RESUMO
PURPOSE: The aim of this study was to describe the 10-year findings from the UK National Ligament Registry (NLR). METHODS: A retrospective review was performed for prospectively collected data on the NLR between January 2013 and December 2022. All patients who underwent primary ACL reconstruction (ACLR) on the registry were included. Surgical characteristics were analysed, including surgeon grade and case volume, concomitant knee procedures, venous thromboembolic prophylaxis, graft characteristics, femoral and tibial tunnel drilling, and fixation methods. Clinical outcomes were collected preoperatively and at 6 months, 1 year, 2 years and 5 years following the index procedure. RESULTS: During the study period, 17,492 unilateral ACLR procedures were recorded. Autograft was used in 98%, most commonly a combined semitendinosus and gracilis graft (77%) or patella tendon graft (31%). Allograft was used in only 1% of the patients. In 52% of cases, ACLR was associated with an additional procedure, with isolated medial meniscal surgery being the most common (21%). Femoral tunnel drilling was mostly performed through an anteromedial portal (73%) and tibial tunnel drilling using an outside-in technique (92%). The most common method of femoral graft fixation was with an Endobutton fixed loop suspensory device (77%), while interference screws predominated for tibial tunnel fixation (86%). Patients who underwent ACLR surgery showed significant improvement in their functional outcome scores at six months, 1 year, 2 years and 5 years postoperatively. CONCLUSION: Data from the NLR shows a detailed description of the current trends and evolution of ACLR in the United Kingdom over the last 10 years. Satisfactory functional outcomes were observed 5 years postoperatively. This study provides useful information on the prevalence of ACL-associated injuries and current surgical techniques with the aim of improving the quality of clinical care and patients' outcomes. Moreover, it provides surgeons with a benchmark against which to compare current practices and functional outcomes following ACLR across the United Kingdom. LEVEL OF EVIDENCE: Level III.
Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Ligamento Patelar , Humanos , Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Ligamento Patelar/cirurgia , Sistema de RegistrosRESUMO
BACKGROUND: Preoperative planning in total hip arthroplasty (THA) involves utilizing radiographs or advanced imaging modalities, including computerized tomography scans, for precise prediction of implant sizing and positioning. This study aimed to compare 3-dimensional (3D) versus 2-dimensional (2D) preoperative planning in primary THA with respect to key surgical metrics, including restoration of the horizontal and vertical center of rotation (COR), combined offset, and leg length. METHODS: This study included 60 patients undergoing primary THA for symptomatic hip osteoarthritis (OA), randomly allocated to either robotic arm-assisted or conventional THA. Digital 2D templating and 3D planning using the robotic software were performed for all patients. All measurements to evaluate the accuracy of templating methods were conducted on the preoperative computerized tomography scanogram, using the contralateral hip as a reference. Sensitivity analyses explored differences between 2D and 3D planning in patients who had superolateral or medial OA patterns. RESULTS: Compared to 2D templating, 3D templating was associated with less medialization of the horizontal COR (-1.2 versus -0.2 mm, P = .002) and more accurate restoration of the vertical COR (1.63 versus 0.3 mm, P < .001) with respect to the contralateral side. Furthermore, 3D templating was superior for planned restoration of leg length (+0.23 versus -0.74 mm, P = .019). Sensitivity analyses demonstrated that in patients who had medial OA, 3D planning resulted in less medialization of horizontal COR and less offset reduction. Conversely, in patients who had superolateral OA, there was less lateralization of horizontal COR and less offset increase using 3D planning. Additionally, 3D planning showed superior reproducibility for stem, acetabular cup sizes, and neck angle, while 2D planning often led to smaller stem and cup sizes. CONCLUSIONS: Our findings indicated higher accuracy in the planned restoration of native joint mechanics using 3D planning. Additionally, this study highlights distinct variances between the 2 planning methods across different OA pattern subtypes, offering valuable insights for clinicians employing 2D planning.
Assuntos
Artroplastia de Quadril , Imageamento Tridimensional , Osteoartrite do Quadril , Cuidados Pré-Operatórios , Tomografia Computadorizada por Raios X , Humanos , Artroplastia de Quadril/métodos , Feminino , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Osteoartrite do Quadril/diagnóstico por imagem , Idoso , Cuidados Pré-Operatórios/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Prótese de Quadril , Procedimentos Cirúrgicos Robóticos/métodosRESUMO
Total knee arthroplasty continues to evolve. It is important to review some of the current controversies and hot topics in arthroplasty. Optimal knee alignment strategy is now just a matter of debate. Mechanical, kinematic, and functional alignment and the role of robotics in achieving optimum alignment are important topics, along with fixation and outpatient knee arthroplasty.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Osteoartrite do Joelho/cirurgiaRESUMO
BACKGROUND: Robotic-arm assisted total hip arthroplasty (RO THA) has been shown to improve the accuracy of component positioning compared with conventional total hip arthroplasty (CO THA). This study reports Patient-Reported Outcome Measures (PROMs) of a previous trial that showed that RO THA was associated with improved accuracy and reduced outliers in acetabular component positioning compared with CO THA. METHODS: This prospective cohort study included 50 patients undergoing CO THA versus 50 patients receiving RO THA. The Oxford hip score, Forgotten Joint Score (FJS), University of California at Los Angeles hip score were recorded at a minimum of 3 years following surgery. RESULTS: At minimum 3 years follow-up, there was no statistically significant difference in CO THA versus RO THA with respect to the Oxford hip score [median 42(6.25) versus 41(5.5), P = .914]; FJS [89 (9.25) versus 86 (9), P = .065], and University of California at Los Angeles score [median 7.5 (3) versus 7 (2), P = .381]. None of the study patients had dislocations or underwent revision surgery within 3 years follow-up. CONCLUSION: The previously reported improvement in accuracy of acetabular component in this study population did not translate to statistically significant improvements in PROMs. Patients in both groups achieved excellent PROMs and there was a trend towards higher FJS scores postoperatively in the RO THA group that did not reach statistical significance. Further studies are needed to assess the significance of these findings on longer-term clinical outcomes and implant survivorships, and also to explore the impact of the enhanced RO THA workflow and functional implant positioning on these outcomes.
Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia de Quadril/métodos , Seguimentos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Resultado do Tratamento , Medidas de Resultados Relatados pelo PacienteRESUMO
BACKGROUND: In an effort to increase satisfaction among total knee arthroplasty (TKA) patients, emphasis has been placed on implant positioning and limb alignment. Traditionally, the aim for TKA has been to achieve a neutral mechanical alignment (MA) to maximize implant longevity. However, with the recent spike in interest in individualized alignment techniques and with the advent of new technologies, surgeons are slowly evolving away from classical MA. METHODS: This review elucidates the differences in alignment techniques for TKA, describes the concept of knee phenotypes, summarizes comparative studies between MA and individualized alignment, and provides a simple way to incorporate the latter into surgeons' practice. RESULTS: In order to manage patients by applying these strategies in day-to-day practice, a basic understanding of the aforementioned concepts is essential. Transition to an individualized alignment technique should be done gradually with caution in a stepwise approach. CONCLUSION: Alignment and implant positioning are now at the heart of the debate and surgeons are investigating a more personalized approach to TKA.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Fenômenos Biomecânicos , Articulação do Joelho/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/cirurgiaRESUMO
BACKGROUND: Cementless stem designs with proximal metaphyseal fixation aim to achieve better load distribution, reduce stress shielding, and improve primary stability. The purpose of this prospective, randomized controlled trial was to evaluate the 2-year migration and clinical outcomes of two cementless femoral stems. METHODS: A total of 60 participants undergoing primary total hip arthroplasty for any cause were randomly allocated to receiving either a proximally coated, short blade stem or a quadrangular-taper stem with a reinforced proximal body. Radiostereometric analysis radiographs were performed postoperatively and at 6 weeks, 6 months, 1 year and 2 years. The Harris Hip Score, Oxford Hip Score and the EuroQol five-dimension were also collected. RESULTS: At two years, the median subsidence of the short-blade stem was 0.097 millimeters (mm) [Interquartile range (IQR) -0.67 to 0.08)] versus 0.086 mm(IQR, -0.29 to 0.005, P = .683); medial translation 0.023 mm (IQR 0.08 to 0.12) versus 0.029 mm(IQR -0.07 to 0.10, P = .907); anterior translation 0.035 mm (IQR -0.23 to 0.33) versus 0.07 mm (IQR -0.13 to 0.08, P = .268). At 24 months postoperatively, there were no stem revisions and Patient-Reported Outcome Measures (PROMs) were comparable between groups. CONCLUSION: Both cementless stems exhibited a predictable migration pattern and achieved initial stability. There was no difference in migration across the three Cartesian axes at any time point. Clinical outcomes and PROMs were also comparable. Biological fixation of both implants evidenced by the radiostereometric analysis and excellent PROMs are likely to translate to longer-term stability, which would need to be corroborated by longer-term outcome studies.
Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Análise Radioestereométrica , Estudos Prospectivos , Desenho de Prótese , Artroplastia de Quadril/métodos , Falha de Prótese , Resultado do Tratamento , SeguimentosRESUMO
INTRODUCTION: Accurate implant positioning, tailored to the phenotype and unique biomechanics of each patient is the single most important objective in achieving stability in THA and maximise range of motion. The spine-pelvis-hip construct functions as a single unit adapting to postural changes. It is widely accepted in the literature that no universaltarget exists and variations in spinopelvic mobility mandate adjustments to the surgical plan; thus bringing to the fore the concept of personalised, functional component positioning. METHODS: This manuscript aims to outline the challenges posed by spinopelvic imbalance and present a reproducible, stepwise approach to achieve functional-component positioning. We also present the one-year functional outcomes and Patient Reported Outcome Measures of a prospective cohort operated with this technique. RESULTS AND CONCLUSION: Robotic-arm assisted Total Hip Arthroplasty has facilitated enhanced planning based on the patient's phenotype and evidence suggests it results in more reproducible and accurate implant positioning. Preservation of offset, avoiding leg-length discrepancy, accurate restoration of the centre of rotation and accomplishing the combinedversion target are very important parameters in Total Hip Arthroplasty that affect post-operative implant longevity, patient satisfaction and clinical outcomes.
Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Satisfação do Paciente , PelveRESUMO
INTRODUCTION: As we now drive to reinitiate our full capacity elective services in an attempt to tackle an ever-growing demand for lower limb arthroplasty, this pandemic has presented rare opportunities to revise and re-engage elective arthroplasty pathways aimed at improving patient care and healthcare efficiency. AIMS: We present the development of an evidence-based multidisciplinary perioperative care pathway for day-case total knee arthroplasty (TKA) in a United Kingdom National Health Service (NHS) institution, in conjunction with a review of the literature upon which the protocol is founded. METHODOLOGY: We performed a review of the literature reporting complication or readmission rates at ≥30 day postoperative following day-case TKA. Electronic searches were performed using four databases from the date of inception to November 2020. Relevant studies were identified, data extracted, and qualitative synthesis performed. RESULTS: 13 manuscripts with a total of 3370 day-case TKAs, defined as discharged on the same-calendar-day of surgery, were included in analysis. Mean 90-day complication rates (8.31% [range, 0-16.3%] vs 9.49% [range, 0-13.1%], respectively) and readmission rates (2.71% [range, 0-10.0%] vs 3.41% [range, 0-9.9%], respectively) were equivocal between day-case and inpatient TKA. The overall rate of successful same-calendar-day discharge was 95.8%. Our evaluation and critique of the evidence-based literature identifies day-case TKA to be safe, effective and economical, benefitting both patients and healthcare systems alike. CONCLUSION: We further validate the introduction of our institutional Elective Day Surgery Arthroplasty Pathway (EDSAP) based on the evidence presented. Careful patient selection paralleled with well-defined care pathways are essential for successful introduction of day-case TKA into the NHS.
Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Atenção à Saúde , Hospitais , Humanos , Tempo de Internação , Readmissão do Paciente , Complicações Pós-Operatórias/etiologia , Medicina EstatalRESUMO
BACKGROUND: Implant malalignment may be a risk factor for poor patient-reported outcomes measures (PROMs) following total knee arthroplasty (TKA). METHODS: Postoperative surveys were administered to assess PROMs regarding satisfaction, pain, and function in 262 patients who underwent surgery at 4 centers in the U.S. and U.K (average age, 67.2) at a mean 5.5 years after primary TKA. Postoperative distal femoral angle (DFA), proximal tibial angle (PTA), and posterior tibial slope angle (PSA) were radiographically measured, and outliers were recorded. PROMs were compared between patients with aligned versus malaligned knees using univariate analysis. RESULTS: Patients with DFA, PTA, and PSA outliers were more likely to experience similar or decreased activity levels postoperatively than patients with no alignment outliers, as were patients with 1 or 2 outliers of any kind (P < .05). Patients with DFA, PTA, and PSA outliers were significantly more likely to be dissatisfied with their ability to perform activities of daily living (ADLs), as were patients with 1 or 2 outliers of any kind (P < .05). Patients with DFA and PSA outliers were more likely to be dissatisfied with their degree of pain relief, as were patients with 2 outliers of any kind (P < .05). Finally, patients with DFA and PSA outliers, as well as those with 1 outlier of any kind, were more likely to be dissatisfied with their overall knee function (P < .05). CONCLUSION: DFA, PTA, and PSA outliers represent a significant risk factor for decreased satisfaction with activities of daily living(ADLs), pain relief, and knee function, as well as decreased activity levels. LEVEL OF EVIDENCE: Level III.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Atividades Cotidianas , Idoso , Artroplastia do Joelho/efeitos adversos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Osteoartrite do Joelho/cirurgia , Dor/cirurgia , Medidas de Resultados Relatados pelo Paciente , Antígeno Prostático Específico , Fatores de RiscoRESUMO
Robotic-arm-assisted total hip arthroplasty (RoTHA) offers the opportunity to improve the implant positioning and restoration of native hip mechanics. The concept of individualised, functional implant positioning and how it relates to spinopelvic imbalance is an important yet rather novel consideration in THA. There is mounting evidence that a significant percentage of dislocations occur within the perceived "safe zones"; hence, in the challenging subset of patients with a stiff spinopelvic construct, it is imperative to employ individualised component positioning based on the patients' phenotype. Restoring the native centre of rotation, preserving offset, achieving the desired combined anteversion and avoiding leg length inequality are all very important surgeon-controlled variables that have been shown to be associated with postoperative outcomes. The latest version of the software has a feature of virtual range of motion (VROM), which preoperatively identifies potential dynamic causes of impingement that can cause instability. This review presents the workflow of RoTHA, especially focusing on pragmatic solutions to tackle the challenge of spinopelvic imbalance. Furthermore, it presents an overview of the existing evidence concerning RoTHA and touches upon future direction.
Assuntos
Artroplastia de Quadril , Procedimentos Cirúrgicos Robóticos , Fluxo de Trabalho , Braço , Amplitude de Movimento ArticularRESUMO
PURPOSE: The aim of this study was to investigate the clinical and radiological results of the MAKO CT-based robotic-assisted system for total knee arthroplasty (TKA). METHODS: A PRISMA systematic review was conducted using four databases (MEDLINE, EMBASE, Pubmed, GOOGLE SCHOLAR) to identify all clinical and radiological studies reporting information regarding the use and results of the CT-based robotic-assisted system to perform TKA between 2016 and 2020. The main investigated outcome criteria were postoperative pain, analgesia requirements, clinical scores, knee range of motion, implant positioning and the revision rate. The ROBINS-I tool (Risk Of Bias In Non-randomized Studies of Interventions) was used to evaluate the quality of included studies and the risk of bias. RESULTS: A total of 36 studies were identified, of which 26 met inclusion criteria. Of these 26 studies, 14 were comparative. The follow-up varied from 30 days to 17 months. This CT-based, saw cutting Robotic TKA is associated with a significantly lower postoperative pain score (2.6 versus 4.5) and with significantly reduced time to hospital discharge (77 h versus 105), compared with conventional TKA. The two comparative studies assessing functional outcomes at 1 year reported significantly better functional scores with CT-based robotic TKA compared with conventional TKA (WOMAC score: 6 ± 6 versus 9 ± 8 (p < 0.05); KSS function score: 80 versus 73 (p = 0.005)). Only three comparative studies assessed implant positioning, and these reported better implant positioning with CT-based robotic-assisted TKA. CONCLUSION: The CT-based robotic-assisted system for TKA reduced postoperative pain and improved implant positioning with equal or slightly superior improvement of the functional outcomes at one year, compared to conventional TKA. LEVEL OF EVIDENCE: Systematic review level IV.
Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tomografia Computadorizada por Raios XRESUMO
PURPOSE: The effect of bone marrow mesenchymal stromal cells (BMSCs) and platelet-rich plasma (PRP) on tendon allograft maturation in a large animal anterior cruciate ligament (ACL) reconstruction model was reported for the first time. It was hypothesised that compared with non-augmented ACL reconstruction, BMSCs and PRP would enhance graft maturation after 12 weeks and this would be detected using magnetic resonance imaging (MRI). METHODS: Fifteen sheep underwent unilateral tendon allograft ACL reconstruction using aperture fixation and were randomised into three groups (n = 5). Group 1 received 10 million allogeneic BMSCs in 2 ml fibrin sealant; Group 2 received 12 ml PRP in a plasma clot injected into the graft and bone tunnels; and Group 3 (control) received no adjunctive treatment. At autopsy at 12 weeks, a graft maturation score was determined by the sum for graft integrity, synovial coverage and vascularisation, graft thickness and apparent tension, and synovial sealing at tunnel apertures. MRI analysis (n = 2 animals per group) of the signal-noise quotient (SNQ) and fibrous interzone (FIZ) was used to evaluate intra-articular graft maturation and tendon-bone healing, respectively. Spearman's rank correlation coefficient (r) of SNQ, autopsy graft maturation score and bone tunnel diameter were analysed. RESULTS: The BMSC group (p = 0.01) and PRP group (p = 0.03) had a significantly higher graft maturation score compared with the control group. The BMSC group scored significantly higher for synovial sealing at tunnel apertures (p = 0.03) compared with the control group. The graft maturation score at autopsy significantly correlated with the SNQ (r = - 0.83, p < 0.01). The tunnel diameter of the femoral tunnel at the aperture (r = 0.883, p = 0.03) and mid-portion (r = 0.941, p = 0.02) positively correlated with the SNQ. CONCLUSIONS: BMSCs and PRP significantly enhanced graft maturation, which indicates that orthobiologics can accelerate the biologic events in tendon allograft incorporation. Femoral tunnel expansion significantly correlated with inferior maturation of the intra-articular graft. The clinical relevance of this study is that BMSCs and PRP enhance allograft healing in a translational model, and biological modulation of graft healing can be evaluated non-invasively using MRI.
Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Células-Tronco Mesenquimais , Plasma Rico em Plaquetas , Aloenxertos , Animais , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Ovinos , Tendões/cirurgiaRESUMO
BACKGROUND: The medial-pivot (MP) design for total knee arthroplasty (TKA) aims to restore more natural "ball-and-socket" knee kinematics compared to the traditional posterior-stabilized (PS) implants for TKA. The objective of this study is to determine if there was any difference in functional outcomes between patients undergoing MP-TKA vs PS-TKA. METHODS: This prospective randomized controlled trial consisted of 43 patients undergoing MP-TKA vs 45 patients receiving a single-radius PS-TKA design. The primary outcome was postoperative range of motion (ROM). Secondary outcomes included the Western Ontario and McMaster Universities Arthritis Index, Oxford Knee Score, Knee Society Score (KSS), and radiological outcomes. All study patients were followed-up for 2 years after surgery. RESULTS: Patients undergoing MP-TKA had comparable ROM at 1 year (114.6° ± 16.3° vs 111.3° ± 17.8° respectively, P = .88) and 2 years after surgery (114.9° ± 15.5° vs 114.9° ± 16.4° respectively, P = .92) compared to PS-TKA. There were also no differences in Western Ontario and McMaster Universities Arthritis Index (26.8 ± 19.84 vs 22.0 ± 12.03 respectively, P = .14), Oxford Knee Score (42.7 ± 8.1 vs 42.3 ± 6.7 respectively, P = .18), KSS clinical scores (82.9 ± 16.96 vs 81.42 ± 10.45 respectively, P = .12) and KSS functional scores (76.2 ± 18.81 vs 73.93 ± 8.53 respectively, P = .62) at 2-year follow-up. There was no difference in postoperative limb alignment or complications. CONCLUSION: This study demonstrated excellent results in both the single-radius PS-TKA design and MP-TKA design. No differences were identified at 2-year follow-up with respect to postoperative ROM and patient-reported outcome measures.
Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Ontário , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Desenho de Prótese , Amplitude de Movimento ArticularRESUMO
Robotic-arm assisted arthroplasty (RAA) has gained popularity over the past decade because of its ability to provide more accurate implant positioning with less surgical trauma than conventional manual arthroplasty. It has shown better early functional outcomes, less postoperative pain and shorter inpatient stays. A multidisciplinary approach is crucial in improving overall outcomes and ensuring this technology is implemented efficiently and safely, but there is limited published literature on the nursing considerations for managing patients undergoing RAA. This article aims to provide a pragmatic approach for nursing care in the pre-, intra-, and postoperative phases of RAA.
Assuntos
Artroplastia do Joelho , Artroplastia de Substituição , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Osteoartrite do Joelho/cirurgia , Estudos ProspectivosRESUMO
SARS-CoV-2 is the causative virus responsible for the COVID-19 pandemic. This pandemic has necessitated that all professional and elite sport is either suspended, postponed or cancelled altogether to minimise the risk of viral spread. As infection rates drop and quarantine restrictions are lifted, the question how athletes can safely resume competitive sport is being asked. Given the rapidly evolving knowledge base about the virus and changing governmental and public health recommendations, a precise answer to this question is fraught with complexity and nuance. Without robust data to inform policy, return-to-play (RTP) decisions are especially difficult for elite athletes on the suspicion that the COVID-19 virus could result in significant cardiorespiratory compromise in a minority of afflicted athletes. There are now consistent reports of athletes reporting persistent and residual symptoms many weeks to months after initial COVID-19 infection. These symptoms include cough, tachycardia and extreme fatigue. To support safe RTP, we provide sport and exercise medicine physicians with practical recommendations on how to exclude cardiorespiratory complications of COVID-19 in elite athletes who place high demand on their cardiorespiratory system. As new evidence emerges, guidance for a safe RTP should be updated.
Assuntos
Betacoronavirus , Infecções por Coronavirus/complicações , Miocardite/diagnóstico , Pneumonia Viral/complicações , Guias de Prática Clínica como Assunto , Transtornos Respiratórios/diagnóstico , Volta ao Esporte/normas , Atletas , Biomarcadores/sangue , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Humanos , Miocardite/sangue , Miocardite/etiologia , Miocárdio/patologia , Necrose/etiologia , Pandemias , Pneumonia Viral/diagnóstico , Pneumonia Viral/epidemiologia , Transtornos Respiratórios/etiologia , SARS-CoV-2 , Medicina Esportiva/normas , Avaliação de Sintomas , Troponina/sangueRESUMO
BACKGROUND: Allogeneic blood transfusion has been linked with an increase in the risk of surgical site infections (SSIs) through the mechanism of immunomodulation. However, no studies to date have investigated the direct relationship between blood conserving strategies including antifibrinolytics and wound complications after total hip arthroplasties (THA). METHODS: A systematic review and meta-analysis of published randomised controlled trials (RCTs) to investigate the effect of tranexamic acid (TXA) on wound complications after THAs has been conducted. RESULTS: We identified 25 clinical trials which were suitable for detailed data extraction. There were no trials which utilised TXA in revision THA. All studies reported on wound complications including a total of 1608 patients. Using TXA led to a 2% reduction in the risk of developing wound complications compared to the control group with no significant statistical heterogeneity among the study groups (Risk Difference -0.02, 95%, confidence interval CI -0.04 to -0.00, P = 0.01, Heterogeneity I2 = 0%). However, there was no significant difference in clinical outcomes in terms of antibiotic treatment or surgical intervention among the study groups. TXA also reduced intraoperative, postoperative and total blood loss and led to a significant reduction in the proportion of patients requiring allogeneic blood transfusion with no significant differences in deep venous thrombosis, pulmonary embolisms, or other complications between the study groups. CONCLUSION: TXA reduced blood loss and transfusion rates after primary THA surgery. It also reduced wound complication rates but the clinical significance of this needs further investigation through well designed and adequately powered RCTs.
Assuntos
Artroplastia de Quadril/efeitos adversos , Complicações Pós-Operatórias/prevenção & controle , Embolia Pulmonar/prevenção & controle , Ácido Tranexâmico/farmacologia , Antifibrinolíticos/farmacologia , Humanos , Complicações Pós-Operatórias/etiologia , Embolia Pulmonar/etiologiaRESUMO
BACKGROUND: Advances in perioperative care and growing demand for hospital beds have progressively reduced the length of stay in lower limb arthroplasty. Current trends in population demographics and fiscal climate have also added to this change. Individual institutions have reported good outcomes with outpatient hip and knee arthroplasty. Debate remains regarding the safety of this practice, the optimal protocol, and the applicability in different subsections of population. The primary purpose of this review is to assess the complication and reoperation rates of outpatient arthroplasty. METHODS: We performed a systematic review of all papers reporting on 30 and/or 90-day complication rates of outpatient total hip, total knee, and unicondylar knee arthroplasty published from January 1, 2009 to November 1, 2019. Patient demographics, anesthesia, analgesic protocol, selection criteria, and reasons for failed discharge were also extracted. RESULTS: Nineteen manuscripts with a total of 6519 operations between them were analyzed as a part of this systematic review. Mean 90-day readmission rates were 2.3% (range 0%-6%) with 1.61% (range 0%-4%) rate. Overall rate of successful same calendar day discharge was 93.4%. Nausea/dizziness was the most common reason identified (n = 45) for failure of discharge. CONCLUSION: The patients recruited for outpatient joint arthroplasty were younger, more active, and had suffered from less medical comorbidities than the more typical lower limb arthroplasty patient. There are significant differences in the reported complications between the studies reviewed. More research is needed to establish if an outpatient program can produce similar outcomes to a fast-track program. Further research is also needed to establish the optimal perioperative protocols.
Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Humanos , Tempo de Internação , Pacientes Ambulatoriais , Alta do Paciente , Readmissão do Paciente , Complicações Pós-Operatórias/epidemiologia , ReoperaçãoRESUMO
BACKGROUND: The use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions. METHODS: This is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up. RESULTS: Indications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities. CONCLUSION: Revision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications.