1.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671381

RESUMO

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Assuntos
Lentes Intraoculares , Acuidade Visual , Humanos , Estudos Prospectivos , Acuidade Visual/fisiologia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Facoemulsificação , Refração Ocular/fisiologia , Implante de Lente Intraocular , Desenho de Prótese , Período Pós-Operatório , Pseudofacia/fisiopatologia , Óptica e Fotônica
2.
Molecules ; 29(16)2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39202909

RESUMO

Ultra-fine dry powder extinguishing agent (UDPEA) is a promising alternative to Halon agents in aviation firefighting. The formulation of UDPEAs should balance environmental friendliness and practical engineering requirements, including high extinguishing efficiency, excellent flowability, and prolonged anti-reignition. This study investigates the effects of three modification methods (single perfluorooctyl triethoxysilane (FOTS), single N-(3-Triethoxysilylpropyl)perfluoro(2,5-dimethyl-3,6-dioxanonanoyl)amide (PFPE), and a combination of FOTS and PFPE at various mass ratios (2.0:0.4, 1.6:0.8, 1.2:1.2, 0.8:1.6, 0.4:2.0) (g)) on the performance of sodium bicarbonate-based UDPEA. The results indicate that using FOTS or PFPE alone improves the water and oil contact angles, but still fails to meet the required hydrophobicity and oleophobicity standards, and it also reduces the flowability and fire-extinguishing capability. A combination of FOTS and PFPE at the 1:2 ratio yields the best performance, with the water and oil contact angles of 145.169° and 143.542°, respectively, the lowest flowability index (0.224), minimal extinguishing concentration and time (14.183 g/m3 and 1.976 s, respectively), which is only 52.7% and 68.3% of those of the unmodified UDPEA's (26.927 g/m3 and 2.893 s), and the longest anti-reignition time (68.5 s). In addition, the fire-extinguishing mechanisms (chemical inhibition and physical heat absorption) and anti-reignition mechanisms of the modified UDPEA (with the FOTS to PFPE ratio of 1:2) were revealed. This research aims to design an eco-friendly, high-performance UDPEA as an effective substitute for Halon extinguishing agents. These findings can provide valuable insights for evaluating and selecting aviation fire-extinguishing agents.

3.
Int J Ophthalmol ; 17(7): 1273-1282, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39026905

RESUMO

AIM: To evaluate the trending visual performance of different intraocular lenses (IOLs) over time after implantation. METHODS: Ninety-one patients received cataract surgery with implantations of monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs, and extended-depth-of-focus (EDoF) IOLs were included. The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared. RESULTS: Most of the visual parameters improved over the postoperative 6mo. The postoperative visual acuity (POVA) of the Mon IOL, SegRef IOL, and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group. Nevertheless, the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo. The optical quality initially improved in the EDoF IOL group, then in the Mon IOL, SegRef IOL, and Dif IOL groups. POVA and objective visual performance of the Mon IOL and EDoF IOL groups, as well as POVA and visual quality of the Dif IOL group, improved in the postoperative 1mo and stabilized. Within the postoperative 6mo, gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group, as well as in the postoperative optical quality of the Dif IOL group. CONCLUSION: The visual performance is different among eyes implanted with different IOLs. The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution.

4.
Transl Vis Sci Technol ; 12(10): 15, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37847201

RESUMO

Purpose: To assess the impact of tear film on postoperative visual acuity after cataract surgery to implant an intraocular lens (IOL). Methods: Tear break-up time (TBUT), Schirmer I test, objective scatter index (OSI), and uncorrected distance visual acuity (UCDVA), intermediate visual acuity (UCIVA), and near visual acuity (UCNVA) were collected 6 months after cataract surgery. Results: Fifteen eyes with monofocal (Mo-) IOLs and 15 eyes with multifocal (Mu-) IOLs from 30 subjects were included. The Mu-IOL group exhibited higher baseline OSI (1.92 ± 0.69, P < 0.001). Negative correlations-both groups: tear film-related OSI (TF-OSI) and TBUT/Schirmer I test; Mo-IOL: TBUT and logMAR UCDVA-and positive correlations-both groups: TF-OSI and baseline OSI, baseline OSI/TF-OSI and logMAR UCDVA; Mu-IOL: baseline OSI/TF-OSI and logMAR UCIVA/UCNVA-were found. Linear regression showed associations between TF-OSI and TBUT (Mo-IOL: R2 = 0.455, P = 0.006; Mu-IOL: R2 = 0.454, P = 0.006)/Schirmer I test (Mo-IOL: R2 = 0.527, P = 0.002; Mu-IOL: R2 = 0.266, P = 0.049). Multiple regression showed associations between baseline OSI (Mo-IOL: R2 = 0.309, P = 0.032; Mu-IOL: R2 = 0.305, P = 0.033)/TF-OSI (Mo-IOL: R2 = 0.332, P = 0.025; Mu-IOL: R2 = 0.523, P = 0.002)/TBUT (Mo-IOL only: R2 = 0.315, P = 0.029) and logMAR UCDVA. Conclusions: TF-OSI reflects the UCDVA performance in eyes with IOLs and facilitates a better understanding of the effects of the tear film. Translational Relevance: TF-OSI offers a developmental and objective approach to assessing the changing visual performance caused by tear film after cataract surgery and IOL implantation in clinical practices.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Multifocais , Humanos , Implante de Lente Intraocular/efeitos adversos , Acuidade Visual
5.
Can Respir J ; 2022: 9656278, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311545

RESUMO

Background: Eosinophils were common inflammatory cells involved in the occurrence and development of various inflammatory diseases. Multiple recent studies have pointed to the increasingly important role of eosinophils in respiratory diseases. This article aims to compare the expression differences of blood eosinophil counts between asthma, chronic obstructive pulmonary disease (COPD), and asthma-COPD overlap (ACO). Methods: Patients with asthma, COPD, and ACO who were seen in the First Affiliated Hospital of Guangzhou Medical University from January 2012 to June 2019 were included. We collected information such as age, gender, diagnosis, the eosinophil counts from the medical records. Moreover, the levels of 10 cytokines in the plasma of each group were detected by using the Meso Scale Discovery method. Results: We included 9787 patients with asthma, 15806 patients with COPD, and 831 ACO patients. From our results, it can be first found that eosinophil levels were age-related in the three diseases (asthma and ACO: p < 0.001; COPD: P = 0.001); in asthma and COPD, the number of eosinophils in males was more significant than that in females (asthma: p < 0.001; COPD: p = 0.012). Second, asthma patients had higher blood eosinophil counts than those with COPD and ACO (p < 0.001). Moreover, we found out that eosinophil levels were highly expressed in the stable group of all three diseases. Finally, we found that most cytokines in ACO patients showed a downward trend when the level of eosinophils was low, whereas the results were reversed in asthma patients; 7 cytokines had similar trends in COPD and ACO patients. Conclusions: In conclusion, eosinophils have their own unique endotypes in asthma, COPD, and ACO patients, which were reflected in the fluctuation of their levels and changes in cytokine secretion.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Masculino , Feminino , Humanos , Eosinófilos , Asma/epidemiologia , Contagem de Leucócitos , Citocinas