Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Eur J Clin Pharmacol ; 76(7): 969-977, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32363420

RESUMO

INTRODUCTION: Epidural hydromorphone could be useful in obstetric analgesia as there is a need for a more water-soluble opioid than sufentanil or fentanyl with prolonged analgesic effect. To our knowledge, the pharmacokinetics of epidural hydromorphone has not been evaluated in parturients. MATERIALS AND METHODS: In this pilot study, seven healthy parturients were given a single epidural dose of hydromorphone for labour pain. One parturient received 1.5 mg, two 0.75 mg and four 0.5 mg of hydromorphone hydrochloride. Dose was decreased due to nausea and pruritus. Hydromorphone's effect, adverse effects and plasma concentrations were evaluated. Neonatal drug exposure was evaluated by umbilical vein and artery opioid concentration at birth. Neonatal outcomes were assessed using Apgar and the Neurologic Adaptive Capacity Score (NACS). RESULTS: All patients received additional levobupivacaine doses on parturients' requests. The first dose was requested at a median of 163 min (range 19-303 min) after hydromorphone administration. A total of 12 opioid related expected adverse events were reported by seven parturients. All newborn outcomes were uneventful. Hydromorphone's distribution and elimination after single epidural dose seem similar to that reported for non-pregnant subjects after intravenous hydromorphone administration, but further research is required to confirm this observation. CONCLUSIONS: The optimal dose of hydromorphone in labour pain warrants further evaluation.


Assuntos
Analgésicos Opioides/farmacocinética , Hidromorfona/farmacocinética , Troca Materno-Fetal , Adulto , Analgesia Epidural/efeitos adversos , Analgesia Obstétrica/efeitos adversos , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Índice de Apgar , Feminino , Humanos , Hidromorfona/administração & dosagem , Hidromorfona/efeitos adversos , Recém-Nascido , Dor do Parto/tratamento farmacológico , Masculino , Projetos Piloto , Gravidez , Adulto Jovem
2.
Adv Exp Med Biol ; 975 Pt 2: 1021-1033, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28849519

RESUMO

Previously, we described the combined toxicity of taurine and alcohol, and assumed hypoglycemia to be one reason of this toxicity. To understand whether taurine-ethanol combined toxicity is exclusively connected to taurine or whether other inhibitory amino acids may have similar effects when combined with ethanol, we tested different doses of gamma-aminobutyric acid (GABA) in combination with ethanol in 7-day-old mice. The minimal dose of GABA in combination with 5 g/kg ethanol which could kill a mouse was 2 g/kg. GABA combined with ethanol at doses of 3 g/kg, 4 g/kg, 6 g/kg induced lethality of 30%, 90% and 100%, correspondingly. Taurine at the doses of 4 and 6 g/kg combined with ethanol induced death in 60 and 100% of mice. Ethanol (5 g/kg), taurine (6 g/kg), GABA (4 g/kg) administered alone and the combination of ethanol (5 g/kg) with taurine (3 g/kg) have no lethal effects. GABA (6 g/kg) applied alone induced 90% lethality. Taurine or GABA alone decreased blood glucose in a dose-depending manner. Ethanol potentiated GABA- and taurine-induced decrease in blood glucose and in some animals it dropped from 8.8 (intact) to a hypoglycemic level 3.1-3.3 mmol/L (GABA 4 g/kg, taurine 6 g/kg), but this may not be considered a single reason of death. We conclude that the combination of GABA and ethanol has a lethal effect and this is stronger than the combined toxicity of ethanol and taurine.


Assuntos
Glicemia/efeitos dos fármacos , Etanol/toxicidade , Taurina/toxicidade , Ácido gama-Aminobutírico/toxicidade , Animais , Feminino , Masculino , Camundongos
3.
Artigo em Inglês | MEDLINE | ID: mdl-39147721

RESUMO

BACKGROUND: Prenatal alcohol exposure (PAE) is one of the leading causes of preventable developmental disabilities. A lack of objective screening methods results in an under-recognition of the phenomenon. Phosphatidylethanol (PEth) is a specific ethanol biomarker that reveals alcohol intake up to several weeks after alcohol use. So far, PEth has mostly been a tool for detecting moderate and heavy drinking. With lower PEth cut-offs, revealing even minor prenatal alcohol consumption is possible. We aimed to find out if a sensitive method for PEth analysis would give additional information about PAE and to assess the cut-off value for a positive alcohol result in prenatal screening. METHODS: The study was an observational study of 3000 anonymous blood samples collected from the Helsinki University Hospital Diagnostic Center between June and September 2023. The Finnish Red Cross Blood Service received the samples originally for blood group typing and antibody screening as part of the prenatal blood screening program. We developed a sensitive PEth 16:0/18:1 analysis method using ultra-high-performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) equipment after liquid-liquid extraction of PEth from whole blood. The lower limit of quantification was 1 ng/mL. RESULTS: PEth was ≥2 ng/mL in 5.2% of the cases, ≥8 ng/mL in 2.0%, and ≥20 ng/mL in 1.0%. The detection time of PEth can be several weeks, especially with low PEth concentrations and after heavy alcohol consumption. It remained unknown whether the positive PEth tests resulted from drinking deliberately during pregnancy or before pregnancy recognition. CONCLUSIONS: We suggest adding PEth 16:0/18:1 to a routine prenatal blood screening program with a cut-off of 2 ng/mL-and in positive cases, clinical evaluation and retesting in 2-4 weeks. In clinical settings, information on gestational week and alcohol consumption before pregnancy is relevant and needs to be considered when interpreting low PEth concentrations.

4.
Drug Test Anal ; 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37933709

RESUMO

Among several established indicators that are used to monitor the illicit drug scene, drug-related deaths and wastewater-based epidemiology (WBE) stand out for population-level coverage. In this study, we aimed to compare temporal trends with respect to amphetamine, methamphetamine and methylenedioxymethamphetamine (MDMA) revealed by these indicators and explore the differences in fatal toxicity between the stimulants. All deaths in which poisoning caused by amphetamine, methamphetamine or MDMA was either the underlying or contributing cause of death in Finland in 2012, 2014, 2016, 2018 and 2020 were included in the study. Consumption of the studied drugs was measured by WBE in the same years. There was a significant correlation between poisoning and drug consumption for all three stimulants, and for amphetamine and MDMA, these figures increased over the study period. The highest fatal toxicity, as expressed by the number of deaths per million doses, was obtained for methamphetamine at an estimated dose of 50 mg, followed by MDMA (100 mg dose) and with amphetamine (50 mg dose). The fatal toxicity found here for the stimulants was close to that previously reported for many prescription opioids and tricyclic antidepressants. Our study is the first to quantitatively investigate the fatal toxicity of amphetamine-type stimulants by comparing deaths with consumption estimates derived from WBE. It shows that amphetamine, methamphetamine and MDMA possess a quite similar capacity to cause death. This new approach adds to the earlier methods of estimating drug-related harm.

5.
Nordisk Alkohol Nark ; 40(2): 160-175, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37063821

RESUMO

Background: We analysed illicit stimulant use in Finland by comparing three separate datasets collected at the same time. Methods: The data used were wastewater analysis (2014 and 2018), population-based drug surveys (2014 and 2018) and European Web Survey on Drugs (2018, Finnish data). Proportions, prevalence levels and trends of stimulant use as well as their consumption were measured. Factors associated with stimulant use were assessed for past-year stimulant or amphetamine use as an outcome measure in regression analyses. Results: Both population-based drug survey and wastewater data showed that stimulant use has increased in Finland between 2014 and 2018. Disadvantaged socio-demographic background and other substance use were associated with past-year stimulant use, with no geographical variation in Finland. The socio-demographics of those reporting amphetamine use differed between population-based drug survey and web survey. In the web survey, infrequent and occasional users of amphetamine were quite alike, whereas frequent users were more likely to be unemployed or use injection as the route of administration. Conclusion: Analysis of three different data revealed findings that would have been missed and conclusions that could not have been made by using only one dataset. Putting findings from different methods into dialogue raises new questions and opens new interpretations. This analysis emphasises the importance of the prevention of frequent use and associated harm, as well as the impact of versatile drug treatment and harm reduction services on it.

6.
Int J Legal Med ; 125(5): 675-83, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20652713

RESUMO

This study presents a retrospective performance evaluation of an on-site oral fluid drug screening device DrugWipe® 5/5+ (Securetec). The results obtained by the device were compared with gas chromatography-mass spectrometry confirmation analysis results in whole blood. Data used in the comparison were based on 1,807 real cases in which the Finnish police had conducted an on-site drug test on persons suspected of driving under the influence of drugs. The present data cover only cases wherein the DrugWipe device has shown a positive result for at least one substance. The data were compiled from the databases of Alcohol and Drug Analytics Unit at the National Institute for Health and Welfare. The performance of the DrugWipe was evaluated for its relevant drug groups: amphetamines, cannabis, opiates, and cocaine. The evaluation was carried out by calculating the sensitivity, specificity, and accuracy as well as the positive and negative predictive values. These calculations were based on the classification of the results as true positives, false positives, true negatives, and false negatives. Additionally, the demographics of the cases and analytical findings in whole blood are discussed. According to this study, the DrugWipe device performed quite well in detecting amphetamines, the most frequently encountered group of illicit drugs in Finnish traffic. The performance of the cannabis, opiate, and cocaine tests was not at the same level.


Assuntos
Drogas Ilícitas/análise , Saliva/química , Detecção do Abuso de Substâncias/legislação & jurisprudência , Detecção do Abuso de Substâncias/métodos , Adolescente , Adulto , Anfetaminas/análise , Cocaína/análise , Dronabinol/análise , Feminino , Finlândia , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Metanfetamina/análise , Pessoa de Meia-Idade , N-Metil-3,4-Metilenodioxianfetamina/análise , Entorpecentes/análise , Polícia , Valor Preditivo dos Testes , Adulto Jovem
7.
Int J Epidemiol ; 49(6): 1836-1846, 2021 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-32995840

RESUMO

BACKGROUND: Despite reporting lower levels of alcohol consumption, people with lower socio-economic status (SES) experience greater alcohol-related harm. Whether differential biases in the measurement of alcohol use could explain this apparent paradox is unknown. Using alcohol biomarkers to account for measurement error, we examined whether differential exposure to alcohol could explain the socio-economic differences in alcohol mortality. METHODS: Participants from eight representative health surveys (n = 52 164, mean age 47.7 years) were linked to mortality data and followed up until December 2016. The primary outcome was alcohol-attributable mortality. We used income and education as proxies for SES. Exposures include self-reported alcohol use and four alcohol biomarkers [serum gamma-glutamyl transferase (available in all surveys), carbohydrate-deficient transferrin, alanine aminotransferase and aspartate aminotransferase (available in subsamples)]. We used shared frailty Cox proportional hazards to account for survey heterogeneity. RESULTS: During a mean follow-up of 20.3 years, totalling 1 056 844 person-years, there were 828 alcohol-attributable deaths. Lower SES was associated with higher alcohol mortality despite reporting lower alcohol use. Alcohol biomarkers were associated with alcohol mortality and improved the predictive ability when used in conjunction with self-reported alcohol use. Alcohol biomarkers explained a very small fraction of the socio-economic differences in alcohol mortality, since hazard ratios either slightly attenuated (percent attenuation range 1.0-12.1%) or increased. CONCLUSIONS: Using alcohol biomarkers in addition to self-reported alcohol use did not explain the socio-economic differences in alcohol mortality. Differential bias in the measurement of alcohol use is not a likely explanation for the alcohol-harm paradox.


Assuntos
Consumo de Bebidas Alcoólicas , Classe Social , Consumo de Bebidas Alcoólicas/epidemiologia , Estudos de Coortes , Inquéritos Epidemiológicos , Humanos , Renda , Pessoa de Meia-Idade
8.
Sci Total Environ ; 770: 145274, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-33513496

RESUMO

Wastewater-based surveillance of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is used to monitor the population-level prevalence of the COVID-19 disease. In many cases, due to lockdowns or analytical delays, the analysis of wastewater samples might only be possible after prolonged storage. In this study, the effect of storage conditions on the RNA copy numbers of the SARS-CoV-2 virus in wastewater influent was studied and compared to the persistence of norovirus over time at 4 °C, -20 °C, and -75 °C using the reverse-transcription quantitative PCR (RT-qPCR) assays E-Sarbeco, N2, and norovirus GII. For the first time in Finland, the presence of SARS-CoV-2 RNA was tested in 24 h composite influent wastewater samples collected from Viikinmäki wastewater treatment plant, Helsinki, Finland. The detected and quantified SARS-CoV-2 RNA copy numbers of the wastewater sample aliquots taken during 19-20 April 2020 and stored for 29, 64, and 84 days remained surprisingly stable. In the stored samples, the SARS betacoronavirus and SARS-CoV-2 copy numbers, but not the norovirus GII copy numbers, seemed slightly higher when analyzed from the pre-centrifuged pellet-that is, the particulate matter of the influent-as compared with the supernatant (i.e., water fraction) used for ultrafiltration, although the difference was not statistically significant. Furthermore, when wastewater was spiked with SARS-CoV-2, linear decay at 4 °C was observed on the first 28 days, while no decay was visible within 58 days at -20 °C or -75 °C. In conclusion, freezing temperatures should be used for storage when immediate SARS-CoV-2 RNA analysis from the wastewater influent is not possible. Analysis of the particulate matter of the sample, in addition to the water fraction, can improve the detection frequency.


Assuntos
COVID-19 , SARS-CoV-2 , Biomarcadores , Controle de Doenças Transmissíveis , Finlândia , Humanos , RNA Viral , Águas Residuárias
9.
Int J Drug Policy ; 95: 103130, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33487529

RESUMO

BACKGROUND AND AIMS: Injecting drug use is a matter of public health concern, associated with risks of overdoses, addiction and increased risk of bloodborne viral transmissions. Self-reported data on substances injected can be inaccurate or subject to bias or drug users might be oblivious to their injected substances or adulterations. Gathering of robust analytical information on the actual composition of substances injected might provide better information about the drugs that are being used. Therefore, this study aimed to analyse the residual content of discarded syringes collected across 7 European cities, collectively called the European Syringe Collection and Analysis Project Enterprise (ESCAPE). METHODS: Used syringes were collected at street automatic injection kit dispensers or at harm-reduction services in Amsterdam, Budapest, Cologne, Glasgow, Helsinki, Lausanne and Paris. Two sampling periods were executed thus far, in 2017 and 2018. Qualitative chemical analysis of the content of used syringes was performed combining gas chromatographic (GC) and ultra(high)performance liquid chromatographic ((U)HPLC) analytical techniques with detection by mass spectrometry (MS). RESULTS: Substances detected most frequently across both campaigns were cocaine, heroin, buprenorphine, amphetamines and synthetic cathinones. In Amsterdam, Cologne, Lausanne and Glasgow heroin and cocaine were the psychoactive substances most often detected, often in conjunction with each other. Helsinki showed a high presence of buprenorphine and amphetamines. In Budapest and Paris, synthetic cathinones were frequently detected. Less synthetic cathinones and cocaine was detected in 2018, whereas buprenorphine was detected almost twice as much. Inner-city variations were found, probably reflecting the types of people who inject drugs (PWID) in different areas of the city. CONCLUSION: Overall, laboratory-confirmed local data on injected substances showed resemblance to national surveys done among PWID. However, the ESCAPE data also showed some interesting differences, showing it can be used for local interventions and complementing existing monitoring data.


Assuntos
Usuários de Drogas , Infecções por HIV , Abuso de Substâncias por Via Intravenosa , Cidades , Europa (Continente) , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Abuso de Substâncias por Via Intravenosa/epidemiologia , Seringas
10.
Addiction ; 115(1): 109-120, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31642141

RESUMO

BACKGROUND AND AIMS: Wastewater-based epidemiology is an additional indicator of drug use that is gaining reliability to complement the current established panel of indicators. The aims of this study were to: (i) assess spatial and temporal trends of population-normalized mass loads of benzoylecgonine, amphetamine, methamphetamine and 3,4-methylenedioxymethamphetamine (MDMA) in raw wastewater over 7 years (2011-17); (ii) address overall drug use by estimating the average number of combined doses consumed per day in each city; and (iii) compare these with existing prevalence and seizure data. DESIGN: Analysis of daily raw wastewater composite samples collected over 1 week per year from 2011 to 2017. SETTING AND PARTICIPANTS: Catchment areas of 143 wastewater treatment plants in 120 cities in 37 countries. MEASUREMENTS: Parent substances (amphetamine, methamphetamine and MDMA) and the metabolites of cocaine (benzoylecgonine) and of Δ9 -tetrahydrocannabinol (11-nor-9-carboxy-Δ9 -tetrahydrocannabinol) were measured in wastewater using liquid chromatography-tandem mass spectrometry. Daily mass loads (mg/day) were normalized to catchment population (mg/1000 people/day) and converted to the number of combined doses consumed per day. Spatial differences were assessed world-wide, and temporal trends were discerned at European level by comparing 2011-13 drug loads versus 2014-17 loads. FINDINGS: Benzoylecgonine was the stimulant metabolite detected at higher loads in southern and western Europe, and amphetamine, MDMA and methamphetamine in East and North-Central Europe. In other continents, methamphetamine showed the highest levels in the United States and Australia and benzoylecgonine in South America. During the reporting period, benzoylecgonine loads increased in general across Europe, amphetamine and methamphetamine levels fluctuated and MDMA underwent an intermittent upsurge. CONCLUSIONS: The analysis of wastewater to quantify drug loads provides near real-time drug use estimates that globally correspond to prevalence and seizure data.


Assuntos
Monitoramento Ambiental/métodos , Drogas Ilícitas , Análise Espaço-Temporal , Detecção do Abuso de Substâncias/métodos , Águas Residuárias/química , Anfetamina/análise , Cromatografia Líquida , Cocaína/análogos & derivados , Cocaína/análise , Humanos , Internacionalidade , Metanfetamina/análise , N-Metil-3,4-Metilenodioxianfetamina/análise , Espectrometria de Massas em Tandem
11.
Ther Drug Monit ; 31(4): 511-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19571773

RESUMO

In recent years, the interest in the use of oral fluid as a biological matrix has increased significantly, particularly for detecting driving under the influence of drugs (DUID). In this study, the relationship between the oral fluid and the blood concentrations of drugs of abuse in drivers suspected of DUID is discussed. Blood and oral fluid samples were collected from drivers suspected of DUID or stopped during random controls by the police in Belgium, Germany, Finland, and Norway for the ROSITA-2 project. The blood samples were analyzed by gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-mass spectrometry (LC-MS), sometimes preceded by immunoassay screening of blood or urine samples. The oral fluid samples were analyzed by GC-MS or LC-MS(/MS). Scatter plots and trend lines of the blood and oral fluid concentrations and the median, mean, range, and SD of the oral fluid to blood (OF:B) ratios were calculated for amphetamines, benzodiazepines, cocaine, opiates, and Delta(9)-2 tetrahydrocannabinol. The ratios found in this study were comparable with those that were published previously, but the range was wider. The OF:B ratios of basic drugs such as amphetamines, cocaine, and opiates were >1 [amphetamine: median (range) 13 (0.5-182), methylenedioxyamphetamine: 4 (1-15), methylenedioxymethamphetamine: 6 (0.9-88), methamphetamine: 5 (2-23), cocaine: 22 (4-119), benzoylecgonine: 1 (0.2-11), morphine: 2 (0.8-6), and codeine: 10 (0.8-39)]. The ratios for benzodiazepines were very low, as could be expected as they are highly protein bound and weakly acidic, leading to low oral fluid concentrations [diazepam: 0.02 (0.01-0.15), nordiazepam: 0.04 (0.01-0.23), oxazepam: 0.05 (0.03-0.14), and temazepam: 0.1 (0.06-0.54)]. For tetrahydrocannabinol, an OF:B ratio of 15 was found (range 0.01-569). In this study, the time of last administration, the dose, and the route of administration were unknown. Nevertheless, the data reflect the variability of the OF:B ratios in drivers thought to be under the influence of drugs. The wide range of the ratios, however, does not allow reliable calculation of the blood concentrations from oral fluid concentrations.


Assuntos
Anfetaminas/toxicidade , Detecção do Abuso de Substâncias/métodos , Transtornos Relacionados ao Uso de Substâncias/fisiopatologia , Condução de Veículo , Codeína/toxicidade , Dronabinol/toxicidade , Toxicologia Forense , Humanos
12.
Drug Test Anal ; 11(9): 1412-1418, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31140750

RESUMO

Urine samples were analyzed for lactose to investigate if elevated lactose concentrations indicate recent (< 48 hours) intravenous abuse of substances containing lactose as an excipient. Elevated lactose levels were found in samples given by patients who had recently injected substances intravenously, verified by fresh injection marks. Urine lactose assay can support clinical and toxicological findings when assessing substance abuse.


Assuntos
Buprenorfina/urina , Lactose/urina , Entorpecentes/urina , Abuso de Substâncias por Via Intravenosa/urina , Adulto , Ensaios Enzimáticos/métodos , Excipientes/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Detecção do Abuso de Substâncias/métodos , Adulto Jovem
13.
J Anal Toxicol ; 32(6): 393-401, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18652744

RESUMO

Nine different oral fluid (OF) collection devices were studied to evaluate their suitability for collecting samples for drug analysis. The devices were Greiner Bio-One, Orasure Intercept, Immunalysis Quantisal, StatSure Saliva.Sampler, Cozart, Sarstedt Salivette, Malvern Medical OraCol, Acro Biotech Salicule, and Varian OraTube. For comparison, OF was also collected into plastic tubes. The volume of collected OF was quantified for samples collected both in vitro and from volunteers. Drug recovery was studied by collecting OF fortified at 1000 ng/mL with amphetamine, 3,4-methylenedioxymethamphetamine, cocaine, Delta(9)-tetrahydrocannabinol, morphine, codeine, diazepam, and alprazolam with the devices in vitro and analyzing the samples with gas chromatography-mass spectrometry. Recovery of ethanol was measured from 0.2% in OF by headspace gas chromatography-flame-ionization detection. The stability of drugs in the samples was studied by analyzing the samples after 0, 14, and 28 days storage. The study shows that there are substantial differences between the OF collection devices on the market. Some are well suited for collecting samples for toxicological analysis, but some give quite poor results.


Assuntos
Saliva/química , Manejo de Espécimes/instrumentação , Detecção do Abuso de Substâncias/instrumentação , Soluções Tampão , Cromatografia Gasosa-Espectrometria de Massas , Humanos
14.
Sci Total Environ ; 627: 1039-1047, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29426122

RESUMO

Wastewater-based epidemiology is an efficient way to assess illicit drug use, complementing currently used methods retrieved from different data sources. The aim of this study is to compare stimulant drug use in five Nordic capital cities that include for the first time wastewater samples from Torshavn in the Faroe Islands. Currently there are no published reports that compare stimulant drug use in these Nordic capitals. All wastewater samples were analyzed using solid phase extraction and ultra-high performance liquid chromatography coupled to tandem mass spectrometry. The results were compared with data published by the European Monitoring Centre for Drugs and Drug Addiction based on illicit drugs in wastewater from over 50 European cities. Confirming previous reports, the results showed high amphetamine loads compared with other European countries. Very little apparent abuse of stimulant drugs was detected in Torshavn. Methamphetamine loads were the highest from Helsinki of the Nordic countries, indicating substantial fluctuations in the availability of the drug compared with previous studies. Methamphetamine loads from Oslo confirmed that the use continues to be high. Estimated cocaine use was found to be in the lower range compared with other cities in the southern and western part of Europe. Ecstasy and cocaine showed clear variations between weekdays and weekends, indicating recreational use. This study further demonstrates geographical trends in the stimulant drug market in five Nordic capitals, which enables a better comparison with other areas of the continent.


Assuntos
Monitoramento Ambiental , Drogas Ilícitas/análise , Águas Residuárias/química , Poluentes Químicos da Água/análise , Cidades , Dinamarca , Europa (Continente) , Países Escandinavos e Nórdicos , Detecção do Abuso de Substâncias , Transtornos Relacionados ao Uso de Substâncias/epidemiologia
15.
J Chromatogr A ; 1166(1-2): 171-80, 2007 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-17727863

RESUMO

Innovative features and technical improvements in modern bench-top quadrupole gas chromatograph-mass spectrometer (GC-MS) have prepared the way for faster and more cost-effective applications while still maintaining sufficient chromatographic resolution, speed of MS data acquisition and reliability of analytical methodology. In this paper, a short wide-bore capillary column with low film thickness (5 m x 0.32 mm i.d., 0.1 microm) was used a pre-fractionating column and only chosen heart-cuts were transferred to the second chromatographic dimension (15 m x 0.25 mm i.d., 0.25 microm) by means of a pressure-adjusted continual flow type switching device for quantification of five common amphetamine-type stimulant drugs. The instrumental setting used, in combination with carefully optimized operational fast GC and MS parameters, markedly decreased the retention times of the targeted analytes, e.g., amphetamine 0.891 min and methamphetamine 1.037 min, and the total chromatographic runtime (1.700 min), as well as reducing the need for continuous cleaning of the MS ion source and increasing column life compared with conventional GC-MS approaches. The performance of the instrumental configuration and analytical method was evaluated in validation experiments and the method was also applied to authentic samples. The method demonstrates the potential of fast GC-MS in combination with a gas-phase microfluidic Deans switch device for analysing of (semi)volatile compounds, such as amphetamine-type stimulant (ATS) drugs. This should be particularly useful in modern laboratories aiming at cost-efficient analysis as well as the optimum use of available laboratory capacity and instrumentation.


Assuntos
Anfetaminas/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Reprodutibilidade dos Testes
16.
J Anal Toxicol ; 31(5): 276-80, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17579972

RESUMO

This study investigated amphetamine concentrations in both oral fluid and whole blood samples of persons suspected of driving under the influence of drugs. The data for the study were obtained from 153 cases. The mean volume of oral fluid collected with the Intercept oral fluid collection device was 224 microL. Because of the small sample volume of oral fluid, the results of the amphetamine concentrations in oral fluid were not used in the calculations for 39 cases. The total number of cases positive for amphetamine in oral fluid was 100 out of 114. In seven cases the oral fluid sample was positive (cutoff 25 microg/L), even though the whole blood sample was negative (cutoff 20 microg/L). All of the cases found positive in whole blood (n = 93) were also positive in oral fluid. Oral fluid would therefore be well suited as a testing matrix for amphetamine when driving under the influence is suspected. The results nevertheless indicated that the cutoff used for amphetamine in oral fluid (i.e., 25 microg/L) could be higher to correspond to the window of detection given by the level of 20 microg/L in whole blood.


Assuntos
Anfetaminas/análise , Anfetaminas/sangue , Condução de Veículo , Entorpecentes/análise , Entorpecentes/sangue , Saliva/química , Detecção do Abuso de Substâncias/métodos , Adulto , Feminino , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
17.
J Mass Spectrom ; 41(6): 741-54, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16645997

RESUMO

Fast gas chromatography/negative-ion chemical ionization mass spectrometric (GC/NICI-MS) assay combined with rapid and nonlaborious sample preparation is presented for the simultaneous determination of benzodiazepines and alpha-hydroxy metabolites, zaleplon and zopiclone in whole blood. The compounds were extracted from 100 microl of whole blood by simultaneous multitube, microscale liquid-liquid extraction (LLE) and derivatized by N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), without the need for the time-consuming concentration stage. In the analytical separation, various parameters of fast GC/NICI-MS were applied, e.g. the use of hydrogen as a GC carrier gas, a high carrier gas velocity, a small film thickness of the analytical column, fast MS data acquisition, fast temperature ramping, and high initial and final temperatures of GC column. Sensitive identification, screening and quantitation of 18 compounds of interest were achieved in chromatographic separation in only 4.40 min. Accurate and reproducible results were obtained by using five different and carefully selected deuterated analogues on the basis of the chemical properties of the target analytes. Nevertheless, for alpha-OH-midazolam, and for bromazepam and flunitrazepam at low concentrations, the results can be considered only semiquantitative on the basis of the validation data. The extraction efficiencies ranged from 74.3 to 105.7% and the limits of quantitation (LOQ) from 1 to 100 ng ml(-1). Rapid sample preparation and fast chromatographic separation allowed cost-efficient, reliable and high sample-throughput analyses with a low amount of manual work. The method was fully validated and accredited according to EN ISO/IEC 17025 standards and is applicable for sensitive, reliable and quantitative determination of benzodiazepines, zaleplon and zopiclone, e.g. in clinical and forensic toxicology.


Assuntos
Acetamidas/sangue , Benzodiazepinas/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microquímica/métodos , Piperazinas/sangue , Pirimidinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Compostos Azabicíclicos , Análise Química do Sangue/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes/métodos , Fatores de Tempo
18.
Sci Total Environ ; 568: 864-874, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27335163

RESUMO

No single measure is able to provide a complete picture of population- or community-level drug abuse and its current trends. Therefore, a multi-indicator approach is needed. The aim of this study was to combine wastewater-based epidemiology (WBE) with data from other national indicators, namely driving under the influence of drugs (DUID) statistics, drug seizures, and drug use surveys. Furthermore, drug market size estimates and a comparison of confiscated drugs to drugs actually consumed by users were performed using the WBE approach. Samples for wastewater analysis were collected during one-week sampling periods in 2012, 2014 and 2015, with a maximum of 14 cities participating. The samples were analysed with a validated ultra-high-performance liquid chromatography-mass spectrometric (UHPLC-MS/MS) methodology for various common drugs of abuse. The results were then compared with data from other national indicators available. Joint interpretation of the data shows that the use of amphetamine and MDMA has increased in Finland from 2012 to 2014. A similar trend was also observed for cocaine, although its use remains at a very low level compared to many other European countries. Heroin was practically absent from the Finnish drug market during the study period. The retail market for the most common stimulant drugs were estimated to have been worth EUR 70 million for amphetamine and around EUR 10 million for both methamphetamine and cocaine, in 2014 in Finland.


Assuntos
Drogas Ilícitas/análise , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , População Urbana/estatística & dados numéricos , Águas Residuárias/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida de Alta Pressão , Monitoramento Ambiental , Finlândia/epidemiologia , Humanos , Espectrometria de Massas em Tandem
19.
J Mass Spectrom ; 40(6): 739-53, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15806585

RESUMO

An analytical procedure was developed for the simultaneous sensitive identification, screening and quantitation of 30 drugs of abuse using 250 microl of human oral fluid. The method employs sequential mixed-mode solid-phase extraction (SPE), optimized derivative formation and long-column fast gas chromatography/electron impact mass spectrometry (GC/EI-MS). After sequential SPE elution, the most sensitive and stable derivatives were formed by taking careful account of the characteristics of the active functional groups and possible steric hindrances affecting derivatization chemistry. Amphetamine-type stimulant drugs were acylated with heptafluorobutyric anhydride, benzodiazepines and Delta(9)-tetrahydrocannabinol were silylated with N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide and benzoylecgonine, codeine, ethylmorphine, 6-monoacetylmorphine, morphine, pholcodine, buprenorphine and norbuprenorphine with N-methyl-N-(trimethylsilyl)trifluoroacetamide. In addition, the following analytes were included: methadone, cocaine, alprazolam, midazolam, fentanyl and zolpidem. In GC separation, fast temperature ramping and high carrier gas flow-rate combined with long 30 m columns of i.d. 0.32 mm offered a reduction in analysis time and sharp peak shapes while still maintaining sufficient resolution and high sample capacity. Validated parameters including selectivity, linearity, accuracy, intra- and inter-day precision, extraction efficiency and limit of quantitation were all within required limits. In contrast to previously published methods, this single procedure is suitable for the simultaneous toxicological determination of the most common illicit drugs and benzodiazepines, and also zolpidem, in a small amount of oral fluid.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Drogas Ilícitas/análise , Saliva/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Detecção do Abuso de Substâncias/métodos , Toxicologia/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Artigo em Inglês | MEDLINE | ID: mdl-15734157

RESUMO

The most common commercially available silylating reagents, N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA), N,O-bis-(trimethylsilyl)trifluoroacetamide+1% trimethylchlorosilane (BSTFA+1% TMCS) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) were evaluated to achieve optimal derivatization conditions for analyzing various benzodiazepines based on gas chromatography-electron impact ionization-mass spectrometry (GC-EI-MS). Sensitivity, repeatability, retention times and stability of the derivatives, as well as specificity of mass fragmentation, were studied in detail. Also other parameters affecting the derivatization chemistry of benzodiazepines are discussed. tert-Butyldimethylsilyl (TBDMS) derivatives proved to be more stable, reproducible and sensitive than corresponding trimethylsilyl (TMS) derivatives for the GC-EI-MS analysis of benzodiazepines. Based on the TBDMS derivatives, a rapid, reliable, sensitive and quantitative GC-MS method was developed for the determination of 14 benzodiazepines and two hydroxy metabolites, as well as two non-benzodiazepine hypnotic agents, zolpidem and zaleplon, using 50 microl of whole blood. The method was completely validated in terms of accuracy, intra- and interday precision, limit of detection (LOD), limit of quantitation (LOQ), linearity, selectivity and extraction efficiency; these were all within the required limits, except for the accuracy of nitrazepam at a medium concentration level.


Assuntos
Acetamidas/sangue , Benzodiazepinas/sangue , Fluoracetatos , Compostos de Organossilício/análise , Piridinas/sangue , Pirimidinas/sangue , Benzodiazepinas/isolamento & purificação , Estabilidade de Medicamentos , Cromatografia Gasosa-Espectrometria de Massas , Compostos de Organossilício/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ácido Trifluoracético/química , Compostos de Trimetilsilil/química , Zolpidem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA