diagnostic requirements. The CT values of AR in groups A, B, C, and D were 537.6±71.4, 447.2±81.9, 445.2±64.9 and 518.5±94.9 Hu, respectively, with no significant difference between group A and group D, or between group B and group C, while CT values in groups B and C were significantly lower than those in groups A and D (P<0.05). In groups A, B, C, and D, the LCA SNR values were 22.7±9.1, 23.3±9.1, 23.3±7.7 and 26.6±8.9, and the RCA CNR values were 26.9±9.8, 28.5±11.4, 27.7±8.8 and 32.1±10.6, respectively. The AR visual scores in groups A, B, C and D were 3.8±0.2, 3.9±0.3, 3.9±0.3 and 4.0±0.3, respectively. There were no significant differences in SNR, CNR and visual score among the four groups (P>0.05). The radiation doses in groups A, B, C and D were 2.6±1.4, 3.6±1.8, 4.9±3.5 and 4.9±2.8 mSv, respectively. The radiation dose in group A was significantly less than that in the rest three groups (P<0.05). The iodine intakes in groups A, B, C and D were 14.9±1.5, 15.0±1.5, 17.7±2.0 and 18.1±2.5 g, respectively. There was no significant difference in the intake of iodine between groups C and D, or between groups A and B, while iodine intake in groups A and B were significantly reduced as compared with that in groups C and D (P<0.05). It was concluded that for patients with low BMI and controlled HR, compared to 100 kVp tube voltage combined with multiple concentration contrast agents, 80 kVp combined with 270 mgI/mL contrast agent is enough to ensure the quality of the images, and can reduce the radiation dose significantly, while reducing the amount of iodine intake notably, thus reducing the incidence of adverse reaction.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Ácidos Tri-Iodobenzoicos/administração & dosagem , Adulto , Idoso , Índice de Massa Corporal , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Intensificação de Imagem Radiográfica , Distribuição Aleatória , Razão Sinal-Ruído
5.
Curr Med Sci ; 38(5): 920-924, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30341530

RESUMO

In order to prospectively assess various parameters of diffusion weighted imaging (DWI) in differential diagnosis of benign and malignant solitary pulmonary nodules (SPNs), 58 patients (40 men and 18 women, and mean age of 48.1±10.4 years old) with SPNs undergoing conventional MR, DWI using b=500 s/mm2 on a 1.5T MR scanner, were studied. Various DWI parameters [apparent diffusion coefficient (ADC), lesion-tospinal cord signal intensity ratio (LSR), signal intensity (SI) score] were calculated and compared between malignant and benign SPNs groups. A receiver operating characteristic (ROC) curve analysis was employed to compare the diagnostic capabilities of all the parameters for discrimination between benign and malignant SPNs. The results showed that there were 42 malignant and 16 benign SPNs. The ADC was significantly lower in malignant SPNs (1.40±0.44)×10-3 mm2/s than in benign SPNs (1.81±0.58)×10-3 mm2/s. The LSR and SI scores were significantly increased in malignant SPNs (0.90±0.37 and 2.8±1.2) as compared with those in benign SPNs (0.68±0.39 and 2.2±1.2). The area under the ROC curves (AUC) of all parameters was not significantly different between malignant SPNs and benign SPNs. It was suggested that as three reported parameters for DWI, ADC, LSR and SI scores are all feasible for discrimination of malignant and benign SPNs. The three parameters have equal diagnostic performance.


Assuntos
Imagem de Difusão por Ressonância Magnética , Neoplasias Pulmonares/diagnóstico , Neoplasias/diagnóstico , Nódulo Pulmonar Solitário/diagnóstico , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/fisiopatologia , Curva ROC , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA