1.
J Appl Clin Med Phys ; 22(8): 45-59, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34275176

RESUMO

PURPOSE: To develop and implement an acceptance procedure for the new Elekta Unity 1.5 T MRI-linac. METHODS: Tests were adopted and, where necessary adapted, from AAPM TG106 and TG142, IEC 60976 and NCS 9 and NCS 22 guidelines. Adaptations were necessary because of the atypical maximum field size (57.4 × 22 cm), FFF beam, the non-rotating collimator, the absence of a light field, the presence of the 1.5 T magnetic field, restricted access to equipment within the bore, fixed vertical and lateral table position, and the need for MR image to MV treatment alignment. The performance specifications were set for stereotactic body radiotherapy (SBRT). RESULTS: The new procedure was performed similarly to that of a conventional kilovoltage x-ray (kV) image guided radiation therapy (IGRT) linac. Results were acquired for the first Unity system. CONCLUSIONS: A comprehensive set of tests was developed, described and implemented for the MRI-linac. The MRI-linac met safety requirements for patients and operators. The system delivered radiation very accurately with, for example a gantry rotation locus of isocenter of radius 0.38 mm and an average MLC absolute positional error of 0.29 mm, consistent with use for SBRT. Specifications for clinical introduction were met.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Humanos , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
2.
J Appl Clin Med Phys ; 16(6): 508-514, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699571

RESUMO

Constancy checks of a well-type ionization chamber should be performed regularly as part of a quality assurance regime. The goal of this work was to test the feasibility of using a linear accelerator and an orthovoltage unit to check the constancy of a well-type chamber's response to an external radiation source. The reproducibility, linearity with dose, variation with dose-rate, and variation between energy-matched units of the well-type chamber response when exposed to 6 MV beams was examined. The robustness to errors in establishing the measurement conditions, including setting the source-to-surface distance and gantry angle, rotation of the chamber around the central axis of the beam, and the effect of changing the length of the chamber cable exposed to the field, were tested. The reproducibility and linearity with dose of the chamber response, and robustness to errors in establishing the measurement conditions for 100 kVp and 250 kVp beams from an orthovoltage unit, were also examined. The combined uncertainty, including contributions from errors in establishing the reference conditions, for well-type chamber measurements using a 6 MV beam from a linear accelerator is 1.0%. The combined uncertainties for measurements using 100 and 250 kVp beams were 1.8% and 1.5%, respectively. When focus-source distance errors were reduced to ≤ 1 mm, the combined uncertainties for the 100 and 250 kVp beams were 1.2% and 1.1%, respectively, when the dose to the chamber was confined to the linear region of the dose-response curve. The response of a well-type chamber should remain constant to within 1.2% when exposed to a constant dose from an external beam unit, if reference conditions can be reproducibly established. However, the uncertainty for establishing reference conditions for output measurements for an orthovoltage unit can be reduced, which would justify a reduction of the tolerance for constancy measurements.


Assuntos
Radiometria/instrumentação , Radioterapia de Alta Energia/estatística & dados numéricos , Radioterapia de Alta Energia/normas , Calibragem , Humanos , Aceleradores de Partículas/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/normas , Radiometria/estatística & dados numéricos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes
3.
Gerontologist ; 64(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37351950

RESUMO

BACKGROUND AND OBJECTIVES: Disaster preparedness is an urgent concern, particularly for caregivers of persons with dementia. Developing and executing plans for oneself and another person who needs care can be difficult when the care recipient is cognitively impaired. We sought to better understand caregivers' disaster preparedness for the purpose of generating guidance for future interventions to increase caregiver resilience. RESEARCH DESIGN AND METHODS: We conducted a qualitative descriptive study of caregiver disaster experiences and perceptions of their preparedness. Fifty-two participants from diverse backgrounds participated in a focus group or interview. Deductive thematic data analysis was utilized to identify themes. Stress process models guided the interpretation of our findings. RESULTS: Analyses of caregivers' experiences and observations revealed that disaster preparedness was challenging for caregivers, though also perceived to be an important responsibility. We identified 3 main themes: (a) barriers to preparing for a disaster as a caregiver for a person living with dementia, (b) why it is important for a caregiver to develop a disaster plan, and (c) how to facilitate preparedness for caregivers of persons living with dementia. DISCUSSION AND IMPLICATIONS: This study highlighted the difficulties of preparing for a disaster while caring for a person with dementia. Applying stress process models to our results provided strong evidence that interventions could be developed to bolster caregivers' resources to cope with stressors associated with disaster preparedness. A key issue for public officials is the question of whether disaster shelters are appropriate for persons with dementia.


Assuntos
Demência , Planejamento em Desastres , Resiliência Psicológica , Humanos , Cuidadores , Pesquisa Qualitativa
4.
Phys Imaging Radiat Oncol ; 30: 100580, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38707627

RESUMO

Background and purpose: MRI-guided online adaptive treatments can account for interfractional variations, however intrafraction motion reduces treatment accuracy. Intrafraction plan adaptation methods, such as the Intrafraction Drift Correction (IDC) or sub-fractionation, are needed. IDC uses real-time automatic monitoring of the tumor position to initiate plan adaptations by repositioning segments. IDC is a fast adaptation method that occurs only when necessary and this method could enable margin reduction. This research provides a treatment planning evaluation and experimental validation of the IDC. Materials and methods: An in silico treatment planning evaluation was performed for 13 prostate patients mid-treatment without and with intrafraction plan adaptation (IDC and sub-fractionation). The adaptation methods were evaluated using dose volume histogram (DVH) metrics. To experimentally verify IDC a treatment was mimicked whereby a motion phantom containing an EBT3 film moved mid-treatment, followed by repositioning of segments. In addition, the delivered treatment was irradiated on a diode array phantom for plan quality assurance purposes. Results: The planning study showed benefits for using intrafraction adaptation methods relative to no adaptation, where the IDC and sub-fractionation showed consistently improved target coverage with median target coverages of 100.0%. The experimental results verified the IDC with high minimum gamma passing rates of 99.1% and small mean dose deviations of maximum 0.3%. Conclusion: The straightforward and fast IDC technique showed DVH metrics consistent with the sub-fractionation method using segment weight re-optimization for prostate patients. The dosimetric and geometric accuracy was shown for a full IDC workflow using film and diode array dosimetry.

5.
J Appl Clin Med Phys ; 14(4): 4249, 2013 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-23835391

RESUMO

This study evaluated the agreement of fiducial marker localization between two modalities--an electronic portal imaging device (EPID) and cone-beam computed tomography (CBCT)--using a low-dose, half-rotation scanning protocol. Twenty-five prostate cancer patients with implanted fiducial markers were enrolled. Before each daily treatment, EPID and half-rotation CBCT images were acquired. Translational shifts were computed for each modality and two marker-matching algorithms, seed-chamfer and grey-value, were performed for each set of CBCT images. The localization offsets, and systematic and random errors from both modalities were computed. Localization performances for both modalities were compared using Bland-Altman limits of agreement (LoA) analysis, Deming regression analysis, and Cohen's kappa inter-rater analysis. The differences in the systematic and random errors between the modalities were within 0.2 mm in all directions. The LoA analysis revealed a 95% agreement limit of the modalities of 2 to 3.5 mm in any given translational direction. Deming regression analysis demonstrated that constant biases existed in the shifts computed by the modalities in the superior-inferior (SI) direction, but no significant proportional biases were identified in any direction. Cohen's kappa analysis showed good agreement between the modalities in prescribing translational corrections of the couch at 3 and 5 mm action levels. Images obtained from EPID and half-rotation CBCT showed acceptable agreement for registration of fiducial markers. The seed-chamfer algorithm for tracking of fiducial markers in CBCT datasets yielded better agreement than the grey-value matching algorithm with EPID-based registration.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Marcadores Fiduciais , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Algoritmos , Equipamentos e Provisões Elétricas , Humanos , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Rotação
6.
J Appl Gerontol ; 42(7): 1565-1573, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36905348

RESUMO

COVID-19 regulations have posed challenges for long-term care (LTC). However, few studies have examined how such regulations influenced the care of residents living with dementia. Our objective was to gain an understanding of LTC administrative leaders' perceptions regarding the impact of the COVID-19 response on this population. Using the convoys of care framework, we conducted a qualitative descriptive study. Forty-three participants, representing 60 LTC facilities, completed one interview where they described how COVID-19 policies shaped care for residents living with dementia. Results from deductive thematic analysis revealed that participants believed the care convoys of residents living with dementia were strained. Participants emphasized how diminished family involvement, increased staff responsibilities, and the industry's heightened regulatory climate contributed to disrupted care. Further, they highlighted how pandemic-focused safety guidelines did not always consider the unique needs of those living with dementia. Consequently, this study may inform policy by outlining considerations for future emergencies.


Assuntos
COVID-19 , Demência , Humanos , Assistência de Longa Duração , Instituições de Cuidados Especializados de Enfermagem , Demência/terapia
7.
Phys Imaging Radiat Oncol ; 28: 100507, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38035206

RESUMO

Background and purpose: Radiotherapy plan verification is generally performed on the reference plan based on the pre-treatment anatomy. However, the introduction of online adaptive treatments demands a new approach, as plans are created daily on different anatomies. The aim of this study was to experimentally validate the accuracy of total doses of multi-fraction plan adaptations in magnetic resonance imaging guided radiotherapy in a phantom study, isolated from the uncertainty of deformable image registration. Materials and methods: We experimentally verified the total dose, measured on external beam therapy 3 (EBT3) film, using a treatment with five online adapted fractions. Three series of experiments were performed, each focusing on a category of inter-fractional variation; translations, rotations and body modifications. Variations were introduced during each fraction and adapted plans were generated and irradiated. Single fraction doses and total doses over five online adapted fractions were investigated. Results: The online adapted measurements and calculations showed a good agreement for single fractions and multi-fraction treatments for the dose profiles, gamma passing rates, dose deviations and distances to agreement. The gamma passing rate using a 2%/2 mm criterion ranged from 99.2% to 99.5% for a threshold dose of 10% of the maximum dose (Dmax) and from 96.2% to 100% for a threshold dose of 90% of Dmax, for the total translations, rotations and body modifications. Conclusions: The total doses of multi-fraction treatments showed similar accuracies compared to single fraction treatments, indicating an accurate dosimetric outcome of a multi-fraction treatment in adaptive magnetic resonance imaging guided radiotherapy.

8.
Med Phys ; 50(1): 397-409, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36210631

RESUMO

BACKGROUND: Lung stereotactic body radiotherapy (SBRT) has proven an effective treatment for medically inoperable lung tumors, even for (ultra-)central tumors. Recently, there has been growing interest in radiation-induced cardiac toxicity in lung radiotherapy. More specifically, dose to cardiac (sub-)structures (CS) was found to correlate with survival after radiotherapy. PURPOSE: Our goal is first, to investigate the percentage of patients who require CS sparing in an magnetic resonance imaging guided lung SBRT workflow, and second, to quantify how successful implementation of cardiac sparing would be. METHODS: The patient cohort consists of 34 patients with stage II-IV lung cancer who were treated with SBRT between 2017 and 2020. A mid-position computed tomography (CT) image was used to create treatment plans for the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) following clinical templates. Under guidance of a cardio-thoracic radiologist, 11 CS were contoured manually for each patient. Dose constraints for five CS were extracted from the literature. Patients were stratified according to their need for cardiac sparing depending on the CS dose in their non-CS constrained MR-linac treatment plans. Cardiac sparing treatment plans (CSPs) were then created and dosimetrically compared with their non-CS constrained treatment plan counterparts. CSPs complied with the departmental constraints and were considered successful when fulfilling all CS constraints, and partially successful if some CS constraints could be fulfilled. Predictors for the need for and feasibility of cardiac sparing were explored, specifically planning target volume (PTV) size, cranio-caudal (CC) distance, 3D distance, and in-field overlap volume histograms (iOVH). RESULTS: 47% of the patients (16 out of 34) were in need of cardiac sparing. A successful CSP could be created for 62.5% (10 out of 16) of these patients. Partially successful CSPs still complied with two to four CS constraints. No significant difference in dose to organs at risk (OARs) or targets was identified between CSPs and the corresponding non-CS constrained MR-linac plans. The need for cardiac sparing was found to correlate with distance in the CC direction between target and all of the individual CS (Mann-Whitney U-test p-values <10-6 ). iOVHs revealed that complying with dose constraints for CS is primarily determined by in-plane distance and secondarily by PTV size. CONCLUSION: We demonstrated that CS can be successfully spared in lung SBRT on the MR-linac for most of this patient cohort, without compromising doses to the tumor or to other OARs. CC distance between the target and CS can be used to predict the need for cardiac sparing. iOVHs, in combination with PTV size, can be used to predict if cardiac sparing will be successful for all constrained CS except the left ventricle.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Estudos de Viabilidade , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Pulmão , Imageamento por Ressonância Magnética/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco
9.
Radiother Oncol ; 189: 109932, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37778533

RESUMO

This work reports on the first seven patients treated with gating and baseline drift correction on the high-field MR-Linac system. Dosimetric analysis showed that the active motion management system improved congruence to the planned dose, efficiently mitigating detrimental effects of intrafraction motion in the upper abdomen.


Assuntos
Neoplasias Abdominais , Radioterapia de Intensidade Modulada , Humanos , Movimento , Movimento (Física) , Radiometria , Neoplasias Abdominais/radioterapia , Planejamento da Radioterapia Assistida por Computador
10.
J Gerontol B Psychol Sci Soc Sci ; 77(12): 2317-2325, 2022 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-35976106

RESUMO

OBJECTIVES: The hierarchical mapping technique (HMT) is used to study social convoys, peoples' support systems. Recent research integrating the HMT and the continuing bonds framework suggests that deceased persons may be influential convoy members. Extending this idea, the current study aimed to gain insight regarding how older conjugally bereaved women view the role of a deceased romantic partner in their convoy. METHODS: The study utilized a qualitative descriptive approach. Twenty heterosexual women (mean age = 78 years, range = 65-93 years), recruited via social media and snowball sampling, participated in one 90-min interview. Each discussed their bereavement journey and completed an HMT diagram to comment on how, if at all, their deceased romantic partner was part of their social convoy and their place within it. RESULTS: Fifteen of the 20 women placed the deceased in the innermost circle of the diagram, with them yet separate from other convoy members. Thematic analysis of transcripts revealed 5 major themes: "We're part of each other," "I think he supports me," "He would want me to be happy," "I just feel so grateful," and "I think about him every day but I don't talk about him every day." DISCUSSION: Perceptions that deceased romantic partners continue to play a key role in conjugally bereaved older women's lives offer researchers the unique opportunity to examine how loss is carried into old age. Furthermore, this study may assist with the development of interventions that destigmatize continuing bond expressions for conjugally bereaved heterosexual women.


Assuntos
Luto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos
11.
Radiother Oncol ; 174: 149-157, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35817325

RESUMO

BACKGROUND AND PURPOSE: VMAT is not currently available on MR-linacs but could maximize plan conformality. To mitigate respiration without compromising delivery efficiency, MRI-guided MLC tumour tracking was recently developed for the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) in combination with IMRT. Here, we provide a first experimental demonstration of VMAT + MLC tracking for several lung SBRT indications. MATERIALS AND METHODS: We created central patient and phantom VMAT plans (8×7.5 Gy, 2 arcs) and we created peripheral phantom plans (3×18 & 1×34 Gy, 4 arcs). A motion phantom mimicked subject-recorded respiratory motion (A‾=11 mm, f‾=0.33 Hz, drift‾=0.3 mm/min). This was monitored using 2D-cine MRI at 4 Hz to continuously realign the beam with the target. VMAT + MLC tracking performance was evaluated using 2D film dosimetry and a novel motion-encoded and time-resolved pseudo-3D dosimetry approach. RESULTS: We found an MLC leaf and jaw end-to-end latency of 328.05(±3.78) ms and 317.33(±4.64) ms, which was mitigated by a predictor. The VMAT plans required maximum MLC speeds of 12.1 cm/s and MLC tracking superimposed an additional 1.48 cm/s. A local 2%/1 mm gamma analysis with a static measurement as reference, revealed pass-rates of 28-46% without MLC tracking and 88-100% with MLC tracking for the 2D film analysis. Similarly, the pseudo-3D gamma passing-rates increased from 22-77% to 92-100%. The dose area histograms showed that MLC tracking increased the GTV D98% by 5-20% and the PTV D95% by 7-24%, giving similar target coverage as their respective static reference. CONCLUSION: MRI-guided VMAT + MLC tracking is technically feasible on the MR-linac and results in highly conformal dose distribution.


Assuntos
Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Imageamento por Ressonância Magnética , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos
12.
Phys Imaging Radiat Oncol ; 23: 24-31, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35923896

RESUMO

Background and purpose: Central lung tumours can be treated by magnetic resonance (MR)-guided radiotherapy. Complications might be reduced by decreasing the Planning Target Volume (PTV) using mid-position (midP)-based planning instead of Internal Target Volume (ITV)-based planning. In this study, we aimed to verify a method to automatically derive patient-specific PTV margins for midP-based planning, and show dosimetric robustness of midP-based planning for a 1.5T MR-linac. Materials and methods: Central(n = 12) and peripheral(n = 4) central lung tumour cases who received 8x7.5 Gy were included. A midP-image was reconstructed from ten phases of the 4D-Computed Tomography using deformable image registration. The Gross Tumor Volume (GTV) was delineated on the midP-image and the PTV margin was automatically calculated based on van Herk's margin recipe, treating the standard deviation of all Deformation Vector Fields, within the GTV, as random error component. Dosimetric robustness of midP-based planning for MR-linac using automatically derived margins was verified by 4D dose-accumulation. MidP-based plans were compared to ITV-based plans. Automatically derived margins were verified with manually derived margins. Results: The mean D95% target coverage in GTV + 2 mm was 59.9 Gy and 62.0 Gy for midP- and ITV-based central lung plans, respectively. The mean lung dose was significantly lower for midP-based treatment plans (difference:-0.3 Gy; p < 0.042 ). Automatically derived margins agreed within one millimeter with manually derived margins. Conclusions: This retrospective study indicates that mid-position-based treatment plans for central lung Stereotactic Body Radiation Therapy yield lower OAR doses compared to ITV-based treatment plans on the MR-linac. Patient-specific GTV-to-PTV margins can be derived automatically and result in clinically acceptable target coverage.

13.
Med Phys ; 48(4): 1520-1532, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33583042

RESUMO

PURPOSE: The treatment margins for lung stereotactic body radiotherapy (SBRT) are often large to cover the tumor excursions resulting from respiration, such that underdosage of the tumor can be avoided. Magnetic resonance imaging (MRI)-guided multi-leaf collimator (MLC) tracking can potentially reduce the influence of respiration to allow for smaller treatment margins. However, tracking is accompanied by system latency that may induce residual tracking errors. Alternatively, a simpler mid-position delivery combined with trailing can be used. Trailing reduces influences of respiration by compensating for baseline motion, to potentially improve target coverage. In this study, we aim to show the feasibility of MRI-guided tracking and trailing to reduce influences of respiration during lung SBRT. METHODS: We implemented MRI-guided tracking on the MR-linac using an Elekta research tracking interface to track tumor motion during intensity modulated radiotherapy (IMRT). A Quasar MRI 4 D phantom was used to generate Lujan motion ( cos 4 , 4 s period, 20 mm peak-to-peak amplitude) with and without 1.0 mm/min cranial drift. Phantom tumor positions were estimated from sagittal 2D cine-MRI (4 or 8 Hz) using cross-correlation-based template matching. To compensate the anticipated system latency, a linear ridge regression predictor was optimized for online MRI by comparing two predictor training approaches: training on multiple traces and training on a single trace. We created 15-beam clinical-grade lung SBRT plans for central targets (8 × 7.5 Gy) and peripheral targets (3 × 18 Gy) with different PTV margins for mid-position based motion management (3-5 mm) and for MLC tracking (3 mm). We used a film insert with a 3 cm spherical target to measure the spatial distribution and quantity of the delivered dose. A 1%/1 mm local gamma-analysis quantified dose differences between motion management strategies and reference cases. Additionally, a dose area histogram (DAH) revealed the target coverage relative to the reference scenario. RESULTS: The prediction filter gain was on average 25% when trained on multiple traces and 44% when trained on a single trace. The filter reduced system latency from 313 ± 2 ms to 0 ± 5 ms for 4 Hz imaging and from 215 ± 3 ms to 3 ± 3 ms for 8 Hz. The local gamma analysis for the central delivery showed that tracking improved the gamma pass-rate from 23% to 96% for periodic motion and from 14% to 93% when baseline drift was applied. For the peripheral delivery during periodic motion, delivery pass-rates improved from 22% to 93%. Comparing mid-position delivery to trailing for periodic+drift motion increased the local gamma pass rate from 15% to 98% for a central delivery and from 8% to 98% for a peripheral delivery. Furthermore, the DAHs revealed a relative D 98 % GTV coverage of 101% and 97% compared to the reference scenario for, respectively, central and peripheral tracking of periodic+drift motion. For trailing, a relative D 98 % of 99% for central and 98% for peripheral trailing was found. CONCLUSIONS: We provided a first experimental demonstration of the technical feasibility of MRI-guided MLC tracking and trailing for central and peripheral lung SBRT. Tracking maximizes the sparing of healthy tissue, while trailing is highly effective in mitigating baseline motion.


Assuntos
Neoplasias Pulmonares , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Pulmão , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
14.
Front Oncol ; 11: 617681, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777759

RESUMO

Curative-intent radiotherapy plays an integral role in the treatment of lung cancer and therefore improving its therapeutic index is vital. MR guided radiotherapy (MRgRT) systems are the latest technological advance which may help with achieving this aim. The majority of MRgRT treatments delivered to date have been stereotactic body radiation therapy (SBRT) based and include the treatment of (ultra-) central tumors. However, there is a move to also implement MRgRT as curative-intent treatment for patients with inoperable locally advanced NSCLC. This paper presents the initial clinical experience of using the two commercially available systems to date: the ViewRay MRIdian and Elekta Unity. The challenges and potential solutions associated with MRgRT in lung cancer will also be highlighted.

15.
Trop Med Int Health ; 15(3): 342-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20070627

RESUMO

OBJECTIVE: Recent clinical studies have shown high rates of malaria treatment failure in endemic areas of Papua New Guinea (PNG), necessitating a change of treatment from chloroquine (CQ) or amodiaquine (AQ) plus sulphadoxine-pyrimethamine to the artemisinin combination therapy (ACT) artemether plus lumefantrine (LM). To facilitate the monitoring of antimalarial drug resistance in this setting, we assessed the in vitro sensitivity of Plasmodium falciparum isolates from Madang Province. METHODS: A validated colorimetric lactate dehydrogenase assay was used to assess growth inhibition of 64 P. falciparum isolates in the presence of nine conventional or novel antimalarial drugs [CQ, AQ, monodesethyl-amodiaquine (DAQ), piperaquine (PQ), naphthoquine (NQ), mefloquine (MQ), LM, dihydroartemisinin and azithromycin (AZ)]. RESULTS: The geometric mean (95% confidence interval) concentration required to inhibit parasite growth by 50% (IC(50)) was 167 (141-197) nM for CQ, and 82% of strains were resistant (threshold 100 nM), consistent with near-fixation of the CQ resistance-associated pfcrt allele in PNG. Except for AZ [8.351 (5.418-12.871) nM], the geometric mean IC(50) for the other drugs was <20 nM. There were strong associations between the IC(50)s of 4-aminoquinoline (CQ, AQ, DAQ and NQ), bisquinoline (PQ) and aryl aminoalcohol (MQ) compounds suggesting cross-resistance, but LM IC(50) only correlated with that of MQ. Conclusions Most PNG isolates are resistant to CQ in vitro but not to other ACT partner drugs. The non-isotopic semi-automated high-throughput nature of the Plasmodium lactate dehydrogenase assay facilitates the convenient serial assessment of local parasite sensitivity, so that emerging resistance can be identified with relative confidence at an early stage.


Assuntos
Antimaláricos/farmacologia , Plasmodium falciparum/efeitos dos fármacos , Amodiaquina/farmacologia , Artemisininas/farmacologia , Azitromicina/farmacologia , Criança , Pré-Escolar , Resistência a Múltiplos Medicamentos/genética , Feminino , Humanos , Lactente , Concentração Inibidora 50 , L-Lactato Desidrogenase/análise , Masculino , Mefloquina/farmacologia , Proteínas de Membrana Transportadoras/genética , Naftoquinonas/farmacologia , Plasmodium falciparum/genética , Plasmodium falciparum/crescimento & desenvolvimento , Proteínas de Protozoários/genética , Quinolinas/farmacologia , Níveis Máximos Permitidos
16.
Phys Med Biol ; 65(21): 215008, 2020 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-32698168

RESUMO

High impedance coils (HICs) are suitable as a building block of receive arrays for MRI-guided radiotherapy (MRIgRT) as HICs do not require radiation-attenuating capacitors and dense support materials. Recently, we proved the feasibility of using HICs to create a radiation transparent (i.e. radiolucent) window. In this work, we constructed a fully functional 32-channel array based on this design. The anterior element is flexible and follows the shape of the subject, while the posterior element is rigid to support the subject. Both elements feature a 2 × 8 channel layout. Here, we discuss the construction process and characterize the array's radiolucency and imaging performance. The dosimetric impact of the array was quantified by assessing the surface dose increase and attenuation of a single beam. The imaging performance of the prototype was compared to the clinical array in terms of visual appearance, signal-to-noise ratio (SNR), and acceleration performance, both in phantom and in-vivo measurements. Dosimetry measurements showed that on-body placement changed the anterior and posterior surface dose by +3% and -16% of the dose maximum. Attenuation under the anterior support materials and conductors was 0.3% and ≤1.5%, respectively. Phantom and in-vivo imaging with this array demonstrated an improvement of the SNR at the surface and the image quality in general. Simultaneous irradiation did not affect the SNR. G-factors were reduced considerably and clinically used sequences could be accelerated by up to 45%, which would greatly reduce pre-beam imaging times. Finally, the maximally achievable temporal resolution of abdominal 3D cine imaging was improved to 1.1 s, which was > 5 × faster than could be achieved with the clinical array. This constitutes a big step towards the ability to resolve respiratory motion in 3D. In conclusion, the proposed 32-channel array is compatible with MRIgRT and can significantly reduce scan times and/or improve the image quality of all on-line scans.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Aceleradores de Partículas , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Radiometria , Razão Sinal-Ruído
17.
Phys Med Biol ; 64(11): 115029, 2019 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-30808017

RESUMO

The out-of-field surface dose contribution due to backscattered or ejected electrons, focused by the magnetic field, is evaluated in this work. This electron streaming effect (ESE) can contribute to out-of-field skin doses in orthogonal magnetic resonance guided radiation therapy machines. Using the EGSnrc Monte Carlo package, a phantom is set-up along the central axis of an incident 10 [Formula: see text] 10 cm2 7 MV FFF photon beam. The phantom exit or entry surface is inclined with respect to the magnetic field, and an out-of-field water panel is positioned 10 cm away from, and centered on, the isocenter. The doses from streaming backscattered or ejected electrons, for either a 0.35 T or 1.5 T magnetic field, are evaluated in the out-of-field water panel for surface inclines of 10, 30, and 45°. The magnetic field focuses electrons emitted from the inclined phantom. Dose distributions at the surface of the out-of-field water panel are sharper in the 1.5 T magnetic field as compared to 0.35 T. The maximum doses for the 0.35 T simulations are 23.2%, 37.8%, and 39.0% for the respective 10, 30, and 45° simulations. For 1.5 T, for the same angles, the maximum values are 17.1%, 29.8%, and 35.8%. Dose values drop to below 2% within the first 1 cm of the out-of-field water phantom. The phantom thickness is an important variable in the magnitude of the ESE dose. The ESE can produce large out-of-field skin doses and must be a consideration in treatment planning in the MRgRT work-flow. Treatments often include multiple beams which will serve to spread out the effect, and many beams, such as anterior-posterior, will reduce the skin dose due to the ESE. A 1 cm thick shielding of either a bolus placed on the patient or mounted on the present RF coils would greatly reduce the ESE dose contributions. Further exploration of the capabilities of treatment planning systems to screen for this effect is required.


Assuntos
Elétrons , Campos Magnéticos , Método de Monte Carlo , Imagens de Fantasmas , Radioterapia Guiada por Imagem/normas , Pele/efeitos da radiação , Humanos
18.
Med Phys ; 46(3): 1467-1477, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30666678

RESUMO

PURPOSE: The purpose of this study was to evaluate the potential skin dose toxicity contribution of spiralling contaminant electrons (SCE) generated in the air in an MR-linac with a 0.35 or 1.5 T magnetic field using the EGSnrc Monte Carlo (MC) code. Comparisons to experimental results at 1.5 T are also performed. METHODS: An Elekta generated phase space file for the Unity MR-linac is used in conjunction with the EGSnrc enhanced electric and magnetic field transport macros to simulate surface dose profiles and depth-dose curves in panels located 5 cm away from the beam edge and positioned either parallel or perpendicular to the magnetic field. Electrons generated in the air will spiral along the magnetic field lines, and though surface doses within the field will be reduced, the electrons can contribute to out-of-field surface doses. RESULTS: Surface dose profiles showed good agreement with experimental findings and the maximum simulated doses at surfaces perpendicular to the magnetic field were 3.77 ± 0.01% and 3.55 ± 0.01% for 1.5 and 0.35 T. These results are expressed as a percentage of the maximum dose to water delivered by the photon beam. The surface dose variations in the out-of-field region converge to the 0 T doses within the first 0.5 cm of material. An asymmetry in the dose distribution in surfaces positioned on either side of the photon beam and aligned parallel to the magnetic field is determined to be due to the magnetic field directing electrons deeper into, or localizing them to the surface of, the measurement panel. CONCLUSIONS: These results confirm the SCE dose contribution in surfaces perpendicular to the magnetic field and show these doses to be of the order of a few percentage of the maximum dose to water of the beam. Good agreement in the dose profiles is seen in comparisons between the MC simulations and experimental work. The effect is apparent in 0.35 and 1.5 T magnetic fields and dissipates within the first few millimeters of material. It should be noted that only SCEs from beam anteriorly incident on the patient will influence the patient surface dose, and the use of beams incident over different angles will reduce the dose to any particular patient surface.


Assuntos
Elétrons , Campos Magnéticos , Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Pele/efeitos da radiação , Humanos
19.
Phys Med Biol ; 64(18): 185004, 2019 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-31370043

RESUMO

The lack of radiation-attenuating tuning capacitors in high impedance coils (HICs) make HICs an interesting building block of receive arrays for MRI-guided radiotherapy (MRIgRT). Additionally, their flexibility and limited channel coupling allow for low-density support materials, which are likely to be more radiation transparent (radiolucent). In this work, we introduce the use of HICs in receive arrays for MRIgRT treatments. We discuss the design and show the dosimetric feasibility of a HIC receive array that has a high channel count and aims to improve the imaging performance of the 1.5 T MR-linac. Our on-body design comprises an anterior and posterior element, which each feature a [Formula: see text] channel layout (32 channels total). The anterior element is flexible, while the posterior element is rigid to support the patient. Mockups consisting of support materials and conductors were built, irradiated, and optimized to minimize impact on the surface dose (7% of the dose maximum) and dose at depth ([Formula: see text]0.8% under a single conductor and [Formula: see text]1.4% under a conductor crossing). Anatomical motion and the use of multiple beam angles will ensure that these slight dose changes at depth are clinically insignificant. Subsequently, several functional, single-channel HIC imaging prototypes and a 5-channel array were built to assess the performance in terms of signal-to-noise ratio (SNR). The performance was compared to the clinical MR-linac array and showed that the 5-channel imaging prototype outperformed the clinical array in terms of SNR and channel coupling. Imaging performance was not affected by the radiation beam. In conclusion, the use of HICs allowed for the design of our flexible, on-body receive array for MRIgRT. The design was shown to be dosimetrically feasible and improved the SNR. Future research with a full array will need to show the gain in parallel imaging performance and thus acceleration.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética/instrumentação , Fenômenos Mecânicos , Aceleradores de Partículas/instrumentação , Impedância Elétrica , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
20.
Pract Radiat Oncol ; 9(3): 158-171, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30690085

RESUMO

PURPOSE: Incidental cardiac exposure during radiation therapy may cause heart disease. Dose-response relationships for cardiac structures (segments) may show which ones are most sensitive to radiation. Radiation-related cardiac injury can take years to develop; thus, studies need to involve women treated using 2-dimensional planning, with segment doses estimated using a typical computed tomography (CT) scan. We assessed whether such segment doses are accurate enough to use in dose-response relationships using the radiation therapy charts of women with known segment injury. We estimated interregimen and interpatient segment dose variability and segment dose correlations. METHODS AND MATERIALS: The radiation therapy charts of 470 women with cardiac segment injury after breast cancer radiation therapy were examined, and 41 regimens were identified. Regimens were reconstructed on a typical CT scan. Doses were estimated for 5 left ventricle (LV) and 10 coronary artery segments. Correlations between cardiac segments were estimated. Interpatient dose variation was assessed in 10 randomly selected CT scans for left regimens and in 5 for right regimens. RESULTS: For the typical CT scan, interregimen segment dose variation was substantial (range, LV segments <1-39 Gy; coronary artery segments <1-48 Gy). In 10 CT scans, interpatient segment dose variation was higher for segments near field borders (range, 3-47 Gy) than other segments (range, <2 Gy). Doses to different left-anterior descending coronary artery (LADCA) segments were highly correlated with each other, as were doses to different LV segments. Also, LADCA segment doses were highly correlated with doses to LV segments usually supplied by the LADCA. For individual regimens there was consistency in hotspot location and segment ranking of higher-versus-lower dose. CONCLUSIONS: The scope for developing quantitative cardiac segment dose-response relationships in patients who had 2-dimensional planning is limited because different segment doses are often highly correlated, and segment-specific dose uncertainties are not independent of each other. However, segment-specific doses may be reliably used to rank segments according to higher-versus-lower doses.


Assuntos
Neoplasias da Mama/radioterapia , Coração/efeitos da radiação , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador/efeitos adversos , Relação Dose-Resposta à Radiação , Estudos Epidemiológicos , Feminino , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X