Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Prosthet Dent ; 125(3): 501.e1-501.e6, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33248675

RESUMO

STATEMENT OF PROBLEM: New materials have been developed for digital processing, including implant abutments, but studies on their mechanical properties are lacking. PURPOSE: The purpose of this in vitro study was to compare the effect of aging on the fracture resistance, failure mode, and torque loss of restorations made of zirconia and ceramic-reinforced polyetheretherketone (PEEK) abutments with titanium bases. MATERIAL AND METHODS: Titanium-based PEEK and zirconia abutments were milled and veneered with composite resin or feldspathic porcelain in the form of maxillary first premolars (n=10). All the specimens were subjected to an aging process and were assessed after every 250 000 cycles under a stereomicroscope, and torque loss was recorded with an electronic torque meter. Fracture resistance was measured under static load (crosshead speed of 1 mm/min), and failure modes and final torque were determined. A t test was conducted for statistical analyses (α=.05). RESULTS: The fracture resistance of the zirconia restorations was significantly greater than the PEEK-based restorations (P=.001). Torque losses were not significantly different after aging (P=.18); however, significant difference was recorded after the fracture test (P=.007). The effect of fracture load was significantly greater for the zirconia group (P<.001). Unlike with the zirconia group, the failure mode in the PEEK-based restorations was mainly adhesive and favorable (9 of 10 specimens). CONCLUSIONS: Ceramic-reinforced PEEK abutments had acceptable resistance to fracture, a favorable failure mode, and successfully sustained the aging process.


Assuntos
Dente Suporte , Implantes Dentários para Um Único Dente , Benzofenonas , Coroas , Cimentos Dentários , Porcelana Dentária , Falha de Restauração Dentária , Análise do Estresse Dentário , Cetonas , Teste de Materiais , Polietilenoglicóis , Polímeros , Titânio , Torque , Zircônio
2.
Clin Oral Implants Res ; 26(9): 1098-105, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24934081

RESUMO

BACKGROUND AND PURPOSE: It is crucial to keep the misfit of the abutment-fixture unit at the lowest possible rate. There are a few controversial studies on the accuracy of impression making of angulated implants, and much fewer (and controversial) studies on the abutment-level impression technique, which is a convenient and clinically favorable method. Besides, there are no studies on comparison of sectional vs. full-arch trays. We aimed to assess these. METHODS: A trapezoidal model with four angulated implants installed at 20° and 30° buccal tilts was fabricated. Forty impressions were taken from this model, with two groups of full-arch and sectional custom trays (n = 2 × 20), each divided into two subgroups of implant-level and abutment-level techniques (n = 2 × 2 × 10 in four subgroups). Absolute and non-absolute linear and angular impression errors were estimated by comparing the fabricated casts with the model, using a coordinate measuring machine. The effects of sectional/full-arch trays and abutment-level and fixture-level techniques on impression accuracies were analyzed using one- and two-way analyses of variance (ANOVA), Tukey, Mann-Whitney, and one-sample t-tests (α = 0.05, Mann-Whitney's α using the Bonferroni Bonferroni method). RESULTS: No significant differences between the absolute linear errors of the two trays (P = 0.100 [ANOVA]) and the two levels (P = 0.400 [ANOVA]) were observed. The assessment of absolute angular errors showed no significant differences (all P values ≥ 0.4 [ANOVA]). The difference between the linear errors in the full-arch vs. sectional trays was not significant in the fixture-level group (P = 0.290). However, in the abutment-level group, the linear error was significantly greater in the sectional tray compared to full-arch tray (P = 0.013, α = 0.025 [Mann-Whitney]). CONCLUSIONS: Using sectional trays might not be advantageous over full-arch trays. Sectional trays are not recommended for taking abutment-level impressions. The abutment-level impression technique is as accurate as the studied fixture-level technique. Increasing the angle of implants' divergence from 40° to 60° might not usually lead to a significant increase in the errors, particularly when using abutment-level impressions.


Assuntos
Dente Suporte , Implantes Dentários , Técnica de Moldagem Odontológica , Análise de Variância , Modelos Dentários
3.
Int J Prosthodont ; 36(2): 189-193, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-33625391

RESUMO

PURPOSE: To evaluate the effect of cavity tapering on marginal and internal adaptation of endocrowns fabricated from two different ceramic materials. MATERIALS AND METHODS: Two mandibular molar model teeth were prepared with two different cavity tapers (5 and 10 degrees). A total of 40 endocrowns (four groups of 10 each) were milled using lithium disilicate and zirconia-reinforced lithium silicate ceramics for each cavity taper. The marginal and internal adaptation of endocrowns were measured by a stereomicroscope (×30) at 18 different points. The data were statistically analyzed using independent t test (P < .05). RESULTS: A statistically significant difference was shown among the tested groups at 10 degrees of taper (P < .001). At 5 degrees of taper, the difference was insignificant. The greatest internal gap was observed at the pulpal floor in all tested groups. CONCLUSION: All materials had clinically acceptable internal and marginal gaps; however, lithium disilicate ceramic had significantly better adaptation at 10 degrees of taper. Int J Prosthodont 2023;36:189-193. doi: 10.11607/ijp.6877.


Assuntos
Coroas , Adaptação Marginal Dentária , Planejamento de Prótese Dentária , Porcelana Dentária , Cerâmica , Desenho Assistido por Computador
4.
Open Dent J ; 12: 501-509, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30197689

RESUMO

BACKGROUND: No study on the effect of dual-cure stabilizer splint without canine ramp in migraine patients is present. OBJECTIVE: This study was conducted to determine the effects of maxillary flat dual-cure stabilizer occlusal splint on severity, frequency and episodes of headaches in individuals suffering from a migraine. METHODS: In this interventional clinical trial, 30 eligible patients were divided into 2 groups (case and control); each group consisted of 8 men and 7 women. Dual-cure stabilizer splint was made for patients in the case group and they used the adjusted splint 20 hours a day for 6 weeks. The severity, frequency and episodes of migraine attacks before and after using the splint were determined. For grading pain, severity visual analogue scale was used. The data were analyzed using SPSS 20 and Kolmogorov-Smirnov test and paired t-test. RESULTS: The severity, frequency, and episodes of migraine attacks before and after using the splint were reduced by 56%, 68%, and 72%, respectively. The reduction was statistically significant (p < 0.05). DISCUSSION: Despite the effect of occlusal devices on the migraine disorder is controversial, the most researchers agree that using these appliances can be effective in reducing headache in migraine patients. CONCLUSION: Given the favorable effects of dual-cure stabilizer splint on reducing the severity, frequency and episodes of migraine headaches, the device can be used as an effective alternative therapy besides common pain-relieving methods.

5.
Int J Prosthodont ; 30(4): 396-397, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28697214

RESUMO

Dental management of scleroderma patients is difficult and complicated because of compromised intraoral access. Physiotherapy may play an adjunctive and effective treatment role as described in a follow-up report on a previously documented case history.


Assuntos
Prótese Total Inferior , Microstomia/etiologia , Microstomia/reabilitação , Escleroderma Sistêmico/complicações , Idoso , Humanos , Masculino , Modalidades de Fisioterapia
6.
Int J Prosthodont ; 27(2): 169-73, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24596917

RESUMO

Treatment of patients with microstomia due to scleroderma is complicated. Limited mouth opening and altered finger shape present difficulties at every step of the prosthetic rehabilitation. This article describes the prosthetic management of an edentulous patient with severe microstomia induced by scleroderma. From among the existing treatment options and according to the patient's ability and financial considerations, the authors provided a simple prosthetic design that effectively facilitated the patient's rehabilitation. To plan treatment for a patient with scleroderma, it is important to have knowledge about existing complications, alternative methods, and the patient's ability and comfort.


Assuntos
Planejamento de Dentadura , Prótese Total , Boca Edêntula/reabilitação , Escleroderma Sistêmico/complicações , Idoso , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/instrumentação , Prótese Total Inferior , Humanos , Masculino , Microstomia/etiologia , Planejamento de Assistência ao Paciente , Satisfação do Paciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA